Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECTUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Short- and Long-Term Quality of Life and Bowel Function in Patients With MRI-Defined, High-Risk, Locally Advanced Rectal Cancer Treated With an Intensified Neoadjuvant Strategy in the Randomized Phase 2 EXPERT-C Trial

Objective: Intensified preoperative treatments have been increasingly investigated in locally advanced rectal cancer (LARC), but limited data are available for the impact of these regimens on quality of life (QoL) and bowel function (BF). We assessed these outcome measures in EXPERT-C, a randomized phase 2 trial of neoadjuvant capecitabine combined with oxaliplatin (CAPOX), followed by chemoradiation therapy (CRT), total mesorectal excision, and adjuvant CAPOX with or without cetuximab in magnetic resonance imaging-defined, high-risk LARC. Methods and Materials: QoL was assessed using the European Organization for Research and Treatment of Cancer QLQ-C30 and QLQ-CR29 questionnaires. Bowel incontinence was assessed using the modified Fecal Incontinence Severity Index questionnaire. Results: Compared to baseline, QoL scores during preoperative treatment were better for symptoms associated with the primary tumor in the rectum (blood and mucus in stool, constipation, diarrhea, stool frequency, buttock pain) but worse for global health status, role functioning, and symptoms related to the specific safety profile of each treatment modality. During follow-up, improved emotional functioning and lessened anxiety and insomnia were observed, but deterioration of body image, increased urinary incontinence, less sexual interest (men), and increased impotence and dyspareunia were observed. Cetuximab was associated with a deterioration of global health status during neoadjuvant chemotherapy but did not have any long-term detrimental effect. An improvement in bowel continence was observed after preoperative treatment and 3 years after sphincter-sparing surgery. Conclusions: Intensifying neoadjuvant treatment by administering induction systemic chemotherapy before chemoradiation therapy improves tumor-related symptoms and does not appear to have a significantly detrimental effect on QoL and BF, in both the short and the long term.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy

Purpose: To assess the impact of approximations in current analytical dose calculation methods (ADCs) on tumor control probability (TCP) in proton therapy. Methods: Dose distributions planned with ADC were compared with delivered dose distributions as determined by Monte Carlo simulations. A total of 50 patients were investigated in this analysis with 10 patients per site for 5 treatment sites (head and neck, lung, breast, prostate, liver). Differences were evaluated using dosimetric indices based on a dose-volume histogram analysis, a γ-index analysis, and estimations of TCP. Results: We found that ADC overestimated the target doses on average by 1% to 2% for all patients considered. The mean dose, D95, D50, and D02 (the dose value covering 95%, 50% and 2% of the target volume, respectively) were predicted within 5% of the delivered dose. The γ-index passing rate for target volumes was above 96% for a 3%/3 mm criterion. Differences in TCP were up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head and neck, and lung patients, respectively. Differences in normal tissue complication probabilities for bladder and anterior rectum of prostate patients were less than 3%. Conclusion: Our results indicate that current dose calculation algorithms lead to underdosage of the target by as much as 5%, resulting in differences in TCP of up to 11%. To ensure full target coverage, advanced dose calculation methods like Monte Carlo simulations may be necessary in proton therapy. Monte Carlo simulations may also be required to avoid biases resulting from systematic discrepancies in calculated dose distributions for clinical trials comparing proton therapy with conventional radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial

Purpose: To test the hypothesis that multileaf collimator (MLC) tracking improves the consistency between the planned and delivered dose compared with the dose without MLC tracking, in the setting of a prostate cancer volumetric modulated arc therapy trial. Methods and Materials: Multileaf collimator tracking was implemented for 15 patients in a prostate cancer radiation therapy trial; in total, 513 treatment fractions were delivered. During each treatment fraction, the prostate trajectory and treatment MLC positions were collected. These data were used as input for dose reconstruction (multiple isocenter shift method) to calculate the treated dose (with MLC tracking) and the dose that would have been delivered had MLC tracking not been applied (without MLC tracking). The percentage difference from planned for target and normal tissue dose-volume points were calculated. The hypothesis was tested for each dose-volume value via analysis of variance using the F test. Results: Of the 513 fractions delivered, 475 (93%) were suitable for analysis. The mean difference and standard deviation between the planned and treated MLC tracking doses and the planned and without-MLC tracking doses for all 475 fractions were, respectively, PTV D{sub 99%} −0.8% ± 1.1% versus −2.1% ± 2.7%; CTV D{sub 99%} −0.6% ± 0.8% versus −0.6% ± 1.1%; rectum V{sub 65%} 1.6% ± 7.9% versus −1.2% ± 18%; and bladder V{sub 65%} 0.5% ± 4.4% versus −0.0% ± 9.2% (P<.001 for all dose-volume results). Conclusion: This study shows that MLC tracking improves the consistency between the planned and delivered doses compared with the modeled doses without MLC tracking. The implications of this finding are potentially improved patient outcomes, as well as more reliable dose-volume data for radiobiological parameter determination.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrogel Spacer Prospective Multicenter Randomized Controlled Pivotal Trial: Dosimetric and Clinical Effects of Perirectal Spacer Application in Men Undergoing Prostate Image Guided Intensity Modulated Radiation Therapy

Purpose: Perirectal spacing, whereby biomaterials are placed between the prostate and rectum, shows promise in reducing rectal dose during prostate cancer radiation therapy. A prospective multicenter randomized controlled pivotal trial was performed to assess outcomes following absorbable spacer (SpaceOAR system) implantation. Methods and Materials: Overall, 222 patients with clinical stage T1 or T2 prostate cancer underwent computed tomography (CT) and magnetic resonance imaging (MRI) scans for treatment planning, followed with fiducial marker placement, and were randomized to receive spacer injection or no injection (control). Patients received postprocedure CT and MRI planning scans and underwent image guided intensity modulated radiation therapy (79.2 Gy in 1.8-Gy fractions). Spacer safety and impact on rectal irradiation, toxicity, and quality of life were assessed throughout 15 months. Results: Spacer application was rated as “easy” or “very easy” 98.7% of the time, with a 99% hydrogel placement success rate. Perirectal spaces were 12.6 ± 3.9 mm and 1.6 ± 2.0 mm in the spacer and control groups, respectively. There were no device-related adverse events, rectal perforations, serious bleeding, or infections within either group. Pre-to postspacer plans had a significant reduction in mean rectal V70 (12.4% to 3.3%, P<.0001). Overall acute rectal adverse event rates were similar between groups, with fewer spacer patients experiencing rectal pain (P=.02). A significant reduction in late (3-15 months) rectal toxicity severity in the spacer group was observed (P=.04), with a 2.0% and 7.0% late rectal toxicity incidence in the spacer and control groups, respectively. There was no late rectal toxicity greater than grade 1 in the spacer group. At 15 months 11.6% and 21.4% of spacer and control patients, respectively, experienced 10-point declines in bowel quality of life. MRI scans at 12 months verified spacer absorption. Conclusions: Spacer application was well tolerated. Increased perirectal space reduced rectal irradiation, reduced rectal toxicity severity, and decreased rates of patients experiencing declines in bowel quality of life. The spacer appears to be an effective tool, potentially enabling advanced prostate RT protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Outcomes of Computed Tomography–Based Volumetric Brachytherapy Planning for Cervical Cancer

Purpose/Objectives: A report of clinical outcomes of a computed tomography (CT)-based image guided brachytherapy (IGBT) technique for treatment of cervical cancer. Methods and Materials: Seventy-six women with International Federation of Gynecology and Obstetrics stage IB to IVA cervical carcinoma diagnosed between 2007 and 2014 were treated with definitive external beam radiation therapy (EBRT) with or without concurrent chemotherapy followed by high-dose-rate (HDR) IGBT. All patients underwent planning CT simulation at each implantation. A high-risk clinical target volume (HRCTV) encompassing any visible tumor and the entire cervix was contoured on the simulation CT. When available, magnetic resonance imaging (MRI) was performed at implantation to assist with tumor delineation. The prescription dose was prescribed to the HRCTV. Results: The median follow-up time was 17 months. Thirteen patients (17%) had an MRI done before brachytherapy, and 16 patients (21%) were treated without MRI guidance. The mean EBRT/IGBT sum 2-Gy equivalent dose (EQD2) delivered to the 90% volume of the HRCTV was 86.3 Gy. The mean maximum EQD2s delivered to 2 cm{sup 3} of the rectum, sigmoid, and bladder were 67.5 Gy, 66.2 Gy, and 75.3 Gy, respectively. The 2-year cumulative incidences of local, locoregional, and distant failure were 5.8% (95% confidence interval [CI]: 1.4%-14.8%), 15.1% (95% CI: 5.4%-29.4%), and 24.3% (95% CI: 12.1%-38.9%), respectively. The 2-year overall and disease-free survival rates were 75% (95% CI, 61%-91%) and 73% (95% CI, 60%-90%), respectively. Twenty-nine patients (38%) experienced grade ≥2 acute toxicity, with 5 cases of acute grade 3 toxicity and no grade ≥4 toxicities. One patient experienced grade 3 gastrointestinal toxicity. No other late grade ≥3 events were observed. Conclusions: This is the largest report to date of CT/MRI-based IGBT for the treatment of cervical cancer. The results are promising, with excellent local control and acceptable toxicity. Further investigation is needed to assess the long-term safety and efficacy of this treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive Parameters of Symptomatic Hematochezia Following 5-Fraction Gantry-Based SABR in Prostate Cancer

Purpose: This study identified predictors of high-grade late hematochezia (HH) following 5-fraction gantry-based stereotactic ablative radiation therapy (SABR). Methods and Materials: Hematochezia data for 258 patients who received 35 to 40 Gy SABR in 5-fractions as part of sequential phase 2 prospective trials was retrieved. Grade 2 or higher late rectal bleeding was labeled HH. Hematochezia needing steroid suppositories, 4% formalin, or 1 to 2 sessions of argon plasma coagulation (APC) was labeled grade 2. More than 2 sessions of APC, blood transfusion, or a course of hyperbaric oxygen was grade 3 and development of visceral fistula, grade 4. Various dosimetric and clinical factors were analyzed using univariate and multivariate analyses. Receiver operating characteristic (ROC) curve analysis and recursive partitioning analysis were used to determine clinically valid cut-off points and identify risk groups, respectively. Results: HH was observed in 19.4%, grade ≥3 toxicity in 3.1%. Median follow-up was 29.7 months (interquartile range [IQR]: 20.6-61.7) Median time to develop HH was 11.7 months (IQR: 9.0-15.2) from the start of radiation. At 2 years, cumulative HH was 4.9%, 27.2%, and 42.1% in patients who received 35 Gy to prostate (4-mm planning target volume [PTV] margin), 40 Gy to prostate (5-mm PTV margin), and 40 Gy to prostate/seminal vesicles (5-mm PTV margin), respectively (P<.0001). In the ROC analysis, volume of rectum receiving radiation dose of 38 Gy (V38) was a strong predictor of HH with an area under the curve of 0.65. In multivariate analysis, rectal V38 (≥2.0 cm{sup 3}; odds ratio [OR]: 4.7); use of anticoagulants in the follow-up period (OR: 6.5) and presence of hemorrhoids (OR: 2.7) were the strongest predictors. Recursive partitioning analysis showed rectal V38 < 2.0 cm{sup 3}, and use of anticoagulants or rectal V38 ≥ 2.0 cm{sup 3} plus 1 other risk factor resulted in an HH risk of >30%. Conclusions: Rectal V38 and 2 clinical factors were strong predictors of HH following 5-fraction SABR. Planning constraints should keep rectal V38 below 2.0 cm{sup 3}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can We Advance Proton Therapy for Prostate? Considering Alternative Beam Angles and Relative Biological Effectiveness Variations When Comparing Against Intensity Modulated Radiation Therapy

Purpose: For prostate treatments, robust evidence regarding the superiority of either intensity modulated radiation therapy (IMRT) or proton therapy is currently lacking. In this study we investigated the circumstances under which proton therapy should be expected to outperform IMRT, particularly the proton beam orientations and relative biological effectiveness (RBE) assumptions. Methods and Materials: For 8 patients, 4 treatment planning strategies were considered: (A) IMRT; (B) passively scattered standard bilateral (SB) proton beams; (C) passively scattered anterior oblique (AO) proton beams, and (D) AO intensity modulated proton therapy (IMPT). For modalities (B)-(D) the dose and linear energy transfer (LET) distributions were simulated using the TOPAS Monte Carlo platform and RBE was calculated according to 3 different models. Results: Assuming a fixed RBE of 1.1, our implementation of IMRT outperformed SB proton therapy across most normal tissue metrics. For the scattered AO proton plans, application of the variable RBE models resulted in substantial hotspots in rectal RBE weighted dose. For AO IMPT, it was typically not possible to find a plan that simultaneously met the tumor and rectal constraints for both fixed and variable RBE models. Conclusion: If either a fixed RBE of 1.1 or a variable RBE model could be validated in vivo, then it would always be possible to use AO IMPT to dose-boost the prostate and improve normal tissue sparing relative to IMRT. For a cohort without rectum spacer gels, this study (1) underlines the importance of resolving the question of proton RBE within the framework of an IMRT versus proton debate for the prostate and (2) highlights that without further LET/RBE model validation, great care must be taken if AO proton fields are to be considered for prostate treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance–Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation

Purpose: To evaluate the feasibility of magnetic resonance–guided high-intensity focused ultrasound (MR-HIFU) mild hyperthermia in deep tissue targets for enhancing radiation therapy and chemotherapy in the context of recurrent rectal cancer. A preclinical study was performed to evaluate the safety and performance of MR-HIFU mild hyperthermia. A prospective imaging study was performed in volunteers with rectal cancer to evaluate MR thermometry quality near the rectum and accessibility of rectal tumors using MR-HIFU. Methods and Materials: Mild hyperthermia was performed in pig thigh (9 sonications, 6 pigs) using a clinical MR-HIFU system. Targets near the rectal wall and deep thigh were evaluated. Thermal maps obtained in 6 planes every 3.2 seconds were used to control sonications in 18-mm diameter treatment regions at temperatures of 42°C to 42.5°C for 10 to 60 minutes. Volunteer imaging-only studies to assess the quality of MR thermometry (without heating) were approved by the institutional research ethics board. Anatomic and MR thermometry images were acquired in consenting volunteers with rectal cancer. In 3 of 6 study participants, rectal filling with saline was used to reduce motion-related MR thermometry artifacts near the tumor. Results: In pigs, mean target temperature matched the desired hyperthermia temperature within 0.2°C; temporal standard deviation ≤0.5°C. With optimized control thresholds, no undesired tissue damage was observed. In human volunteers, MR temperature measurements had adequate precision and stability, especially when rectal filling was used to reduce bowel motion. Conclusions: In pigs, MR-HIFU can safely deliver mild hyperthermia (41°C-43°C) to a targeted volume for 30 minutes. In humans, careful patient selection and preparation will enable adequate targeting for recurrent rectal cancers and sufficient MR temperature mapping stability to control mild hyperthermia. These results enable human trials of MR-HIFU hyperthermia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy in the Management of Operable Rectal Cancer: A Systematic Review

Purpose: To evaluate the role of high-dose-rate endorectal brachytherapy (HDREBT) in the preoperative and definitive management of operable rectal cancer in terms of clinical outcomes and toxicities using a systematic review. Methods and Materials: A review of published articles from January 1990 to December 2016 was conducted using the PubMed, Embase, and Scopus databases using the search terms “rectal” or “rectum” in combination with “brachytherapy,” “high dose rate,” “HDR,” and “endorectal.” Additional publications were identified by scanning references. Only studies published in English reporting clinical outcomes with ≥30 patients treated with HDREBT were included. Results: The search identified 1688 articles, of which 22 met our inclusion criteria. Twelve studies were included in this systematic review. Following preoperative HDREBT with chemoradiation therapy (CRT), the pathologic complete response (pCR) rate ranged between 18% and 31% (weighted mean rate, 22.2%); R0 resection rate, between 80% and 99% (weighted mean rate, 95.5%); and sphincter-preservation rate, between 29% and 54% (weighted mean rate, 46.4%). The weighted mean 2-year progression-free survival and overall survival (OS) rates were 68.1% and 81.5%, respectively. After preoperative HDREBT alone, the pCR rate ranged between 10.4% and 27% (weighted mean rate, 23.8%), the R0 rate was 96.5% (1 study), and the sphincter-preservation rate ranged between 53.8% and 75.8% (weighted mean rate, 59.4%). The weighted mean 5-year progression-free survival and OS rates were 66.6% and 70.8%, respectively. There was only 1 study of HDREBT for nonsurgical management of rectal cancer, which reported a 2-year OS rate of 100%. Conclusions: Preoperative HDREBT either alone or in combination with CRT may result in a better pCR but may not necessarily translate into better survival, which is similar to outcomes seen following preoperative CRT alone. There were significant variations across studies in terms of patient selection, treatment approaches, and evaluation of clinical outcomes, suggesting the need for an international consensus on the dosimetric parameters and techniques of HDREBT, timing and methods of response assessment, definitions and assessment of toxicities, and optimal timing of surgery before further prospective studies. Future studies should include evaluation of the role of HDREBT in the nonsurgical curative treatment of screen-detected early cancers and organ preservation in lower rectal cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Preliminary Evaluation of a Murine Model of Chronic Radiation-Induced Proctitis

Radiotherapy (RT) is commonly used to treat most pelvic malignancies. While treatment is often effective, curative radiation doses to the rectum can result in chronic radiation-induced proctitis, which is characterized by diarrhea, tenesmus, and/or rectal bleeding, recently termed pelvic radiation disease. An animal model of chronic radiation-induced proctitis would be useful to test both preventative and therapeutic strategies to limit this morbidity but has been elusive because of the high rodent mortality associated with acute bowel RT injury. The objective of this research was to develop a novel mouse model of chronic radiation-induced proctitis using advanced technology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Rectal Dose-volume Histogram Variation in Prostate Intensity-modulated Radiation Therapy: Is It Clinically Significant in the Era of Image Guidance?

Because of the steep dose gradient associated with dose-escalated intensity-modulated radiation therapy, interfraction motion and variation in rectal volume may result in the rectum receiving a larger dose than predicted at treatment planning. This study aims to quantify the variation in daily rectal dose-volume histograms (DVHs) from the treatment plan and to discuss the potential clinical significance of this variation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the Psychological Impact of Daily Bowel Preparation on Prostate Patients Who Receive Radiation Therapy

Evidence has shown that the prostate moves depending on filling of the rectum and, to a lesser extent, the bladder; many radiation therapy departments have adopted standardized bladder filling/rectal emptying protocols for radiotherapy treatment. Daily treatments may be delayed until appropriate volumes are attained; the resultant psychological impact of these delays on patients is unknown. The purpose of this study was to determine levels of anxiety, depression, distress, and bother related to bowel preparation for prostate cancer patients undergoing radiation therapy treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of IMRT to Cover Pelvic Nodes While Escalating the Dose to the Prostate Gland: Dosimetric Data on 35 Consecutive Patients

Utilizing available dosimetric and acute toxicity data, we confirm the feasibility of intensity modulated radiotherapy (IMRT) to include treatment of the pelvic nodes (PN) while escalating the dose to the prostate. Data were obtained from 35 consecutive patients with prostate cancer with {>=}15% risk of PN involvement. Patients received an initial boost to the prostate, delivering 16 Gy over 8 fractions using a 6-field conformal technique, followed by an 8-field coplanar inverse planning IMRT technique delivering an additional 60 Gy over 30 fractions to the prostate (76 Gy total) and 54 Gy over 30 fractions to the seminal vesicles (SV) and PN. Dose-volume histogram analysis was performed for planning target volumes and organs at risk. Acute toxicity (RTOG/EORTC scale) was prospectively and independently scored weekly for each patient. The maximum, mean, minimum dose, and D95 to each planning target volume is provided: prostate (82.2, 78.2, 72.6, 75.2 Gy), SV (79.0, 72.5, 56.9, 61.1 Gy), and PN (80.4, 59.7, 46.5, 53.3 Gy), respectively. The percent volume receiving a dose at or above 'x' Gy (Vx) was recorded for V75, V70, V65, V60, and V50 as: bladder (14%, 24%, 32%, 39%, and 54%) and rectum (3%, 18%, 26%, 34%, and 51%), respectively. Acute toxicity was as follows: 54% grade 2+ GI (n = 19), 25% grade 2+ GU (n = 9). IMRT enables treatment of pelvic nodes while escalating dose to the prostate and is clinically feasible with acute toxicity within expected ranges.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiobiological Impact of Reduced Margins and Treatment Technique for Prostate Cancer in Terms of Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP)

Dose escalation in prostate radiotherapy is limited by normal tissue toxicities. The aim of this study was to assess the impact of margin size on tumor control and side effects for intensity-modulated radiation therapy (IMRT) and 3D conformal radiotherapy (3DCRT) treatment plans with increased dose. Eighteen patients with localized prostate cancer were enrolled. 3DCRT and IMRT plans were compared for a variety of margin sizes. A marker detectable on daily portal images was presupposed for narrow margins. Prescribed dose was 82 Gy within 41 fractions to the prostate clinical target volume (CTV). Tumor control probability (TCP) calculations based on the Poisson model including the linear quadratic approach were performed. Normal tissue complication probability (NTCP) was calculated for bladder, rectum and femoral heads according to the Lyman-Kutcher-Burman method. All plan types presented essentially identical TCP values and very low NTCP for bladder and femoral heads. Mean doses for these critical structures reached a minimum for IMRT with reduced margins. Two endpoints for rectal complications were analyzed. A marked decrease in NTCP for IMRT plans with narrow margins was seen for mild RTOG grade 2/3 as well as for proctitis/necrosis/stenosis/fistula, for which NTCP <7% was obtained. For equivalent TCP values, sparing of normal tissue was demonstrated with the narrow margin approach. The effect was more pronounced for IMRT than 3DCRT, with respect to NTCP for mild, as well as severe, rectal complications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Treatment and Dosimetric Advantages Between VMAT, IMRT, and Helical TomoTherapy in Prostate Cancer

We investigated the possible treatment and dosimetric advantage of volumetric modulated arc therapy (VMAT) over step-and-shoot intensity-modulated radiation therapy (step-and-hhoot IMRT) and helical tomotherapy (HT). Twelve prostate cancer patients undergoing VMAT to the prostate were included. Three treatment plans (VMAT, step-and-shoot IMRT, HT) were generated for each patient. The doses to clinical target volume and 95% of planning target volume were both {>=}78 Gy. Target coverage, conformity index, dose to rectum/bladder, monitor units (MU), treatment time, equivalent uniform dose (EUD), normal tissue complication probability (NTCP) of targets, and rectum/bladder were compared between techniques. HT provided superior conformity and significantly less rectal volume exposed to 65 Gy and 40 Gy, as well as EUD/NTCP of rectum than step-and-shoot IMRT, whereas VMAT had a slight dosimetric advantage over step-and-shoot IMRT. Notably, significantly lower MUs were needed for VMAT (309.7 {+-} 35.4) and step-and-shoot IMRT (336.1 {+-} 16.8) than for HT (3368 {+-} 638.7) (p < 0.001). The treatment time (minutes) was significantly shorter for VMAT (2.6 {+-} 0.5) than step-and-shoot IMRT (3.8 {+-} 0.3) and HT (3.8 {+-} 0.6) (p < 0.001). Dose verification of VMAT using point dose and film dosimetry met the accepted criteria. VMAT and step-and-shoot IMRT have comparable dosimetry, but treatment efficiency is significantly higher for VMAT than for step-and-shoot IMRT and HT.

61 RADIATION PROTECTION AND DOSIMETRY↗

RapidArc radiotherapy planning for prostate cancer: Single-arc and double-arc techniques vs. intensity-modulated radiotherapy

RapidArc is a novel technique using arc radiotherapy aiming to achieve intensity-modulated radiotherapy (IMRT)-quality radiotherapy plans with shorter treatment time. This study compared the dosimetric quality and treatment efficiency of single-arc (SA) vs. double-arc (DA) and IMRT in the treatment of prostate cancer. Fourteen patients were included in the analysis. The planning target volume (PTV), which contained the prostate gland and proximal seminal vesicles, received 76 Gy in 38 fractions. Seven-field IMRT, SA, and DA plans were generated for each patient. Dosimetric quality in terms of the minimum PTV dose, PTV hotspot, inhomogeneity, and conformity index; and sparing of rectum, bladder, and femoral heads as measured by V70, V-40, and V20 (% of volume receiving >70 Gy, 40 Gy, and 20 Gy, respectively), treatment efficiency as assessed by monitor units (MU) and treatment time were compared. All plan objectives were met satisfactorily by all techniques. DA achieved the best dosimetric quality with the highest minimum PTV dose, lowest hotspot, and the best homogeneity and conformity. It was also more efficient than IMRT. SA achieved the highest treatment efficiency with the lowest MU and shortest treatment time. The mean treatment time for a 2-Gy fraction was 4.80 min, 2.78 min, and 1.30 min for IMRT, DA, and SA, respectively. However, SA also resulted in the highest rectal dose. DA could improve target volume coverage and reduce treatment time and MU while maintaining equivalent normal tissue sparing when compared with IMRT. SA achieved the greatest treatment efficiency but with the highest rectal dose, which was nonetheless within tolerable limits. For busy units with high patient throughput, SA could be an acceptable option.

61 RADIATION PROTECTION AND DOSIMETRY↗

An evaluation of the contouring abilities of medical dosimetry students for the anatomy of a prostate cancer patient

Prostate cancer is one of the most common diseases treated in a radiation oncology department. One of the major predictors of the treatment outcome and patient side effects is the accuracy of the anatomical contours for the treatment plan. Therefore, the purpose of this study was to determine which anatomical structures are most often contoured correctly and incorrectly by medical dosimetry students. The author also wanted to discover whether a review of the contouring rules would increase contouring accuracy. To achieve this, a male computed tomography dataset consisting of 72 transverse slices was sent to students for contouring. The students were instructed to import this dataset into their treatment planning system and contour the following structures: skin, bladder, rectum, prostate, penile bulb, seminal vesicles, left femoral head, and right femoral head. Upon completion of the contours, the contour file was evaluated against a 'gold standard' contour set using StructSure software (Standard Imaging, Inc). A review of the initial contour results was conducted and then students were instructed to contour the dataset a second time. The results of this study showed significant differences between contouring sessions. These results and the standardization of contouring rules should benefit all individuals who participate in the treatment planning of cancer patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

A dosimetric evaluation of dose escalation for the radical treatment of locally advanced vulvar cancer by intensity-modulated radiation therapy

The purpose of this planning study was to determine whether intensity-modulated radiation therapy (IMRT) reduces the radiation dose to organs at risk (OAR) when compared with 3D conventional radiation therapy (3D-CRT) in patients with vulvar cancer treated by irradiation. This study also investigated the use of sequential IMRT boost (seq-IMRT) and simultaneous integrated boost (SIB-IMRT) for dose escalation in the treatment of locally advanced vulvar cancer. Five vulvar cancer patients treated in the postoperative setting and 5 patients treated with definitive intent (def-group) were evaluated. For the postoperative group, 3D-CRT and IMRT plans to a total dose (TD) of 45 Gy were generated. For the def-group, 4 plans were generated: a 3D-CRT and an IMRT plan to a TD of 56.4 Gy, a SIB-IMRT plan to a TD of 56 Gy, and a SIB-IMRT with dose escalation (SIB-IMRT-esc): TD of 67.2 Gy. Mean dose and dose-volume histograms were compared using Student's t-test. IMRT significantly (all p < 0.05) reduced the D{sub mean}, V30, and V40 for all OAR in the adjuvant setting. The V45 was also significantly reduced for all OAR except the bladder. For patients treated in the def-group, all IMRT techniques significantly reduced the D{sub mean}, V40, and V45 for all OAR. The mean femur doses with SIB-IMRT and SIB-IMRT-esc were 47% and 49% lower compared with 3D-CRT. SIB-IMRT-esc reduced the doses to the OAR compared with seq-3D-CRT but increased the D{sub max.} for the small bowel, rectum, and bladder. IMRT reduces the dose to the OAR compared with 3D-CRT in patients with vulvar cancer receiving irradiation to a volume covering the vulvar region and nodal areas without compromising the dosimetric coverage of the target volume. IMRT for vulvar cancer is feasible and an attractive option for dose escalation studies.

61 RADIATION PROTECTION AND DOSIMETRY↗