Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pupil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Optimizing coronagraph designs to minimize their contrast sensitivity to low-order optical aberrations

The presence of optical aberrations in the entrance pupil of a coronagraph causes the stellar light to scatter about the occulting spot, reducing the effective contrast achievable. Even if these aberrations are sufficiently corrected with a deformable mirror to enable planet detection, small drifts in the optical alignment of the telescope introduce additional low-order aberrations.

Shaklan, Stuart B.↗

Development of a Broadband Achromatic Twyman-Green Interferometer

A modified Twyman-Green interferometer is in use that makes possible wavefront testing of optical filters at any wavelength from 200 to 1100 nanometers. The use of mirrors for collimation and pupil imaging makes the intrument achromatic, and therefore the focus is fixed over the entire bandwidth.

interferometer↗

LISA : Pointing sensor development stand

We are developing a pointing sensor as part of the technology development effort for the Laser Interferometer Space Antenna (LISA) mission. The sensor will measure the angle between two beams, by measuring the phase difference in the heterodyne frequency on different sides of the pupil plane. In LISA, one beam would be from the local laser, while the other beam comes from a different spacecraft. The beam coming from the other space craft will have a Doppler shift due to changes in the orbits of the satellites. The phase difference across the aperture will be measured to align the incoming and outgoing beams.

LISA↗

Coronagraph Design Optimization for Segmented Aperture Telescopes

The goal of directly imaging Earth-like planets in the habitable zone of other stars has motivated the design of coronagraphs for use with large segmented aperture space telescopes. In order to achieve an optimal trade-o between planet light throughput and di racted starlight suppression, we consider coronagraphs comprised of a stage of phase control implemented with deformable mirrors (or other optical elements), pupil plane apodization masks (gray scale or complex valued), and focal plane masks (either amplitude only or complex-valued, including phase only such as the vector vortex coronagraph). The optimization of these optical elements, with the goal of achieving 10 or more orders of magnitude in the suppression of on-axis (starlight) di racted light, represents a challenging non-convex optimization problem with a nonlinear dependence on control degrees of freedom. We develop a new algorithmic approach to the design optimization problem, which we call the "Auxiliary Field Optimization" (AFO) algorithm. The central idea of the algorithm is to embed the original optimization problem, for either phase or amplitude (apodization) in various planes of the coronagraph, into a problem containing additional degrees of freedom, speci cally ctitious "auxiliary" electric elds which serve as targets to inform the variation of our phase or amplitude parameters leading to good feasible designs. We present the algorithm, discuss details of its numerical implementation, and prove convergence to local minima of the objective function (here taken to be the intensity of the on-axis source in a "dark hole" region in the science focal plane). Finally, we present results showing application of the algorithm to both unobscured o -axis and obscured on-axis segmented telescope aperture designs. The application of the AFO algorithm to the coronagraph design problem has produced solutions which are capable of directly imaging planets in the habitable zone, provided end-to-end telescope system stability requirements can be met. Ongoing work includes advances of the AFO algorithm reported here to design in additional robustness to a resolved star, and other phase or amplitude aberrations to be encountered in a real segmented aperture space telescope.

Redding, Dave↗

Dynamic Testbed Demonstration of WFIRST Coronagraph Low Order Wavefront Sensing and Control (LOWFS/C)

To maintain the required performance of WFIRST Coronagraph in a realistic space environment, a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem is necessary. The LOWFS/C uses a Zernike wavefront sensor (ZWFS) with the phase shifting disk combined with the starlight rejecting occulting mask. For wavefront error corrections, WFIRST LOWFS/C uses a fast steering mirror (FSM) for line-of-sight (LoS) correction, a focusing mirror for focus drift correction, and one of the two deformable mirrors (DM) for other low order wavefront error (WFE) correction. As a part of technology development and demonstration for WFIRST Coronagraph, a dedicated Occulting Mask Coronagraph (OMC) testbed has been built and commissioned. With its configuration similar to the WFIRST flight coronagraph instrument the OMC testbed consists of two coronagraph modes, Shaped Pupil Coronagraph (SPC) and Hybrid Lyot Coronagraph (HLC), a low order wavefront sensor (LOWFS), and an optical telescope assembly (OTA) simulator which can generate realistic LoS drift and jitter as well as low order wavefront error that would be induced by the WFIRST telescope’s vibration and thermal changes. In this paper, we will introduce the concept of WFIRST LOWFS/C, describe the OMC testbed, and present the testbed results of LOWFS sensor performance. We will also present our recent results from the dynamic coronagraph tests in which we have demonstrated of using LOWFS/C to maintain the coronagraph contrast with the presence of WFIRST-like line-of-sight and low order wavefront disturbances.

Zhou, Hanying↗

Fabrication of coronagraph masks and laboratory scale star-shade masks: characteristics, defects and performance

NASA WFIRST mission has planned to include a coronagraph instrument to find and characterize exoplanets. Masks are needed to suppress the host star light to better than 10-8 – 10-9 level contrast over a broad bandwidth to enable the coronagraph mission objectives. Such masks for high contrast coronagraphic imaging require various fabrication technologies to meet a wide range of specifications, including precise shapes, micron scale island features, ultra-low reflectivity regions, uniformity, wave front quality, etc. We present the technologies employed at JPL to produce these pupil plane and image plane coronagraph masks, and lab-scale external occulter masks, highlighting accomplishments from the high contrast imaging testbed (HCIT) at JPL and from the high contrast imaging lab (HCIL) at Princeton University. Inherent systematic and random errors in fabrication and their impact on coronagraph performance are discussed with model predictions and measurements.

Casey Wilson, Robert↗

High Accuracy Coronagraph Flight Model For WFIRST–CGI Raw Contrast Sensitivity Analysis

A high-accuracy high-fidelity flight wavefront control (WFC) model is developed for detailed raw contrast sensitivity analysis of WFIRST-CGI. Built upon features of recently testbed validated model, it is further refined to combine a full Fresnel propagation diffraction model for high accuracy contrast truth evaluation, and an economical compact model for WFC purposes. Extensive individual raw contrast error sensitivities are evaluated systematically, both as known imperfections and as unknown calibration errors, for both spectroscopy mode and wide field-of-view mode with shaped pupil coronagraph. More than 90 distinct error items were identified, including system aberrations, optical misalignment, component manufacturing error, telescope interface related errors, etc. The result forms the basis for raw contrast error budget flow down to a sub-system level, where detailed specifications needed to aid in component design and manufacturing, mechanical alignment and instrument integration, and verification and validation operations. Evaluations are mostly automated, making it relatively easy for repeat runs of revised design or at new desired error quantity. Top error sensitivities and contrast floor contributors are discussed and several observations are noted.

Poberezhskiy, Ilya↗

WFIRST Coronagraph Flight Performance Modeling

As it has for the past few years, numerical modeling is being used to predict the on-orbit, high-contrast imaging performance of the WFIRST coronagraph, which was recently defined to be solely a technology demonstrator. A consequence has been a realignment of modeling priorities and revised applications of modeling uncertainty factors and margins, which apply to multiple factors such as pointing and wavefront jitter, thermally-induced deformations, polarization, and aberration sensitivities. At the same time, the models have increased in fidelity as additional parameters have been added, such as time-dependent pupil shear and mid-spatial-frequency deformations of the primary and secondary mirrors, detector effects, and reaction-wheel-speed-dependent pointing and wavefront jitter.

Trauger, John↗

Optical Performance Prediction of the Thirty Meter Telescope after Initial Alignment Using Optical Modeling

We present an estimate of the optical performance of the Thirty Meter Telescope (TMT) after execution of the full telescope alignment plan. The TMT alignment is performed by the Global Metrology System (GMS) and the Alignment and Phasing System (APS). The GMS first measures the locations of the telescope optics and instruments as a function of elevation angle. These initial measurements will be used to adjust the optics positions and build initial elevation look-up tables. Then the telescope is aligned using starlight as the input for the APS at multiple elevation angles. APS measurements are used to refine the telescope alignment to build elevation and temperature dependent look-up tables. Due to the number of degrees of freedom in the telescope (over 10,000), the ability of the primary mirror to correct aberrations on other optics, the tight optical performance requirements and the multiple instrument locations, it is challenging to develop, test and validate these alignment procedures. In this paper, we consider several GMS and APS operational scenarios. We apply the alignment procedures to the model-generated TMT, which consists of various quasi-static errors such as polishing errors, passive supports errors, thermal and gravity deformations and installation position errors. Using an integrated optical model and Monte-Carlo framework, we evaluate the TMT’s aligned states using optical performance metrics at multiple instrument and field of view locations. The optical performance metrics include the Normalized Point Source Sensitivity (PSSN), RMS wavefront error before and after Adaptive Optics (AO) correction, pupil position change, and plate scale distortion.

Rogers, John↗

WFIRST Low Order Wavefront Sensing and Control Testbed Performance under Flight Like Photon Flux

To maintain the required performance for the WFIRST Coronagraph Instrument (CGI) in a realistic space environment, a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem is necessary. The WFIRST CGI LOWFS/C subsystem would use the Zernike wavefront sensor, which has the phase-shifting disk combined with the coronagraph’s focal plane mask, to sense the low-order wavefront drift and line-of-sight (LoS) error using the rejected starlight. The dynamic tests on JPL’s on the Occulting Mask Coronagraph (OMC) Testbed have demonstrated that LOWFS/C can maintain coronagraph contrast to better than 10-8 in presence of WFIRST-like line of sight and low order wavefront disturbances in both Shaped Pupil Coronagraph (SPC) and Hybrid Lyot Coronagraph (HLC) modes. However, the previous dynamic tests have been done using a bright source with photon flux equivalent to stellar magnitude of Mv = -3.5. The LOWFS/C technology development continues on the OMC testbed especially in evaluating and improving the LOWFS/C performance under the realistic photon flux that is equivalent to WFIRST Coronagraph target stars. Our recent testbed tests have demonstrated that the LOWFS/C can work cohesively with the stellar light suppression wavefront control, which brings broad band coronagraph contrast from 1x10-6 to 6x10-9, while LOWF/C is simultaneously suppressing the WFIRST like LoS and low order wavefront drift disturbances on a source that photon flux is equivalent to a Mv = 2 star. This demonstration mimics the CGI initial dark hole establish process on a bright reference star. We also demonstrated on the testbed that LOWFS/C can maintain the coronagraph contrast by suppressing the WFIRST like line-of-sight disturbances on a fainter Mv = 5 star. This mimics scenario of CGI science target observations. In this paper we will present the recent testbed results on LOWFS/C LoS loops and low order wavefront error correction loop performance on the flight like photon flux.

Truong, Tuan↗

Hybrid Lyot Coronagraph for WFIRST: High Contrast Testbed Demonstration in Flight-like Low Flux Environment

In order to validate required operation of the proposed Wide-Field InfraRed Survey Telescope (WFIRST) coronagraph instrument, we have built a testbed in Jet Propulsion Laboratory (JPL), which is analogous to the baseline WFIRST coronagraph instrument architecture. Since its birth in 2016, this testbed, named as Occulting Mask Coronagraph (OMC) testbed, has demonstrated several crucial technological milestones: Broadband high contrast demonstration in both Hybrid Lyot Coronagraph (HLC) and Shape Pupil Coronagraph (SPC) modes while the Low Order Wavefront Sensing and Control (LOWFS/C) subsystem senses and corrects the dynamic flight-like wavefront disturbances. In this paper, we present up-to-date progress of HLC mode demonstration in the OMC testbed. While injecting the flight-like low photon flux starlight with expected Line of Sight (LoS) and Wavefront Error (WFE) perturbation to the OMC testbed, we demonstrate generating high contrast dark hole images. We first study the expected photon flux in actual flight environment, and estimate detection noise and estimation accuracy of the complex electric field if the wavefront sensing algorithm is used based on the pair-wise difference imaging. Then, we introduce our improved scheme to mitigate this photon-starved flight-like low flux environment. As a result, we generate a dark hole that meets the WFIRST raw contrast requirements using the 2nd magnitude star light. We establish the key ideas, describe test setups, and demonstrate test results with data analysis.

Wilson, Daniel↗

The LUVOIR Extreme Coronagraph for Living Planetary Systems (ECLIPS) II. Performance Evaluation, Aberration Sensitivity Analysis and Exoplanet Detection Simulations

Future space missions such as the Large UV-Optical-Infrared Surveyor (LUVOIR) and the Habitable Exoplanet Observatory (HabEx) require coronagraphs with active wavefront control to suppress starlight to discover and characterize habitable exoplanets. The Extreme Coronagraph for Living Planetary Systems (ECLIPS) is the coronagraph instrument on the LUVOIR Surveyor mission concept, an 8–15m segmented telescope. ECLIPS is split into three channels: UV (200 to 400 nm), optical (400 nm to 850 nm), and NIR (850 nm to 2.0 microns), with each channel equipped with two deformable mirrors for wavefront control, a suite of coronagraph masks, a low-order/out-of-band wavefront sensor, and separate science imagers and spectrographs. The Apodized Pupil Lyot Coronagraph (APLC) and the Vector Vortex Coronagraph (VVC) are the baselined mask technologies for ECLIPS to enable the required 10 -10 contrast for observations in the habitable zones of nearby stars. Their performance depends on active wavefront sensing and control, as well as metrology subsystems to compensate for aberrations induced by segment errors (piston and tip/tilt, among others), secondary mirror misalignment, and global low-order wavefront errors. Here we present the latest results of the simulation of these effects for the two technologies and discuss the achieved contrast for exoplanet detection and characterization after closed-loop wavefront estimation and control algorithms have been applied. Finally, we show simulated observations using high-fidelity spatial and spectral input models of complete planetary systems generated with the Haystacks code framework.

Roser Juanola-Parramon↗

Characterizing Deformable Mirrors for the MagAO-X Instrument

The MagAO-X instrument is a new extreme adaptive optics system for high-contrast imaging at visibleand near-infrared wavelengths on the Magellan Clay Telescope. A central component of this system is a 2040-actuatormicroelectromechanical deformable mirror (DM) from Boston Micromachines Corp. that operates at 3.63 kHz forhigh-order wavefront control (the tweeter). Two additional DMs from ALPAO perform the low-order (the woofer)and non-common-path science-arm wavefront correction (the NCPC DM). Prior to integration with the instrument, wecharacterized these devices using a Zygo Verifire Interferometer to measure each DM surface. We present the resultsof the characterization effort here, demonstrating the ability to drive tweeter to a flat of 6.9 nm RMS surface (and 0.56nm RMS surface within its control bandwidth), the woofer to 2.2 nm root mean square (RMS) surface, and the NCPCDM to 2.1 nm RMS surface over the MagAO-X beam footprint on each device. Using focus-diversity phase retrievalon the MagAO-X science cameras to estimate the internal instrument wavefront error (WFE), we further show that theintegrated DMs correct the instrument WFE to 18.7 nm RMS, which, combined with a 11.7% pupil amplitude RMS,produces a Strehl ratio of 0.94 at H↵

Kyle Van Gorkom↗

Optimization of Lyot Coronagrah focal plane masks for improved low-order wavefront sensing

The WFIRST Coronagraph uses a Low-Order Wavefront Sensing and Control (LOWFS/C) subsystem to stabilize the stellar wavefront. This is true for the Hybrid Lyot Coronagraph (HLC), the Shaped Pupil Coronagraph (SPC) spectrograph, and the SPC wide field of view modes. For the SPC spectrograph, we have found via modeling and simulations that a focal plane mask (FPM) with an elliptical phase dimple can reduce the LOWFS errors significantly compared to the conventional, circular phase dimple. For HLC designs, we concurrently optimized the FPM parameters and deformable mirror shapes using our open-source software toolbox, the Fast Linearized Coronagraph Optimizer (FALCO). This process resulted in new FPMs with non-uniform central-area phase modulation. We have found in numerical simulations that such FPMs still provide sufficient LOWFS performance. In this paper, we will present the LOWFS performance for several new HLC and SPC FPM designs.

Riggs, A.J. Eldorado↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗

Design and Performance of the PALM-3000 3.5 kHz Upgrade

PALM-3000 (P3K), the second-generation adaptive optics (AO) instrument for the 5.1 meter Hale telescope atPalomar Observatory, was released as a facility class instrument in October 2011 and has since been used on-skyfor over 600 nights as a workhorse science instrument and testbed for coronagraph and detector development.In late 2019 P3K underwent a significant upgrade to its wavefront sensor (WFS) arm and real-time control(RTC) system to reinforce its position as a state-of-the-art AO facility and extend its faint-end capability forhigh-resolution imaging and precision radial velocity follow-up of Kepler and TESS targets. The main featuresof this upgrade include an EM-CCD WFS camera capable of 3.5 kHz framerates, and an advanced Digital SignalProcessor (DSP) based RTC system to replace the aging GPU based system. Similar to the pre-upgrade system,the Shack-Hartmann wavefront sensor supports multiple pupil sampling modes using a motorized lenslet stage.The default sampling mode with 64×64 subapertures has been re-commissioned on-sky in late 2019, witha successful return to science observations in November 2019. In 64×mode the upgraded system is alreadyachieving K-band Strehl ratios up to 85% on-sky and can lock on natural guide stars as faint as mV=16. A16×16 subaperture mode is scheduled for on-sky commissioning in Fall 2020 and will extend the system’s faintlimit even further. Here we present the design and on-sky re-commissioning results of the upgraded system,dubbed P3K-II.

Vasisht, Gautam↗

Status of NASA’s stellar astrometry testbeds for exoplanet detection: Science and technology overview

Accurate measurement of exoplanetary masses is a critical step in addressing key aspects of NASA's science vision. Measuring masses of Earth-analogs around FGK stars out to 10 pc requires sub-microarcsecond astrometric accuracy, which is not within the capabilities of current instrumentation. Thus, new technology will be required to build an astrometric instrument capable of achieving such performance. This will immediately empower the possibility for dedicated astrometric missions, and perhaps most enticing, it will enable astrometric observing modes to be added (with relatively low cost and impact) to any mission boasting a sufficiently stable direct imaging platform. In this paper, we provide an overview of the scientifi?c goals and technology utilized on two of NASA's astrometry testbeds dedicated to advancing stellar astrometry for exoplanet detection. The ?first one, located at the Jet Propulsion Laboratory (JPL), is dedicated to imaging stellar astrometry on sparse ?fields. The goal of this testbed is to mature the Diffractive Pupil (DP) technology to TRL-5, demonstrating high-?fidelity performance in a relevant environment. This testbed operates in a vacuum tank at the High Contrast Imaging Testbed (HCIT) at JPL. The second testbed, located at NASA Ames Research Center, is dedicated to advancing narrow angle relative astrometry to detect exoplanets around nearby binary stars. The key technology in this testbed is a DP specially designed to measure the angle between two sources on the sky. This testbed operates in air and aims to bring this technology to TRL-4.

Guyon, Olivier↗

Fast reconstruction of off-axis digital holograms

Hologram reconstruction via the angular spectrum method utilizes fast Fourier transforms which quickly but inefficiently shift between image and pupil planes. We demonstrate hologram reconstruction using discrete transforms over limited regions, decreasing computation time 10x.

Wallace, James K↗