Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Initial evaluation of a multimodal diamond sensor for simultaneous temperature and radiation measurements

Several experimental disciplines require simultaneous neutron flux and temperature monitoring. This paper provides the groundwork on a diamond sensor concept that could be used in harsh environments where the limits of current technologies are exceeded. Here, we present initial results on the functionality of a multimodal diamond sensor, which can simultaneously sense the presence of alpha particles at a few counts per second at temperatures up to 494 K. Such a sensor may also have applications where both charged particles or neutron detection and temperature measurement are simultaneously desired.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement accuracy and spatial resolution of a distributed temperature sensor based on a two-pulse differential coherent reflectometer

We present a model and numerical simulation of a distributed temperature sensor based on a two-pulse differential coherent optical time-domain reflectometer (COTDR). The differential phase measured using a phase-sensitive Rayleigh reflectometer is shown to have a regular component, which is a linear function of temperature, and a random component, which is related to a random distribution of scattering centres in the fibre and restricts the accuracy of measurements of variations in temperature. Measurement accuracy can be improved by reducing the relative contribution of the random component via a decrease in pulse duration and/or an increase in the time delay between pulses. The spatial resolution of a differential two-pulse phase-sensitive reflectometer is shown to be determined by the time delay between pulses and to vary little with pulse duration. At a typical pulse duration (200 ns) and delay time (300 ns), the accuracy in measurements of variations in temperature in the 0.1-K range is 2 % and the spatial resolution is about 30 m. (fibre-optic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bolometric Superconducting Optical Nanoscopy (BOSON)

Superconducting transition-edge sensors are renowned for their extraordinary photon sensitivity and energy resolution, finding applications spanning quantum information, astronomy, and nanophotonics. Here, we report the development of bolometric superconducting optical nanoscopy (BOSON), a novel platform that integrates bolometric detection at the superconducting transition edges with near-field optical techniques. BOSON enables the mapping of photoinduced changes in superconductivity with unprecedented spatial resolution and photon sensitivity. By incorporating BOSON with low-dimensional materials, we achieved polariton imaging at nanowatt excitation levels—at least 4 orders of magnitude lower than the power typically required in prior near-field nanoscopy experiments. Our findings highlight the potential for BOSON to advance scanning-probe-based optical platforms to enable the detection of photons, polaritons, and Cooper pair dynamics at the nanoscale. This paves the way for quantum sensing applications using single-polariton detection and can offer deeper insights into quasiparticle dynamics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laterally stacked Schottky diodes for infrared sensor applications

Laterally stacked Schottky diodes for infrared sensor applications are fabricated utilizing porous silicon having pores. A Schottky metal contract is formed in the pores, such as by electroplating. The sensors may be integrated with silicon circuits on the same chip with a high quantum efficiency, which is ideal for IR focal plane array applications due to uniformity and reproducibility.

Lin, True-Lon↗

Quantum Anomalies in Condensed Matter

Quantum materials provide a fertile ground in which to test and realize unusual phenomena such as quantum anomalies predicted by quantum field theory. There are three important symmetries that are broken when classical field theory is moved into the quantum regime, the scale anomaly, the axial (chiral) anomaly, and the parity anomaly. Several potential device applications may be realized by the discovery of quantum anomalies in condensed matter, enabled by the new physics they embody, including ultra‐sensitive dark matter detectors, far infrared optical modulators, micro‐bolometric detectors, low‐dissipation ballistic transporters, terahertz‐based qubits, terahertz polarization state controls, passive magnetic field sensors, stable topological superconductors that host Majorana fermions, and qubits topologically protected against decoherence. In this perspective article, the definition of these quantum anomalies is laid out, how little is known in the context of condensed matter, and how quantum anomalies are predicted to manifest as anomalous electronic, thermal, and magnetic behavior in experiments on topological quantum materials, including Weyl and Dirac semimetals. Furthermore, the importance that mechanical strain and defects will play in modifying signatures of quantum anomalies is discussed.

36 MATERIALS SCIENCE↗

The fluorescence quantum yield parameter in Förster resonance energy transfer (FRET)—Meaning, misperception, and molecular design

The fluorescence quantum yield parameter in Förster resonance energy transfer (FRET) processes underpins vital phenomena ranging from light harvesting in photosynthesis to design of sensors for monitoring physiological processes. The criteria for choosing a donor for use in FRET processes include chemical features (solubility, bioconjugatability, synthetic accessibility, and stability) as well as photophysical properties pertaining to absorption (wavelength and molar absorption coefficient) and fluorescence (wavelength and fluorescence quantum yield). The value of the donor fluorescence quantum yield (Φf, or emphatically, Φf(D)) alone has sometimes been thought (erroneously) to place a ceiling on the possible quantum yield of energy transfer (Φtrans). A high value of the donor Φf, while attractive, is not at all essential; indeed, many valuable candidates for use as FRET donors have likely been excluded on the basis of this injudiciously applied filter. Such disregard is unwarranted. In this tutorial overview, the equations for FRET are reviewed along with pertinent core concepts in photophysics. An analogy using simple hydraulics provides a pedagogical tool for the non-aficionado to better understand photochemical kinetics. Ten examples are presented of donor–acceptor systems with donors that exhibit a range of Φf values (0.60, 0.59. 0.21, 0.17, 0.12, 0.118, 0.04, 0.018, 0.007, and 0.003; i.e., 60%–0.3%), yet for each corresponding donor–acceptor pair, the value of Φtrans is at least 0.70 and in some cases nearly 1.00 (i.e., 70%–100%). The systems encompass protein, synthetic inorganic, and synthetic organic architectures. The objectives of this illustrative review are to deepen understanding of FRET and to broaden molecular design considerations by enabling selection from among a far richer set of donors for use in FRET processes.

Lindsey, Jonathan S. (ORCID:0000000248722040)↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Edge‐Driven Fringe‐Field Effects, Reduced Screening, and Bandgap Widening in Graphene Nanoribbons Enable Single‑Molecule Sensitivity

Graphene nanoribbons (GNRs) offer promising platforms for single‐molecule sensing due to their quasi‐1D channels and discrete electronic states, providing superior sensitivity toward molecular perturbations. While prior studies emphasize smoother edges as essential for optimal performance, the potential benefits of controlled edge roughness remain largely unexplored. Additionally, most investigations focus on GNR arrays, leaving critical edge‐ and width‐dependent factors, including fringe fields, bandgap widening, interactions between adsorbing molecules and GNR atoms, density of states (DOS) suppression, and electrostatic screening lengths, and their collective impact on sensitivity, poorly understood. Here, in this work, we fabricated field‐effect transistors using individual GNRs (widths: 200–20 nm) and characterized their response to molecular adsorption with perfluorooctanoic acid as the model analyte. Narrower ribbons displayed significantly enhanced sensitivity, yielding a coverage‐normalized response of 116 ± 10 mV per molecule in 20 nm‐wide GNRs (from calibrated ensemble Dirac‐point shifts). Experimental and theoretical analyses reveal that this heightened sensitivity arises from stronger fringe fields, width‐dependent quantum confinement effects, reduced DOS, and increased edge roughness that facilitates molecular anchoring, enhanced orbital overlap, and improved charge transfer efficiency. Our findings challenge the conventional assumption that smoother edges inherently enhance sensor performance, demonstrating that controlled edge disorder substantially boosts molecular sensitivity in GNR sensors.

36 MATERIALS SCIENCE↗

Colors of entangled two-photon absorption

Multiphoton absorption of entangled photons offers ways for obtaining unique information about chemical and biological processes. Measurements with entangled photons may enable sensing biological signatures with high selectivity and at very low light levels to protect against photodamage. In this paper, we present a theoretical and experimental study of the excitation wavelength dependence of the entangled two-photon absorption (ETPA) process in a molecular system, which provides insights into how entanglement affects molecular spectra. We demonstrate that the ETPA excitation spectrum can be different from that of classical TPA as well as that for one-photon resonant absorption (OPA) with photons of doubled frequency. These results are modeled by assuming the ETPA cross-section is governed by a two-photon excited state radiative linewidth rather than by electron-phonon interactions, and this leads to excitation spectra that match the observed results. Further, we find that the two-photon-allowed states with highest TPA and ETPA intensities have high electronic entanglements, with ETPA especially favoring states with the longest radiative lifetimes. These results provide concepts for the development of quantum light–based spectroscopy and microscopy that will lead to much higher efficiency of ETPA sensors and low-intensity detection schemes.

Science & Technology - Other Topics↗

A microwave SQUID multiplexer optimized for bolometric applications

A microwave SQUID (superconducting quantum interference device) has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/ $\sqrt{Hz}$, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charge-coupled device (CCD) television camera for NASA's Galileo mission to Jupiter

The CCD detector under construction for use in the slow-scan television camera for the NASA Galileo Jupiter orbiter to be launched in 1985 is presented. The science objectives and the design constraints imposed by the earth telemetry link, platform residual motion, and the Jovian radiation environment are discussed. Camera optics are inherited from Voyager; filter wavelengths are chosen to enable discrimination of Galilean-satellite surface chemical composition. The CCO design, an 800 by 800-element 'virtual-phase' solid-state silicon image-sensor array with supporting electronics, is described with detailed discussion of the thermally generated dark current, quantum efficiency, signal-to-noise ratio, and resolution. Tests of the effect of ionizing radiation were performed and are analyzed statistically. An imaging mode using a 2-1/3-sec frame time and on-chip summation of the signal in 2 x 2 blocks of adjacent pixels is designed to limit the effects of the most extreme Jovian radiation. Smearing due to spacecraft/target relative velocity and platform instability will be corrected for via an algorithm maximizing spacial resolution at a given signal-to-noise level. The camera is expected to produce 40,000 images of Jupiter and its satellites during the 20-month mission.

Klaasen, K. P.↗

Absorber Materials for Transition-Edge Sensor X-ray Microcalorimeters

Arrays of superconducting transition-edge sensors (TES) can provide high spatial and energy resolution necessary for x-ray astronomy. High quantum efficiency and uniformity of response can be achieved with a suitable absorber material, in which absorber x-ray stopping power, heat capacity, and thermal conductivity are relevant parameters. Here we compare these parameters for bismuth and gold. We have fabricated electroplated gold, electroplated gold/electroplated bismuth, and evaporated gold/evaporated bismuth 8x8 absorber arrays and find that a correlation exists between the residual resistance ratio (RRR) and thin film microstructure. This finding indicates that we can tailor absorber material conductivity via microstructure alteration, so as to permit absorber thermalization on timescales suitable for high energy resolution x-ray microcalorimetry. We show that by incorporating absorbers possessing large grain size, including electroplated gold and electroplated gold/electroplated bismuth, into our current Mo/Au TES, devices with tunable heat capacity and energy resolution of 2.3 eV (gold) and 2.1 eV (gold/bismuth) FWHM at 6 keV have been fabricated.

Brown, Ari-David↗

A 640 X 512-Pixel Portable Long-Wavelength Infrared Camera

A portable long-wavelength infrared electronic camera having a cutoff wavelength of 9 microns has been built around an image sensor in the form of a 640X512-pixel array of AlxGa(1-x)As/GaAs quantum-well infrared photodetectors (QWIPs). This camera is an intermediate product of a continuing program to develop high-resolution, high-sensitivity infrared cameras.

Gunapala, Sarath↗

Secure Intra-Body Wireless Communications (SIWiC) System Project

SIWiC System is a project to investigate, design and implement future wireless networks of implantable sensors in the body. This futuristic project is designed to make use of the emerging and yet-to-emerge technologies, including ultra-wide band (UWB) for wireless communications, smart implantable sensors, ultra low power networking protocols, security and privacy for bandwidth and power deficient devices and quantum computing. Progress in each of these fronts is hindered by the needs of breakthrough. But, as we will see in this paper, these major challenges are being met or will be met in near future. SIWiC system is a network of in-situ wireless devices that are implanted to coordinate sensed data inside the body, such as symptoms monitoring collected internally, or biometric data collected of an outside object from within the intra-body network. One node has the capability of communicating outside the body to send data or alarm to a relevant authority, e.g., a remote physician.

Ahmad, Aftab↗

Chemical, Biological, Radiological, Nuclear, and Explosives (CBRNE) Sensing XXI

This volume contains 12 sessions, 28 papers and 26 presentations on the following topics: Photonic Integrated Circuits and Plasmonic Sensing; Advancs in CBE Signature Modeling and Sensor Algorithms I; Standoff Sensing of CBRNE Hazards I; Standoff Sensing of CBRNE Hazards II; Advances in CBE Signature Modeling and Sensor Algorithms II; Biological Hazard Sensing; Chemical Hazard Sensing; Joint Session with Conferences 11390 and 11416: Spectroscopy for CBRNE Detection and Warning; Radiological and Nuclear Sensing; Explosive Material Sensing; Poster Session.

47 OTHER INSTRUMENTATION↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Aerosol jet printed 3 omega sensors for thermal conductivity measurement

The 3 omega (3ω) method is a trusted technique for measuring thermal conductivity—a fundamental material property of critical importance in a broad range of applications. However, traditional 3ω sensor processing requires some form of physical vapor deposition, such as metal evaporation or sputtering. These 3ω sensor deposition techniques limit the materials and sample sizes applicable to the 3ω method. This work demonstrates an aerosol jet printing method to directly print silver 3ω sensors that yield accurate temperature-dependent measurement up to 300 °C on materials with thermal conductivity ranging from 1 to 150 W/m K. The interrelationship between printed sensor geometry, sensor thermal stability, and applicability to the 3ω method is examined. Thermal conductivity measurement with 3ω sensors conventionally sintered at 300 °C agrees to independent laser flash measurement within 4% from room temperature to 150 °C. An unconventional rapid high-temperature sintering method is shown to produce sensors that agree within 3% of the laser flash measurements from room temperature to 300 °C. The rapid sintering profiles also reduced the sensor–substrate thermal boundary resistance of the printed sensors by as much as 88%. The direct printing of 3ω sensors creates opportunities for measurement of thermal transport properties in applications previously inapplicable to the 3ω method.

47 OTHER INSTRUMENTATION↗

Spin squeezing in an ensemble of nitrogen–vacancy centres in diamond

Spin-squeezed states provide a seminal example of how the structure of quantum mechanical correlations can be controlled to produce metrologically useful entanglement. These squeezed states have been demonstrated in a wide variety of quantum systems ranging from atoms in optical cavities to trapped ion crystals. By contrast, despite their numerous advantages as practical sensors, spin ensembles in solid-state materials have yet to be controlled with sufficient precision to generate targeted entanglement such as spin squeezing. Here we report the experimental demonstration of spin squeezing in a solid-state spin system. Our experiments are performed on a strongly interacting ensemble of nitrogen–vacancy colour centres in diamond at room temperature, and squeezing (−0.50 ± 0.13 dB) below the noise of uncorrelated spins is generated by the native magnetic dipole–dipole interaction between nitrogen–vacancy centres. To generate and detect squeezing in a solid-state spin system, we overcome several challenges. First, we develop an approach, using interaction-enabled noise spectroscopy, to characterize the quantum projection noise in our system without directly resolving the spin probability distribution. Second, noting that the random positioning of spin defects severely limits the generation of spin squeezing, we implement a pair of strategies aimed at isolating the dynamics of a relatively ordered sub-ensemble of nitrogen–vacancy centres. Furthermore, our results open the door to entanglement-enhanced metrology using macroscopic ensembles of optically active spins in solids.

Atomic and molecular physics↗