Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plenum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

Goekcen, Tahir↗

Update on the NASA Glenn Propulsion Systems Lab Icing and Ice Crystal Cloud Characterization (2017)

NASA Glenn's Propulsion Systems Lab, an altitude engine test facility, generates icing clouds with a spray system. While the spray system is used mostly to create ice crystal clouds (Appendix D/P), the 2017 cloud characterization effort added the requirement to produce exactly supercooled liquid clouds in Appendix C and Appendix O. Success was demonstrated to supercool the largest drops at the warmest conditions, but not freeze out the smallest drops at the coldest conditions. This paper documents primarily the total water content characterization methodology and results from an Iso-Kinetic Probe in ice crystals and Multi-Wire sensor in supercooled liquid, along with the cloud uniformity provided by light extinction tomography. Particle size distribution results from High Speed Imaging probes and a Phase Doppler Interferometer are discussed. Also, a new numerical model for tracking the thermodynamics of the air-drop interactions in PSL from the plenum toward the cloud characterization plane are noted. Both of these latter topic are more fully documented in companion papers.

Calibration↗

11-by 11-Foot Transonic Leg of the Unitary Plan Wind Tunnel (UPWT) CAD Model

A ProEngineer CAD model of the 11 Unitary Plan wind tunnel test section, diffuser inlet, plenum chamber, strut and aft diffuser has been created for use with analysis tools such as Cart3D and Star CCM+. Separate parts of the tunnel are created as parts files and assembled in an assembly file. Two merged solid parts are used for meshing. This report describes each of the parts files and features of the merged models.

computational analysis↗

Validation of Heat Transfer Correlations in Line Chill-Down Tests of Cryogenic Fluid in SINDA/FLUINT

Line chill-down is an important process in cryogenic tank propellant management, storage, and usage Complex flow dynamics during these processes: boiling heat transfer (film, transition, and nucleate) Understanding boiling phenomena can lead to efficient line chill-down systems that use less propellant, propellant stored, reducing cost for space missions Line Chill-down heat transfer was modelled using SINDA/FLUINT version 5.8 (SF) Multiple chill-down tests were modelled using: heat transfer correlations readily available in SF using HTN/HTC TIES heat transfer empiricisms developed by the University of Florida (UF) based on a series of liquid nitrogen chill-down tests using SF HTU TIES Chill-down tests modelled: liquid nitrogen tests conducted by the University of Florida horizontal flow, upward flow, and downward flow (Reynolds Numbers ranging 850-231,000)liquid hydrogen tests conducted by NASA Glenn Research Center vertical upward flow (Reynolds Number range of 18,400 - 433,000)The flow rate was measured far downstream of the test section, near the system exit. Where to set the flow rate? SF was highly sensitive, and sometime unstable, setting the test flow rate downstream (the outlet) of the test section model and setting the test pressure upstream (the inlet) of the test section model higher flow rate oscillations at the entrance of the model's test section SF was more stable setting the test flow rate upstream (than the downstream flow rate set case)test pressure was used as an inlet (SF plenum) to set the thermodynamic state (temperature and quality) coming into the system setting the appropriate downstream pressure was the unknown. The pressure drops predicted by SF for the downstream set flow rate boundary condition were much smaller than test section measured pressure drops. The multiphase pressure drop correlations used internally in SF may need to be adjusted. Models with an upstream flow rate set assumed a pressure drop that was small

cryogenic modeling↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

CFD↗

Comparative Analysis of Two Cryogenic Force Balance Calibration Systems

Cryogenic wind-tunnel facilities face unique challenges in the calibration and operation of various measurement systems and instrumentation. Instruments that are subjected to the cryogenic conditions of the test plenum require careful design and calibration procedures to maintain instrument performance. NASA’s National Transonic Facility (NTF) and the European Transonic Windtunnel (ETW) are two cryogenic wind-tunnel facilities, each with the ability to calibrate force measurement systems (FMS) at cryogenic conditions. These facilities have different methodologies and processes for calibrating these systems. This paper discusses differences in the methodologies and processes and compares the results of two separate cryogenic calibrations of the NTF-118A force balance that were completed at both wind-tunnel facilities.

Toro, Kenneth G.↗

Simulation of Hydrogen Flow in a Nuclear-Thermal Propulsion Reactor Subsystem: Conjugate Heat Transfer in Surrogate Fuel Elements and Flow Through the Dome Inlet to the Fuel Elements

NASA is performing research related to a Nuclear-Thermal Propulsion (NTP) engine as a step toward future manned missions to Mars. BWX Technologies (BWXT), in conjunction with NASA, is developing the reactor subsystem for that NTP engine design. As a subset of the reactor subsystem, the fuel elements have continued to evolve in design, as well. A set of experiments within the Nuclear Thermal Reactor Element Environmental Simulator at NASA Marshall has been developed to compliment that design process, including a series of surrogate fuel elements. Before the experiments of each surrogate can be completed, they must be deemed safe using structural analysis, which itself requires thermal and conjugate heat transfer analyses of the articles. Therefore, conjugate heat transfer simulations of the hydrogen flow through the test article fuel element surrogates were developed to provide estimates of heating, as well as to provide assessments of the fluid flow through the elements. The set of simulations involved not only the separate test conditions, but also a sensitivity study to estimate the effect of physical parameter uncertainty on the selected quantities of interest. Additionally, the fluid flow through the fore section inner plenum dome to the entrances of the fuel elements, another section of the reactor subsystem still under active development, was simulated and analyzed. The simulations show the extent of non-uniformity in the mass flow distribution across the dome outlets. Furthermore, additional analyses estimate the effects of required flow blockages on the potential development of flow dynamics. These analyses were used in the design cycle to make improvements to the reactor subsystem design.

Kalen E. Braman↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 10.16-cm iso-q and 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Numerical Simulation of the High-Speed Leg of the National Transonic Facility

Numerical simulations for the flow inside the high-speed leg of the National Transonic Facility was conducted. The NASA Tetrahedral Unstructured Software System (TetrUSS) with its USM3D_ME solver was used to perform the numerical simulations. USM3D_ME is developed and maintained by NASA Langley Research Center. Simulations were conducted for three configurations: empty tunnel, body of revolution installed, and NASA Common Research Model installed in the test section. Simulations were performed for a test section Mach number of 0.7 and 0.85 and a corresponding Reynolds number of 8 million per ft. A controller was developed that automated dynamic outflow boundary and streamlined the process of running multiple simulations. The use of a dynamic outflow boundary was the key parameter to drive simulation to the desired tunnel conditions. The numerical simulations captured expected flow features in NTF test section and in the tunnel plenum. The simulations depicted that separation of the flow inside the diffuser appears to be asymmetric and more extensive toward the top and bottom walls. Analysis of the flow field were conducted, and the computed drag coefficient compared to wind tunnel data.

NTF↗

Effect of Plasma Sheaths on Earth Re-entry MHD Processes

The first study of the full coupling between the aerothermodynamics, the magnetohydrodynamics, and the plasma sheaths within earth entry flows is here per-formed. The problem tackled herein is representative of a force-generating MHD patch located between the plenum and the frustum of a capsule entering the earth’s atmosphere at Mach 34. The reactions are obtained from a modified 11-species Park chemical solver. The physical model fully couples the drift-diffusion model for the sheaths to the multispecies Navier-Stokes equations for the plasma flow. The Hall and ion slip effects are taken into consideration within the plasma flow and within the sheaths. Results obtained indicate that the cathode sheath can exert significant resistance to current flow and thus reduce the MHD-generated force by 40% or more. The effect of the sheath on the MHD force is found to be more pronounced at lower applied magnetic field.

Earth Re-entry↗

Effect of Water Droplets Crossing the Boundary Layer in a Stagnation Point Configuration

An experimental study was conducted in the Vertical Icing Studies Tunnel at the Icing Physics Flow Laboratory of NASA Glenn Research Center to study the effect of water droplets crossing the boundary layer in a stagnation point configuration. The objective of the experiment was to determine if water droplets crossing a boundary layer create turbulent spots that accelerate the boundary layer transition from laminar to turbulent. Water droplets that crossed the boundary layer were generated with a nozzle installed in the plenum. The turbulence level in the boundary layer was measured with a hot wire system when the nozzle was off, air on, and air and water on. The results indicate that the presence of the nozzle alone did not affect the boundary layer. The activation of the nozzle to eject air only or to generate water droplets affected the turbulence level in the boundary layer. The continued study of this effect is needed because of its implications in the development of heat transfer models for icing codes.

Icing↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

Effect of Plasma Sheaths on Earth Re-entry MHD Processes

The first study of the full coupling between the aerothermodynamics, the magnetohydrodynamics, and the plasma sheaths within earth entry flows is here per-formed. The problem tackled herein is representative of a force-generating MHD patch located between the plenum and the frustum of a capsule entering the earth’s atmosphere at Mach 34. The reactions are obtained from a modified 11-species Park chemical solver. The physical model fully couples the drift-diffusion model for the sheaths to the multispecies Navier-Stokes equations for the plasma flow. The Hall and ion slip effects are taken into consideration within the plasma flow and within the sheaths. The effect of the electrode material on the MHD process is studied. Using thoriated tungsten instead of graphite leads to a four-fold increase in the Lorentz forces and also leads to significantly reduced heat fluxes on the cathode. This is attributed to the much higher electrical conductivity of the thoriated tungsten sheath reducing by orders of magnitude the plasma electrical resistance near the surfaces.

Bernard Parent↗

Detailed Velocity, Temperature, and Heat Flux Measurements on a Large Scale Film Cooling Model

To investigate the flow physics of turbine film cooling, detailed mean and fluctuating velocity and temperature surveys were made in the turbulent jet flow field behind a row of large scale film cooling holes. Additionally, surface heat transfer, film effectiveness, and turbulent heat flux values were determined. Measurements were made in the NASA Engine Research Building (ERB) SW-6 test facility, which consists of an 8.15-in2 open-inlet wind tunnel with a temperature-controlled secondary flow system. The film-cooling test plate fit into the wind tunnel such that the heat transfer surface formed the wind tunnel floor. This plate consisted of a three-hole array of film cooling holes that were fed from a plenum of different temperature.

Fluid Mechanics↗

Development and Assessment of a New Particle Image Velocimetry System in the NASA GRC 225 cm2 Wind Tunnel

As part of an ongoing campaign to provide detailed and thorough measurements in a two-dimensional impinging shock-wave/boundary-layer interaction (SWBLI), a custom implementation of the Particle Image Velocimetry (PIV) measurement technique in the NASA Glenn 225 cm2 Wind Tunnel was constructed. The flow seeding apparatus was devised to locally seed the region of interest in the overall flowfield to avoid coating the viewing window with seed material. The ability of the PIV system to provide small particles which faithfully track the underlying gas-phase flowfield was of key importance for the success of this system to make quality measurements in the SWBLI flowfield. In order to optimize and assess the performance of the particle seeding system, PIV measurements were made across a planar oblique shock wave and particle response was analyzed to quantify the particle lag effects due to the finite inertia of the seed droplets. Video recordings from a camera placed in the wind tunnel plenum tank were also used to discern the near-field behavior of the seeded plume and guide the design evolution of the seeding apparatus. The resulting optimized seeding configuration was applied to make PIV measurements in the wind tunnel test section boundary layer to assess the seed particle spatial coverage and concentration. This sample boundary layer dataset provides an analog to the eventual boundary layer measurements to be made in the axisymmetric test section under much more challenged viewing conditions.

PIV↗

Development and Assessment of a New Particle Image Velocimetry System in the NASA GRC 225 cm2 Wind Tunnel

As part of an ongoing campaign to provide detailed and thorough measurements in a two-dimensional impinging shock-wave/boundary-layer interaction (SWBLI), a custom implementation of the Particle Image Velocimetry (PIV) measurement technique in the NASA Glenn 225 cm2 Wind Tunnel was constructed. The flow seeding apparatus was devised to locally seed the region of interest in the overall flowfield to avoid coating the viewing window with seed material. The ability of the PIV system to provide small particles which faithfully track the underlying gas-phase flowfield was of key importance for the success of this system to make quality measurements in the SWBLI flowfield. In order to optimize and assess the performance of the particle seeding system, PIV measurements were made across a planar oblique shock wave and particle response was analyzed to quantify the particle lag effects due to the finite inertia of the seed droplets. Video recordings from a camera placed in the wind tunnel plenum tank were also used to discern the near-field behavior of the seeded plume and guide the design evolution of the seeding apparatus. The resulting optimized seeding configuration was applied to make PIV measurements in the wind tunnel test section boundary layer to assess the seed particle spatial coverage and concentration. This sample boundary layer dataset provides an analog to the eventual boundary layer measurements to be made in the axisymmetric test section under much more challenged viewing conditions.

PIV↗

Measurements of Temperature and Enthalpy in NASA Ames 60-MW Arcjet using Atomic Oxygen and Atomic Nitrogen Absorption

We report on measurements of temperature and enthalpy in the 60-MW Interaction Heating Facility (IHF) Arcjet at the NASA Ames Research Center. These quantities were measured at sub-second temporal resolution using tunable diode laser absorption spectroscopy, employing four Distributed Feedback (DFB) lasers to simultaneously probe the arcjet flow. Optical access was achieved through a specially-designed optical disk mounted in series with the modules of the arc heater in the add-air plenum of the column, which is positioned between the downstream electrodes and the nozzle. Gas at this measurement location serves as the reservoir condition for the ensuing supersonic expansion. Conditions in the reservoir are extreme, with temperatures between 5000-8000 K and pressures between 1-9 atm. Absorption from the 5S state of atomic oxygen at 777.2 nm and the 4P state of atomic nitrogen at 868.0 nm, two electronically-excited quantum states, formed the basis of the flow characterization measurements. Fiber-coupled laser light was pitched through the IHF via 1/8" ports in the optical disks, permitting optical access with minimal intrusion to the flow. Data was collected at 3 nominal conditions, a Low condition (1600 A, 2000 V, 0.13 kg/s), a Medium condition (3500 A, 5700 V, 0.61 kg/s), and a High condition (5900 A, 6800 V, 0.84 kg/s). Measurements suggest agreement within 1-2% between excited oxygen and excited nitrogen thermometry, indicating approximate thermal and chemical equilibration of the arcjet reservoir state, a result in keeping with long-standing assumptions of CFD modelling. Spatial gradients are found in the flow due to enthalpy loss to the facility walls, but the measured spatial non-uniformities are consistent with axi-symmetry. Measurements of specific enthalpy in the reservoir are also made utilizing excited oxygen and excited nitrogen absorption under the assumption of chemical equilibration.

Peter M. Finch↗

Lessons Learned From Designing and Building Low Organic Outgassing Cleanrooms for NASA OSIRIS-REx and Hayabusa2 Curation Facility

NASA Johnson Space Center Astromaterials Acquisition and Curation Office completed construction and commissioning of the OSIRIS-REx and Hayabusa2 cleanroom laboratory suites along with new precision cleaning and advanced curation laboratories consisting of ISO Class 5, 6, and 7 cleanrooms. The new curation facilities are designed for initial receiving, basic characterization, curation processing, and preliminary examination of carbonaceous asteroidal material. The facilities are also designed to enable long-term pristine sample storage to preserve the scientific integrity of each sample to enable future research by the international science community. The scientific study of organics is critical for both missions. The OSIRIS-REx mission instituted a stringent contamination control plan for low organics. Given these mission requirements and long-term storage preservation requirements, cleanroom construction materials were carefully selected to not hinder the scientific search for amino acids and the study of organics in the samples. Cleanroom candidate construction materials were researched for the HVAC system, floors, walls, ceiling, and plenum areas. The team chose several candidate materials that were further tested for their specific outgassing characteristics using ASTM E-595 per ASTM E-2312. The information gained provided the foundation for the final design selection of the cleanroom materials. While material selection is important before and during the facility design phase, the construction phase is where these choices are implemented by the prime construction contractor through final product and material submittals. These submittals are the last check point and changes are often submitted due to engineering/construction conflicts, especially when renovating an existing building. Any new material or equipment/product change must be identified and scrutinized for low particulate shedding and outgassing properties. In some cases, quick testing of new material is required, and compromises must be made in real-time. Careful selection and implementation of cleanroom materials significantly reduced organic and inorganic contamination beyond normal cleanroom baselines.

astromaterials curation↗