At least 397 records · Page 22

Commissioning of the Fresno, California, Retrofit Unoccupied Test House

Commissioning of instrumentation and limited short-term testing have been completed on a retrofit unoccupied test house in Fresno, California. This house is intended to be used as a laboratory in which several different methods of space conditioning distribution will be evaluated. This report provides background on the project, including specifications of the house and models used in its development, along with models to be evaluated through its operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Energy Retrofit Guidance for the Building America Solutions Center

The U.S. DOE Building America program has established a research agenda targeting market-relevant strategies to achieve 40% reductions in existing home energy use by 2030. Deep Energy Retrofits (DERs) are part of the strategy to meet and exceed this goal. DERs are projects that create new, valuable assets from existing residences, by bringing homes into alignment with the expectations of the 21st century. Ideally, high energy using, dated homes that are failing to provide adequate modern services to their owners and occupants (e.g., comfortable temperatures, acceptable humidity, clean, healthy), are transformed through comprehensive upgrades to the building envelope, services and miscellaneous loads into next generation high performance homes. These guidance documents provide information to aid in the broader market adoption of DERs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado

To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In this project, the Building America CARB team evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House

In this study, the Building America team, IBACOS, sought to determine cost-effective, energy-efficient solutions for heating and cooling houses. To this end, the team performed field testing in a retrofit unoccupied test house in Fresno, California, to evaluate three air-based heating, ventilation, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. These included a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Greenbuilt Retrofit Test House (Final Report)

The Greenbuilt house is a 1980's era house in the Sacramento area that was a prominent part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration Program. The house underwent an extensive remodel, aimed at improving overall energy efficiency with a goal of reducing the home's energy use by 50%. NREL researchers performed a number of tests on the major systems touched by the retrofit to ensure they were working as planned. Additionally, SMUD rented the house from Greenbuilt Construction for a year to allow NREL to perform a number of tests on the cooling system and the water heating system. The goal of the space conditioning tests was to find the best ways to cut cooling loads and shift the summer peak. The water heating system, comprised of an add-on heat pump water heater and an integrated collector-storage solar water heater, was operated with a number of different draw profiles to see how varying hot water draw volume and schedule affected the performance of the system as a whole. All the experiments were performed with the house empty, with a simulated occupancy schedule running in the house to mimic the load imposed by real occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public Housing: A Tailored Approach to Energy Retrofits

More than 1 million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation 10 ten housing units. Total source energy consumption savings was estimated at 6%-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public Housing: A Tailored Approach to Energy Retrofits

Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 public housing authorities (PHAs) across the country indicated that there is a high level of interest in developing low-cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with four PHAs to develop packages of energy efficiency retrofit measures the PHAs can cost-effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing, and measures that improve equipment efficiency. ARIES documented implementation in 18 housing units. Reductions in average air leakage were 16% and duct leakage reductions averaged 23%. Total source energy consumption savings due to implemented measures was estimated at 3-10% based on BEopt modeling with a simple payback of 1.6 to 2.5 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of units per year nationally.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Garden-Style Apartments in Brooklyn, New York

This research effort sought to achieve a solution package that yields energy savings greater than 30% more than the existing conditions in a minimally intrusive, multifamily, retrofit project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Public Housing: A Tailored Approach to Energy Retrofits

The Building America research team Advanced Residential Integrated Energy Solutions Collaborative (ARIES) worked with four public housing authorities (PHAs) to develop packages of energy-efficiency retrofit measures that the PHAs can cost-effectively implement with their own staffs during the normal course of housing operations when units are refurbished between occupancies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of a Hybrid Retrofit Gas Water Heater

This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the 1/2 inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of a Hybrid Retrofit Gas Water Heater

This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the 1/2 inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of an LED Retrofit Project at Princeton University's Carl Icahn Laboratory

At Princeton University’s Carl Icahn Laboratory, DOE’s Commercial Buildings Integration Program documented the implementation of LED retrofit products for recessed troffers, linear cove lighting, and downlights – as part of Princeton’s first building-wide interior LED project. The conversion to LED enables more extensive use of lighting controls to tailor the lighting to the task and limit the operating hours based on occupancy, and the estimated energy savings including controls is 62% compared to the incumbent system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prefabricated Zero Energy Retrofit Technologies: A Market Assessment

Part of the U.S. Department of Energy's (DOE) Office of Energy Efficiency and Renewable Energy’s (EERE’s) strategic goals is to stimulate the growth of a thriving domestic clean energy manufacturing industry. This report seeks to identify products in the European and U.S. markets that can enable a more integrated and standardized approach to conducting zero energy retrofits, leveraging off-site construction and manufacturing. Greater integration of energy conservation measures into prefabricated building components will further enable efficiency adoption, while reducing project complexity, risks, and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prefabricated Zero Energy Retrofit Technologies: A Market Assessment

The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy’s (EERE’s) mission is to “create and sustain American leadership in the transition to a global clean energy economy.” EERE’s vision is a strong and prosperous America powered by clean, affordable, and secure energy. In support of this vision, one of EERE’s strategic pillars is to stimulate the growth of a thriving domestic clean energy manufacturing industry. This report seeks to identify products in the European and U.S. markets that can enable a more integrated and standardized approach to conducting zero energy retrofits, leveraging off-site construction and manufacturing. Greater integration of energy conservation measures into prefabricated building components will further enable efficiency adoption, while reducing project complexity, risks, and costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗