Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE PREPARATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Nanomineralogy as a new dimension in understanding elusive geochemical processes in soils: The case of low-solubility-index elements

Nanomineralogical studies of mineral surface coatings in soils reveal insights into biogeochemical processes that heretofore were not known to exist. This is a new dimension in understanding past and present biogeochemical processes in soils, and in this study it is a way to better understand the behavior of low-solubility-index elements such as Al, Ti, and Zr. Soils were sampled from selected sites in Sudbury (Ontario, Canada) that have been affected by acidification and particulate matter emissions from base-metal smelters with subsequent remediation within the past century. These anthropogenic processes have affected an entire landscape, but are now recorded in assemblages of nano-size phases that can be only studied using a combination of focused ion beam technology (for sample preparation) and high-resolution analytical transmission electron microscopy (for phase identification). A first generation of clay minerals (pre-acidification phase), their partial replacement by nano-size hematite and amorphous silica (anthropogenic acidification), and a second generation of clay minerals (post-acidification, including soil remediation) are products of changes in soil biogeochemical processes during these natural and anthropogenic-induced weathering stages. Furthermore, complex assemblages of nanophases formed prior to the second generation of clay minerals depict underlying mechanisms for the mobilization and sequestration of the low-solubility-index elements Zr and Ti under acidic conditions. The occurrence of baddeleyite (ZrO 2 ), anatase (TiO 2 ), and the Magneli phases Ti 4 O 7 and Ti 5 O 9 (all present at the nanoscale) suggest an influx of nanocolloidal Zr and Ti oxides during weathering of smelter-derived particulate matter. Kelyshite {NaZr[Si 2 O 6 (OH)]}, authigenic zircon (ZrSiO 4 ), and kleberite [Fe 3+ Ti 6 O 11 (OH) 5 ] are most likely products of the sequestration of the Zr- and Ti-bearing nanocolloids.

58 GEOSCIENCES↗

An efficient and cost-effective method for preparing transmission electron microscopy samples from powders

The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpled discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data and scripts associated with a manuscript investigating impacts of solid phase extraction on freshwater organic matter optical signatures and mass spectrometry pairing

This data package is associated with the publication “Investigating the impacts of solid phase extraction on dissolved organic matter optical signatures and the pairing with high-resolution mass spectrometry data in a freshwater system” submitted to “Limnology and Oceanography: Methods.” This data is an extension of the River Corridor and Watershed Biogeochemistry SFA’s Spatial Study 2021 (https://doi.org/10.15485/1898914). Other associated data and field metadata can be found at the link provided. The goal of this manuscript is to assess the impact of solid phase extraction (SPE) on the ability to pair ultra-high resolution mass spectrometry data collected from SPE extracts with optical properties collected on ambient stream samples. Forty-seven samples collected from within the Yakima River Basin, Washington were analyzed dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), absorbance, and fluorescence. Samples were subsequently concentrated with SPE and reanalyzed for each measurement. The extraction efficiency for the DOC and common optical indices were calculated. In addition, SPE samples were subject to ultra-high resolution mass spectrometry and compared with the ambient and SPE generated optical data. Finally, in addition to this cross-platform inter-comparison, we further performed and intra-comparison among the high-resolution mass spectrometry data to determine the impact of sample preparation on the interpretability of results. Here, the SPE samples were prepared at 40 milligrams per liter (mg/L) based on the known DOC extraction efficiency of the samples (ranging from ~30 to ~75%) compared to the common practice of assuming the DOC extraction efficiency of freshwater samples at 60%. This data package folder consists of one main data folder with one subfolder (Data_Input). The main data folder contains (1) readme; (2) data dictionary (dd); (3) file-level metadata (flmd); (4) final data summary output from processing script; and (5) the processing script. The R-markdown processing script (SPE_Manuscript_Rmarkdown_Data_Package.rmd) contains all code needed to reproduce manuscript statistics and figures (with the exception of that stated below). The Data_Input folder has two subfolders: (1) FTICR and (2) Optics. Additionally, the Data_Input folder contains dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data (SPS_NPOC_Summary.csv) and relevant supporting Solid Phase Extraction Volume information (SPS_SPE_Volumes.csv). Methods information for the optical and FTICR data is embedded in the header rows of SPS_EEMs_Methods.csv and SPS_FTICR_Methods.csv, respectively. In addition, the data dictionary (SPS_SPE_dd.csv), file level metadata (SPS_SPE_flmd.csv), and methods codes (SPS_SPE_Methods_codes.csv) are provided. The FTICR subfolder contains all raw FTICR data as well as instructions for processing. In addition, post processed FTICR molecular information (Processed_FTICRMS_Mol.csv) and sample data (Processed_FTICRMS_Data.csv) is provided that can be directly read into R with the associated R-markdown file. The Optics subfolder contains all Absorbance and Fluorescence Spectra. Fluorescence spectra have been blank corrected, inner filter corrected, and undergone scatter removal. In addition, this folder contains Matlab code used to make a portion of Figure 1 within the manuscript, derive various spectral parameters used within the manuscript, and used for parallel factor analysis (PARAFAC) modeling. Spectral indices (SPS_SpectralIndices.csv) and PARAFAC outputs (SPS_PARAFAC_Model_Loadings.csv and SPS_PARAFAC_Sample_Scores.csv) are directly read into the associated R-markdown file. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected some of these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

Local structure analysis of diluted magnetic semiconductor Co and Al co-doped ZnO nanoparticles

In this study, Co and Al ions co-doped ZnO nanoparticles (Zn(Al, Co)O NPs) were prepared by our original chemical preparation method. The obtained samples prepared by this method, were encapsulated in amorphous SiO{sub 2}. X-ray diffraction (XRD) results showed Zn(Al, Co)O NPs had a single-phase nature with hexagonal wurtzite structure. These particle sizes could be controlled to be approximately 30 nm. We investigate the effect that the increase in the carrier has on the magnetization by doping Al to Co-doped ZnO NPs. The local structures were qualitatively analyzed using X-ray absorption fine structure (XAFS) measurements.

36 MATERIALS SCIENCE↗

Spherical Nanoindentation Stress-Strain Measurements of BOR-60 14YWT-NFA1 Irradiated Tubes

Spherical nanoindentation stress-strain protocols were applied to characterize unirradiated and fast neutron irradiated nanostructured ferritic alloy (NFA) 14YWT and compared against Berkovich nanohardness and available tensile data. The predicted uniaxial yield strength from spherical, 100 and 5 micron radii, indentation yield strength measurements was 1100-1400 MPa which compares well with the predictions from Berkovich nanohardness, 1200 MPa, and available tensile data, ~1100 MPa. However, spherical indentation measurements predict an increase in the uniaxial yield strength of ~1 GPa while Berkovich nanohardness measurements predict an increase of only ~250 MPa. No tensile data exists on the irradiated condition. It is believed the difference in the predicted uniaxial yield strength between spherical and Berkovich nanoindentation are due to a low number of tests on the irradiated sample combined with the significant heterogeneity in the microstructure, the differences in sensitivity to sample preparation on the irradiated sample between the two indentation protocols , and/or in how strain localizes under the indenter with the possibility of dislocation channeling under Berkovich hardness indents leading to strain softening. Nanoindentation capabilities to test neutron irradiated samples in a radiological area were realized.

36 MATERIALS SCIENCE↗

Centrifugal Microfluidic Platform for Rapid, Multiplexed Detection of TB and HIV Biomarkers in Whole Blood Samples

Infection with Mycobacterium Tuberculosis represents a significant threat to people with immune disorders, such as HIV-positive individuals, and can result in significant health complications or death if not diagnosed and treated early. We present a centrifugal microfluidic platform for multiplexed detection of tuberculosis and HIV biomarkers in human whole blood with minimal sample preparation and a sample-to-answer time of 30 minutes. This multiplexed assay was developed for the detection of two M.tuberculosis secreted proteins, whose secretion represents an active and ongoing infection, as well as detection of HIV p24 protein and human anti-p24 antibodies. The limit of detection for this multiplex assay is in the pg/mL range for both HIV and M.tuberculosis proteins, making this assay potentially useful in the clinical diagnosis of both HIV and Tuberculosis proteins indicative of active infection. Antigen detection for the HIV assay sensitivity was 89%, the specificity 85%. Serological detection had 100% sensitivity and specificity for the limited sample pool. The centrifugal microfluidic platform presented here offers the potential for a portable, fast and inexpensive multiplexed diagnostic device that can be used in resource-limited settings for diagnosis of TB and HIV.

60 APPLIED LIFE SCIENCES↗

Preliminary design polymeric materials experiment

A typical Advanced Technology Laboratory mission flight plan was developed and used as a guideline for the identification of a number of experiment considerations. The experiment logistics beginning with sample preparation and ending with sample analysis are then overlaid on the mission in order to have a complete picture of the design requirements. The results of this preliminary design study fall into two categories. First specific preliminary designs of experiment hardware which is adaptable to a variety of mission requirements. Second, identification of those mission considerations which affect hardware design and will require further definition prior to final design. Finally, a program plan is presented which will provide the necessary experiment hardware in a realistic time period to match the planned shuttle flights. A bibliography of all material reviewed and consulted but not specifically referenced is provided.

Mattingly, S. G.↗

Artemis Curation: Preparing for Sample Return from the Lunar South Pole

Space Policy Directive-1 mandates that “the United States will lead the return of humans to the Moon for long-term exploration and utilization, followed by human missions to Mars and other destinations.” In addition, the Vice President stated that “It is the stated policy of this administration and the United States of America to return American astronauts to the Moon within the next five years,” that is, by 2024. These efforts, under the umbrella of the recently formed Artemis Program, include such historic goals as the flight of the first woman to the Moon and the exploration of the lunar south-polar region. Among the top priorities of the Artemis Program is the return of a suite of geologic samples, providing new and significant opportunities for progressing lunar science and human exploration. In particular, successful sample return is necessary for understanding the history of volatiles in the Solar System and the evolution of the Earth-Moon system, fully constraining the hazards of the lunar polar environment for astronauts, and providing the necessary data for constraining the abundance and distribution of resources for in-situ resource utilization (ISRU). Here we summarize the ef-forts of the Astromaterials Acquisition and Curation Office (hereafter referred to as the Curation Office) to ensure the success of Artemis sample return (per NASA Policy Directive (NPD) 7100.10E).

Mitchell, J. L.↗

Understanding In-Situ Structure and Chemistry at Battery Interfaces Through Time-Resolved Cryo-EM

Transmission and scanning transmission electron microscopy are vital tools for characterizing interfacial structure and chemistry at high spatial resolutions but are limited by the fact that many materials are quickly damaged by electron beam irradiation. This is a challenge particularly for materials relevant to energy applications, such as lithium-containing battery materials, organic-inorganic hybrids, and liquid electrolytes. Cryogenic electron microscopy (cryo-EM) offers a partial solution to this issue by stabilizing beam-sensitive solid-solid or solid-liquid interfaces for characterization, but typical cryo-EM sample preparations are ex situ and thus cannot capture interfaces in their electrified state of interest to applications. Here, we present a method to prepare cryo-EM samples of electrified battery interfaces in situ to preserve the time-resolved structures and chemistry that arise under applied current or bias.

batteries↗

Analysis of the Tank 5f Final Characterization Samples-2011

The Savannah River National Laboratory (SRNL) was requested by SRR to provide sample preparation and analysis of the Tank 5F final characterization samples to determine the residual tank inventory prior to grouting. Two types of samples were collected and delivered to SRNL: floor samples across the tank and subsurface samples from mounds near risers 1 and 5 of Tank 5F. These samples were taken from Tank 5F between January and March 2011. These samples from individual locations in the tank (nine floor samples and six mound Tank 5F samples) were each homogenized and combined in a given proportion into 3 distinct composite samples to mimic the average composition in the entire tank. These Tank 5F composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 5F composite samples include bulk density and water leaching of the solids to account for water soluble species. With analyses for certain challenging radionuclides as the exception, all composite Tank 5F samples were analyzed and reported in triplicate. The target detection limits for isotopes analyzed were based on customer desired detection limits as specified in the technical task request documents. SRNL developed new methodologies to meet these target detection limits and provide data for the extensive suite of components. While many of the target detection limits were met for the species characterized for Tank 5F, as specified in the technical task request, some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The Technical Task Request allows that while the analyses of these isotopes is needed, meeting the detection limits for these isotopes is a lower priority than meeting detection limits for the other specified isotopes. The isotopes whose detection limits were not met in all cases included the following: Al-26, Sn-126, Sb-126, Sb-126m, Eu-152 and Cf-249. SRNL, in conjunction with the plant customer, reviewed all these cases and determined that the impacts were negligible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the tank 6f final characterization samples-2012

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 6F final characterization samples to determine the residual tank inventory prior to grouting. Fourteen residual Tank 6F solid samples from three areas on the floor of the tank were collected and delivered to SRNL between May and August 2011.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Tank 5F Final Characterization Samples-2011 (U)

The Savannah River National Laboratory (SRNL) was requested by SRR to provide sample preparation and analysis of the Tank 5F final characterization samples to determine the residual tank inventory prior to grouting. Two types of samples were collected and delivered to SRNL: floor samples across the tank and subsurface samples from mounds near risers 1 and 5 of Tank 5F. These samples were taken from Tank 5F between January and March 2011. These samples from individual locations in the tank (nine floor samples and six mound Tank 5F samples) were each homogenized and combined in a given proportion into 3 distinct composite samples to mimic the average composition in the entire tank. These Tank 5F composite samples were analyzed for radiological, chemical and elemental components. Additional measurements performed on the Tank 5F composite samples include bulk density and water leaching of the solids to account for water soluble species. With analyses for certain challenging radionuclides as the exception, all composite Tank 5F samples were analyzed and reported in triplicate. The target detection limits for isotopes analyzed were based on customer desired detection limits as specified in the technical task request documents. SRNL developed new methodologies to meet these target detection limits and provide data for the extensive suite of components. While many of the target detection limits were met for the species characterized for Tank 5F, as specified in the technical task request, some were not met. In a few cases, the relatively high levels of radioactive species of the same element or a chemically similar element precluded the ability to measure some isotopes to low levels. The Technical Task Request allows that while the analyses of these isotopes is needed, meeting the detection limits for these isotopes is a lower priority than meeting detection limits for the other specified isotopes. The isotopes whose detection limits were not met in all cases included the following: Al-26, Sn-126, Sb-126, Sb-126m, Eu-152 and Cf-249. SRNL, in conjunction with the plant customer, reviewed all these cases and determined that the impacts were negligible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 12H residuals sample analysis report

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR) to provide sample preparation and analysis of the Tank 12H final characterization samples to determine the residual tank inventory prior to grouting. Eleven Tank 12H floor and mound residual material samples and three cooling coil scrape samples were collected and delivered to SRNL between May and August of 2014.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results and analysis of saltstone cores taken from saltstone disposal unit cell 2A

As part of an ongoing Performance Assessment (PA) Maintenance Plan, Savannah River Remediation (SRR) has developed a sampling and analyses strategy to facilitate the comparison of field-emplaced samples (i.e., saltstone placed and cured in a Saltstone Disposal Unit (SDU)) with samples prepared and cured in the laboratory. The primary objectives of the Sampling and Analyses Plan (SAP) are; (1) to demonstrate a correlation between the measured properties of laboratory-prepared, simulant samples (termed Sample Set 3), and the field-emplaced saltstone samples (termed Sample Set 9), and (2) to validate property values assumed for the Saltstone Disposal Facility (SDF) PA modeling. The analysis and property data for Sample Set 9 (i.e. six core samples extracted from SDU Cell 2A (SDU2A)) are documented in this report, and where applicable, the results are compared to the results for Sample Set 3. Relevant properties to demonstrate the aforementioned objectives include bulk density, porosity, saturated hydraulic conductivity (SHC), and radionuclide leaching behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plastic Scintillators via Rapid Photoinitiated Cationic Polymerization of Vinyltoluene

Cationic photopolymerization is applied for the rapid curing of a vinyltoluene and fluorophore solution into an efficient plastic scintillator. A hard solid is obtained via UV light-initiated polymerization of vinyltoluene, diaryliodonium salt, 9,9-dimethyl-2-phenylfluorene (PhF), and 9,9-dimethyl-2,7-distyrlfluorene (SFS) at ambient conditions with high conversion rates under a range of cationic photoinitiator concentrations, fluorophore concentrations, and light intensities. Insight into photopolymerization kinetics via photo differential scanning calorimetry (photoDSC) revealed photocuring time scales similar to those achieved in a commercial 3D printing resin. Furthermore, scintillator samples prepared cationically performed well compared to samples of equivalent compositions prepared by a lengthy thermally initiated radical polymerization.

36 MATERIALS SCIENCE↗