Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quadrupole”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Test Results of the LQXFA/B02 and LQXFA/B03 Cryo-Assemblies for the High Luminosity LHC Upgrade

Here, the US High-Luminosity LHC Accelerator Upgrade Project (AUP) is responsible for delivering cryo-assemblies for the Q1/Q3 quadrupole optical components of the High Luminosity LHC upgrade at CERN. Total of 10 cryo-assemblies containing two Nb3Sn quadrupole magnets per cold mass will be delivered within this program. After the successful test of the first pre-series cryo-assembly in 2023, two more cryo-assemblies were tested at Fermilab's horizontal test facility. Production overview and the test results of the LQXFA/B02 and LQXFA/B03 cryo-assemblies are summarized in this paper. After the first test, to increase the capability of the horizontal test facility, various improvements have been made. These improvements are also described in this paper.

Chlachidze, Guram [Fermi National Accelerator Labo↗

Surrogate model for third-integer resonance extraction at the Fermilab Delivery Ring

We present an ongoing work in which a surrogate model is being developed to reproduce the response dynamics of the third-integer resonant extraction process in the Delivery Ring (DR) at Fermilab. This is in pursuit of smoothly extracting circulating beam to the Mu2e Experiment’s production target, whereby the goal is to extract a uniform slice of the circulating 1e12 protons in the DR over 25,000 turns (43 ms). The DR contains 3 harmonic sextupoles that excite a third-integer resonance and three fast, tune-ramping quadrupole magnets that drive the horizontal tune towards the 29/3 resonance. In our initial work, the surrogate model trains on a semi-analytical simulation provided in the same format as live data. Using Reinforcement Learning (and other potential ML methods), the trained surrogate acts as the “environment” in which a simple ML control agent could learn to dynamically adjust the quadrupole ramp at 430 break points within the 43 microsecond spill window. The controller will be hosted on a dedicated Arria 10 FPGA. In this work, we report the accuracy and fidelity of the surrogate model in comparison to the response dynamics of the physics simulator.

Narayanan, Aakaash [Fermilab]↗

Fundamental 235 Uranium Nuclear Resonance Spectroscopy (End of Year Report)

Uranium-235 is ubiquitous in the nuclear industry however, detailed characterization by magnetic resonance spectroscopy has remained largely elusive to-date. Conventional nuclear magnetic resonance techniques are ill-suited for characterizing 235 U due to the small gyromagnetic ratio and extremely large quadrupole moment of this spin$^{7}$ /2 isotope. Thus, we have designed and built a high-frequency nuclear quadrupole resonance spectrometer for measuring the quadrupole resonance of this important isotope. A successful nuclear quadrupole resonance measurement of 235 U would be a significant accomplishment and could yield valuable physical parameters such as chemical shifts, local electric field gradients, and through-bond and through-space internuclear couplings, all of which are directly related to local structure. These terms can be used to understand structural details of poorly characterized uranium materials and can improve computational models of uranium for which accurate reference data is lacking

07 ISOTOPE AND RADIATION SOURCES↗

Feasibility Study of NSLS-II Sextupole BBA Measurement

In storage ring light sources, beam-based alignment (BBA) which adjusts the BPM centers to the quadrupole magnet centers is a common practice to maintain the machine performance. For more reliable and convenient BBA process, in the design of the storage ring, BPMs are located as close as possible to the quadrupoles. The most common method is scanning the position of the beam at the BPM (equivalently at the adjacent quadrupole) and find the position where the quadrupole strength change does not give change in the closed orbit. In the simulation of the feasibility test, we choose parameters, tune, orbit and phase advance and measure their variations depending on the sextupole offsets. Also, together with the real configuration of family, we simulate the individual power supply case for the comparisons. In this note, the simulation processes and the results are presented.

43 PARTICLE ACCELERATORS↗

Determining gravitational radiation from Newtonian self-gravitating systems

Quadrupole gravitational radiation formulas are tested and compared in a calculation of rotating stellar core collapse. While the standard quadrupole formula (SQF) allows an economical calculation of the waveform in postlinear gravity, it has several shortcomings that become apparent in a finite difference (FD) calculation. These shortcomings are related to the large-moment arm of the quadrupole moment and the two (numerical) time derivatives that separate it from the waveform. These shortcomings lead to high-frequency noise in the SQF waveform. Several alternatives to the SQF are developed. Each is mathematically equivalent to the SQF and applicable to self-gravitating sources. For FD calculations, the new quadrupole formulas are all superior to the SQF and capable of producing waveforms free of the high-frequency noise characteristics of its use.

Finn, Lee Samuel↗

On the rms anisotropy at 7 deg and 10 deg observed in the COBE-DMR two year sky maps

The frequency-independent rms temperature fluctuations determined from the Cosmic Background Explorer-Differential Microwave Radiometer (COBE-DMR) two-year sky maps are used to infer the parameter Q(sub rms-PS), which characterizes the normalization of power-law models of primordial cosmological temperature anisotropy, for a forced fit to a scale-invariant Harrison-Zel'dovich (n = 1) spectral model. Using a joint analysis of the 7 deg and 10 deg 'cross'-rms derived from both the 53 and 90 GHz sky maps, we find Q(sub rms-PS) = 17.0(sub -2.1 sup +2.5) micro Kelvin when the low quadrupole is included, and Q(sub rms-PS) = 19.4(sub -2.1 sup +2.3) micro Kelvin excluding the quadrupole. These results are consistent with the n = 1 fits from more sensitive methods. The effect of the low quadrupole derived from the COBE-DMR data on the inferred Q(sub rms-PS) normalization is investigated. A bias to lower Q(sub rms-PS) is found when the quadrupole is included. The higher normalization for a forced n = 1 fit is then favored by the cross-rms technique.

Banday, A. J.↗

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

Toward a Micro Gas Chromatograph/Mass Spectrometer (GC/MS) System

Miniature mass filters (e.g., quadrupoles, ion traps) have been the subject of several miniaturization efforts. A project is currently in progress at JPL to develop a miniaturized Gas Chromatograph/Mass Spectrometer (GC/MS) system, incorporating and/or developing miniature system components including turbomolecular pumps, scroll type roughing pump, quadrupole mass filter, gas chromatograph, precision power supply and other electronic components. The preponderance of the system elements will be fabricated using microelectromechanical systems (MEMS) techniques. The quadrupole mass filter will be fabricated using an X-ray lithography technique producing high precision, 5x5 arrays of quadrupoles with pole lengths of about 3 mm and a total volume of 27 cubic mm. The miniature scroll pump will also be fabricated using X-ray lithography producing arrays of scroll stages about 3 mm in diameter. The target detection range for the mass spectrometer is 1 to 300 atomic mass units (AMU) with are solution of 0.5 AMU. This resolution will allow isotopic characterization for geochronology, atmospheric studies and other science efforts dependant on the understanding of isotope ratios of chemical species. This paper will discuss the design approach, the current state-of-the art regarding the system components and the progress toward development of key elements. The full system is anticipated to be small enough in mass, volume and power consumption to allow in situ chemical analysis on highly miniaturized science craft for geochronology, atmospheric characterization and detection of life experiments applicable to outer planet roadmap missions.

Wiberg, D. V.↗

Deformation of the $0^+_{1,2}$ states in 110 Cd from low-energy Coulomb excitation

Electromagnetic properties of 110 Cd were studied via low-energy Coulomb excitation with 32 S and 14 N beams. Magnitudes and relative signs of eight E2 matrix elements, including quadrupole moments of the $2^+_1$ and $2^+_2$ states, were determined using the least-squares code GOSIA. From those, quadrupole deformation parameters of the $0^+_{1,2,3}$ states were inferred, providing for the first time conclusive evidence for the non-axial character of the ground state in 110 Cd. The experimental results were compared with new calculations using the general quadrupole collective Bohr Hamiltonian model with SLy4 and UNEDF0 interactions. The non-axiality of the ground state is reproduced by the present calculations, independently of the interaction used.

Collective models↗

Design of an Emittance Compensation Superconducting Magnet Package for LCLS-II-HE's SRF Photo-Injector

An SRF photo-injector (low frequency, quarter-wave resonator plus emittance compensation magnet) is planned for LCLS-II-HE as it can provide a higher cathode gradient and better electron beam quality than other types of CW electron guns. The magnet package is located immediately downstream of the SRF cavity, and incorporates a solenoid doublet, bucking coils for reduction of the fringe field, normal/skew quadrupoles and horizontal/vertical dipoles. All the magnets are wound of NbTi wire and operate in liquid helium environment. The solenoid package is located inside the SRF gun cryomodule. Design considerations include space limitations, optimal emittance compensation, the magnetic field limits in the superconducting wire and quench protection. The solenoid coils must provide a peak excitation > 25 kgauss 2 ·cm, a fringe field < 20 gauss at the wall of the SRF cavity, an integrated dipole field < 90 gauss·cm and an integrated quadrupole field < 10 gauss. As a result, a genetic algorithm was used to optimize the solenoid design. Correction dipoles and quadrupoles were designed using coil dominated Walstrom style coils.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dipole Field Effects on Ion Ejections from a Paul Ion Trap

Attempts at improving the quality of mass spectra obtained from a Paul trap mass spectrometer prompted an investigation of the effects of additional fields to supplement the primary rf quadrupole trapping field. Reported here are the results of the first in a series of tests that focuses on the application of a single dipole field to augment the trapping and subsequent ejections of ions stored within a Paul trap. Measurements are presented for a fixed quadrupole frequency with varying dipole frequencies. The presence of the dipole field during the quadrupole trapping phase causes ion ejections of single m/z species at discrete dipole frequencies. During the mass analysis phase, the varying dipole frequency produces a complex set of resonant structures that impact ejection time (mass range), as well as mass spectral peak intensity and width

dipole↗

Accurate calculation of many-body energies in water clusters using a classical geometry-dependent induction model

We incorporate geometry-dependent distributed multipole and polarizability surfaces into an induction model that is used to describe the 3- and 4-body terms of the interaction between water molecules. The expansion is carried out up to hexadecapole with the multipoles distributed on the atom sites. Dipole-dipole, dipole-quadrupole, and quadrupole-quadrupole distributed polarizabilities are used to represent the response of the multipoles to an electric field. We compare the model against two large databases consisting of 43,844 3-body terms and 3,603 4-body terms obtained from high level ab initio calculations previously used to fit the MB-pol and q-AQUA interaction potentials. The classical induction model with no adjustable parameters reproduces the ab-initio 3- and 4-body terms contained in these teo Databases with a Root-Mean-Square-Error (RMSE) of 0.104/0.058 and a Mean-Absolute-Error (MAE) of 0.054/0.026 kcal/mol, respectively, results that are on a par with those obtained 1 by fitting the same data using tens of thousands of Permutationally Invariant Polynomials (PIPs). This demonstrates the accuracy of this physically motivated model in describing the 3- and 4-body terms in the interactions between water molecules with no adjustable parameters. The triple-dipole-dispersion energy was included in the 3-body energy and was found to be small but not quite negligible. The model represents a practical, efficient and transferable approach for obtaining accurate non-additive interactions for multi-component systems without the need of performing tens of thousands of high level electronic structure calculations and fitting them with tens of thousands of PIPs.

molecular analysis water, aqueous↗

BEYONDPLANCK XI. Bayesian CMB analysis with sample-based end-to-end error propagation

We present posterior sample-based cosmic microwave background (CMB) constraints from Planck LFI and WMAP observations as derived through global end-to-end Bayesian processing within the BeyondPlanck framework. We first use these samples to study correlations between CMB, foreground, and instrumental parameters, and we identify a particularly strong degeneracy between CMB temperature fluctuations and free-free emission on intermediate angular scales (400 ≲ ℓ ≲ 600), which is mitigated through model reduction, masking, and resampling. We compare our posterior-based CMB results with previous Planck products, and find generally good agreement, although with notably higher noise due to our exclusion of HFI data. We find a best-fit CMB dipole amplitude of 3362.7 ± 1.4 µK, in excellent agreement with previous Planck results. The quoted dipole uncertainty is derived directly from the sampled posterior distribution, and does not involve any ad hoc contributions for Planck instrumental systematic effects. Similarly, we find a temperature quadrupole amplitude of ${σ}_{2}^{TT}$ = 229 ± 97 µK 2 , which is in good agreement with previous results in terms of the amplitude, but the uncertainty is an order of magnitude larger than the naive diagonal Fisher uncertainty. Relatedly, we find lower evidence for a possible alignment between the quadrupole and octopole than previously reported due to a much larger scatter in the individual quadrupole coefficients, caused both by marginalizing over a more complete set of systematic effects, but also by our more conservative analysis mask required to mitigate the free-free degeneracy. For higher multipoles, we find that the angular temperature power spectrum is generally in good agreement with both Planck and WMAP. At the same time, we note that this is the first time the sample-based asymptotically exact Blackwell-Rao estimator has been successfully established for multipoles up to ℓ ≤ 600, and it now accounts for the majority of the cosmologically important information. Overall, this analysis demonstrates the unique capabilities of the Bayesian approach with respect to end-to-end systematic uncertainty propagation, and we believe it can and should play an important role in the analysis of future CMB experiments. Cosmological parameter constraints are presented in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

Discovery of multiple p-mode pulsation frequencies in the roAp star, HD 86181

ABSTRACT We report the frequency analysis of a known roAp star, HD 86181 (TIC 469246567), with new inferences from Transiting Exoplanet Survey Satellite (TESS) data. We derive the rotation frequency to be νrot = 0.48753 ± 0.00001 d−1. The pulsation frequency spectrum is rich, consisting of two doublets and one quintuplet, which we interpret to be oblique pulsation multiplets from consecutive, high-overtone dipole, quadrupole, and dipole modes. The central frequency of the quintuplet is 232.7701 d−1 (2.694 mHz). The phases of the sidelobes, the pulsation phase modulation, and a spherical harmonic decomposition all show that the quadrupole mode is distorted. Following the oblique pulsator model, we calculate the rotation inclination, i, and magnetic obliquity, β, of this star, which provide detailed information about the pulsation geometry. The i and β derived from the best fit of the pulsation amplitude and phase modulation to a theoretical model, including the magnetic field effect, slightly differ from those calculated for a pure quadrupole, indicating the contributions from ℓ = 4, 6, 8,... are small. Non-adiabatic models with different envelope convection conditions and physics configurations were considered for this star. It is shown that models with envelope convection almost fully suppressed can explain the excitation at the observed pulsation frequencies.

Shi, Fangfei (ORCID:0000000323998216)↗

Exploring the role of high- j configurations in collective observables through the Coulomb excitation of 106 Cd

In this work, the shape and collectivity of 106 Cd was investigated via a sub-barrier-energy Coulomb excitation experiment performed at the NSCL ReA3 facility using the JANUS setup. Transition matrix elements between low-lying states were found to agree with adopted values, and information on the shape and collectivity of higher-lying states was extracted for the first time. Locally-optimized large-scale shell-model calculations were found to describe well the B(E2) transition strengths but failed to reproduce the spectroscopic quadrupole moments Q s . An analysis of the E2 rotational invariants and the normalized quadrupole moment q s indicates that this may be due to a significant degree of triaxiality in 106 Cd which is not captured by the present shell-model calculations. Analogous calculations for the Fe isotopes (two protons below the Z = 28 magic number) reveal the critical role of high-j neutron configurations for the description of quadrupole moments in the heavy Fe and Cd isotopes (two protons below magic Z = 50), but this effect is insufficient to explain the shape of 106 Cd, posing a puzzle for the understanding of nuclear structure towards N = 50.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of Hexadecapole Deformation in Uranium-238 at the Relativistic Heavy Ion Collider

State-of-the-art hydrodynamic simulations of the quark-gluon plasma are unable to reproduce the elliptic flow of particles observed at the BNL Relativistic Heavy Ion Collider (RHIC) in relativistic 238 U + 238 U collisions when they rely on information obtained from low-energy experiments for the implementation of deformation in the colliding 238 U ions. Here, we show that this is due to an inappropriate treatment of well-deformed nuclei in the modeling of the initial conditions of the quark-gluon plasma. Past studies have identified the deformation of the nuclear surface with that of the nuclear volume, though these are different concepts. In particular, a volume quadrupole moment can be generated by both a surface hexadecapole and a surface quadrupole moment. This feature was so far neglected in the modeling of heavy-ion collisions, and is particularly relevant for nuclei like 238 U, which is both quadrupole deformed and hexadecapole deformed. With rigorous input from Skyrme density functional calculations, we show that correcting for such effects in the implementation of nuclear deformations in hydrodynamic simulations restores agreement with BNL RHIC data. This brings consistency to the results of nuclear experiments across energy scales, and demonstrates the impact of the hexadecapole deformation of 238 U on high-energy collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of MQXF Quench Heater Insulation Strength and Test of Modified Design

The HL-LHC interaction region magnet triplets (Q1,Q2, and Q3) will be composed of superconducting Nb 3 Sn quadrupoles. The MQXF quadrupole protection system is based on CLIQ (Coupling-Loss Induced Quench system) and outer layer quench heaters. Furthermore, this paper reports a summary of quench heaters to coil high voltage tests performed on MQXF short and long coils in air after fabrication, and in air and He gas after magnet training. Breakdown voltage values demonstrate good margin with respect to the Electrical design criteria for the HL-LHC inner triplet mag-nets. A modification in the quench heater installation-with an extra layer of fiber glass between the coil and the quench heater trace-has been proposed and tested in a mirror magnet to further increase electrical margins. Results demonstrated improvements of high voltage margin at the expense of a clear increase of hot spot temperature.The baseline heater to coil insulation was assessed to be able to guarantee safe operation for the Nb 3 Sn quadrupole magnets for the interaction regions of HL-LHC.

43 PARTICLE ACCELERATORS↗