Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROOFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Modeling, Analysis, and Preservation Techniques for Historic Reinforced Concrete Structures in Seismic Prone Regions Case Study: Augusta Airship Hangar, Sicily

Throughout the world there are hundreds of historic monuments and structures considered to be invaluable and irreplaceable. They are symbols of cultural identity and a means of educating people about history. Preservation of historic monuments and structures is therefore an important part of safeguarding these cultural heritage sites so that they retain their value for future generations.This report discusses a procedure for the investigation of seismic hazards in existing buildings and possible steps that can be taken to avoid damage caused by these hazards. The Augusta Airship Hangar located in Sicily, will be used as a case study however the topics addressed in this paper can be applied to other structures of historic value around the world.First state-of-the-art scanning procedures were used to create scale digital models that were imported into a structural analysis program. Within this program dynamic analyses were performed on the model based on actual ground motions taken close to the site. This data was used to determine the period and mode shapes of the structure. Then a nonlinear analysis, including a static pushover analysis, was implemented on a two-dimensional model of the structural frame. From this analysis the failure mechanisms of the structure were revealed with relation to an allowable roof displacement. The structural integrity of the structure was evaluated based on pre-defined performance goals. Finally multiple suggestions were made how the Augusta Airship Hangar might be repaired and strengthened so that this structure will not be destroyed should an earthquake occur.The results of our study show that historic structures, despite their age, can still be strong and ductile. Also there are a multitude of effective preservation and retrofit techniques that can be used to strengthen these historic structures, should an earthquake occur. Through this study, the Augusta Airship Hangar has proven to be not only a historic symbol for Sicily but also can be used as an example for the rehabilitation of other historic structures. The techniques and processes discussed in this paper can be applied to other historic reinforced concrete structures and can be expanded upon in future investigations.

58 GEOSCIENCES↗

Pushover, Response Spectrum and Time History Analyses of Safe Rooms in a Poor Performance Masonry Building

The idea of safe room has been developed for decreasing the earthquake casualties in masonry buildings. The information obtained from the previous ground motions occurring in seismic zones expresses the lack of enough safety of these buildings against earthquakes. For this reason, an attempt has been made to create some safe areas inside the existing masonry buildings, which are called safe rooms. The practical method for making these safe areas is to install some prefabricated steel frames in some parts of the existing structure. These frames do not carry any service loads before an earthquake. However, if a devastating earthquake happens and the load bearing walls of the building are destroyed, some parts of the floors, which are in the safe areas, will fall on the roof of the installed frames and the occupants who have sheltered there will survive. This paper presents the performance of these frames located in a destroying three storey masonry building with favorable conclusions. In fact, the experimental pushover diagram of the safe room located at the ground-floor level of this building is compared with the analytical results and it is concluded that pushover analysis is a good method for seismic performance evaluation of safe rooms. For time history analysis the 1940 El Centro, the 2003 Bam, and the 1990 Manjil earthquake records with the maximum peak accelerations of 0.35g were utilized. Also the design spectrum of Iranian Standard No. 2800-05 for the ground kind 2 is used for response spectrum analysis. The results of time history, response spectrum and pushover analyses show that the strength and displacement capacity of the steel frames are adequate to accommodate the distortions generated by seismic loads and aftershocks properly.

36 MATERIALS SCIENCE↗

Cerreto di Spoleto (Umbria-Italy): Seismic amplification at the ENEA local array stations

The Nerina valley, where Borgo Cerreto is located, is surrounded by the Apennine mount chain at the top of which lies the historical centre of Cerreto di Spoleto. The study is part of a research project aiming at analysing natural disasters and their impact on the Italian cultural heritage. Within the framework of this research project, local seismic records were analysed for both the carbonate ridge and the bordering alluvial valley. The choice of Cerreto di Spoleto as a test site derives from the analysis of Italian seismic hazard maps, obtained in terms of peak ground velocity and taking into account regional geology. The maps highlight the considerable seismic hazard which characterises the Apennine belt and its possible increase due to the effect of alluvial deposits. To this aim, ENEA installed in the 80's an accelerometric array (CODISMA up to 2000 and, in the following years, ETNA; for more detailed description see [1]. The 14 October event, was recorded both at the roof of CSM and at BCT stations. This is important to check the features observed comparing the FAS of acceleration at CSM and BCT during the 26 September events. Unfortunately the station at CSM basement did not record the above mentioned events but several aftershocks were recorded at each array station. Velocimetric records of both ambient noise and small-magnitude earthquakes were analysed in order to identify amplification conditions. The analysis was carried out in the time domain, through directional energy evaluation, and in the frequency domain, through H/V spectral ratios and spectral ratios with respect to a reference station.

58 GEOSCIENCES↗

Non Linear Step By Step Seismic Response and the Push Over Analysis Comparison of a Reinforced Concrete of Ductile Frames 25 Level Building

Based on a ductile frames 25 level building, a non-linear analysis with increased monotonically lateral loads (Push-Over) was made in order to determine its collapse and its principal responses were compared against the time-history seismic responses determined with the SCT-EW-85 record. The seismic-resistance design and faced to gravitational loads was made according to the Complementary Technical Norms of Concrete Structures Design (NTC-Concrete) and the NTC-Seismic of the Mexico City Code (RDF-04), satisfying the limit service states (relative lateral displacement between story height maximum relations, story drifts {<=}0.012) and failure (seismic behavior factor, Q = 3). The compressible (soft) seismic zone III{sub b} and the office use type (group B) were considered. The non-lineal responses were determined with nominal and over-resistance effects. The comparison were made with base shear force-roof lateral displacement relations, global distribution of plastic hinges, failure mechanics tendency, lateral displacements and story drift and its distribution along the height of the building, local and global ductility demands, etc. For the non-linear static analysis with increased monotonically lateral loads, was important to select the type of lateral forces distribution.

58 GEOSCIENCES↗

Shaking Table Tests Validating Two Strengthening Interventions on Masonry Buildings

Masonry buildings constitute quite often a precious cultural heritage for our cities. In order to future generations can enjoy this heritage, thence, effective projects of protection should be developed against all the anthropical and natural actions which may irreparably damage old masonry buildings. However, the strengthening interventions on these constructions have to respect their authenticity, without altering the original conception, not only functionally and aesthetically of course, but also statically. These issues are of central interests in the Messina area, where the seismic protection of new and existing constructions is a primary demand. It is well known, in fact, that the city of Messina lies in a highly seismic zone, and has been subjected to two destructive earthquakes in slightly more than one century, the 1783 Calabria earthquake and the more famous 1908 Messina-Reggio Calabria earthquake. It follows that the retrofitting projects on buildings which survived these two events should be designed with the aim to save the life of occupants operating with 'light' techniques, i.e. respecting the original structural scheme. On the other hand, recent earthquakes, and in particular the 1997 Umbria-Marche sequence, unequivocally demonstrated that some of the most popular retrofitting interventions adopted in the second half the last century are absolutely ineffective, or even unsafe. Over these years, in fact, a number of 'heavy' techniques proliferated, and therefore old masonry buildings suffered, among others, the substitution of existing timber slabs with more ponderous concrete slabs and/or the insertion of RC and steel members coupled with the original masonry elements (walls, arches, vaults). As a result, these buildings have been transformed by unwise engineers into hybrid structures, having a mixed behaviour (which frequently proved to be also unpredictable) between those of historic masonry and new members. Starting from these considerations, a numerical and experimental research has been carried out, aimed at validating two different strengthening interventions on masonry buildings: (i) the substitution of the existing roof with timber-concrete composite slabs, which are able to improve the dynamic behaviour of the structure without excessively increase the mass, and (ii) the reinforcement of masonry walls with FRP materials, which allow increasing both stiffness and strength of the construction. The experimental tests have been performed on a 1:2 scale model of a masonry building resembling a special type, the so-called 'tipo misto messinese', which is proper to the reconstruction of the city of Messina after the 1783 Calabria earthquake. The model, incorporating a novel timber-concrete composite slab, has been tested on the main shaking table available at the ENEA Research Centre 'Casaccia', both before and after the reinforcement with FRP materials. Some aspects related to the definition of the model and to the selection of an appropriate seismic input will be discussed, and numerical results confirming the effectiveness of the interventions mentioned above will be presented.

58 GEOSCIENCES↗

Static Nonlinear Analysis In Concrete Structures

Push-over analysis is a simple and applied approach which can be used for estimation of demand responses influenced by earthquake stimulations. The analysis is non-linear static analysis of the structure affected under increasing lateral loads and specifying the displacement--load diagram or structure capacity curve, draw the curve the base shear values and lateral deflection on the roof level of the building will be used. However, for estimation of the real behavior of the structure against earthquake, the non-linear dynamic analysis approaches and various accelerographs should be applied. Of course it should be noted that this approach especially in relation with tall buildings is complex and time consuming. In the article, the different patterns of lateral loading in push-over analysis have been compared with non-linear dynamic analysis approach so that the results represented accordingly. The researches indicated the uniformly--distributed loading is closer to real status.

58 GEOSCIENCES↗

Influence of Photovoltaic Shading on Rooftop Heat Transfer, Building Energy Loads, and Photovoltaic Power Output

Photovoltaic (PV) modules on building rooftops provide shade from summer heating, leading to a reduction in cooling load during hot seasons. However, PV shading also reduces passive solar heating during winter months, leading to an increase in the building heating load during cold seasons. In this study, the heat transfer performance of an enclosure formed by adjacent PV modules is analyzed for three locations in the United States, comparing the daily heat flux through rooftops for the case of a PV-shaded rooftop as well as an unshaded roof. Several result metrics are developed as part of this work, including the saved energy load (SEL), or the energy conserved by adding PV-shading to the rooftop, and the additional energy load (AEL), or the supplemental building energy required to replace shaded solar heating. Lastly, this work calculates the utility factor, being the ratio of SEL and PV power output to AEL as a metric of PV effectiveness. SELs are 5.2, 6.2, and 11.7 kWh/m 2 · year for Dayton, Boise, and Phoenix, respectively, while the AELs for the same locations are 1.6, 1.5, and 2.1 kWh/m 2 · year. The utility factors for the same three locations are 61, 71, and 79. In general, locations with hot, non-cloudy summers and clear skies in winter see the largest utility factor. Further, it is shown that PV shading can conserve building energy during the winter months by preventing radiative losses to cold winter skies.

13 HYDRO ENERGY↗

EVALUATION OF PROMPT DOSE ENVIRONMENT IN THE NATIONAL IGNITION FACILITY DURING D-D AND THD SHOTS

Evaluation of the prompt dose environment expected in the National Ignition Facility (NIF) during Deuterium-Deuterium (D-D) and Tritium-Hydrogen-Deuterium (THD) shots have been completed. D-D shots resulting in the production of an annual fusion yield of up to 2.4 kJ (200 shots with 10{sup 13} neutrons per shot) are considered. During the THD shot campaign, shots generating a total of 2 x 10{sup 14} neutrons per shot are also planned. Monte Carlo simulations have been performed to estimate prompt dose values inside the facility as well as at different locations outside the facility shield walls. The Target Chamber shielding, along with Target Bay and Switchyard walls, roofs, and shield doors (when needed) will reduce dose levels in occupied areas to acceptable values during these shot campaigns. The calculated dose values inside occupied areas are small, estimated at 25 and 85 {micro}rem per shot during the D-D and THD shots, respectively. Dose values outside the facility are insignificant. The nearest building to the NIF facility where co-located workers may reside is at a distance of about 100 m from the Target Chamber Center (TCC). The dose in such a building is estimated at a fraction of a ?rem during a D-D or a THD shot. Dose at the nearest site boundary location (350 m from TCC), is caused by skyshine and to a lesser extent by direct radiation. The maximum off-site dose during any of the shots considered is less than 10 nano rem.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

E906/SeaQuest MARS15 Simulation

The E906/SeaQuest spectrometer is designed to measure high energy muons produced in the forward direction by interactions of the 120 GeV Main Injector proton beam with a variety of targets. The spectrometer consists of two dipole magnets (both of which deflect charged particles in the horizontal plane) and a collection of tracking detectors. The first spectrometer magnet (FMAG) is a solid iron magnet. This magnet serves as a beam dump as well as a muon analysis magnet. A series of MARS15 simulations were done by Nikolai Mokhov to verify and guide the design of concrete shielding around FMAG and the target area immediately upstream of FMAG. The result of the fourth and last round of simulations is summarized here. This was a high statistics simulation that required approximately 48 cpu-weeks of computing time on the APC Energy Deposition Group cluster. The MARS15 simulation used a model of FMAG and its surroundings. The model includes air gaps in the concrete shielding, the largest of which are required because of the geometry of the saddle coils. A small volume surrounding the beam line just upstream of the magnet is filled with borated polyethylene. The borated polyethylene extends into the air gap necessitated by the saddle coils. With the exception of the top layer of six 'H' blocks, the concrete shielding is modeled in detail. The top layer of blocks are intended to shield the roof and downstream end of NM4 in the event of a loss of beam accident well upstream of the target; they provide only a small benefit in the normal running condition simulated by MARS.

43 PARTICLE ACCELERATORS↗

EVALUATION OF THE DURABILITY OF THE STRUCTURAL CONCRETE OF REACTOR BUILDINGS AT SRS

The Department of Energy (DOE) intends to close 100-150 facilities in the DOE complex using an in situ decommissioning (ISD) strategy that calls for grouting the below-grade interior volume of the structure and leaving the above-grade interior open or demolishing it and disposing of it in the slit trenches in E Area. These closures are expected to persist and remain stable for centuries, but there are neither facility-specific monitoring approaches nor studies on the rate of deterioration of the materials used in the original construction or on the ISD components added during closure (caps, sloped roofs, etc). This report will focus on the evaluation of the actual aging/degradation of the materials of construction used in the ISD structures at Savannah River Site (SRS) above grade, specifically P & R reactor buildings. Concrete blocks (six 2 to 5 ton blocks) removed from the outer wall of the P Reactor Building were turned over to SRNL as the first source for concrete cores. Larger cores were received as a result of grouting activities in P and R reactor facilities. The cores were sectioned and evaluated using microscopy, x-ray diffraction (XRD), ion chromatography (IC) and thermal analysis. Scanning electron microscopy shows that the aggregate and cement phases present in the concrete are consistent with the mix design and no degradation mechanisms are evident at the aggregate-cement interfaces. Samples of the cores were digested and analyzed for chloride ingress as well as sulfate attack. The concentrations of chloride and sulfate ions did not exceed the limits of the mix design and there is no indication of any degradation due to these mechanisms. Thermal analysis on samples taken along the longitudinal axis of the cores show that there is a 1 inch carbonation layer (i.e., no portlandite) present in the interior wall of the reactor building and a negligible carbonation layer in the exterior wall. A mixed layer of carbonate and portlandite extends deeper into the interior (2-3 inches) and exterior (1-2 inches) walls. This is more extensive than measured in previous SRS structures. Once the completely carbonated layer reaches the rebar that is approximately 2-3 inches into the concrete wall, the steel is susceptible to corrosion. The growth rate of the carbonated layer was estimated from current observations and previous studies. Based on the estimated carbonation rate, the steel rebar should be protected from carbonation induced corrosion for at least another 100 years. If degradation of these structures is dominated by the carbonation mechanism, the length of time before water intrusion is expected into the process room of P-reactor is estimated to be between 425-675 years.

36 MATERIALS SCIENCE↗

Analysis of IECC (2003, 2006, 2009) and ASHRAE 90.1-2007 Commercial Energy Code Requirements for Mesa, AZ.

This report summarizes code requirements and energy savings of commercial buildings in Climate Zone 2B built to the 2009 IECC and ASHRAE Standard 90.1-2007 when compared to the 2003 IECC and the 2006 IECC. In general, the 2009 IECC and ASHRAE Standard 90.1-2007 have higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment. HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted. The energy analysis results show that commercial buildings meeting the 2009 IECC requirements save 4.4% to 9.5% site energy and 4.1% to 9.9% energy cost when compared to the 2006 IECC; and save 10.6% to 29.4% site energy and 10.3% to 29.3% energy cost when compared to the 2003 IECC. Similar analysis comparing ASHRAE Standard 90.1-2007 requirements to the 2006 IECC shows that the energy savings are in the 4.0% to 10.7% for multi-family and retail buildings, but less than 2% for office buildings. Further comparison of ASHRAE Standard 90.1-2007 requirements to the 2003 IECC show site energy savings in the range of 7.7% to 30.6% and energy cost savings range from 7.9% to 30.3%. Both the 2009 IECC and ASHRAE Standard 90.1-2007 have the potential to save energy by comparable levels for most building types.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-Competitive Residential and Commercial Fully Automated PV Systems Technology: Final technical Report, August 2011

Under DOE's Technology Pathway Partnership program, SunPower Corporation developed turn-key, high-efficiency residential and commercial systems that are cost effective. Key program objectives include a reduction in LCOE values to 9-12 cents/kWh and 13-18 cents/kWh respectively for the commercial and residential markets. Target LCOE values for the commercial ground, commercial roof, and residential markets are 10, 11, and 13 cents/kWh. For this effort, SunPower collaborated with a variety of suppliers and partners to complete the tasks below. Subcontractors included: Solaicx, SiGen, Ribbon Technology, Dow Corning, Xantrex, Tigo Energy, and Solar Bridge. SunPower's TPP addressed nearly the complete PV value chain: from ingot growth through system deployment. Throughout the award period of performance, SunPower has made progress toward achieving these reduced costs through the development of 20%+ efficient modules, increased cell efficiency through the understanding of loss mechanisms and improved manufacturing technologies, novel module development, automated design tools and techniques, and reduced system development and installation time. Based on an LCOE assessment using NREL's Solar Advisor Model, SunPower achieved the 2010 target range, as well as progress toward 2015 targets.

14 SOLAR ENERGY↗

HFC Concrete: A Low-­Energy, Carbon-Dioxide­-Negative Solution for reducing Industrial Greenhouse Gas Emissions (Final Technical Report)

Solidia/CCSM received funding for further research and development of its Low Temperature Solidification Process (LTS), which is used to create hydrate-free concrete (HFC). LTS/HFC is a technology/materials platform that offers wide applicability in the built infrastructure. Most importantly, it provides a means of making concrete without Portland cement. Cement and concrete production is a major consumer of energy and source of industrial greenhouse gas (GHG) emissions. The primary goal of this project was to develop and commercialize a novel material, HFC, which by replacing traditional concrete and cement, reduces both energy use and GHG emissions in the built infrastructure. Traditional concrete uses Portland Cement (PC) as a binder. PC production involves calcination of limestone at ~1450°C, which releases significant amounts of CO 2 gas to the atmosphere and consumes a large amount of energy due to the high temperature required. In contrast, HFC is a carbonate-based hydrate-free concrete (HFC) that consumes CO 2 gas in its production. HFC is made by reaction of silicate minerals with CO 2 at temperatures below 100°C, more than an order-of-magnitude below the temperature required to make PC. Because of this significant difference in temperature, it is estimated that we will be able to reduce energy use in the cement and concrete industry by up to 30 trillion Btu by 2020. Because of the insulating properties of HFC, we believe we will also be able to significantly reduce energy use in the Building sector, though the extent of this saving is not yet quantified. It is estimated that production of a tonne of PC-based concrete requires about 6.2 million Btu of energy and produces over 1 tonne of CO 2 emissions (Choate, 2003). These can be reduced to 1.9 million Btu and 0.025 tonnes of CO 2 emissions per tonne of HFC (with overall CO 2 -negativity possible by increasing carbonation yield). In this way, by replacing PC-based concrete with HFC in infrastructure we can reduce energy use in concrete production by 70%, and reduce CO 2 emissions by 98%; thus the potential to reduce the impact of building materials on global warming and climate change is highly significant. Low Temperature Solidification (LTS) is a breakthrough technology that enables the densification of inorganic materials via a hydrothermal process. The resulting product exhibits excellent control of chemistry and microstructure, to provide durability and mechanical performance that exceeds that of concrete or natural stone. The technology can be used in a wide range of applications including facade panels, interior tiles, roof tiles, countertops, and pre-cast concrete. Replacing traditional building materials and concrete in these applications will result in significant reduction in both energy consumption and CO 2 emissions.

54 ENVIRONMENTAL SCIENCES↗

Concentrating Solar Panels: Bringing the Highest Power and Lowest Cost to the Rooftop

Soliant Energy is a venture-capital-backed startup focused on bringing advanced concentrating solar panels to market. Our fundamental innovation is that we are the first company to develop a racking solar concentrator specifically for commercial rooftop applications, resulting in the lowest LCOE for rooftop electricity generation. Today, the commercial rooftop segment is the largest and fastest-growing market in the solar industry. Our concentrating panels can make a major contribution to the SAI's objectives: reducing the cost of solar electricity and rapidly deploying capacity. Our commercialization focus was re-shaped in 2009, shifting from an emphasis solely on panel efficiency to LCOE. Since the inception of the SAI program, LCOE has become the de facto standard for comparing commercial photovoltaic systems. While estimation and prediction models still differ, the emergence of performance-based incentive (PBI) and feed-in tariff (FIT) systems, as well as power purchase agreement (PPA) financing structures make LCOE the natural metric for photovoltaic systems. Soliant Energy has designed and demonstrated lower-cost, higher-power solar panels that consists of 6 (500X) PV module assemblies utilizing multi-junction cells and an integrated two-axis tracker. In addition, we have designed and demonstrated a prototype 1000X panel assembly with 8. Cost reductions relative to conventional flat panel PV systems were realized by (1) reducing the amount of costly semiconductor material and (2) developing strategies and processes to reduce the manufacturing costs of the entire system. Performance gains against conventional benchmarks were realized with (1) two-axis tracking and (2) higher-efficiency multi-junction PV cells capable of operating at a solar concentration ratio of 1000X (1000 kW/m2). The program objectives are: (1) Develop a tracking/concentrating solar module that has the same geometric form factor as a conventional flat, roof mounted photovoltaic (PV) panel - the Soliant module will produce more power and cost less than conventional panels of the same size; (2) Target LCOE: $0.079/kWh in 2010; (3) Target efficiency - 26% in 2010 (22% for 2008 prototype, 24% for 2009 pilot); and (4) Target performance - equivalent to 650Wp in 2010 (490W for 2008 prototype, 540W for 2009 pilot).

14 SOLAR ENERGY↗

Development of an AC Module System: Final Technical Report

The GreenRay Inc. program focused on simplifying solar electricity and making it affordable and accessible to the mainstream population. This was accomplished by integrating a solar module, micro-inverter, mounting and monitoring into a reliable, 'plug and play' AC system for residential rooftops, offering the following advantages: (1) Reduced Cost: Reduction in installation labor with fewer components, faster mounting, faster wiring. (2) Maximized Energy Production: Each AC Module operates at its maximum, reducing overall losses from shading, mismatch, or module downtime. (3) Increased Safety. Electrical and fire safety experts agree that AC Modules have significant benefits, with no energized wiring or live connections during installation, maintenance or emergency conditions. (4) Simplified PV for a Broader Group of Installers. Dramatic simplification of design and installation of a solar power system, enabling faster and more efficient delivery of the product into the market through well-established, mainstream channels. This makes solar more accessible to the public. (5) Broadened the Rooftop Market: AC Modules enable solar for many homes that have shading, split roofs, or obstructions. In addition, due to the smaller building block size of 200W vs. 1000W, homeowners with budget limitations can start small and add to their systems over time. Through this DOE program GreenRay developed the all-in-one AC Module system with an integrated PV Module and microinverter, custom residential mounting and performance monitoring. Development efforts took the product from its initial concept, through prototypes, to a commercial product sold and deployed in the residential market. This pilot deployment has demonstrated the technical effectiveness of the AC Module system in meeting the needs and solving the problems of the residential market. While more expensive than the traditional central inverter systems at the pilot scale, the economics of AC Modules become more and more favorable as the product matures and is made in high volumes. GreenRay's early customers have been highly enthusiastic about the AC Module system benefits.

14 SOLAR ENERGY↗

Retrofit of a Multifamily Mass Masonry Building in New England

Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗