Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D, Real-time Label-free Visualization of Cellular Health

This work directly addresses a key question raised in TA7, Topic L1 of HDTRA1-16-24-FRCWMDCall, “Can quantum level changes be detected, mapped, and understood in the biological environment to allow faster diagnostic responses?” This work will use the inherently sensitive quantum property of a molecular excited state lifetime to visualize and map discrete, subtle nanometer-scale changes (e.g. NADPH vs NADH) that are key indicators of cellular health in response to chemical and biological threats and MCMs. It will also develop and exploit new, fast imaging light-sheet methods to allow faster diagnostic responses. This new imaging system will exploit time-correlated single photon counting and new advances in single-objective light-sheet microscopy (oblique plane microscopy) for fast, quantitative analysis of cellular redox state. We will add an entirely new dimension (excited state fluorescence lifetime) to oblique plane microscopy—a method that even without this added dimension was labeled by Nature Methods in 2021 as a ‘Method to Watch.’ Following instrument development and validation, we will explore cellular response to Burkholderia infections and antibiotic treatment in immortal cell lines followed by expansion to more realistic cellular environments (such as neuro-muscular junctions, NMJs) to test nerve agent simulants and their MCMs. As a microscopy platform, these methods hold the promise of being able to visualize a single infected cell (or a cellular compartment) and MCM treatment well before a larger and later organ/organism response.

47 OTHER INSTRUMENTATION↗

Splitting photons: Singlet fission in nanocrystal-molecule hybrid structures

The goal of this research is to enable all the energy contained in sunlight to be harvested by making full use of the energy contained in the blue and green wavelengths of light. Current systems are unable to extract all of the energy available from photons in this wavelength range due to rapid relaxation processes that dissipate a fraction of the energy as heat. In this work, inexpensive, earth-abundant components capable of supporting multi-excitonic processes involving more than one tightly bound excited state are investigated as a way to exceed the Shockley-Queisser limit. This research will examine hybrid organic-inorganic nanostructures capable of singlet fission, a process by which one high-energy spin-singlet state is converted into two lower-energy spin-triplet states, and subsequent triplet exciton transfer. Specifically, the organic molecules diphenylhexatriene and tetracene that maximally absorb blue light and are known to exhibit singlet fission will be bound to lead chalcogenide nanocrystals. A variety of steady-state and time-resolved spectroscopic techniques will be used to study the transfer of energy from spin-triplet excitons that are created in the organic molecules to the nanoparticle acceptors. The hybrid nanostructures here will be fully characterized both in solution or thin film via electronic absorption and photoluminescence spectroscopy, nuclear magnetic resonance spectroscopy, high-resolution mass spectrometry, transmission electron microscopy, photoelectron spectroscopy, time correlated single photon counting and transient absorption experiments. The effect of molecular and nanocrystal structure on the electronic coupling between the hybrid components will be examined to establish fundamental relationships between structure and triplet energy transfer efficiency. The findings will be directly applicable to a potential tetracene-silicon platform that may ultimately enhance the power conversion efficiency of silicon solar cells.

30 DIRECT ENERGY CONVERSION↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80- channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, opensource pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector Tilt Considerations in Bragg Coherent Diffraction Imaging: A Simulation Study

This paper addresses the three-dimensional signal distortion and image reconstruction issues in X-ray Bragg coherent diffraction imaging (BCDI) in the event of a general non-orthogonal orientation of the area detector with respect to the diffracted beam. Growing interest in novel BCDI adaptations at fourth-generation synchrotron light sources has necessitated improvisations in the experimental configuration and the subsequent data analysis. One such possibly unavoidable improvisation that is envisioned in this paper is a photon-counting area detector whose face is tilted away from the perpendicular to the Bragg-diffracted beam during the acquisition of the coherent diffraction signal. We describe a likely circumstance in which one would require such a detector configuration, along with the experimental precedent at third-generation synchrotrons. Using physically accurate diffraction simulations from synthetic scatterers in the presence of such tilted detectors, we analyze the general nature of the observed signal distortion qualitatively and quantitatively and provide a prescription to correct for it during image reconstruction. Our simulations and reconstructions are based on an adaptation of the known theory of BCDI sampling geometry, as well as the recently developed projection-based methods of wavefield propagation. Such configurational modifications and their numerical remedies are potentially valuable in realizing unconventional coherent diffraction measurement geometries, eventually paving the way for the integration of BCDI into new material characterization experiments at next-generation light sources.

36 MATERIALS SCIENCE↗

First Results from the Thomson Scattering Diagnostic on the Large Plasma Device

We present the first Thomson scattering measurements of electron density and temperature in the Large Plasma Device (LAPD), a 22 m long magnetized linear plasma device at the University of California Los Angeles (UCLA). The diagnostic spectrally resolves the Doppler shift imparted on light from a frequency-doubled Nd:YAG laser when scattered by plasma electrons. A fiber array coupled to a triple-grating spectrometer is used to obtain high stray light rejection and discriminate the faint scattering signal from a much larger background. In the center of the plasma column, the measured electron density and temperature are about ne≈1.5×1013 cm−3 and Te≈ 3 eV, respectively, depending on the discharge parameters and in good agreement with Langmuir probe data. Optical design considerations to maximize photon count while minimizing alignment sensitivity are discussed in detail and compared to numerical calculations. Raman scattering off of a quartz crystal probe is used for an absolute irradiance calibration of the system.

Kaloyan, Marietta (ORCID:0000000182593038)↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80-channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, open-source pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Extending water vapor measurement capability of photon-limited differential absorption lidars through simultaneous denoising and inversion

Abstract. The micropulse differential absorption lidar (MPD) was developed at Montana State University (MSU) and the National Center for Atmospheric Research (NCAR) to perform range-resolved water vapor (WV) measurements using low-power lasers and photon-counting detectors. The MPD has proven to produce accurate WV measurements up to 6 km altitude. However, the MPD's ability to produce accurate higher-altitude WV measurements is impeded by the current standard differential absorption lidar (DIAL) retrieval methods. These methods are built upon a fundamental methodology that algebraically solves for the WV using the MPD forward models and noisy observations, which exacerbates any random noise in the lidar observations. The work in this paper introduces the adapted Poisson total variation (PTV) specifically for the MPD instrument. PTV was originally developed for a ground-based high spectral resolution lidar, and this paper reports on the adaptations that were required in order to apply PTV on MPD WV observations. The adapted PTV method, coined PTV-MPD, extends the maximum altitude of the MPD from 6 to 8 km and substantially increases the accuracy of the WV retrievals starting above 2 km. PTV-MPD achieves the improvement by simultaneously denoising the MPD noisy observations and inferring the WV by separating the random noise from the non-random WV. An analysis with 130 radiosonde (RS) comparisons shows that the relative root-mean-square difference (RRMSE) of WV measurements between RS and PTV-MPD exceeds 100 % between 6 and 8 km, whereas the RRMSE between RS and the standard method exceeds 100 % near 3 km. In addition, we show that by employing PTV-MPD, the MPD is able to extend its useful range of WV estimates beyond that of the ARM Southern Great Plains Raman lidar (RRMSE exceeding 100 % between 3 and 4 km); the Raman lidar has a power-aperture product 500 times greater than that of the MPD.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of some wide dynamic range readout systems for photoelectric integrating spectrometers

Five types of electronic circuits commonly used for readout of currents from photomultiplier tubes were evaluated. This evaluation was conducted to define the experimental limits of achieving the widest possible dynamic range of light detection and concentration measurements in spectrochemical analysis. The circuits evaluated included the photon-counting technique and four dc circuits. These circuits displayed a dynamic range from 3 to about 4.5 decades within a repeatability criterion of 1 percent, or better. The maximum dynamic range allowed by the photomultiplier tube in this application was estimated to be about 6 decades.

Franklin, M. L.↗

Requirements for laser radar detection of a barium ion cloud at five earth radii.

The requirements for a tuned laser radar capable of detecting and ranging a high altitude barium ion cloud release are discussed. A high energy pulsed dye laser tuned to the 455.4 nm Ba II resonance line is considered as the transmitter. Photon counting detection is employed and the resultant signal is integrated over a number of successive laser firings. The solar induced radiance of the cloud is the major background noise source. Detection and ranging may be achieved with signal-to-noise ratios of the order of unity using currently available equipment. This technique has the potential of improved resolution as compared to photographic measurements previously made.

Mumola, P. B.↗

Spectrophotometric results from the Copernicus satellite. I - Instrumentation and performance.

The Princeton telescope-spectrometer on the OAO spacecraft Copernicus scans stellar spectra with a resolution of about 0.05 A between 950 and 1450 A, and twice this in first order between 1650 and 3000 A. The pointing during several minutes is steady within .02 sec, and the measured photometric precision in the shorter wavelength range is limited only by the statistics of photon counts, with 14-sec counts of about 1000 on an unreddened B1 star, m(v) = 5.0, at 1100 A. In the 1650-3000 A wavelength range, phototube noise resulting from cosmic rays makes observations difficult on stars fainter than m(v) = 3.0.

Rogerson, J. B.↗

Application of signal detection theory to optics

Basic quantum detection and estimation theory, applications to optics, photon counting, and filtering theory are studied. Recent work on the restoration of degraded optical images received at photoelectrically emissive surfaces is also reported, the data used by the method are the numbers of electrons ejected from various parts of the surface.

Helstrom, C. W.↗

Relative cross section and depolarization of NOCl

A standard photon counting technique and an argon-ion laser with 4545, 4579, 4727, 4765, 4880, 4965, 5017 and 5145-A lasing lines, providing a measurable Raman spectrum from NOCl, were used in the measurement of the Raman scattering cross section of NOCl at a Raman shift of 334.4 plus or minus 1.6/cm in relation to the N2 Raman cross section. A polarization analyzer and a quartz wedge were placed in front of the entrance slit of the double monochromator for depolarization measurements. Diagrams are plotted to show the scattering cross section and depolarization measurement results.

Hoell, J. M.↗

The Princeton equipment on board

The Princeton telescope-spectrometer on the Copernicus satellite scans stellar spectra between 950 and 1450 A in second order with a resolution of about 0.05 A. The resolution in first order, between 1650 and 3000 A, is twice that in second order. The equipment may be used down to a nominal limit of 5th magnitude with the photometric precision in second order limited only by the statistics of photon counts. At 1100 A, a rate of 1,000 per 14 sec is obtained on an unreddened B 1 star with a visual magnitude of 5.0. In the first order, phototube noise from cosmic rays limits observations to stars brighter than visual magnitude 3.0 in general.

Drake, J. F.↗