Machine Learning Based Cavity Fault Classification and Prediction

We report on the development of machine learning models for classifying C100 superconducting radio frequency (SRF) cavity faults in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. CEBAF is a continuous-wave recirculating linac utilizing 418 SRF cavities to accelerate electrons up to 12 GeV through 5-passes. Of these, 96 cavities (12 cryomodules) are designed with a digital low-level RF system configured such that a cavity fault triggers waveform recordings of 17 RF signals for each of the eight cavities in the cryomodule. Subject matter experts (SME) can analyze the collected time-series data, identify which of the eight cavities faulted first, and classify the type of fault. This information is used to find trends and strategically deploy mitigations to problematic cryomodules. However, manually labeling the data is laborious and time-consuming. By leveraging machine learning, near real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type has been implemented. We discuss the performance of the ML models during a recent physics run.

43 PARTICLE ACCELERATORS↗

Super-Schottky mixer performance at 92 GHz

As part of a program to investigate the behavior of superconducting Schottky mixers at high frequencies, the mixing and video performance of several super-Schottky diodes (a 3-micron active diameter, and a doping concentration of 2 x 10 to the 19th per cu cm) have been tested at 92 GHz. At 92 GHz, video responsivities were typically 80 A/W (corrected for RF mismatch). Conversion loss (corrected for both RF and IF mismatches) was typically not less than 18 dB. As expected, diode temperature was low (less than 5 K). Video responsivity and conversion loss were also measured at an RF frequency of 3.95 GHz. These data were used with the measured volt-ampere characteristics of the diodes to compare theoretical predictions of diode performance at 92 GHz, in both the video and mixing modes, with the high-frequency data

Dickman, R. L.↗

Residual loss due to magnetic flux trapping in niobium superconducting microwave cavities

One of the significant source of radio frequency loss in superconducting microwave cavities is the trapped residual magnetic field during the cooldown due to the incomplete Messier effect. The sensitivity of flux trapping depends on the distribution of impurities, network of dislocations and defects which pin vortices. Recent advancement in cavity processing techniques resulted in very high quality factors with impurity doping, however the rf loss related to the flux trapping increases. High quality factor in SRF cavities is not only limited to particle accelerators but also emerging as an application to quantum computing and quantum information science. In this presentation, we present the results of measurements of flux trapping sensitivity on several 1.3 GHz elliptical accelerating cavities with different grain size, impurity content and surface preparations.

Dhakal, P.↗

A reactive ferroelectric tuner for microphonics compensation

Jefferson Lab (JLab) is actively pursuing an extensive research program focused on developing advanced Nb₃Sn superconducting technology for particle accel-eration. Due to the brittle nature of Nb₃Sn coatings, a Ferroelectric Tuner (FRT) currently represents the most viable approach for microphonics compensation in these next-generation cavities. We suggest a novel, fast-responding FRT integrated directly into the main coupler, eliminating the need for an additional RF port. Leveraging a unique RF design based on a magic-T configuration, this advanced FRT will enable micro-phonics compensation in the ±30 Hz range without undesirable changes to the external quality factor.

Accelerator Physics↗

A reactive ferroelectric tuner for microphonics compensation

Jefferson Lab (JLab) is actively pursuing an extensive research program focused on developing advanced Nb₃Sn superconducting technology for particle accel-eration. Due to the brittle nature of Nb₃Sn coatings, a Ferroelectric Tuner (FRT) currently represents the most viable approach for microphonics compensation in these next-generation cavities. We suggest a novel, fast-responding FRT integrated directly into the main coupler, eliminating the need for an additional RF port. Leveraging a unique RF design based on a magic-T configuration, this advanced FRT will enable micro-phonics compensation in the ±30 Hz range without undesirable changes to the external quality factor.

Accelerator Physics↗

Controlled Growth of Ta Oxide With Reactive Sputtering for Overlap Josephson Junction Application

Josephson junctions $\($JJs$\)$ are indispensable elements for superconducting quantum electronics. There is a growing need to develop processes for high quality JJs. Here we explore the growth of Ta oxide as a dielectric barrier for Metal-Oxide-Metal overlap JJ implementations. We study films of Ta oxides prepared with reactive magnetron sputtering. TaOx is grown on silicon and Ta films with varying RF power and oxygen concentrations. Tuning these parameters allows us to control the rate of deposition as well as composition of polycrystalline Ta oxides needed to meet our dielectric requirements for Josephson Junctions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compact Multicell Superconducting Crab Cavity for ILC

We propose a novel design of a crab cavity (CC) for the ILC project with low parasitic High Order Modes (HOM) losses and preserving the beam emittance, which is critical for operation with high beam current intensity. Multiple electrodes immersed in the hollow waveguide form a trapped-mode resonator. The transverse components of the electromagnetic field of the trapped dipole mode induce a transverse kick and efficiently deflect charged particles passing through the cavity. We present a scalable design of a superconducting Quasi-waveguide Multicell Resonator (QMiR) seamlessly connected with a beam vacuum chamber. The cavity is completely open at both ends, which significantly reduces the maximum loaded quality factor of the higher order modes (HOM), avoids complex HOM couplers, and thus simplifies the mechanical design of the cavity. The same port is used to feed RF power to the operating mode and to extract the same order modes (SOM). Finally, we estimate the expected cryogenic losses, HOM impedance limits, RF input power required, and frequency tuning for a QMiR cavity designed to operate at 2.6 GHz.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Space charge dominated momentum spread and compensation strategies in the post-linac section of Proton Improvement Plan-II at Fermilab

The upcoming Proton Improvement Plan-II (PIP-II), designated for enhancements to the Fermilab accelerator complex, features a new 800 MeV superconducting linac and a Beam Transfer Line (BTL) to transport the beam to the existing Booster synchrotron. To mitigate the space charge tune shift associated with a high intensity accumulated beam, the low emittance linac beam is used to paint the ring phase space both transversely and longitudinally. To prevent losses caused by particles injected outside the rf separatrix while painting longitudinal phase space, the momentum spread of the incoming beam should not exceed 2.1 x 10^-4. Detailed simulations showed that due to space charge, the rms momentum spread increases to 4 x 10^-4 while it is transported in the BTL --about twice the allowable limit. In this paper, we outline a mitigation strategy involving a debuncher cavity. We discuss location, operating frequency, and gap voltage under both nominal and perturbed beam conditions, specifically accounting for momentum jitter. The impact of cavity misalignments is also assessed. The paper concludes by recommending an optimized configuration.

43 PARTICLE ACCELERATORS↗

Superconducting Mixers for Far-Infrared Spectroscopy

The goal of this project was to fabricate and test planar arrays of superconducting mixers for the 2-6 THz band. The technology is intended for multi-beam receivers aboard Explorer-class missions and the SOFIA Airborne Observatory. The mixer technology is the superconducting transition-edge microbolometer, which is more commonly known as the Hot-Electron micro-Bolometer (HEB). As originally proposed, two superconducting technologies were to be developed: (1) low-Tc niobium HEBs which could approach quantum-noise-limited sensitivities but require cooling to 2- 4 K, and (2) high-Tc YBCO HEBs with sensitivities 10 times worse but with a relaxed cooling requirement of 30-60 K. The low-Tc devices would be best for astronomy applications on SOFIA, whereas the high-Tc devices would be more suitable for planetary missions using systems without stored cryogens. The work plan called for planar micro-fabrication and initial testing of HEB devices at the NIST Boulder clean-room facility. Subsequent assembly and RF testing of selected devices would be done at the CASA laboratory at U. Colorado. Approximately 1-year after work began on this project, Dr. Eyal Gerecht joined the NIST group, and assumed day-to-day responsibility for Nb-HEB development at NIST outside of micro-fabrication. The YBCO-HEB work was to be guided by Dr. Ron Ono, who was the NIST expert in YBCO technology. Unfortunately, recurrent health problems limited the time Ron could devote to the project in its first year. These problems became aggravated in early 2001, and sadly led to Ron's death in October, 2001. His loss was not only a blow to his friends and associates at NIST, but was mounted by the US superconductivity community at large. With his passing, work on high-Tc HEBs ceased at NIST. There was no one to replace him or his expertise. Our work subsequently shifted solely to Nb-HEB devices. In the sections which follow, our progress in the development of diffusion-cooled Nb-HEB mixers is detailed. To simplify the terminology, these devices will subsequently be called DHEB mixers to distinguish them from phonon-cooled devices (PHEBs).

Betz, A. L.↗

Analysis of Low RRR SRF Cavities

Recent findings in the superconducting radio-frequency (SRF) community have shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. Success has been found in nitrogen-doping, diffusion of the native oxide into the niobium surface, and thin films of alternate superconductors atop a niobium bulk cavity. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of recent impurity-based improvements can be better understood and improved upon. Additionally, we perform a low temperature bake on the low RRR cavity to evaluate how the intentional addition of oxygen to the RF layer affects performance. We have found that low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. The results of this study have the potential to unlock a new understanding on SRF materials.

43 PARTICLE ACCELERATORS↗

Analysis of Low RRR SRF Cavities

Recent findings in the superconducting radio-frequency (SRF) community have shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. Success has been found in nitrogen-doping, diffusion of the native oxide into the niobium surface, and thin films of alternate superconductors atop a niobium bulk cavity. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of recent impurity-based improvements can be better understood and improved upon. Additionally, we performed surface treatments, low temperature baking and nitrogen-doping, on low RRR cavities to evaluate how the intentional addition of more impurities to the RF layer affects performance. We have found that low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. The results of this study have the potential to unlock a new understanding on SRF materials.

43 PARTICLE ACCELERATORS↗

Antenna-Coupled Superconducting Tunnel Junctions with Single-Electron Transistor Readout for Detection of Sub-mm Radiation

Antenna-coupled superconducting tunnel junction detectors have the potential for photon-counting sensitivity at sub-mm wavelengths. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Design of Stand-Alone Cryomodule based on Superconducting Quarter-Wave Resonator

Present superconducting accelerators require a central refrigeration system and piping to distribute liquid helium and nitrogen. Stand-alone cryocooler-based systems are of significant interest both to scientific and industrial customers, as they allow applications at facilities where no cryogenic equipment and expertise exists, where it is undesirable to develop additional cryogenic systems, or where a mobile system that can be transported between beamlines or facilities is required. The technical challenge of this approach is to minimize the heat losses to the liquid helium so that commercially available, self-contained cryocoolers are able to handle the thermal load. This paper presents an improved design for a stand-alone quarter-wave resonator (QWR) cryomodule a based on commercially available cryocoolers. This cryomodule has a particular application in the ATLAS intensity upgrade project where it will house a 72.75 MHz QWR for beam energy adjustments to experimental areas, where no helium cryogenic systems exist. The described cryomodule may also be the critical part of a turnkey system with application to material processing, semiconductor manufacturing, food irradiation and homeland security. The development of low heat loss peripheral components reduces cost and widens applicability of the system. We will discuss the cryomodule and RF coupler designs, including numerical thermal and structural analyses.

43 PARTICLE ACCELERATORS↗

Possible unconventional order parameter in single crystals of SrPt 3 P superconductor

Here, anisotropic properties of single crystals of SrPt 3 P were studied using London penetration depth and electrical resistivity measurements. The upper critical field, $H_{c2}(T)$, was determined from four-probe electrical resistivity measurements for three orthogonal directions of a magnetic field with respect to the crystal. The London penetration depth, $λ(T)$, was determined from the magnetic susceptibility of the Meissner–London state measured using a tunnel-diode resonator technique. Whereas $H_{c2}(T)$ and the normal-state $ρ(T)$ are practically identical for all three magnetic field orientations, the London penetration depth shows significant unidirectional anisotropy. The low-temperature $λ(T)$ is exponentially attenuated when a small excitation radiofrequency magnetic field, $H_{rf}$, is applied along the c"-direction, in which case screening currents flow in the a"b"-plane, while for the other two orientations, $H_{rf}$∥ a" and $H_{rf}$ ∥ b", the London penetration depth shows a much stronger, $λ(T)$ ~ T 2 , variation. Such unusual and contrasting behavior of the two anisotropies, $γ_{H}$(T) = $H_{c2}$/$H_{c2,c}$ = $ξ_{ab}$/$ξ_{c}$ and $γ_{λ}$(T) = $λ_{c}$\$λ_{ab'}$, imposes significant constraints on the possible order parameter. Although our measurements are insufficient to derive conclusively the superconducting gap anisotropy, the order parameter with two point nodes and a modulation in the perpendicular direction is qualitatively consistent with the experimental observations.

anisotropic superconducting gap↗

The cyclotron gas stopper at FRIB getting ready for operations

Linear gas stopping cells have been used for nearly two decades to slow down projectile fragments at the National Superconducting Cyclotron Laboratory, now the Facility for Rare Isotope Beams, for experiments with low-energy and reaccelerated beams. In order to efficiently stop and rapidly extract light to medium-mass fast ions, a cyclotron gas-stopper has been constructed. It uses a cyclotron-type magnet and a helium-gas filled stopping chamber to slow down the injected beam. RF ion guides transport the stopped ions to the center of the magnet and axially through the bore before acceleration to <60 keV. Following successful offline tests, the cyclotron stopper was moved to an experimental vault and connected to a new momentum–compression beam line. Beam transport to and into the cyclotron stopper was tested with stable beams. Finally, using 46 K fragments, the first successful stopping and extraction of a high-energy beam with the cyclotron stopper was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Oak Ridge National Laboratory spallation neutron source proton power upgrade cavities and cryomodule production

The Proton Power Upgrade initiative at Oak Ridge National Lab’s Spallation Neutron Source aims to greatly boost the capability of proton beam power. This upgrade involves the integration of seven additional cryomodules, each housing four six-cell high-beta ( β = 0.81 ) superconducting radio frequency cavities. These cavities, manufactured and processed by Research Instruments in Germany, underwent meticulous treatment, including electropolishing as the bulk and final vital step. Upon delivery to Jefferson Lab, a total of 28 cavities for seven cryomodules, along with an additional four cavities for a spare cryomodule, underwent thorough vertical qualification tests, meeting the required specifications. Following cavity tanking and subsequent rf testing, the assembly of eight cryomodules was successfully executed, with all 32 cavities demonstrating compliance with acceptance criteria. The transportation of the cryomodule to SNS for high-power testing in the tunnel yielded exceptional results. Notably, the performance surpassed specifications, in terms of quality factor and accelerating gradient. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Design of axion and axion dark matter searches based on ultra high Q SRF cavities

The Superconducting Quantum Materials and Systems center is developing searches for dark photons, axions and ALPs with the goal of improving upon the current state-of-the-art sensitivity. These efforts leverage on Fermi National Accelerator expertise on ultra-high quality factor superconducting radio frequency cavities combined with the center research on quantum technology. Here we focus on multiple axion searches that utilize ~1E10 quality factor superconducting radio frequency cavities and their resonant modes to enhance the production and/or detection of axions in the cavity volume. In addition, we present preliminary results of single-mode and multi-mode nonlinearity measurements that were carried out as part of an experimental feasibility study to gain insight on the behavior of the ultra-high quality factor resonators and the experimental RF system in the regime relevant for axion searches.

43 PARTICLE ACCELERATORS↗