Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Performance of the CMS electromagnetic calorimeter in pp collisions at √$_{s}$ = 13 TeV

The operation and performance of the Compact Muon Solenoid(CMS) electromagnetic calorimeter (ECAL) are presented, based ondata collected in pp collisions at√$_{s}$ =13 TeV at the CERN LHC, in the years from 2015 to 2018(LHC Run 2), corresponding to an integrated luminosity of151 fb$^{-1}$. The CMS ECAL is a scintillating lead-tungstatecrystal calorimeter, with a silicon strip preshower detector in theforward region that provides precise measurements of the energy andthe time-of-arrival of electrons and photons. The successfuloperation of the ECAL is crucial for a broad range of physics goals,ranging from observing the Higgs boson and measuring its properties,to other standard model measurements and searches for newphenomena. Precise calibration, alignment, and monitoring of theECAL response are important ingredients to achieve these goals. Toface the challenges posed by the higher luminosity, whichcharacterized the operation of the LHC in Run 2, the proceduresestablished during the 2011–2012 run of the LHC have been revisitedand new methods have been developed for the energy measurement andfor the ECAL calibration. The energy resolution of the calorimeter,for electrons from Z boson decays reaching theECAL without significant loss of energy by bremsstrahlung, wasbetter than 1.8%, 3.0%, and 4.5% in the |η| intervals[0.0,0.8], [0.8,1.5], [1.5, 2.5], respectively. This resultingperformance is similar to that achieved during Run 1 in 2011–2012,in spite of the more severe running conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PickerXL, A Large Deep Learning Model to Measure Arrival Times from Noisy Seismic Signals

Precisely measuring seismic arrival times is a labor-intensive task but is critical for both earthquake monitoring and subsurface imaging. Recently published deep learning models have demonstrated superior performance compared to traditional automatic approaches for picking arrival times. Although existing deep learning models have shown promising results, further advancements are necessary as their performance is not yet satisfactory especially when applied to new regions and station networks. Increasing model size has led to improved performance in other machine learning applications. Here, we aimed to investigate whether enlarging deep learning models can increase performance on accepted benchmarks. We trained three models of varying sizes, small (1X), medium (4X), and large (16X), using globally distributed local and regional earthquake signals and background noise waveforms from a benchmark dataset, Stanford Earthquake Dataset. Our results indicate that the largest model (PickerXL) outperforms both the smaller models and Seisbench implementation of the PhaseNet model, which has the same number of parameters as our small model. The PickerXL model’s enhanced capacity to extract complex patterns from seismograms contributes to its superior arrival picking abilities compared to the smaller model.

Chai, Chengping [Oak Ridge National Laboratory (OR↗

White light modeling, algorithm development, and validation on the micro-arcsecond metrology testbed

The Space Interferometry Mission (SIM), scheduled for launch in early 2010, is an optical interferometer that will perform narrow angle and global wide angle astrometry with unprecedented accuracy, providing differential position accuracies of 1uas, and 4uas global accuracies in position, proper motion and parallax. SIM astrometric measurements are synthesized from pathlength delay measurements provided by three Michelson-type, white light interferometers. Two of the interferometers are used for making precise measurements of variations in the spacecraft attitude, while the third interferometer performs the science measurement. The ultimate performance of SIM relies on a combination of precise fringe measurements of the interfered starlight with picometer class relative distance measurements made between a set of fiducials that define the interferometer baseline vectors. The focus of the present paper is on the development and analysis of algorithms for accurate white light fringe estimation, and on the preliminary validation of these algorithms on the Micro-Arcsecond Testbed (MAM).

Shen, Janice TsaePyng↗

Current and future neutrino oscillation constraints on leptonic unitarity

The unitarity of the lepton mixing matrix is a critical assumption underlying the standard neutrino-mixing paradigm. However, many models seeking to explain the as-yet-unknown origin of neutrino masses predict deviations from unitarity in the mixing of the active neutrino states. Motivated by the prospect that future experiments may provide a precise measurement of the lepton mixing matrix, we revisit current constraints on unitarity violation from oscillation measurements and project how next-generation experiments will improve our current knowledge. With the next-generation data, the normalizations of all rows and columns of the lepton mixing matrix will be constrained to ≲10% precision, with the e-row best measured at ≲1% and the τ-row worst measured at ~10% precision. The measurements of the mixing matrix elements themselves will be improved on average by a factor of 3. We highlight the complementarity of DUNE, T2HK, JUNO, and IceCube Upgrade for these improvements, as well as the importance of ντ appearance measurements and sterile neutrino searches for tests of leptonic unitarity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rotating-Coil Measurement System for Small-Bore-Diameter Magnet Characterization

Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.

42 ENGINEERING↗

Quantum nondemolition measurements of harmonic oscillators

Measuring systems to determine the real component of the complex amplitude of a harmonic oscillator are described. This amplitude is constant in the absence of driving forces, and the uncertainty principle accounts for the fact that only the real component can be measured precisely and continuously ('quantum nondemolition measurement'). Application of the measuring systems to the detection of gravitational waves is considered.

Thorne, K. S.↗

Apparatus Makes Precisely Saturated Solutions

Simple laboratory apparatus establishes equilibrium conditions of temperature and concentration in solutions for use in precise measurements of saturation conditions. With equipment typical measurement of saturation concentration of protein in solution established and measured within about 24 hours. Precisely saturated solution made by passing solvent or solution slowly along column packed with solute at precisely controlled temperature. If necessary, flow stopped for experimentally determined interval to allow equilibrium to be established in column.

Pusey, Marc L.↗

Laser Raman diagnostics in subsonic and supersonic turbulent jet diffusion flames

Ultraviolet (UV) spontaneous vibrational Raman scattering combined with laser-induced predissociative fluorescence (LIPF) is developed for temperature and multi-species concentration measurements. Simultaneous measurements of temperature, major species (H2, O2, N2, H2O), and minor species (OH) concentrations are made with a 'single' narrow band KrF excimer laser in subsonic and supersonic lifted turbulent hydrogen-air diffusion flames. The UV Raman system is calibrated with a flat-flame diffusion burner operated at several known equivalence ratios from fuel-lean to fuel-rich. Temperature measurements made by the ratio of Stokes/anti-Stokes signal and by the ideal gas law are compared. The single shot measurement precision for concentration and temperature measurement is 5 to 10 pct. Calibration constants and bandwidth factors are determined from the flat burner measurements and used in a data reduction program to arrive at temperature and species concentration measurements. These simultaneous measurements of temperature and multi-species concentrations allow a better understanding of the complex turbulence-chemistry interactions and provide information for the input and validation of CFD models.

Cheng, T. S.↗

Solar extreme ultraviolet sensor and advanced langmuir probe

For more than two decades, the staff of the Space Physics Research Laboratory (SPRL) has collaborated with the Goddard Space Flight Center (GSFC) in the design and implementation of Langmuir probes (LP). This program of probe development under the direction of Larry Brace of GSFC has evolved methodically with innovations to: improve measurement precision, increase the speed of measurement, and reduce the weight, size, power consumption and data rate of the instrument. Under contract NAG5-419 these improvements were implemented and are what characterize the Advanced Langmuir Probe (ALP). Using data from the Langmuir Probe on the Pioneer Venus Orbiter, Brace and Walter Hoegy of GSFC demonstrated a novel method of monitoring the solar extreme ultraviolet (EUV) flux. This led to the idea of developing a sensor similar to a Langmuir probe specifically designed to measure solar EUV (SEUV) that uses a similar electronics package. Under this contract, a combined instrument package of the ALP and SEUV sensor was to be designed, constructed, and laboratory tested. Finally the instrument was to be flight tested as part of sounding rocket experiment to acquire the necessary data to validate this method for possible use in future earth and planetary aeronomy missions. The primary purpose of this contract was to develop the electronics hardware and software for this instrument, since the actual sensors were suppied by GSFC. Due to budget constraints, only a flight model was constructed. These electronics were tested and calibrated in the laboratory, and then the instrument was integrated into the rocket payload at Wallops Flight Facility where it underwent environmental testing. After instrument recalibration at SPRL, the payload was reintegrated and launched from the Poker Flat Research Range near Fairbanks Alaska. The payload was successfully recovered and after refurbishment underwent further testing and developing to improve its performance for future use.

Voronka, N. R.↗

Final-Approach Spacing Aids (FASA) evaluation for terminal-area, time-based air traffic control

A jointly funded (NASA/FAA) real-time simulation study was conducted at NASA Langley Research Center to gather comparative performance data among three candidate final-approach spacing aid (FASA) display formats. Several objective measures of controller performance and their display eye-scan behavior as well as subjective workload and rating questionnaires were used. For each of two representative pattern-speed procedures (a 170-knot procedure and a 210-knot procedure with speed control aiding), data were gathered, via twelve FAA controllers, using four final-controller display format conditions (manual/ARTS 3, graphic marker, DICE countdown, and centerline slot marker). Measured runway separations were more precise with both the graphic marker and DICE countdown formats than with the centerline slot marker and both (graphic and DICE) improved precision relative to the manual/ARTS 3 format. For three separate rating criteria, the subject controllers ranked the FASA formats in the same order: graphic marker, DICE countdown, and centerline slot marker. The increased precision measured with the 210-knot pattern-speed procedure may indicate the potential for the application of speed-control aiding where higher pattern speeds are practical after the base-to-final turn. Also presented are key FASA issues, a rationale for the formats selected for testing, and their description.

Credeur, Leonard↗

Development of a Pulsed 2-micron Laser Transmitter for CO2 Sensing from Space

NASA Langley Research Center (LaRC), in collaboration with NASA Jet Propulsion Laboratory (JPL), is engaged in the development and demonstration of a highly efficient, versatile, 2-micron pulsed laser that can be used in a pulsed Differential Absorption Lidar (DIAL)/Integrated Path Differential Absorption (IPDA) instrument to make precise, high-resolution CO2 measurements to investigate sources, sinks, and fluxes of CO2. This laser transmitter will feature performance characteristics needed for an ASCENDS system that will be capable of delivering the CO2 measurement precision required by the Earth Science Decadal Survey (DS).

Singh, Upendra N.↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

Monitoring Atmospheric CO2 From Space: Challenge & Approach

Atmospheric CO2 is the key radiative forcing for the Earth's climate and may contribute a major part of the Earth's warming during the past 150 years. Advanced knowledge on the CO2 distributions and changes can lead considerable model improvements in predictions of the Earth's future climate. Large uncertainties in the predictions have been found for decades owing to limited CO2 observations. To obtain precise measurements of atmospheric CO2, certain challenges have to be overcome. For an example, global annual means of the CO2 are rather stable, but, have a very small increasing trend that is significant for multi-decadal long-term climate. At short time scales (a second to a few hours), regional and subcontinental gradients in the CO2 concentration are very small and only in an order of a few parts per million (ppm) compared to the mean atmospheric CO2 concentration of about 400 ppm, which requires atmospheric CO2 space monitoring systems with extremely high accuracy and precision (about 0.5 ppm or 0.125%) in spatiotemporal scales around 75 km and 10-s. It also requires a decadal-scale system stability. Furthermore, rapid changes in high latitude environments such as melting ice, snow and frozen soil, persistent thin cirrus clouds in Amazon and other tropical areas, and harsh weather conditions over Southern Ocean all increase difficulties in satellite atmospheric CO2 observations. Space lidar approaches using Integrated Path Differential Absorption (IPDA) technique are considered to be capable of obtaining precise CO2 measurements and, thus, have been proposed by various studies including the 2007 Decadal Survey (DS) of the U.S. National Research Council. This study considers to use the Intensity-Modulated Continuous-Wave (IM-CW) lidar to monitor global atmospheric CO2 distribution and variability from space. Development and demonstration of space lidar for atmospheric CO2 measurements have been made through joint adventure of NASA Langley Research Center and Exelis, Inc. As prototype space IPDA lidars, airborne laser absorption lidar systems operating in 1.57 CO2 absorption band have been developed and tested through lab, ground-based range, and flight campaigns. Very encouraging results have been obtained. The signal-to-noise ratio (SNR) for clear sky IPDA measurements of CO2 differential absorption optical depth (DAOD) for a 10-s integration over vegetated areas with about 10 km range was found to be as high as 1300, resulting in an error 0.077% or equivalent CO2 mixing ratio (XCO2) column precision of ~0.3 ppm. Precise range measurements using the IM-CW lidar approach were also achieved, and the uncertainties have been shown to be at sub meter level. Based on the airborne lidar development, space lidar and atmospheric CO2 observations are simulated. It shows that with the IM-CW approach, accurate atmospheric CO2 measurements can be achieved from space, and a space mission such as that proposed by the DS will meet science goals of atmospheric CO2 monitoring.

Lin, Bing↗

The TAMUTRAP facility: A Penning trap facility at Texas A&M University for weak interaction studies

The Texas A&M University Penning Trap (TAMUTRAP) facility aims to test the standard model of the electroweak interaction by measuring the β-ν correlation parameter, a βν , for β-delayed proton emitters in the atomic mass range 20 < A < 40. Precision measurements of this correlation parameter and, inextricably, the Fierz interference parameter, are a sensitive probe of physics beyond the standard model. Here, using off-line ion sources, the TAMUTRAP facility has been commissioned by demonstrating the ability to manipulate the trapped-ion motions as well as to perform precision mass measurements. Our novel cylindrical Penning trap – the world's largest – differs from typical designs in two key aspects: the electrode structure has an 180-mm inner diameter and an overall length of 334.89 mm leading to a uniquely small length/radius ratio l/r = 3.72; and we do not use the long end cap approximation, instead our short endcap electrodes are closed and capable of being placed at an arbitrary potential. This geometry is optimized for observing β-delayed proton decays, but is also well suited for other in-trap and post-trap precision decay experiments. In addition to presenting an overview of the TAMUTRAP facility, we demonstrate that our unique Penning trap is able to measure masses with a precision similar to typical trap designs.

47 OTHER INSTRUMENTATION↗

Measuring Loss Tangents of Substrates for Superconducting Qubits with Part-per-Billion Precision

We report precision measurements of dielectric loss tangents in substrates for superconducting qubits using an ultra-high quality factor niobium SRF cavity operating at millikelvin temperatures and low electric fields. Multiple substrate types and surface treatments are compared to assess how processing impacts microwave dissipation. The RF results are correlated with materials analysis, including ToF-SIMS and XPS, to identify dominant loss mechanisms. This combined study links microscopic surface chemistry to macroscopic performance and provides a framework for materials-driven improvements in qubit coherence and device design.

Bafia, Daniel [Fermilab]↗

Measuring Loss Tangents of Substrates for Superconducting Qubits with Part-per-Billion Precision

We report precision measurements of dielectric loss tangents in substrates for superconducting qubits using an ultra-high quality factor niobium SRF cavity operating at millikelvin temperatures and low electric fields. Multiple substrate types and surface treatments are compared to assess how processing impacts microwave dissipation. The RF results are correlated with materials analysis, including ToF-SIMS and XPS, to identify dominant loss mechanisms. This combined study links microscopic surface chemistry to macroscopic performance and provides a framework for materials-driven improvements in qubit coherence and device design.

Bafia, Daniel [Fermilab]↗

Ultrahigh-precision Compton polarimetry at 2 GeV

Here we report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A precision of dP/P = 0.36% was achieved detecting the back-scattered photons from the Compton scattering process. This is the highest precision in a measurement of electron beam polarization using Compton scattering ever reported, surpassing the ground-breaking measurement from the SLD Compton polarimeter. Such precision reaches the level required for the future flagship measurements to be made by the MOLLER and SoLID Experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗