At least 397 records · Page 22

Thermomechanical analysis and modeling of a high-temperature light trapping planar cavity solar receiver

The development of durable particle-based high-temperature solar receivers is critical for advancing concentrating solar-thermal (CST) technologies to enable high-efficiency power generation and industrial process heat. Here, this study presents a computational framework to evaluate the thermomechanical performance of a proposed enclosed light-trapping planar cavity receiver designed for particle-based thermal energy systems. The receiver incorporates absorptive cavities and fluidized particle-bed channels to enhance heat capture and reduce thermal losses. Finite element analysis (FEA) is employed to assess stress, strain, and creep-fatigue behavior under concentrated solar flux using realistic thermal boundary conditions derived from coupled system models and experimental assembly parameters. The analysis investigates the influence of particle-to-wall heat transfer coefficients (HTC) ranging from 800 to 1800 W/m 2 .K on the thermomechanical response of six candidate high-temperature alloys: Alloy 740H, Alloy 282, Alloy 617, 316H, Alloy 230, and 800H. Results show that increasing HTC reduces thermal gradients, leading to lower stresses and strains and extended minimum predicted creep life. While all materials satisfy fatigue life requirements under the investigated conditions, significant differences in creep resistance are observed. Alloy 740H consistently exhibits the longest minimum predicted creep life and the most favorable durability margins, followed by Alloy 282, with the remaining materials showing reduced creep resistance under identical loading. The reported creep lives are conservative lower-bound estimates intended for comparative material evaluation. This framework highlights the critical roles of material selection and geometry optimization in improving mechanical durability and reliability of solar-thermal receivers, forming a foundation for future experimental validation and design optimization.

14 SOLAR ENERGY↗

Coordinated Optimal Control of PV Inverters and HVAC Loads in Distribution Systems

The increasing integration of distributed energy resources (DERs), such as photovoltaics (PVs) and smart buildings into distribution systems complicate power system operation and controls. This paper proposes a coordinated optimal control strategy for PV inverters and Heating, ventilation, and air conditioning (HVAC) loads in smart buildings to minimize the total network loss in a distribution system. For the HVAC units, we enforce minimum on and off time constraints to avoid frequent switching that can degrade the unit. The proposed control will dispatch optimal control signals of active and reactive power to PV inverters and on/off commands to HVAC units while maintaining the nodal voltage within a secure range and the temperature of HVAC units at a comfort level. The simulation results on a modified IEEE 33-node distribution system demonstrate that the proposed coordinated control scheme can reduce the network loss.

Pani, Naveen↗

Optimizing PCM-integrated walls for potential energy savings in U.S. Buildings

Buildings in the United States account for nearly half of total U.S. energy use. The energy used for space conditioning can be reduced by utilizing thermal energy storage, such as phase change materials (PCMs), into building envelopes; however, the energy savings of PCM-integrated building envelopes reported in the literature vary widely. In the absence of established guidelines, thermophysical requirements of an optimal PCM, its method of application into the building envelope, and the corresponding energy savings under various climates remain unknown. Here, we perform an extensive numerical investigation on the integration of PCM into building walls to establish the key conditions required for effective utilization of PCM in reducing heat gains in the cooling season and heat losses in the heating season. We also determine the optimal transition temperature, optimal PCM location in the wall, and the energy-saving potential of the PCM-integrated building walls in five U.S. cities located in different International Energy Conservation Code climate zones. Results show that employing PCMs in building walls does not always lead to an improvement; in fact, incorrect applications of PCMs can substantially increase energy use in the buildings. In the climates we studied, PCMs were found effective in reducing heat gains during the cooling season while mostly ineffective in managing heat losses during heating season. Depending on the climate, optimized PCMs in U.S. building walls can provide reduction in the annual heat gain in the range of 3.5% to 47.2% and the annual heat loss in the range of -2.8% to 8.3%. Future consideration of buildings with substantial solar gains in winter may lead to more reduction in heat losses by PCMs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled management of electric vehicle workplace charging and office building loads

Significant building energy savings are realized through heating, ventilation, and air conditioning (HVAC) setpoint adjustment and daylighting control. Workplace charging (WPC) enables colocation of electric vehicles (EVs) with office building loads. We proposed managing energy use of workplace EV charging and the office building and determined the number of EVs that building energy savings can facilitate charging. We simulated building energy savings in typical medium offices in Chicago IL, Baltimore MD, and Houston TX, spanning three US climate regions. Considering the EV hosting capacity of the saved building energy and travel patterns of roundtrip commuting, we minimized EV charging costs under time-of-use electricity pricing. Managed WPC can reduce charging electricity bills compared to first-come, first-served charging. The ratio of EVs to chargers, the coincident period of commuters’ dwell time and lower electricity prices, and the number of EVs in the office impacted the economic benefits achieved through charging management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comments on 'Do ultrafine cloud condensation nuclei invigorate deep convection?'

Here we elaborated on the deficiencies associated with the theoretical arguments and model simulations in Grawbowski and Morrison (2020; GM20), and showed that the concept of convective invigoration by aerosols can be supported by both accurate theoretical analysis and explicit physics modeling with prognostic aerosols and supersaturation. Above the freezing level, droplet freezing itself does not change mass loading and the latent heat release resulting from freezing leads to an increase in the buoyancy. The derivation in GM20 is erroneous because of omitting the liquid water sink term. They also ignored the effect of enhanced latent heating from the subsequent growth processes (deposition and riming) after freezing. Regarding aerosol effect on condensational growth, the quasi-steady assumption for supersaturation as adopted in GM20 is invalidated especially when droplet number concentration is low and updraft is strong from both theoretical analysis and our bin microphysics modeling results. The quasi-steady assumption makes condensation independent of droplet number and size and therefore reduces the overall aerosol effects on cloud dynamics. Studying aerosol effects on clouds particularly deep convective clouds requires the exact solution of supersaturation. Any assumption imposed to supersaturation such as saturation adjustment and quasi-steady approximation leads to incorrect aerosol effects on diffusional growth. The exact supersaturation equation clearly shows that condensation depends on droplet number and size, and more droplets in the polluted clouds increase condensation (thus lower supersaturation), leading to enhanced buoyancy and updraft speeds.

Convective invigoration, deep convective clouds, a↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Envelope Improvements and Advanced Air Sealing

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson, et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (GHP) (4.0 COP, 20.5 EER) With Envelope Improvements. This measure combines a two-stage GHP with envelope improvements as a single package. As this package is a combination of two other measures, this document focused on documenting the results associated with this combination of technologies, with individual measure documents for two-stage GHPs and envelope improvements providing the information on the details of these measures. When the two technologies are combined, envelope improvements can modestly reduce energy consumption by a further 10%-15%, but also reduce the required size of the ground heat exchanger and heat pump by approximately 33% on average across all sites. The cost of installing envelope improvements in these homes is likely to be more than paid for by the reduction in equipment and drilling costs in these buildings for the majority of the stock.

15 GEOTHERMAL ENERGY↗

Toroidal modeling of 3D perturbations generated by current filaments in scrape-off layer in tokamak with biased divertor targets

The divertor biasing technique offers a promising alternative to control the edge localized mode (ELM) as well as the divertor heat load in tokamaks, as compared to the resonant magnetic perturbation (RMP) generated by magnetic coils. The linear resistive MHD code MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) is employed to study the plasma response to the n = 2 (n is the toroidal mode number) field perturbation in HL-2A, produced by the divertor biasing current filaments flowing in the scrape-off layer region. The response field due to biasing currents is compared with the RMP field utilized for ELM control in HL-2A. The strength of the radial resonant field perturbation, produced by the biasing currents of 100 A level, is found to be comparable with RMP generated by several kA of ELM control coil currents for the reference plasma. The plasma normal displacement near the X-point and the associated neoclassical toroidal viscosity torque are also computed to be similar between these two techniques. The modeling results thus strongly suggest that the biasing technique can be applied to control ELMs. Moreover, the biasing currents produce field perturbations, including the plasma response, that are localized more near the plasma edge (compared to the RMP counterpart), thus reducing the chance of mode locking associated with core perturbations. Particle orbit tracing also reveals that the biasing current produced magnetic perturbation tends to widen the heat deposition region and induce the strike point splitting of the ion saturation flow on the outer divertor surface, consistent with experimental observations in HL-2A. These toroidal modeling results confirm the possibility of ELM control and plasma exhaust solution by the divertor biasing technique.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

All-polymer nanocomposites having superior strength, toughness and ultralow energy dissipation

Toughening polymers has attracted significant interest. Traditionally, polymer toughness is enhanced by constructing polymer networks or introducing sacrificial bonds into the chains between crosslink points. These strategies, though, introduce pronounced energy dissipation and associated heat, both of which are undesirable under long-term cyclic loading, for example at the interface of implants in the human body. By incorporating single-chain nanoparticles (SCNPs) into linear polymer chains to generate all-polymer nanocomposites (APNCs), we have been able to achieve high strength, high toughness with low energy dissipation. Using a combination of simulation and experimental results, we are advancing a “SCNPs effect” where tightly cross-linked SCNPs produce a modulus contrast to achieve strengthening and toughening. Benefitting from the soft interface, the penetrable and deformable SCNPs cause the surrounding polymer chains to move in concert, significantly reducing the interfacial friction to achieve low energy dissipation. The intramolecular cross-linking of the SCNPs and adhesion between the SCNPs and polymer matrix are critical for realizing such high-performance systems. Based on a Gaussian regression model and back propagation (BP) neural network, the mechanical strength can be predicted and is supported by simulations. Finally, the APNC concept described can be applied to elastomers and gels, broadening its utilization in high-cycle and low-dissipation applications, like soft robots, flexible sensors and cartilage replacements, and artificial heart valves.

36 MATERIALS SCIENCE↗

Analyzing Distribution Transformer Degradation with Increased Power Electronic Loads

The influx of non-linear power electronic loads into the distribution network has the potential to disrupt the existing distribution transformer operations. They were not designed to mediate the excessive heating losses generated from the harmonics. To have a good understanding of current standing challenges, a knowledge of the generation and load mix as well as the current harmonic estimations are essential for designing transformers and evaluating their performance. In this paper, we investigate a mixture of essential power electronic loads for a household designed in PSCAD/EMTdc and their potential impacts on transformer eddy current losses and derating using harmonic analysis. Our findings reveal that in the presence of high power electronic loads (especially third harmonics), increasing PV generation may worsen transformer degradation. However, with a low amount of power electronic loads, additional PV generation helps to reduce the harmonic content in the current and improve transformer performance.

eddy current, harmonics, PV, THD, power transforme↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment (Final Report)

This report documents the FY25 Theory and Simulation Performance Target (TSPT) of developing an integrated modeling framework for fusion reactor design and assessment (FREDA). Over Q1-Q4, new capabilities were developed across both plasma and engineering domains and demonstrated on an example representation of a Compact Advanced Tokamak with a Dual Cooled Lead Lithium blanket. This represents a first-of-a-kind demonstration of coupled core-to-wall-to-engineering for a reactor. Self-consistent CESOL workflows were applied to provide core, pedestal, and SOL prediction; new modules were developed for energetic particle stability (FAR3D) and transport (TGLF-EP) analysis; and boundary plasma modeling (SOLPS-ITER, BOUT++/Hermes-3) was expanded to evaluate wall and divertor heat fluxes and interface with engineering thermal analysis. A parameterized CAD tool, TRACER, was expanded to generate medium-fidelity divertor, blanket, and coil geometries; OpenFOAM and Diablo workflows were applied for first-wall and divertor thermal analyses with helium cooling; and reduced-order models were created for high-mass-flux divertor cooling. Magnet multiphysics capabilities were verified between Elmer, Diablo, and a new MFEM-based solver, and workflows enable stress, thermal, and neutron-fluence analysis of TF coils with neutronics-driven heating. Nuclear and blanket analysis workflows were demonstrated, including tritium breeding, transport, and CFD-informed thermo-mechanical assessment. Preliminary multi-fidelity uncertainty quantification workflows were applied to boundary modeling codes and shown to achieve variance reductions with fewer high-fidelity boundary simulations. Key findings highlight the challenges of resolving the ITEP gap to find suitable balance between wall and divertor loads, neutron heating, and practical limits of PFC cooling. Next step priorities are to develop automated workflows to check boundary code convergence and detachment, implement tighter physics-engineering CAD provenance tracking, and inclusion of plasma-material interface models for SLAG and tungsten cracking behavior. Collectively, these developments establish sophisticated capabilities for predictive, multi-fidelity, whole-device modeling that integrates plasma physics, materials, magnets, and nuclear engineering to guide pathways to viable Fusion Pilot Plant design points.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dust-planetary boundary layer interactions amplified by entrainment and advections

Mineral dust contributes to more than half of the global aerosol loading. However, the radiative impacts of dust aerosols on planetary boundary layer (PBL) structure have not been explored sufficiently. During a typical dust storm event over Tarim Basin, dust aerosols exhibit a well-mixed distribution during the daytime in spite of a shallow layer of dust particles accumulated at higher altitudes. By contrast, nocturnal dust plumes are located near the surface due to stable stratification. We demonstrate that these differentiated vertical distributions determine the spatial heterogeneity of dust loading, radiative fluxes and PBL height variations. Dust aerosols cause daytime PBL suppression and nighttime PBL promotion through modulating surface and atmospheric radiative budgets. Specifically, dust-induced cooling effect within PBL directly inhibits the daytime PBL development. PBL suppression effect is then amplified by entrainment processes resulting in excessively low PBL height, especially for dust particles below but near the PBL top. Dust plumes weaken updrafts from PBL and downdrafts of the free atmosphere, which further reduce the entrainment mixing through attenuating horizontal and vertical advection, and eventually amplify PBL suppression. At night, near-surface dust aerosols stimulate a warm and unstable lower atmosphere, generate warm advection heating and promote the PBL development. Our study highlights the importance of specifying entrainment parameters and nighttime advection activities in quantifying the dust-PBL interactions.

54 ENVIRONMENTAL SCIENCES↗

Cost details from front-end engineering design of piperazine with the advanced stripper

This Front-End Engineering Design (FEED) was funded by the U.S. Department of Energy (DOE) to estimate the cost to capture and compress 90% of the CO 2 from an existing natural gas combined cycle (NGCC) in Denver City, Texas, USA. The FEED used the PZAS (Piperazine with the Advanced Stripper) 2G amine scrubbing technology developed and modeled by The University of Texas at Austin. This FEED is unique in providing more public cost details than other FEEDs funded by DOE. The primary objective of the FEED was to provide a comprehensive estimate for the total installed cost of the capture plant. The estimated capital cost of NGCC at the Mustang Station is $\$727$ million for a capacity of 460 MW and 1.6 million tonnes CO 2 /yr. This includes a contingency of $\$104.6$ million and a contractor’s profit of $\$60.1$ million. The total direct field cost is $\$384.1$ million. With an optimistic fuel value of $\$3$/MMBtu, the estimated cost of capture varies from $\$85$/t at 4% IRR/85% load to $\$170$/t at 10% IRR/52% load. Air cooling is technically feasible but expensive. The air cooling systems for the water wash and pump-around intercooling account for 23.4% of the direct cost. The gas-fired boilers represent only 4% of the direct costs, but steam extraction would reduce energy cost, free up cooling water, and reduce the direct costs of processing additional flue gas and CO 2 from the boilers. The absorbers represent 9.6% of the direct cost in this FEED with no direct contact cooler and only 7.6 m of packing. Furthermore, the solvent cross exchangers are less expensive than expected (2.5% of direct costs). Doubling the number of these exchangers could reduce the heat duty from 3.0 to 2.5 GJ/t CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residential Natural Gas Demand Response Potential during Extreme Cold Events in Electricity-Gas Coupled Energy Systems

In regions where natural gas is used for both power generation and heating buildings, extreme cold weather events can place the electrical system under enormous stress and challenge the ability to meet residential heating and electric demands. Residential demand response has long been used in the power sector to curtail summer electric load, but these types of programs in general have not seen adoption in the natural gas sector during winter months. Natural gas demand response (NG-DR) has garnered interest given recent extreme cold weather events in the United States; however, the magnitude of savings and potential impacts—to occupants and energy markets—are not well understood. We present a case-study analysis of the technical potential for residential natural gas demand response in the northeast United States that utilizes diverse whole-building energy simulations and high-performance computing. Our results show that NG-DR applied to residential heating systems during extreme cold-weather conditions could reduce natural gas demand by 1–29% based on conservative and aggressive strategies, respectively. This indicates a potential to improve the resilience of gas and electric systems during stressful events, which we examine by estimating the impact on energy costs and electricity generation from natural gas. We also explore relationships between hourly indoor temperatures, demand response, and building envelope efficiency.

03 NATURAL GAS↗

Passive Energy-Saving Solutions for Clothes Dryers: A Modeling and Experimental Study for Improved Efficiency and Affordability

Dryers are integral appliances in modern households, yet their significant power consumption remains a critical challenge for reducing energy bills and upgrades. This work presents the outcomes of a comprehensive investigation aimed at lowering the operating energy costs of the dryer through modeling and experimental approaches. Specifically, the objectives of this research are twofold: (1) to reduce energy consumption without negatively impacting drying performance or time; and (2) to ensure affordability by developing retrofittable solutions characterized by low cost and a quick payback period. These strategies promise universal applicability to all dryer categories, encompassing both gas and electric models, by tackling core issues such as unnecessary heat loss and excess energy supply, both prevalent across dryer designs. Our methodology combines robust modeling frameworks and experimental validation to target energy efficiency improvements through three primary pathways: (1) effective heat loss management using ultralow-cost insulation materials tailored for dryer systems; (2) heat management across the drying cycle, facilitated by passive heat transfer mechanisms, and (3) optimization of heat supply to the load to ensure precise energy delivery, minimizing waste. These innovations are designed to seamlessly integrate with existing dryer configurations, providing a scalable and retrofittable solution that ensures affordability without requiring substantial redesigns or expensive components. Using these methods, the study demonstrates improvement opportunities in dryer energy consumption while maintaining the desired performance. The modeling component utilizes computational simulations to evaluate the thermal and energy performance of these innovations under varied operational conditions, providing foundational insights for experimental design. By addressing critical areas such as heat loss, energy recovery, and supply optimization, this work proposes impactful solutions for lowering the energy costs in domestic clothes dryers. The ultralow-cost, retrofittable nature of the proposed strategies ensures widespread adoption potential across diverse dryer categories, making significant strides toward affordable household energy practices.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Thermal and mechanical performance of gypsum composites containing fly ash cenosphere encapsulated phase change materials

Utilizing phase change materials (PCMs) within construction materials improves the thermal energy storage capabilities in the built environment. Notably, integrating PCMs into drywalls presents a promising avenue to reduce building energy use. However, incorporating PCMs into drywalls poses challenges, particularly reduced mechanical properties and workability limitations as it can adversely affect the hardening and cohesiveness of gypsum composites. To address these challenges, this study explores a novel strategy to incorporate PCMs into gypsum composites through fly ash cenosphere-encapsulated PCM, namely CenoPCM, aiming to enhance the mechanical properties and thermal conductivity over existing commercial counterparts. An experimental program was conducted to study the impact of the inclusion of CenoPCM on the mechanical and thermal performance of gypsum composites, and the results were compared to those of commercially available polymerencapsulated PCM benchmark (Micronal). The findings highlighted that PCM-charged samples exhibited up to 95.90 J/g (CenoPCM) of latent heat with 70 % CenoPCM loading. The results of mechanical tests also showed that CenoPCM outperformed its polymer-encapsulated counterpart, achieving 55 % higher mechanical strength on average. Here, this improvement is attributed to the rigid shell of fly ash cenosphere (FAC) serving as a PCM carrier, providing a skeleton-like structure to gypsum composites for higher load-bearing capacity. Additionally, hotbox tests demonstrated that the CenoPCM-charged wall panels yielded a 20 % higher thermal conductivity and a 22 % increased time lag compared to Micronal PCM-charged panels, indicating its potential to shift the peak load in buildings.

Ceno PCM↗

Evolution of intermittent filaments in the scrape-off layer of NSTX

Filamentary structures naturally arise from background turbulence in the scrape-off layer (SOL) of plasmas, leading to significant particle and heat transport that can degrade overall plasma confinement. This enhanced transport can contribute to unacceptably high heat loads on plasma-facing components. As such, understanding the physics of SOL plasma filaments is critical for predicting and mitigating their effects in future fusion devices. On the National Spherical Torus Experiment (NSTX), plasma filaments—commonly referred to as “blobs”—were investigated using the gas-puff imaging (GPI) diagnostic in the edge and SOL regions. The analysis involved identifying, segmenting, and tracking the characteristic contours of the blobs in each frame of the GPI video sequences. Their evolution was characterized through shape descriptors, velocity, and angular velocity derived from their contour coordinates. The results indicate that as the blob area increases, their shapes become more concave and less circular, suggesting reduced structural stability in larger blobs. This result aligns with previous theoretical results where it was shown that larger blobs are more susceptible to instabilities [Krasheninnikov et al., J. Plasma Phys. 74, 679–717 (2008) and D'Ippolito et al., Phys. Plasmas 18, 060501 (2011)]. A positive correlation was observed between radial velocity and radial position, suggesting radially outward acceleration of the filaments, potentially driven by decreasing viscous drag toward the far SOL. Interestingly, blobs in background SOL turbulence exhibited minimal spinning in contrast to filaments originating from edge localized modes, which show substantial rotation during their paths [Lampert et al., Phys. Plasmas 29, 102502 (2022)]. Statistical analysis of the solidity and total curvature shape descriptors, along with their temporal evolution, revealed relatively broad, near-Gaussian distributions. This suggests that blob morphology is strongly influenced by stochastic turbulent processes in the surrounding plasma environment. Blob parameters were also compared with bulk plasma and radial profile measurements. Notable trends were found between blob rotation and poloidal velocity with collisionality and line-integrated density. These findings contribute to a deeper understanding of blob dynamics and provide valuable insights for refining SOL turbulence models.

Covariance and correlation↗