Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Pathways to IEC Standards for Heliostat Design Qualification and Site Acceptance in Central Receiver CSP Applications

This paper surveys the existing landscape of standards relevant to heliostats, identifies their gaps, and proposes a path forward to a comprehensive set of heliostat guidelines, technical specifications, and standards under the framework of International Electrotechnical Commission (IEC) TC 117. Gaps in existing guidelines and standards are surveyed using a three-tiered taxonomy: component-level, heliostat-level, and field-level. At each level, the gap analysis is followed by a proposal for a coordinated path forward on the development of standards. At the component level, advances in the understanding of wind loading should inform a technical specification for drives and structures. Reflectors require consolidation of measurement guidelines into existing standards documents. Communications & controls require technical standards to inform their selection and secure implementation. At the heliostat level, IEC 62817 (solar trackers) adequately characterizes drive systems, structures, and electronics, but requires adaptation to heliostats' use patterns, operating modes, and expected life cycles. IEC 62817 does not address heliostat beam quality and pointing accuracy, but the process for determining both is elaborated in the SolarPACES Guideline for Heliostat Performance Testing. This SolarPACES document requires two main modifications: adaptation to IEC language and inclusion of testing after heliostats which have undergone accelerated weathering and mechanical cycling (to understand performance degradation). At the field level, IEC 62862-4-2 addresses the function and control of heliostat fields but does not cover the statistically rigorous testing of heliostat groups, or field performance factors like security and soiling. The addition of documents under IEC-62862-4 is proposed to address this gap.

beam↗

Efficient and Reliable Power Takeoff for Ocean Wave Energy Harvesting

The project goal is to significantly improve the current ocean wave energy harvesting through innovative Power Take-off (PTO) design, advanced power electronics, and novel wave capture structures. The objective of the project is to design and demonstrate system-agnostic components for application across multiple MHK systems, and complete component designs, build scaled prototypes, and perform testing and analysis for metric validation of 25% increase in component rating/per unit cost and 50% reduction in failure rate. The major innovation of the PTO is the Mechanical Motion Rectifier (MMR) mechanism that rectifies the bi-directional oscillatory motion of the input from waves into a steady unidirectional rotation output to directly drive the electrical generator. Through this mechanism, the efficiency and the fatigue life of the PTO can be significantly improved to benefit the energy absorption and lifespan of the wave energy converters (WEC). During the period of performance, the component and system design are completed, the scaled prototypes are developed and performed testing. It is validated that the 25% increase in a component rating/per unit cost. The 50% reduction in failure rate is not directly validated by experiments, however, it can be explained qualitatively with analysis. Besides, 8 journal articles, 13 conference proceedings, 1 patent, 3 Master thesis and two Ph.D. dissertations are published based on the work related to this project. The list of all the publications can be found at the end of the project as an appendix. Over 30 students and postdocs were trained through this project. Three prototypes of 100W and 500W WECs and 10KW PTO were designed, built, and tested in ocean wave tank and using the NREL dynamometer. This project demonstrated 50-80% PTO efficiency, 90-98% power electronics efficiency, up to 66% capture width ratio in irregular waves, and 34% overall efficiency in regular waves.

16 TIDAL AND WAVE POWER↗

Container Evaluation: Analysis of the Swagelok Knuckle with Viewport as an Approved Hermetically Sealed Inner Container

This report outlines the results from the water ingress test, helium leak test and additional atmosphere testing for the Swagelok knuckle with viewport container further referred to as the SKV. This container is constructed from a standard union vacuum fitting, 1.33” conflat to 0.5” male VCR, a 1.33” conflat fused silica lensed viewport fitting, and a 0.5 inch VCR cap. The primary intended use of this container is to store Pu metal samples in the vault for a time interval exceeding 40 years. The samples need to be contained in an air free environment to ensure that the material does not oxidize over time. The container viewport is a critical design feature that will help the operators visually inspect and evaluate the state of the metal samples prior to opening the container. These containers are advertised as leak tight, but experimental tests were performed to test the water resistant criteria and the gas leaking criteria set forth by the TA-55 Criticality Safety Program. The results of the water ingress test show that the container is water-tight, with no signs of water penetrating the container within the required guidelines outlined in TA55-AP-522. The preliminary He leak test performed demonstrate that the conflat window port and VCR cap are able to maintain a hermetic seal. Additionally, all containers will be He leak tested independently by the manufacturer prior to shipping to LANL. A third voluntary test was added to assess the container’s ability to hold atmosphere, with successful results indicating the container is able to hold inert atmosphere to prevent lanthanum metal oxidation. It is the conclusion of the authorsthat there is enough evidence through the test conducted and outlined within this document that the proposed container meets the definition of a water-tight container, and it is able to provide a hermetic seal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progess at RML are improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modernization of the Radiation Measurements Laboratory at the Advanced Test Reactor Complex

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The Radiation Measurements Laboratory (RML) was founded in the 1960s to support reactor operations and to conduct independent scientific research. For nearly six decades RML has performed four primary functions: monitoring of radioactivity by gamma-ray spectroscopy of routine reactor samples, fluence rate determinations for irradiation cycles, fission-rate measurements for the ATR-Critical (ATR-C) Facility, and independent research and development of radiation detection systems and applications. Through the decades, RML has seen technological advancements that have been integrated into each of the critical functions of the laboratory. However, many of the measurement and analysis systems employed to this day can be improved by modernization. Recent progress at RML is improving reliability and accuracy of the radiation measurements performed in support of nuclear energy research for the U.S.A. Department of Energy. The control and data collection systems supporting ATR-C have been upgraded. New High-Purity Germanium (HPGe) spectrometers have been procured with liquid nitrogen recycling capabilities to improve up-time and reduce measurement uncertainties. Fluence-rate measurement techniques are also being improved to ensure accuracy, avoid systemic errors, and identify biases. In a parallel effort, new scientific research avenues are being explored which will provide an opportunity to further enhance the utilization of ATR and ensure the sustainability of the RML as nuclear research continues to evolve. The RML is improving the effectiveness of irradiation services provided by ATR while ensuring a sustainable future for nuclear energy research.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The design and safe operation of experiments in ATR is aided by the operation of the ATR-Critical Facility (ATR-C), a lower-power reactor with the same size and geometry of the ATR. Short, low-power irradiations at the ATR-C are used to study the effects of control devices and test assemblies on the overall power distribution of various core loadings and to compare calculated data for reactor models. A technique was developed at INL to measure fission rates in fuel plate assembly reactors utilizing small, enriched uranium-aluminum (U-Al) alloy monitors, and to support ATR-C irradiations for forty years. Several hundred monitor wires placed throughout the reactor provide fine spatial resolution of the fission rates. A direct correlation exists between the fission rates of the U-Al monitors and the immediately adjacent reactor region. Extensive calibration was previously performed to determine the conversion factor for beta-particle activity of the irradiated U-Al monitors. The fission rate in the U-Al monitors can thus be determined by measuring the beta-particle decay of fission-products following irradiation of the monitors. The American Society for Testing and Materials (ASTM International) has established a standard practice for determining neutron fluence rate by radioactivation of depleted uranium. The ASTM standard practice also measures the concentration of fission-products in the uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of the ASTM standard practice was investigated for ATR-C irradiations and compared to the present method. The need to analyze hundreds of samples for each irradiation posed several challenges. Therefore, practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the expected sources of error for each method were investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reducing communication in algebraic multigrid with multi-step node aware communication

Algebraic multigrid (AMG) is often viewed as a scalable [Formula: see text] solver for sparse linear systems. Yet, AMG lacks parallel scalability due to increasingly large costs associated with communication, both in the initial construction of a multigrid hierarchy and in the iterative solve phase. This work introduces a parallel implementation of AMG that reduces the cost of communication, yielding improved parallel scalability. It is common in Message Passing Interface (MPI), particularly in the MPI-everywhere approach, to arrange inter-process communication, so that communication is transported regardless of the location of the send and receive processes. Performance tests show notable differences in the cost of intra- and internode communication, motivating a restructuring of communication. In this case, the communication schedule takes advantage of the less costly intra-node communication, reducing both the number and the size of internode messages. Node-centric communication extends to the range of components in both the setup and solve phase of AMG, yielding an increase in the weak and strong scaling of the entire method.

Computer Science↗

Multi-Scale Thermal Analysis for Design of SiC-Based Medium Voltage Motor Drive: Preprint

This paper describes a multi-scale thermal analysis approach for the design of an air-cooled 1.7-kV SiC MOSFET-based medium-voltage variable-speed motor drive. The National Renewable Energy Laboratory supported the project objectives by providing thermal management design support to the project partner The Ohio State University (OSU). The scope of the models and limited resources required efficient and flexible thermal models to be developed. Two modeling techniques are described that significantly reduced model run time and enabled more complex models to be run faster while retaining needed accuracy. The first technique uses the effectiveness-NTU method to extract convection boundary conditions from a computational fluid dynamics (CFD) model that can be applied to a fast-running finite element analysis model. The second is a porous media technique that enables system-level CFD simulations that incorporate effects from heat exchangers (e.g., pin fin heat sinks) that run in a fraction of the time required for fully resolved CFD simulations. The multi-scale approach to the thermal analysis enabled fast and accurate simulation for the converter design ranging from the die level up to the full system with 36 submodules. The modeling results were validated against experimental data from system tests performed by OSU.

DIRECT ENERGY CONVERSION↗

Control of Radioactive Methyl Iodide Gases by Mesoporous Hybrid Adsorbents at High Humid Condition - 19329

During the operation of nuclear facility as well as decommissioning stage, various radioactive gaseous wastes are generated. It is generally recognized that radioiodine is potentially one of the most hazardous gas on the human body and environment. Iodine-131 release in the gaseous effluents at the nuclear facilities had been a critical environmental concern. Reducing iodine release is a critical issue in radioactive waste system evaluation, especially in their adherence to the 'as low as reasonably achievable' (ALARA) criteria because radioiodine among these gaseous wastes has radiological harm. Therefore, numerous studies for the removal of radioiodine from the off-gas stream of nuclear facilities have been performed with formation processes and chemical structure. There has been some concern regarding the use of TEDA-impregnated activated carbon as an adsorbent for radioiodine removal, because of the low ignition point of TEDA and the possible release of TEDA from the charcoal in continuously flowing air streams. Therefore, the TEDA-impregnated activated carbon cannot use to trap radioiodine generated from high humid condition, due to the rapid drop of the removal efficiency. It is obvious that high humid can be expected during design basis event such as loss-of-coolant accident (LOCA). Therefore, investigation on the retention of organic radioiodine (CH3I131) by various activated carbons at high humid condition has extensively been performed so far. But there are no good results on the adsorption of methyl iodide at high humid condition up to now. As a result, the promising approach to the problem of iodine removal under high humid conditions is to use organic-inorganic hybrid adsorbents in which are enough retention characteristics from hydrophobic property. In order to develop the best removal efficiency for the control of radioiodine gas generated from a high humid process, a hydrophobic adsorbents was developed and the performance test of adsorbent using radioactive methyl iodide tracer was also performed. Demonstration test of adsorbent using radioactive methyl iodide tracer was performed at high humid conditions up to 97% relative humidity. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel defoamer for processing nuclear waste: Testing and performance

Abstract Legacy radioactive waste from nuclear weapons material processing is the biggest environmental challenge in the state of South Carolina, and one of the biggest in the United States. Although substantial progress has been made in processing and vitrifying high‐level radioactive waste at the Savannah River site, approximately 35 million gallons remains to be treated and dispositioned. In this article, we show the development of a new defoamer for use in the processing of high‐level radioactive waste. The application of the new defoamer is not only more effective at controlling foam but will shorten the batch processing time leading to safer and more efficient processing. This has the potential to help shorten the overall site mission lifetime, saving the federal government hundreds of millions of dollars. The novel aspect of the new defoamer is its effectiveness and stability in the harsh conditions needed for processing high‐level radioactive waste: high temperatures, pH 4–13, strong oxidizing and reducing agents, and numerous metal catalysts. The defoamer will replace an existing antifoam agent that decomposes to form multiple flammable gases. Because the existing antifoam agent decomposes quickly, processing changes increased processing time. Statement of novelty We demonstrate that a new defoamer has been developed for use in processing high‐level radioactive waste. This novel defoamer is effective and stable in the harsh processing conditions with no detectable flammable by‐products. Because the existing antifoam agent decomposes quickly, processing changes, including lowering acid addition rates and evaporation rates, increased processing time. The new defoamer is not only more effective at controlling foam but will shorten the batch processing time and lead to safer and more efficient processing by eliminating the production of flammable gases. Statement of industrial relevance Foaming is of great concern in many industrial processes involving three‐phase gas/liquid/fine‐solids systems, like in water evaporation, mineral floatation, air sparging in situ remediation techniques, and in those found in the paper industry.

Lambert, Dan P.↗

A compact design for an electric driven hydraulic gear machine capable of multiple quadrant operation

This paper presents an innovative design of an integrated electro-hydraulic (EH) flow generation unit able to operate in multiple quadrants. The proposed unit is composed of a hydraulic machine which can operate in either pumping or motoring mode, and an electric machine, which can operate as electric motor or generator. The adopted morphological integration of the two unit fulfills the goals of maximizing compactness, power to weight ratio, energy efficiency and quietness. Furthermore, the design results from a numerical optimization procedure that includes detailed simulation of both the electric machine and the hydraulic machine, using simulation tools previously developed by the authors, but combined for the first time in this work. After describing the optimization procedure, the paper focuses on the design integration aspects of the novel unit. A 9 kW prototype of the integrated unit was also fabricated and tested to verify its performance. Tests results show a measured overall energy efficiency up to 69%, demonstrating the potentials of the proposed concept, despite some limitations present in the first prototypes which could be addressed in future design refinements.

42 ENGINEERING↗

Molecular Level Understanding of How Oxygen and Carbon Monoxide Improve NOx Storage in Palladium/SSZ-13 Passive NOx Adsorbers: The Role of NO+ and Pd(II)(CO)(NO) Species

Addition of molecular oxygen to NO-containing stream improves NOx storage of the Pd/H-SSZ-13. Model Pd/SSZ-13 with high dispersion of Pd ions (0.1 and 1 wt% Pd) was synthesized. The material was characterized with FTIR and cryo-STEM. Adsorption of NO leads to the formation of Pd(II)-NO and Pd(I)-NO complexes as well as NO+ species that replace residual H+ (extra framework) sites. These nitrosyl species are characterized by notable thermal stability, with resistance to decomposition under high vacuum at 200 ºC. Addition of O2 to NO slightly increases the amount of Pd(II)-NO complex with ?NO at ~1865 cm-1 whereas the low frequency ?NO band at 1805 cm-1, assigned to Pd(I)-NO, decreases in intensity. Simultaneously, polydentate nitrate species appear in small amounts, contributing to the high temperature NOx release stage during a PNA cycle. The concentration of NO+ (characterized by the broad IR band centered at 2170 cm-1), in the presence of O2, increases in intensity profoundly and contributes to the increased capacity of Pd/SSZ-13 to store NOx and release it at temperatures >140 ºC. In the presence of H2O/O2, Pd/SSZ-13 does not perform satisfactorily as PNA, but the addition of CO to the stream improves the PNA storage capacity and shifts the NOx release peak temperature to >320 ºC where SCR catalysts are the most effective. With the aid of FTIR spectroscopy, we reveal the selective formation of a mixed carbonyl-nitrosyl complex Pd(II)(NO)(CO) in the presence of CO. Due to shielding of the Pd(II) ion from excess water and selective formation of stable coordinately saturated Pd(NO)(CO) complexes, the PNA performance is improved by CO. Therefore, we demonstrate that beside NO species adsorbed on Pd, nitrosyl ions (NO+) in extra framework positions of chabazite are important for PNA storage. Furthermore, the important role of CO in promoting PNA performance is elucidated, thus highlighting the utility of the combined spectroscopic approach (in addition to materials performance testing) to derive structure/PNA performance relationships and identify new avenues to improve the PNA performance.

Khivantsev, Konstantin↗

Modular Hybrid Plasma Reactor for Low Cost Bulk Production of Nanomaterials

INL developed a bench scale modular hybrid plasma system for gas phase nanomaterials synthesis. The system was being optimized for WO 3 nanoparticles production and scale model projection to a 300 kW pilot system. During the course of technology development many modifications had been done to the system to resolve technical issues that had surfaced and also to improve the performance. All project tasks had been completed except 2 optimization subtasks. These 2 subtasks, a 4-hour and an 8-hour continuous powder production runs at 1 lb/hr powder feeding rate, were unable to complete due to technical issues developed with the reactor system. The 4-hour run had been attempted twice and both times the run was terminated prematurely. The modular electrode for the plasma system was significantly redesigned to address the technical issues. Fabrication of the redesigned modular electrodes and additional components had been completed at the end of the project life. However, not enough resource was available to perform tests to evaluate the performance of the new modifications. More development work would be needed to resolve these problems prior to scaling. The technology demonstrated a surprising capability of synthesizing a single phase of meta-stable δ-Al 2 O 3 from pure α-phase large Al 2 O 3 powder. The formation of δ-Al 2 O 3 was surprising because this phase is meta-stable and only formed between 973-1073 K, and δ-Al 2 O 3 is very difficult to synthesize as a single phase. Besides the specific temperature window to form this phase, this meta-stable phase may have been stabilized by nanoparticle size formed in a high temperature plasma process. This technology may possess the capability to produce unusual meta-stable nanophase materials that would be otherwise difficult to produce by conventional methods. A 300 kW INL modular hybrid plasma pilot scale model reactor had been projected using the experimental data from PPG Industries 300 kW hot wall plasma reactor. The projected size of the INL 300 kW pilot model reactor would be about 15% that of the PPG 300 kW hot wall plasma reactor. Including the safety net factor the projected INL pilot reactor size would be 25-30% of the PPG 300 kW hot wall plasma pilot reactor. Due to the modularity of the INL plasma reactor and the energy cascading effect from the upstream plasma to the downstream plasma the energy utilization is more efficient in material processing. It is envisioning that the material through put range for the INL pilot reactor would be comparable to the PPG 300 kW pilot reactor but the energy consumption would be lower. The INL hybrid plasma technology is rather close to being optimized for scaling to a pilot system. More near term development work is still needed to complete the process optimization before pilot scaling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Optimization of Modular Hybrid Plasma Reactor

INL developed a bench–scale, modular hybrid plasma system for gas-phase nanomaterials synthesis. The system was optimized for WO 3 nanoparticle production and scale-model projection to a 300 kW pilot system. During the course of technology development, many modifications were made to the system to resolve technical issues that surfaced and also to improve performance. All project tasks were completed except two optimization subtasks. Researchers were unable to complete these two subtasks, a four-hour and an eight-hour continuous powder production run at 1 lb/hr powder-feeding rate, due to major technical issues developed with the reactor system. The 4-hour run was attempted twice, and on both occasions, the run was terminated prematurely. The termination was due to (1) heavy material condensation on the modular electrodes, which led to system operational instability, and (2) pressure buildup in the reactor due to powder clogging of the exhaust gas and product transfer line. The modular electrode for the plasma system was significantly redesigned to address the material condensation problem on the electrodes. However, the cause for product powder clogging of the exhaust gas and product transfer line led to a pressure build up in the reactor that was undetected. Fabrication of the redesigned modular electrodes and additional components was completed near the end of the project life. However, insufficient resource was available to perform tests to evaluate the performance of the new modifications. More development work would be needed to resolve these problems prior to scaling.

36 MATERIALS SCIENCE↗

Clothes Dryer Automatic Termination Evaluation

Volume 2: Improved Sensor and Control Designs Many residential clothes dryers on the market today provide automatic cycles that are intended to stop when the clothes are dry, as determined by the final remaining moisture content (RMC). However, testing of automatic termination cycles has shown that many dryers are susceptible to over-drying of loads, leading to excess energy consumption. In particular, tests performed using the DOE Test Procedure in Appendix D2 of 10 CFR 430 subpart B have shown that as much as 62% of the energy used in a cycle may be from over-drying. Volume 1 of this report shows an average of 20% excess energy from over-drying when running automatic cycles with various load compositions and dryer settings. Consequently, improving automatic termination sensors and algorithms has the potential for substantial energy savings in the U.S.

algorithm↗

Measured Performance of Residential Dehumidifiers Under Cyclic Operation

Residential construction practices are progressing toward higher levels of energy efficiency. A proven strategy to save energy is to simultaneously increase building insulation levels and reduce outdoor air infiltration. Overall, this strategy results in a shift in the mix of latent and sensible space conditioning loads, requiring proportionally more moisture to be removed compared to standard homes. In this project, researchers at the National Renewable Energy Laboratory (NREL) developed steady state performance maps to predict dehumidifier performance at a variety of indoor conditions. However, installed heating, ventilating, and air-conditioning (HVAC) equipment rarely operates at steady state. Part load performance testing of residential dehumidifiers is not mandated by current test standards. Therefore, the team tested the part load performance of four residential dehumidifiers in NREL’s Advanced HVAC Systems Laboratory . The part load efficiency of each dehumidifier was measured under 13 cycling scenarios, and combined with NREL field data to develop part load fraction (PLF) performance curves under realistic cycling scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Demonstration of Motion Correction for Ship-to-Ship Passive Inspections

Passive radiation detection is a key tool for detecting illicit nuclear materials. In maritime applications it is most effective against small vessels where attenuation is of less concern. Passive imaging provides: discrimination between localized (threat) and distributed (non-threat) sources, removal of background fluctuations due to nearby shorelines and structures, source localization to an individual craft in crowded waters, and background subtracted spectra. Unfortunately, imaging methods cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing sensitivity. This is particularly true for the smaller water craft where passive inspections are most valuable. In this project we performed tests and improved the performance of an instrument (developed earlier under, “Motion Correction for Ship-to-Ship Passive Inspections”) that uses automated tracking of a target vessel in visible-light images to generate a 3D radiation map of the target vessel from data obtained using a gamma-ray imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗