Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Limitations of the American Society of Therapeutic Radiology and Oncology Consensus Panel Guidelines on the Use of Accelerated Partial Breast Irradiation

Purpose: We applied the American Society of Therapeutic Radiology and Oncology (ASTRO) Consensus Panel (CP) guidelines for the use of accelerated partial breast irradiation (APBI) to patients treated with this technique to determine the ability of the guidelines to differentiate patients with significantly different clinical outcomes. Methods and Materials: A total of 199 patients treated with APBI and 199 with whole-breast irradiation (WBI) (matched for tumor size, nodal status, age, margins, receptor status, and tamoxifen use) were stratified into the three ASTRO CP levels of suitability ('suitable,' 'cautionary,' and 'unsuitable') to assess rates of ipsilateral breast tumor recurrence (IBTR), regional nodal failure, distant metastases, disease-free survival, cause-specific survival, and overall survival based on CP category. Median follow-up was 11.1 years. Results: Analysis of the APBI and WBI patient groups, either separately or together (n = 398), did not demonstrate statistically significant differences in 10-year actuarial rates of IBTR when stratified by the three ASTRO groups. Regional nodal failure and distant metastasis were generally progressively worse when comparing the suitable to cautionary to unsuitable CP groups. However, when analyzing multiple clinical, pathologic, or treatment-related variables, only patient age was associated with IBTR using WBI (p = 0.002). Conclusions: The ASTRO CP suitable group predicted for a low risk of IBTR; however, the cautionary and unsuitable groups had an equally low risk of IBTR, supporting the need for continued refinement of patient selection criteria as additional outcome data become available and for the continued accrual of patients to Phase III trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Remote Learning as Effective as In-Person Learning for Contouring Education? A Prospective Comparison of Face-to-Face versus Online Delivery of the Anatomy and Radiology Contouring Bootcamp

The Anatomy and Radiology Contouring (ARC) Bootcamp was a face-to-face (F2F) intervention providing integrated education for radiation oncology (RO) residents and medical physicists. To increase access, we launched an online offering in 2019. We evaluated the effect of the online course on participants' knowledge acquisition, contouring skills, and self-confidence by comparing it with the F2F course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Information Loss Via Visual Assessment of Radiologic Images Using Modified Version of the Low-Contrast Detailed Phantom at Direct DR System

Quality in radiology images can be assessed by determining the levels of information retained or lost in an image. Information loss in images has been recently assessed via a method based on information theory and the employment of a contrast-detail (CD) phantom. In this study, the traditional CD phantom (air-Perspex) and a modified CD phantom were used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atmospheric Dispersion Coefficients and Radiological and Toxicological Exposure Methodology for Use in Tank Farms

This report presents the atmospheric dispersion coefficients used in Tank Farms safety analysis. The basis equations for calculating radiological and toxicological exposures are also included. In this revision, the time averaging for toxicological consequence evaluations is clarified based on a review of DOE complex guidance and a review of tank farm chemicals.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chronic Pelvic Pain due to Pelvic Congestion Syndrome: The Role of Diagnostic and Interventional Radiology

Chronic pelvic pain (CPP) is a common cause of gynecologic referral. Pelvic congestion syndrome, which is said to occurs due to ovarian vein incompetence, is a recognized cause of CPP. The aim of this paper is to briefly describe the clinical manifestations, and to review the role of diagnostic and interventional radiology in the management of this probably under-diagnosed condition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography-Guided Percutaneous Radiologic Gastrostomy

The purpose of this study was to investigate the feasibility of a flat-detector C-arm-guided radiographic technique (cone-beam computed tomography [CBCT]) for percutaneous radiologic gastrostomy (PRG) insertion. Eighteen patients (13 men and 5 women; mean age 62 years) in whom percutaneous endoscopic gastrostomy (PEG) had failed underwent CBCT-guided PRG insertion. PEG failure or unsuitability was caused by upper gastrointestinal tract obstruction in all cases. Indications for gastrostomy were esophageal and head and neck malignancies, respectively. Before the PRG procedure, initial C-arm CBCT scans were acquired. Three- and 2-dimensional soft-tissue reconstructions of the epigastrium region were generated on a dedicated workstation. Subsequently, gastropexy was performed with T-fasteners after CBCT-guided puncture of the stomach bubble, followed by insertion of an 14F balloon-retained catheter through a peel-away introducer. Puncture of the stomach bubble and PRG insertion was technically successful in all patients without alteration of the epigastric region. There was no malpositioning of the tube or other major periprocedural complications. In 2 patients, minor complications occurred during the first 30 days of follow-up (PRG malfunction: n = 1; slight infection: n = 1). Late complications, which were mainly tube disturbances, were observed in 2 patients. The mean follow-up time was 212 days. CBCT-guided PRG is a safe, well-tolerated, and successful method of gastrostomy insertion in patients in whom endoscopic gastrostomy is not feasible. CBCT provides detailed imaging of the soft tissue and surrounding structures of the epigastric region in one diagnostic tour and thus significantly improves the planning of PRG procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiovascular and Interventional Radiological Society of Europe Commentary on the Treatment of Chronic Cerebrospinal Venous Insufficiency

Chronic cerebrospinal venous insufficiency (CCSVI) is a putative new theory that has been suggested by some to have a direct causative relation with the symptomatology associated with multiple sclerosis (MS). The core foundation of this theory is that there is abnormal venous drainage from the brain due to outflow obstruction in the draining jugular vein and/or azygos veins. This abnormal venous drainage, which is characterised by special ultrasound criteria, called the 'venous hemodynamic insufficiency severity score' (VHISS), is said to cause intracerebral flow disturbance or outflow problems that lead to periventricular deposits. In the CCSVI theory, these deposits have a great similarity to the iron deposits seen around the veins in the legs in patients with chronic deep vein thrombosis. Zamboni, who first described this new theory, has promoted balloon dilatation to treat the outflow problems, thereby curing CCSVI and by the same token alleviating MS complaints. However, this theory does not fit into the existing bulk of scientific data concerning the pathophysiology of MS. In contrast, there is increasing worldwide acceptance of CCSVI and the associated balloon dilatation treatment, even though there is no supporting scientific evidence. Furthermore, most of the information we have comes from one source only. The treatment is called 'liberation treatment,' and the results of the treatment can be watched on YouTube. There are well-documented testimonies by MS patients who have gained improvement in their personal quality of life (QOL) after treatment. However, there are no data available from patients who underwent unsuccessful treatments with which to obtain a more balanced view. The current forum for the reporting of success in treating CCSVI and thus MS seems to be the Internet. At the CIRCE office and the MS Centre in Amsterdam, we receive approximately 10 to 20 inquiries a month about this treatment. In addition, many interventional radiologists, who are directly approached by MS patients, contact the Cardiovascular and Interventional Radiological Society of Europe (CIRSE) for advice. Worldwide, several centres are actively promoting and performing balloon dilatation, with or without stenting, for CCSVI. Thus far, no trial data are available, and there is currently no randomized controlled trial (RCT) in progress Therefore, the basis for this new treatment rests on anecdotal evidence and successful testimonies by patients on the Internet. CIRSE believes that this is not a sound basis on which to offer a new treatment, which could have possible procedure-related complications, to an often desperate patient population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of Interventional Radiology in the Diagnosis and Management of Male Impotence

Erectile dysfunction (ED) is defined as the persistent inability to reach or maintain penile rigidity enough for sexual satisfaction. Nearly 30% of the men between ages 40 and 70 years are affected by ED. A variety of pathologies, including neurological, psychological, or endocrine disorders and drug side effects, may incite ED. A commonly identified cause of ED is vascular disease. Initial diagnostic workup includes a detailed physical examination and laboratory tests. Whilst duplex ultrasound is considered the first-line diagnostic modality, intra-arterial digital subtraction angiography is still considered the 'gold standard' for the diagnosis of arteriogenic impotence. Percutaneous endovascular treatment may be offered in patients with vasculogenic ED that has failed to respond to oral medical therapy as an alternative to penile prosthesis or open surgical repair. In arteriogenic ED balloon angioplasty of the aorto-iliac axis, and in veno-occlusive ED, percutaneous venous ablation using various embolization materials has been reported to be safe and to improve sexual performance. Recently, the ZEN study investigated the safety and feasibility of drug-eluting stents for the treatment of arteriogenic ED attributed to internal pudendal artery stenosis with promising preliminary results. This manuscript highlights the role of interventional radiology in the diagnosis and minimally invasive treatment of male impotence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Periprocedural Prophylactic Antithrombotic Strategies in Interventional Radiology: Current Practice in the Netherlands and Comparison with the United Kingdom

Purpose: The use of prophylactic antithrombotic drugs to prevent arterial thrombosis during the periprocedural period during (percutaneous) peripheral arterial interventions (PAIs) is still a matter of dispute, and clear evidence-based guidelines are lacking. To create those guidelines, a study group was formed in the Netherlands in cooperation with the Dutch Society of Vascular Surgery and the Society of Interventional Radiology. The study group is called 'Consensus on Arterial PeriProcedural Anticoagulation (CAPPA).' Materials and Methods: The CAPPA study group devised and distributed a comprehensive questionnaire amongst Dutch interventional radiologists (IRs). Results: One hundred forty-two IRs responded (68 %) to the questionnaire. Almost no IR stopped acetyl salicylic acid before interventions, and 40 % stopped clopidogrel before PAI but not before carotid artery stenting (CAS). A flushing solution on the sideport of the sheath was used routinely by 30 % of IRs in PAI and by 50 % of IRs during CAS. A minority of IRs used a heparinised flushing solution (28 %). Unfractionated heparin was used by 95 % of IRs as bolus; 5000 IU was the most used dosage. Timing of administration varied widely. A majority of IRs (75 %) repeated heparin administration after 1 h. Conclusion: A substantial variety exists amongst IRs in the Netherlands regarding the use of prophylactic periprocedural antithrombotic drugs to prevent arterial thrombosis during PAI. When compared with varying results regarding the use of heparin in the United Kingdom, the variety in the Netherlands showed a different pattern. The proven variety in these countries, and also between these countries, emphasises the need for authoritative studies to develop evidence-based practical guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Radiological Treatment of Perihepatic Vascular Stenosis or Occlusion in Pediatric Patients After Liver Transplantation

Purpose: Evaluation of the efficacy and safety of percutaneous treatment of vascular stenoses and occlusions in pediatric liver transplant recipients. Methods: Fifteen children (mean age 8.3 years) underwent interventional procedures for 18 vascular complications after liver transplantation. Patients had stenoses or occlusions of portal veins (n = 8), hepatic veins (n = 3), inferior vena cava (IVC; n = 2) or hepatic arteries (n = 5). Technical and clinical success rates were evaluated. Results: Stent angioplasty was performed in seven cases (portal vein, hepatic artery and IVC), and sole balloon angioplasty was performed in eight cases. One child underwent thrombolysis (hepatic artery). Clinical and technical success was achieved in 14 of 18 cases of vascular stenoses or occlusions (mean follow-up 710 days). Conclusion: Pediatric interventional radiology allows effective and safe treatment of vascular stenoses after pediatric liver transplantation (PLT). Individualized treatment with special concepts for each pediatric patient is necessary. The variety, the characteristics, and the individuality of interventional management of all kinds of possible vascular stenoses or occlusions after PLT are shown.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identifying the Learning Curve for Uterine Artery Embolisation in an Interventional Radiological Training Unit

AimA clear understanding of operator experience is important in improving technical success whilst minimising patient risk undergoing endovascular procedures, and there is the need to ensure that trainees have the appropriate skills as primary operators. The aim of the study is to retrospectively analyse uterine artery embolisation (UAE) procedures performed by interventional radiology (IR) trainees at an IR training unit analysing fluoroscopy times and radiation dose as surrogate markers of technical skill.MethodsTen IR fellows were primary operator in 200 UAE procedures over a 5-year period. We compared fluoroscopy times, radiation dose and complications, after having them categorised according to three groups: Group 1, initial five, Group 2, >5 procedures and Group 3, penultimate five UAE procedures. We documented factors that may affect screening time (number of vials employed and use of microcatheters).ResultsMean fluoroscopy time was 18.4 (±8.1), 17.3 (±9.0), 16.3 (±8.4) min in Groups 1, 2 and 3, respectively. There was no statistically significant difference between these groups (p > 0.05) with respect to fluoroscopy time or radiation dose. Analysis after correction for confounding factors showed no statistical significance (p > 0.05). All procedures were technically successful, and total complication rate was 4 %.ConclusionUAE was chosen as a highly standardised procedure followed by IR practitioners. Although there is a non-significant trend for shorter screening times with experience, technical success and safety were not compromised with appropriate Consultant supervision, which illustrates a safe construct for IR training. This is important and reassuring information for patients undergoing a procedure in a training unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Cryoablation of the Spine in a Swine Model: Clinical, Radiological, and Pathological Findings with Light and Electron Microscopy

PurposeThis study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body.MethodsThe institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO{sub 2}) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia.ResultsCBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO{sub 2} epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed.ConclusionsCBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous BioOrganic Sealing of Duodenal Fistulas: Case Report and Review of Biological Sealants with Potential Use in Interventional Radiology

Biological sealants are being increasingly used in a variety of surgical specialties for their hemostatic and sealing capabilities. However, their use in interventional radiology has not been widely reported. The authors describe a case of duodenal perforation occurring after 15 years of gastric bypass surgery, in whom surgical diversion was unsuccessfully attempted and the leakage was successfully controlled using percutaneous administration of a combination of biological and organic sealants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact on Patient Safety and Satisfaction of Implementation of an Outpatient Clinic in Interventional Radiology (IPSIPOLI-Study): A Quasi-Experimental Prospective Study

PurposeInterventional radiology (IR) procedures are associated with high rates of preparation and planning errors. In many centers, pre-procedural consultation and screening of patients is performed by referring physicians. Interventional radiologists have better knowledge about procedure details and risks, but often only get acquainted with the patient in the procedure room. We hypothesized that patient safety (PS) and patient satisfaction (PSAT) in elective IR procedures would improve by implementation of a pre-procedural visit to an outpatient IR clinic.Material and MethodsIRB approval was obtained and informed consent was waived. PS and PSAT were measured in patients undergoing elective IR procedures before (control group; n = 110) and after (experimental group; n = 110) implementation of an outpatient IR clinic. PS was measured as the number of process deviations. PSAT was assessed using a questionnaire measuring Likert scores of three dimensions: interpersonal care aspects, information/communication, and patient participation. Differences in PS and PSAT between the two groups were compared using an independent t test.ResultsThe average number of process deviations per patient was 0.39 in the control group compared to 0.06 in the experimental group (p < 0.001). In 9.1 % patients in the control group, no legal informed consent was obtained compared to 0 % in the experimental group. The mean overall Likert score was significantly higher in the experimental group compared to the control group: 2.68 (SD 0.314) versus 2.48 (SD 0.381) (p < 0.001).ConclusionPS and PSAT improve significantly if patients receive consultation and screening in an IR outpatient clinic prior to elective IR procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Realtime Monitoring on Dose Exposure to Staff Within an Interventional Radiology Setting

PurposeThe purpose of this study is to evaluate a new device providing real-time monitoring on radiation exposure during fluoroscopy procedures intending to reduce radiation in an interventional radiology setting.Materials and MethodsIn one interventional suite, a new system providing a real-time radiation dose display and five individual wireless dosimeters were installed. The five dosimeters were worn by the attending, fellow, nurse, technician, and anesthesiologist for every procedure taking place in that suite. During the first 6-week interval the dose display was off (closed phase) and activated thereafter, for a 6-week learning phase (learning phase) and a 10-week open phase (open phase). During these phases, the staff dose and the individual dose for each procedure were recorded from the wireless dosimeter and correlated with the fluoroscopy time. Further subanalysis for dose exposure included diagnostic versus interventional as well as short (<10 min) versus long (>10 min) procedures.ResultsA total of 252 procedures were performed (n = 88 closed phase, n = 50 learning phase, n = 114 open phase). The overall mean staff dose per fluoroscopic minute was 42.79 versus 19.81 µSv/min (p < 0.05) comparing the closed and open phase. Thereby, anesthesiologists were the only individuals attaining a significant dose reduction during open phase 16.9 versus 8.86 µSv/min (p < 0.05). Furthermore, a significant reduction of total staff dose was observed for short 51 % and interventional procedures 45 % (p < 0.05, for both).ConclusionA real-time qualitative display of radiation exposure may reduce team radiation dose. The process may take a few weeks during the learning phase but appears sustained, thereafter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vascular Closure Devices in Interventional Radiology Practice

Manual compression (MC) is a well-established technique for haemostasis following percutaneous arterial intervention. However, MC is labour and time intensive with potential limitations, particularly for patients who are coagulopathic, unable to comply with bed rest or obese and when large sheaths or anti-coagulants are used. There are a variety of vascular closure devices (VCDs) available to overcome these limitations. This review gives an overview of current VCDs, their mechanism of action, individual strengths and weaknesses, evidence base and utility in interventional radiology (IR) practice. The majority of the published evidence on VCDs is derived from patients undergoing cardiac interventions, which should be borne in mind when considering the applicability and transfer of this data for general IR practice. Overall, the evidence suggests that most VCDs are effective in achieving haemostasis with a similar rate of complications to MC although the complication profile associated with VCDs is distinct to that of MC. There is insufficient evidence to comparatively analyse the different types of VCDs currently available or reliably judge their cost-effectiveness. The interventional radiologist should have a thorough understanding of the available techniques for haemostasis and be able to identify and utilise the most appropriate strategy and closure technique for the individual patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Evaluation and Preparation in Vascular and Interventional Radiology: What Every Interventional Radiologist Should Know (Part 1: Patient Assessment and Laboratory Tests)

Performing an interventional procedure imposes a commitment on interventional radiologists to conduct the initial patient assessment, determine the best course of therapy, and provide long-term care after the procedure is completed. After patient referral, contact with the referring physician and multidisciplinary team approach is vital. In addition, clinical history, physical examination, as well as full understanding of the pre-procedural laboratory results and imaging findings can guide the interventional radiologist to implement the most appropriate management plan, avoid unnecessary procedures, and prevent complications to achieve a successful outcome. We provide a comprehensive, methodical review of pre-procedural care and management in patients undergoing vascular and interventional radiology procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗