Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pv”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

PV_LIB Toolbox v. 1.3

PV_LIB comprises a library of Matlab? code for modeling photovoltaic (PV) systems. Included are functions to compute solar position and to estimate irradiance in the PV system's plane of array, cell temperature, PV module electrical output, and conversion from DC to AC power. Also included are functions that aid in determining parameters for module performance models from module characterization testing. PV_LIB is open source code primarily intended for research and academic purposes. All algorithms are documented in openly available literature with the appropriate references included in comments within the code.

Source record↗

PV Shading Database [SWR-16-36]

The software is a simplified method for modeling the impact of arbitrary partial shading conditions on PV array performance. The software implements a simple method for modeling shade loss: a database of shade impact results (loss percentages), generated using a validated, detailed simulation tool and encompassing a wide variety of shading scenarios. The database is intended to predict shading losses in crystalline silicon PV arrays and is accessed using basic inputs generally available in any PV simulation tool. Performance predictions using the database are within 1-2% of measured data for several partially shaded PV systems, and within 1% of those predicted by the full, detailed simulation tool on an annual basis. The shade loss database shows potential to considerably improve performance prediction for partially shaded PV systems.

Janzou, Steven↗

PV Generation and Load Forecasting for Adjuntas PR Community Microgrids

Existing frameworks to forecast time-series photovoltaic (PV) output power and consumer load for microgrid operations and controls assume a near-continuous availability of real-time input features from the field assets such as PV inverters, energy meters, and weather station. These incoming data points are used to periodically retrain models and update forecast snapshots over a moving horizon window, be it one hour-ahead, one-day ahead, or one-week ahead. However, such frameworks are not resilient to disruptions in data availability caused by losses in communications between the field sensors and data loggers. Hence, there is a need for programs that assume no availability of real-time microgrid asset data and still make reliable forecasts that can be used for decision-making. Such programs would be apt to function in extreme weather events such as hurricanes and would use lightweight recursive time-series models to independently forecast solar irradiance and ambient temperature, then compute PV power from those forecasts, as well as independently forecast consumer load. The codebase performs forecasting for the scenario of when the microgrid does not have a reliable access to forecasts or real-time observations of solar irradiance (I) and ambient temperature (AT) and load (Load) to be able to adequately forecast, in real-time, the PV power production or a business' load. In this case, using historical values of PV power and load, a univariate forecasting of generation and consumption are respectively made. The use-case in particular has two sub-scenarios: one, a normal 7-day ahead forecast where the unavailability of real-time data is assumed due to infrastructure issues such as loss of communication or sensor maintenance or service downtimes. Whereas a hurricane-caused unavailability of real-time data requires a second model trained specifically on historical hurricane days to be able to capture the extreme day behavior of generation in particular, and load if applicable. A gradient boosted regression tree comprises an ensemble of additive models that map between the input of historical values (be it irradiance, temperature, or load) and their corresponding output forecasts of a given horizon such that the individual learner predictions are summed up over the total number of such learners in the ensemble to produce an aggregate forecast. A weighting mechanism is applied to the training data in each iteration, where actual and forecast values are compared to penalize incorrect forecasts by increasing the weight and reducing it to reward correct forecasts. The code's benefits are that it: (a) accounts for a contingency where communication loss renders newly measured real-time data unavailable for model tuning and snapshot updates; (b) presents blind forecasting that recursively determines the next time-step value in a horizon using the forecast of the same attribute from a prior step; and (c) employs lightweight models that, once trained, can reliably generalize for different horizons, which make them suitable for enhancing the resilience of field microgrids prone to extreme events that encounter disruptions to data availability.

Sundararajan, Aditya [Oak Ridge National Laborator↗

OPET Hardware (Open PV Electrical Tool Hardware) [SWR-25-42]

OPET (Open-source Photovoltaic Electrical Tool) is used for performance measurements of solar photovoltaic (PV) devices in the field under natural sunlight or in the lab under artificial light. Its primary use is in research and development of solar cells and modules, specifically in reliability and durability research of PV devices. Some features and functions include: -IV curve measurements with linear or cosine distributed measurement points -PV device active loading at open circuit voltage (Voc), short circuit current (Isc) and maximum power point (Pmp) -Bias power supply to overcome series resistance in contact wires for Isc measurements and loading -PV voltage input in five ranges from 1V to 100V -PV current input ranges -Low current version, six current ranges from 1.1mA to 340mA -High current version, six current ranges from 50mA to 15A -IO ports for I2C and SPI temperature sensor Arduino extension boards -Integrated fan control This repository contains everything relating to the hardware of the OPET device. If you are looking for the firmware or software repositories, links are below: https://github.com/NREL/opet-firmware https://github.com/NREL/opet-control

McDanold, Byron [National Renewable Energy Laborat↗

Ota City: Characterizing Output Variability from 553 Homes with Residential PV Systems on a Distribution Feeder

This report describes in-depth analysis of photovoltaic (PV) output variability in a high-penetration residential PV installation in the Pal Town neighborhood of Ota City, Japan. Pal Town is a unique test bed of high-penetration PV deployment. A total of 553 homes (approximately 80% of the neighborhood) have grid-connected PV totaling over 2 MW, and all are on a common distribution line. Power output at each house and irradiance at several locations were measured once per second in 2006 and 2007. Analysis of the Ota City data allowed for detailed characterization of distributed PV output variability and a better understanding of how variability scales spatially and temporally. For a highly variable test day, extreme power ramp rates (defined as the 99 th percentile) were found to initially decrease with an increase in the number of houses at all timescales, but the reduction became negligible after a certain number of houses. Wavelet analysis resolved the variability reduction due to geographic diversity at various timescales, and the effect of geographic smoothing was found to be much more significant at shorter timescales.

14 SOLAR ENERGY↗

Capacity Value of PV and Wind Generation in the NV Energy System

Calculation of photovoltaic (PV) and wind power capacity values is important for estimating additional load that can be served by new PV or wind installations in the electrical power system. It also is the basis for assigning capacity credit payments in systems with markets. Because of variability in solar and wind resources, PV and wind generation contribute to power system resource adequacy differently from conventional generation. Many different approaches to calculating PV and wind generation capacity values have been used by utilities and transmission operators. Using the NV Energy system as a study case, this report applies peak-period capacity factor (PPCF) and effective load carrying capability (ELCC) methods to calculate capacity values for renewable energy sources. We show the connection between the PPCF and ELCC methods in the process of deriving a simplified approach that approximates the ELCC method. This simplified approach does not require generation fleet data and provides the theoretical basis for a quick check on capacity value results of PV and wind generation. The diminishing return of capacity benefit as renewable generation increases is conveniently explained using the simplified capacity value approach.

capacity value↗

Sacramento Municipal Utility District PV and Smart Grid Pilot at Anatolia

Under DE-FOA-0000085 High Penetration Solar Deployment, the U. S. Department of Energy funded agreements with SMUD and Navigant Consulting, SunPower, GridPoint, the National Renewable Energy Laboratory, and the California Energy Commission for this pilot demonstration project. Funding was $5,962,409.00. Cost share of $500,000 was also provided by the California Energy Commission. The project has strategic implications for SMUD, other utilities and the PV and energy-storage industries in business and resource planning, technology deployment and asset management. These implications include: -At this point, no dominant business models have emerged and the industry is open for new ideas. -Demonstrated two business models for using distributed PV and energy storage, and brainstormed several dozen more, each with different pros and cons for SMUD, its customers and the industry. -Energy storage can be used to manage high penetrations of PV and mitigate potential issues such as reverse power flow, voltage control violations, power quality issues, increased wear and tear on utility equipment, and system wide power supply issues. - Smart meters are another tool utilities can use to manage high penetrations of PV. The necessary equipment and protocols exist, and the next step is to determine how to integrate the functionality with utility programs and what level of utility control is required. - Time-of-use rates for the residential customers who hosted energy storage systems did not cause a significant change in energy usage patterns. However, the rates we used were not optimized for PV and energy storage. Opportunities exist for utilities to develop new structures.

14 SOLAR ENERGY↗

Experimental Comparison of PV-Smoothing Controllers using Distributed Generators

The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

14 SOLAR ENERGY↗

A Best Practice for Developing Availability Guarantee Language in Photovoltaic (PV) O&M Agreements.

This document outlines the foundation for developing language that can be utilized in an Equipment Availability Guarantee, typically included in an O&M services agreement between a PV system or plant owner and an O&M services provider, or operator. Many of the current PV O&M service agreement Availability Guarantees are based on contracts used for traditional power generation, which create challenges for owners and operators due to the variable nature of grid-tied photovoltaic generating technologies. This report documents language used in early PV availability guarantees and presents best practices and equations that can be used to more openly communicate how the reliability of the PV system and plant equipment can be expressed in an availability guarantee. This work will improve the bankability of PV systems by providing greater transparency into the equipment reliability state to all parties involved in an O&M services contract.

Klise, Geoffrey Taylor↗

Analysis of PV Advanced Inverter Functions and Setpoints under Time Series Simulation.

Utilities are increasingly concerned about the potential negative impacts distributed PV may have on the operational integrity of their distribution feeders. Some have proposed novel methods for controlling a PV system's grid - tie inverter to mitigate poten tial PV - induced problems. This report investigates the effectiveness of several of these PV advanced inverter controls on improving distribution feeder operational metrics. The controls are simulated on a large PV system interconnected at several locations within two realistic distribution feeder models. Due to the time - domain nature of the advanced inverter controls, quasi - static time series simulations are performed under one week of representative variable irradiance and load data for each feeder. A para metric study is performed on each control type to determine how well certain measurable network metrics improve as a function of the control parameters. This methodology is used to determine appropriate advanced inverter settings for each location on the f eeder and overall for any interconnection location on the feeder.

14 SOLAR ENERGY↗

Determination of Duty Cycle for Energy Storage Systems in a PV Smoothing Application

This report supplements the document, "Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems," issued in a revised version in April 2016 (see [4]), which will include the photovoltaic (PV) smoothing application for an energy storage system (ESS). This report provides the background and documentation associated with the determination of a duty cycle for an ESS operated in a PV smoothing application for the purpose of measuring and expressing ESS performance in accordance with the ESS performance protocol. ACKNOWLEDGEMENTS The authors gratefully acknowledge the support of Dr. Imre Gyuk, program manager for the DOE Energy Storage Systems Program. The authors would also like to express their appreciation to all the stakeholders who participated as members of the PV Smoothing Subgroup. Without their thoughtful input and recommendations, the definitions, metrics, and duty cycle provided in this report would not have been possible. A complete listing of members of the PV Smoothing Subgroup appears in the first chapter of this report. Special recognition should go to the staffs at Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL) in collaborating on this effort. In particular, Mr. David Conover and Dr. Vish Viswanathan of PNNL and Dr. Summer Ferreira of SNL were especially helpful in their suggestions for the determination of a duty cycle for the PV Smoothing application.

25 ENERGY STORAGE↗

Validation of PV-RPM Code in the System Advisor Model.

This paper describes efforts made by Sandia National Laboratories (SNL) and the National Renewable Energy Laboratory (NREL) to validate the SNL developed PV Reliability Performance Model (PV - RPM) algorithm as implemented in the NREL System Advisor Model (SAM). The PV - RPM model is a library of functions that estimates component failure and repair in a photovoltaic system over a desired simulation period. The failure and repair distributions in this paper are probabilistic representations of component failure and repair based on data collected by SNL for a PV power plant operating in Arizona. The validation effort focuses on whether the failure and repair dist ributions used in the SAM implementation result in estimated failures that match the expected failures developed in the proof - of - concept implementation. Results indicate that the SAM implementation of PV - RPM provides the same results as the proof - of - concep t implementation, indicating the algorithms were reproduced successfully.

97 MATHEMATICS AND COMPUTING↗

Solar Plus: A Holistic Approach to Distributed Solar PV

Solar 'plus' refers to an emerging approach to distributed solar photovoltaic (PV) deployment that uses energy storage and controllable devices to optimize customer economics. The solar plus approach increases customer system value through technologies such as electric batteries, smart domestic water heaters, smart air-conditioner (AC) units, and electric vehicles We use an NREL optimization model to explore the customer-side economics of solar plus under various utility rate structures and net metering rates. We explore optimal solar plus applications in five case studies with different net metering rates and rate structures. The model deploys different configurations of PV, batteries, smart domestic water heaters, and smart AC units in response to different rate structures and customer load profiles. The results indicate that solar plus improves the customer economics of PV and may mitigate some of the negative impacts of evolving rate structures on PV economics. Solar plus may become an increasingly viable model for optimizing PV customer economics in an evolving rate environment.

14 SOLAR ENERGY↗

Income Trends of Residential PV Adopters: An analysis of household-level income estimates [PowerPoint presentation]

The residential photovoltaic (PV) market has expanded rapidly over the past decade, but questions exist about how equitably that growth has occurred across income groups. Prior studies have investigated this question but are often limited by narrow geographic study regions, now-dated analysis timeframes, or coarse estimates of PV-adopter incomes. At the same time, a spate of new programs and initiatives, as well as innovations in business models and product design, have emerged in recent years with the aim of making solar more accessible and affordable to broader segments of the population. Yet, many of those efforts are proceeding without robust underlying information about the income characteristics of recent residential PV adopters. This work aims to establish basic factual information about income trends among U.S. residential solar adopters, with some emphasis on low- and moderate-income (LMI) households. The analysis is unique in its relatively extensive coverage of the U.S. solar market, relying on Berkeley Lab’s Tracking the Sun dataset, which contains project-level data for the vast majority of all residential PV systems in the country (a subset of which are ultimately included in the analysis sample). This analysis is also unique in its use of household-level income estimates that provide a more-precise characterization of PV-adopter incomes than in most prior studies.

14 SOLAR ENERGY↗

Commercial PV Property Appraiser Survey: Summary of Results

Solar photovoltaic systems can be a valuable asset when attached to a property. Therefore, providing market participants with information and tools to credibly assess the value that PV adds to property is important. To that end, LBNL, SNL and AI conducted a survey of commercial appraisers to assess methods of valuing commercial properties with existing PV systems, current trends, and factors that help or hurt market adoption. The survey elicited 44 responses. Although an overwhelming majority of the respondents had conducted appraisals of properties with solar, how such systems are valued varied widely. Less than half of the respondents reported utilizing AI-endorsed tools such as PV Value ® or Ei Value ® for assignments, which may indicate a lack of awareness that such tools exist. A number of appraisers have taken the AI Residential & Commercial Valuation of Solar course and/or pursued a number of self-study avenues to increase their knowledge of PV systems. A majority indicated that they would be interested in taking an online course if it was offered. Overall, preliminary results point to a need for standardization of valuation metrics and a method of disseminating (e.g. classes) and utilizing (e.g. assessment tools) such metrics in order for appraisers to consistently evaluate and increase demand of properties with PV systems.

14 SOLAR ENERGY↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

PV Module Design for Recycling Guidelines

The global growth of clean energy technology deployment will be inexorably followed by a parallel growth of end-of-life (EOL) products that bring both challenges and opportunities. Cumulatively, by 2050, estimates project 78 million tonnes of raw materials embodied in the mass of EOL photovoltaic (PV) modules. Owing partly to concern that the projected growth of clean energy technologies could become constrained by availability of raw materials, despite ongoing dematerialization efforts, significant attention under the umbrella of circular economy has been brought to recycling these technologies at EOL. Yet PV has not been designed with recycling at EOL in mind, and it presents challenges to returning embodied raw materials back to use in new products through recycling. This study aims to inform future designs to improve recyclability through synthesis of prior published works augmented by novel recommendations that result in a set of general design for recycling (DfR) guidelines, with a subset specific to PV modules. We further discuss how established trends in design of PV modules could affect recyclability. If adopted today, application of these DfR guidelines could help to mitigate tomorrow's resource scarcity, lower the barriers and cost for PV recycling, and enable a circular economy during the energy transition.

14 SOLAR ENERGY↗

Operations, maintenance, and cost considerations for PV+Storage in the United States

Battery storage systems are increasingly being installed at photovoltaic (PV) sites to address supply-demand balancing needs. Although there is some understanding of costs associated with PV operations and maintenance (O&M), costs associated with emerging technologies such as PV plus storage lack details about the specific systems and/or activities that contribute to the cost values. This study aims to address this gap by exploring the specific factors and drivers contributing to utility-scale PV plus storage systems (UPVS) O&M activities costs, including how technology selection, data collection, and related and ongoing challenges. Specifically, we used semi-structured interviews and questionnaires to collect information and insights from utility-scale owners and operators. Data was collected from 14 semi-structured interviews and questionnaires representing 51.1 MW with 64.1 MWh of installed battery storage capacity within the United States (U.S.). Differences in degradation rate, expected life cycle, and capital costs are observed across different storage technologies. Most O&M activities at UPVS related to correcting under-performance. Fires and venting issues are leading safety concerns, and owner operators have installed additional systems to mitigate these issues. There are ongoing O&M challenges due the lack of storage-specific performance metrics as well as poor vendor reliability and parts availability. Insights from this work will improve our understanding of O&M consideration at PV plus storage sites.

14 SOLAR ENERGY↗