Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A GNSS Receiver for Small-Sats Enabling Precision POD, Radio Occultations and Reflections

A low cost, low power, and low mass GNSS receiver (called Cion) has been developed and is currently flying on the CICERO cubesats. The receiver was designed in less than a year by JPL for Tyvak and GeoOptics for use in the GeoOptics CICERO constellation and leverages 25 years of JPL GNSS reciever design experience. Cion uses a commercial off-the-shelf (COTS) computer along with existing space qualified RF down-converters, software, and firmware to produce atmospheric Radio Occultation (RO) data. By combining a FPGA with dual core ARM processor and an embedded system controller, the Xilinx Zynq processor is an enabling technology that provides a customizable digital signal processing platform integrated into the computer (System on a chip) and enables off-the-shelf hardware to become the main engine behind this software defined radio. Using Linux for the on-board computer allows for fast development times and liberal use of existing open source software libraries. The parts of the receiver that require realtime implementation are performed in the Field Programmable Gate Array (FPGA), which can also be reprogrammed in flight. While the Zynq is not rad hard, the silicon on insulator (SOI) technology is rad tolerant ‘by accident’, allowing for its use in many space-based applications. Early results show that the Cion is working as designed, has demonstrated the first known GLONASS occultations, and obtains high quality atmospheric profiles with excellent lower troposphere penetration (near Earth’s surface).

Young, Larry↗

Shielding Considerations for CubeSat Structures During Solar Maximum

The purpose of this lessons learned is to communicate the utility of shielding in small spacecraft planning for the support of mission assurance and reliability. Numerous SmallSats have been flying in polar low earth orbit for scientific, communications, technology demonstrations, and imaging with academic, commercial, and government interests. Shielding has been part of mission assurance and reliability from the advent of long duration spacecraft missions. The Shields-1 CubeSat has been operating in polar low earth orbit since 16 December 2018 with atomic number (Z)-grade radiation shielding and demonstrates shielding effectiveness. Shields-1 has collected a representative example of solar minimum data in 2019 with 8 Teledyne dosimeters over varying shielding effectiveness. It serves as current experimental data and has been compared with NOVICE Shielding estimates using the AP8 –AE8 trapped radiation model with the Shields-1 CAD and generic CubeSat 3 unit (U) models. Using NOVICE model radiation analysis coding, the shielding effectiveness's, based on a generic CubeSat 3U structure with 4 electronic boards, were estimated for aluminum wall thicknesses ranging from 0.204 cmto4.44 cm (0.550 g/cm2–12.0 g/cm2) thick aluminum. For modeled polar orbiting spacecraft, solar maximum total ionizing dose (TID)increases by nearly a magnitude for thin-walled aluminum 0.550g/cm2-0.686 g/cm2(0.204 cm –0.254 cm) typical CubeSat structures. The shielding effectiveness by NOVICE Sigma estimates, which is a shielding sphere approximation around a detector, showed a linear relationship with wall thickness, which increased over the wall thickness by a ratio of 1.43 determined by linear regression analysis. Using NOVICE Adjoint Monte-Carlo Modeling of solar minimum and solar maximum with the inclusion of a worst-case solar particle event over a one year mission without geomagnetic shielding, the TID for minimum and maximum conditions for a generic 3U with a wall thickness of 0.254 cm is 158 RAD and 1540 RAD, respectively. The modeled total solar maximum TID is over estimated, because at low orbital latitudes a spacecraft will have shielding from Earth's magnetic field. However, TID will still be significant at high latitudes over the poles, where a spacecraft is exposed in a solar particle event. In contrast, to a thin walled generic 3U CubeSat, Shields-1 electronics enclosure has a shielding effectiveness of 21.3 g/cm2from NOVICE Sigma modeling and is expected to show reduced total ionizing dose increases during the present active Solar Cycle 25 period. Because solar particle events during solar maximum increase TID on electronic parts with thin-walled shielding in short periods of time, it is a mission assurance and reliability consideration on the spacecraft’s mission value versus adding shielding for risk reduction of premature spacecraft or instrument payload loss. Since the volumes of many instruments and system electronics have reduced with small spacecraft, shielding material costs and weight penalties have diminished. A small spacecraft project budget and schedule may limit traditional radiation-hardened part use and radiation testing requirements, where shielding can contribute to mission assurance and reliability with reduced costs.

Shields-1↗

Shielding Considerations for CubeSat Structures During Solar Maximum

The purpose of this lessons learned paper is to communicate the utility of shielding in small spacecraft planning for the support of mission assurance and reliability. Numerous SmallSats have been flying in polar low Earth orbit for science, communications, technology demonstrations, and imaging with academic, commercial, and government interests. Shielding has been part of mission assurance and reliability from the advent of long duration spacecraft missions. The Shields-1 CubeSat has been operating in polar low Earth orbit since 16 December 2018 with atomic number (Z)-grade radiation shielding and demonstrates shielding effectiveness. Shields-1 has collected a representative example of solar minimum data in 2019 with eight Teledyne µDosimeters over varying shielding effectivenesses. It serves as current experimental data and has been compared with NOVICE Shielding estimates using the AP8 – AE8 trapped radiation model with the Shields-1 CAD and generic CubeSat three unit (3U) models. Using NOVICE model radiation analysis coding, the shielding effectivenesses, based on a generic CubeSat 3U structure with four electronic boards, were estimated for aluminum wall thicknesses ranging from 0.204 cm to 4.44 cm (0.550 g/cm 2 to 12.0 g/cm 2 ). For modeled polar orbiting spacecraft, solar maximum total ionizing dose (TID) increases by nearly a magnitude for thin-walled aluminum 0.550-g/cm 2 - 0.686-g/cm 2 (0.204-cm – 0.254-cm) typical CubeSat structures. The shielding effectiveness estimated by NOVICE Sigma, which is a shielding sphere approximation around a detector, showed a linear relationship with wall thickness, which increased over the wall thickness by a ratio of 1.43 determined by linear regression analysis. Using NOVICE Adjoint Monte-Carlo Modeling of solar minimum and solar maximum with the inclusion of a worst-case solar particle event over a one-year mission without geomagnetic shielding, the TID for minimum and maximum conditions for a generic 3U with a wall thickness of 0.254 cm is 158 RAD and 1540 RAD, respectively. The modeled total solar maximum TID is over estimated, because at low orbital latitudes a spacecraft will have shielding from the Earth’s magnetic field. However, TID will still be significant at high latitudes over the poles, where a spacecraft is exposed in a solar particle event. In contrast to a thin-walled generic 3U CubeSat, the Shields-1 electronics enclosure has a shielding effectiveness of 21.3 g/cm 2 from NOVICE Sigma modeling and is expected to show reduced total ionizing dose increases during the present active Solar Cycle 25 period. Because solar particle events during solar maximum increase TID on electronic parts with thin-walled shielding in short periods of time, it is a mission assurance and reliability consideration on the mission value of the spacecraft versus adding shielding for risk reduction of premature spacecraft or instrument payload loss. Since the volumes of many instruments and system electronics have reduced with small spacecraft, shielding material costs and weight penalties have diminished. A small spacecraft project budget and schedule may limit traditional radiation-hardened part use and radiation testing requirements, where shielding can contribute to mission assurance and reliability with reduced costs.

Shields-1↗

Shields-1 Energetic Proton Dose Comparison from Solar Minimum and Active Periods

Shields-1 has been operating in polar low earth orbit since December 2018 as part of the CubeSat Launch Initiative (CSLI) Educational Launch of Nanosatellites (ELaNa)XIX Mission. Shields-1 has 8 Teledyne µdosimeters behind shielding. These shielded µdosimeters have high minimum proton energy thresholds. The Shields-1 electronics enclosure µdosimeter has a minimum proton threshold energy of 151 MeV. The annualized total ionizing dose (TID) in the electronics enclosure was 75.6 +/- 3.2 RAD from July-August 2019, which was a solar minimum period. In contrast, the annualized TID was 61.0 +/- 2.5 RAD in July 2023, a solar active month. The TID change can be attributed to both the reduction in radiation at the South Atlantic Anomaly (SAA) and the decrease in galactic cosmic radiation during increasing solar activity. The measured GCR dose over the poles was reduced during the July 2023 solar active period in comparison with the July 2019 solar minimum period, using the most sensitive µdosimeter channel for the measurement. Shields-1 has demonstrated the capability of measuring the changes in high energy protons in polar low earth orbit during changes in solar activity, which contributes to the understanding of Earth in the heliosphere.

Shields-1 Dosimetry Space Sciences↗

Permanent Magnet Skew Quadrupoles for the Low Emittance LER Lattice of PEP-II

The vertical emittance of the low energy ring (LER) in the PEP-II B-Factory was reduced by using skew quadrupoles consisting of permanent magnet material. The advantages over electric quadrupoles or rotating existing normal quadrupoles are discussed. To assure a high field quality, a Biot-Savart calculation was used to cancel the natural 12-pole component by using different size poles over a few layers. A magnetic measurement confirmed the high quality of the magnets. After installation and adjusting the original electric 12 skew and 16 normal quadrupoles the emittance contribution from the region close to the interaction point, which was the biggest part in the original design, was considerably reduced. To strengthen the vertical behavior of the LER beam, a low emittance lattice was developed. It lowered the original vertical design emittance from 0.54 nm-rad to 0.034 nm-rad. In order to achieve this, additional skew quadrupoles were required to bring the coupling correction out of the arcs and closer to the detector solenoid in the straight (Fig. 1). It is important, together with low vertical dispersion, that the low vertical emittance is not coupled into the horizontal, which is what we get if the coupling correction continues into the arcs. Further details of the lattice work is described in another paper; here we concentrate on the development of the permanent skew (PSK) quadrupole solution. Besides the permanent magnets there are two other possibilities, using electric magnets or rotating normal quadrupoles. Electric magnets would have required much more additional equipment like magnets stands, power supply, and new vacuum chamber sections. Rotating existing quadrupoles was also not feasible since they are mostly mounted together with a bending magnet on the same support girder.

43 PARTICLE ACCELERATORS↗

Comparison of Raman Scattering Measurements and Modeling in NIF Ignition Experiments

Recent NIF indirect-drive experiments have shown significant Raman scattering from the inner beams. NIF data has motivated improvements to rad-hydro modeling, leading to the 'high flux model' [M. D. Rosen et al., HEDP 7, 180 (2011)]. Cross-beam energy transfer [P. A. Michel et al., Phys. Plasmas 17, 056305 (2010] in the laser entrance hole is an important tool for achieving round implosions, and is uniformly distributed across the laser spot in rad-hydro simulations (but not necessarily in experiments). We find the Raman linear gain spectra computed with these plasma conditions agree well in time-dependent peak wavelength with the measured data, especially when overlapping laser-beam intensities are used. More detailed, spatially non-uniform modeling of the cross-beam transfer has been performed. The resulting gains better follow the time history of the measured backscatter. We shall present the impact of spatially non-uniform energy transfer on SRS gain. This metric is valid when amplification is in a linear regime, and so we shall also present an assessment of whether electron trapping in Langmuir waves can play a role in these shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final Muon Emittance Exchange in Vacuum for a Collider

We outline a plan for final muon ionization cooling with quadrupole doublets focusing onto short absorbers followed by emittance exchange in vacuum to achieve the small transverse beam sizes needed by a muon collider. A flat muon beam with a series of quadrupole doublet half cells appears to provide the strong focusing required for final cooling. Each quadrupole doublet has a low β region occupied by a dense, low Z absorber. After final cooling, normalized xyz emittances of (0.071, 0.141, 2.4) mm-rad are exchanged into (0.025, 0.025, 70) mm-rad. Thin electrostatic septa efficiently slice the bunch into 17 parts. The 17 bunches are interleaved into a 3.7 meter long train with RF deflector cavities. Snap bunch coalescence combines the muon bunch train longitudinally in a 21 GeV ring in 55 μs, one quarter of a synchrotron oscillation period. A linear long wavelength RF bucket gives each bunch a different energy causing the bunches to drift until they merge into one bunch and can be captured in a short wavelength RF bucket with a 13% muon decay loss and a packing fraction as high as 87%.

43 PARTICLE ACCELERATORS↗

Measuring x-ray spectra of flash radiographic sources [PowerPoint]

The x-ray spectra of flash radiographic sources are difficult to measure. The sources measured were Radiographic Integrated Test Stand-6 (370 rad at 1 m; 50 ns pulse) and Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) (550 rad at 1 m; 50 ns pulse). Features of the Compton spectrometer are described, and spectra are shown. Additional slides present data on instrumental calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of the Westinghouse Small Modular Reactor building layout

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor (iPWR), in which all of the components typically associated with the nuclear steam supply system (NSSS) of a nuclear power plant are incorporated within a single reactor pressure vessel. This paper is the third in a series of four papers, which describe the design and functionality of the Westinghouse SMR. It focuses in particular upon the plant building layout and modular design of the Westinghouse SMR. In the development of small modular reactors, the building layout is an area where the safety of the plant can be improved by applying new design approaches. This paper will present an overview of the Westinghouse SMR building layout and indicate how the design features improve the safety and robustness of the plant. The Westinghouse SMR is designed with no shared systems between individual reactor units. The main buildings inside the security fence are the nuclear island, the rad-waste building, the annex building, and the turbine building. All safety related equipment is located in the nuclear island, which is a seismic class 1 building. To further enhance the safety and robustness of the design, the reactor, containment, and most of the safety related equipment are located below grade on the nuclear island. This reduces the possibility of severe damage from external threats or natural disasters. Two safety related ultimate heat sink (UHS) water tanks that are used for decay heat removal are located above grade, but are redundant and physically separated as far as possible for improved safety. The reactor and containment vessel are located below grade in the center of the nuclear island. The rad-waste and other radioactive systems are located on the bottom floors to limit the radiation exposure to personnel. The Westinghouse SMR safety trains are completely separated into four unconnected quadrants of the building, with access between quadrants only allowed above grade. This is an improvement to conventional reactor design since it prevents failures of multiple trains during floods or fires and other external events. The main control room is located below grade, with a remote shutdown room in a different quadrant. All defense in depth systems are placed on the nuclear island, primarily above grade, while the safety systems are located on lower floors. The economics of the Westinghouse SMR challenges the established approach of large Light Water Reactors (LWR) that utilized the economies of scale to reach economic competitiveness. To serve the market expectation of smaller capital investment and cost competitive energy, a modular design approach is implemented within the Westinghouse SMR. The Westinghouse SMR building layout integrates the three basic design constraints of modularization; transportation, handling and module-joining technology. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Demonstration of SuperLig{sup R} 605 and SuperLig{sup R} 644 in a Regeneration Flow Sheet to Remove Radioactive Strontium and Cesium from Seawater - 16236

Remediation techniques are needed for efficient removal of radioactive strontium and cesium from seawater. Molecular Recognition Technology, using selective SuperLig{sup R} resins, demonstrates a clean chemistry approach to solving this problem. Molecular Recognition Technology offers high levels of separation of chemically pure metal contaminants, whose subsequent disposal is compatible with simple waste forms (grout and glass). SuperLig{sup R} resins can be regenerated with common reagents and used many times, limited by a dose of 1 E+9 Rad, which assures low volumes of secondary solid waste. The metal selectivity of the SuperLig{sup R} resin ensures that the solid waste is of low residual activity. These properties of sustainability are illustrated in a project that demonstrated the ability of two SuperLig{sup R} resins to selectively remove Cs and Sr from a seawater mimic representative of the contaminated seawater in Fukushima, Dai'ichi, Japan harbor. Removal of radioactive Sr-90 and Cs-134/Cs-137 from seawater using conventional ion exchange or a complexing agent is complicated by the presence of large excesses of competing ions such as Na, K, Ca, and Mg, which can be co-extracted. These competing ions, if co-extracted, reduce the capacity of a single pass resin with the consequent increase in volume of spent resin or decrease in capacity of a regenerable resin. The successful demonstration reported in this study has shown the ability of two proprietary resins, SuperLig{sup R} 605 and SuperLig{sup R} 644, to remove Sr and Cs, respectively, with high selectivity from simulated solutions containing these metal ions together with major constituents of seawater at their normal concentrations. This effort was part of a demonstration project to investigate methods for removal of Sr-90 and Cs-134/Cs-137 from 160,000 cubic meters of seawater impounded at Fukushima, Dai'ichi, Japan harbor. SuperLig{sup R} resins can be regenerated by elution with small volumes of simple acid solutions. SuperLig{sup R} resins have a high tolerance to radiation, with their performance not being degraded by doses of 1.0 E+9 Rad. Estimates, based on the results obtained, are that Cs and Sr levels in the volume of seawater in the Fukushima, Dai'ichi, Japan harbor could be reduced to desired discharge limits in 200 days with some 30 cubic meters of the two SuperLig{sup R} resins and that decontamination factors of 10 or more could be achieved. Results of the demonstration, together with advantages of the Molecular Recognition Technology process over conventional procedures for these separations are presented and discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2014 LANL Radionuclide Air Emissions Report

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2014, and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s RadNESHAP compliance program, which is part of the Environmental Protection Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Region 6.

54 ENVIRONMENTAL SCIENCES↗

Radiation-Triggered Surveillance for UF6 Monitoring

This paper recommends the use of radiation detectors, singly or in sets, to trigger surveillance cameras. Ideally, the cameras will monitor cylinders transiting the process area as well as the process area itself. The general process area will be surveyed to record how many cylinders have been attached and detached to the process between inspections. Rad-triggered cameras can dramatically reduce the quantity of recorded images, because the movement of personnel and equipment not involving UF6 cylinders will not generate a surveillance review file.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

2018 LANL Radionuclide Air Emissions Report

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2018 and the resulting off-site dose from these emissions. This documents fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61. Subpart H - Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Precision of Measured Radionuclide Ambient Air Concentrations

According to AIRNET – Quality Assurance Project Plan for the Radiological Air Sampling Network, SOP-5140, Revision 2 (to become EPC-CP-PIP-5140): “The regulation 40 CFR Part 61.93 requires that the system be able to readily detect a dose of 1.0 mrem above background. Following statistical principles and assuming 95% confidence for such a measurement, we require that 95% of all measurements must fall within two standard deviations of the mean. This represents the minimum acceptable precision for decision making.” An independent assessment of the Rad-NESHAP program completed in early 2019 found that no documentation existed proving that the Airnet data meets the precision defined above. Therefore, to address this particular finding, Airnet concentration data was pulled from the Environmental Information Management (EIM), a cloud-based database maintained by Locus Technologies, for analysis.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Significance Tests on Stack Sample Data

In October 2023, external assessors visiting LANL’s Rad-NESHAP team reviewed the annual source term documentation package for stack emissions. This document discusses how the team uses significance tests to determine whether or not a measurement represents an actual detection of emitted radioactive material. The significance tests used in the evaluation compare the measured sample result to the Minimum Detectable Activity (MDA) for the sample; to the uncertainty of that measurement; and to the mean blank sample for the same time period. The blank test uses the average blank plus 2-standard deviations (2σ) of the blank results as a comparison threshold for this final evaluation.

54 ENVIRONMENTAL SCIENCES↗

Patterns of genomic variation in Coho salmon following reintroduction to the interior Columbia River

Abstract Coho salmon were extirpated in the mid‐20th century from the interior reaches of the Columbia River but were reintroduced with relatively abundant source stocks from the lower Columbia River near the Pacific coast. Reintroduction of Coho salmon to the interior Columbia River (Wenatchee River) using lower river stocks placed selective pressures on the new colonizers due to substantial differences with their original habitat such as migration distance and navigation of six additional hydropower dams. We used restriction site‐associated DNA sequencing ( RAD ‐seq) to genotype 5,392 SNP s in reintroduced Coho salmon in the Wenatchee River over four generations to test for signals of temporal structure and adaptive variation. Temporal genetic structure among the three broodlines of reintroduced fish was evident among the initial return years (2000, 2001, and 2002) and their descendants, which indicated levels of reproductive isolation among broodlines. Signals of adaptive variation were detected from multiple outlier tests and identified candidate genes for further study. This study illustrated that genetic variation and structure of reintroduced populations are likely to reflect source stocks for multiple generations but may shift over time once established in nature.

Campbell, Nathan R.↗

Evaluation of radiographers’ mammography screen-reading accuracy in Australia

This study aimed to evaluate the accuracy of radiographers’ screen-reading mammograms. Currently, radiologist workforce shortages may be compromising the BreastScreen Australia screening program goal to detect early breast cancer. The solution to a similar problem in the United Kingdom has successfully encouraged radiographers to take on the role as one of two screen-readers. Prior to consideration of this strategy in Australia, educational and experiential differences between radiographers in the United Kingdom and Australia emphasise the need for an investigation of Australian radiographers’ screen-reading accuracy. Ten radiographers employed by the Westmead Breast Cancer Institute with a range of radiographic (median = 28 years), mammographic (median = 13 years) and BreastScreen (median = 8 years) experience were recruited to blindly and independently screen-read an image test set of 500 mammograms, without formal training. The radiographers indicated the presence of an abnormality using BI-RADS®. Accuracy was determined by comparison with the gold standard of known outcomes of pathology results, interval matching and client 6-year follow-up. Individual sensitivity and specificity levels ranged between 76.0% and 92.0%, and 74.8% and 96.2% respectively. Pooled screen-reader accuracy across the radiographers estimated sensitivity as 82.2% and specificity as 89.5%. Areas under the reading operating characteristic curve ranged between 0.842 and 0.923. This sample of radiographers in an Australian setting have adequate accuracy levels when screen-reading mammograms. It is expected that with formal screen-reading training, accuracy levels will improve, and with support, radiographers have the potential to be one of the two screen-readers in the BreastScreen Australia program, contributing to timeliness and improved program outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗