Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Heat Transfer Issues in Thin-Film Thermal Radiation Detectors

The Thermal Radiation Group at Virginia Polytechnic Institute and State University has been working closely with scientists and engineers at NASA's Langley Research Center to develop accurate analytical and numerical models suitable for designing next generation thin-film thermal radiation detectors for earth radiation budget measurement applications. The current study provides an analytical model of the notional thermal radiation detector that takes into account thermal transport phenomena, such as the contact resistance between the layers of the detector, and is suitable for use in parameter estimation. It was found that the responsivity of the detector can increase significantly due to the presence of contact resistance between the layers of the detector. Also presented is the effect of doping the thermal impedance layer of the detector with conducting particles in order to electrically link the two junctions of the detector. It was found that the responsivity and the time response of the doped detector decrease significantly in this case. The corresponding decrease of the electrical resistance of the doped thermal impedance layer is not sufficient to significantly improve the electrical performance of the detector. Finally, the "roughness effect" is shown to be unable to explain the decrease in the thermal conductivity often reported for thin-film layers.

Barry, Mamadou Y.↗

Micrometeoroid composition analyzer

Technique has been developed to detect moving charged particles and to determine their positions and/or their velocity vectors, relative to three mutually orthogonal axes, without particle impact or any elements of detector and without changing particle charge or motion.

Auer, S. O.↗

Plasma-Based Detector of Outer-Space Dust Particles

A report presents a concept for an instrument to be flown in outer space, where it would detect dust particles - especially those associated with comets. The instrument would include a flat plate that would intercept the dust particles. The anticipated spacecraft/dust-particle relative speeds are so high that the impingement of a dust particle on the plate would generate a plasma cloud. Simple electric dipole sensors located equidistantly along the circumference of the plate would detect the dust particle indirectly by detecting the plasma cloud. The location of the dust hit could be estimated from the timing of the detection pulses of the different dipoles. The mass and composition of the dust particle could be estimated from the shapes and durations of the pulses from the dipoles. In comparison with other instruments for detecting hypervelocity dust particles, the proposed instrument offers advantages of robustness, large collection area, and simplicity.

Tsurutani, Bruce↗

Neutral particle background in cosmic ray telescopes composed of silicon solid state detectors

The energy loss-spectrum of secondary charged particles produced by the interaction of gamma-rays and energetic neutrons in silicon solid state detectors has been measured with a satellite-borne cosmic ray telescope. In the satellite measurements presented here two distinct neutral background effects are identified: secondary protons and alpha particles with energies of about 2 to 100 MeV produced by neutron interactions, and secondary electrons with energies of about 0.2 to 10 MeV produced by X-ray interactions. The implications of this neutral background for satellite measurements of low energy cosmic rays are discussed, and suggestions are given for applying these results to other detector systems in order to estimate background contamination and optimize detector system design.

Mewaldt, R. A.↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗

Research in particles and fields

The astrophysical aspects of cosmic radiation and the radiation and electromagnetic field environment of the Earth and other planets are investigated. Energetic particle and photon detector systems flown on spacecraft and balloons are used. Galactic, solar, interplanetary, and planetary energetic particles and plasmas are also studied with emphasis on precision measurements with high resolution in charge, mass, and energy.

Vogt, R. E.↗

Multiple-Parameter, Low-False-Alarm Fire-Detection Systems

Fire-detection systems incorporating multiple sensors that measure multiple parameters are being developed for use in storage depots, cargo bays of ships and aircraft, and other locations not amenable to frequent, direct visual inspection. These systems are intended to improve upon conventional smoke detectors, now used in such locations, that reliably detect fires but also frequently generate false alarms: for example, conventional smoke detectors based on the blockage of light by smoke particles are also affected by dust particles and water droplets and, thus, are often susceptible to false alarms. In contrast, by utilizing multiple parameters associated with fires, i.e. not only obscuration by smoke particles but also concentrations of multiple chemical species that are commonly generated in combustion, false alarms can be significantly decreased while still detecting fires as reliably as older smoke-detector systems do. The present development includes fabrication of sensors that have, variously, micrometer- or nanometer-sized features so that such multiple sensors can be integrated into arrays that have sizes, weights, and power demands smaller than those of older macroscopic sensors. The sensors include resistors, electrochemical cells, and Schottky diodes that exhibit different sensitivities to the various airborne chemicals of interest. In a system of this type, the sensor readings are digitized and processed by advanced signal-processing hardware and software to extract such chemical indications of fires as abnormally high concentrations of CO and CO2, possibly in combination with H2 and/or hydrocarbons. The system also includes a microelectromechanical systems (MEMS)-based particle detector and classifier device to increase the reliability of measurements of chemical species and particulates. In parallel research, software for modeling the evolution of a fire within an aircraft cargo bay has been developed. The model implemented in the software can describe the concentrations of chemical species and of particulate matter as functions of time. A system of the present developmental type and a conventional fire detector were tested under both fire and false-alarm conditions in a Federal Aviation Administration cargo-compartment- testing facility. Both systems consistently detected fires. However, the conventional fire detector consistently generated false alarms, whereas the developmental system did not generate any false alarms.

Hunter, Gary W.↗

Acoustic Detection Of Loose Particles In Pressure Sensors

Particle-impact-noise-detector (PIND) apparatus used in conjunction with computer program analyzing output of apparatus to detect extraneous particles trapped in pressure sensors. PIND tester essentially shaker equipped with microphone measuring noise in pressure sensor or other object being shaken. Shaker applies controlled vibration. Output of microphone recorded and expressed in terms of voltage, yielding history of noise subsequently processed by computer program. Data taken at sampling rate sufficiently high to enable identification of all impacts of particles on sensor diaphragm and on inner surfaces of sensor cavities.

Kwok, Lloyd C.↗

Magnetic shadowing of charged particles by an extended surface

The problem of particle shadowing by the lunar surface is examined. Shadow zones are obtained analytically for small-aperture detectors on an infinite flat surface and are shown to be in good agreement with those obtained by numerical trajectory tracing. The shadow zones cover about half of all possible external field orientations for a vertical detector, which may result in serious underestimations of the frequency of observation of a particular plasma region. Shadowing may cause wide variations between observed and actual pitch angle distributions even in the case of multiple- or large-aperture detectors. Since the particle flux can be considered approximately isotropic only for magnetic fields within 35 deg of the surface normal, the electron flux to the surface may be overestimated in current balance calculations ignoring the magnetic field direction. In addition, photoelectrons may be returned to the surface by the magnetic field.

Reiff, P. H.↗

Scintillation Detector for the Measurement of Ultra-Heavy Cosmic Rays on the Super-TIGER Experiment

We discuss the design and construction of the scintillation detectors for the Super-TIGER experiment. Super-TIGER is a large-area (5.4sq m) balloon-borne experiment designed to measure the abundances of cosmic-ray nuclei between Z= 10 and Z=56. It is based on the successful TIGER experiment that flew in Antarctica in 2001 and 2003. Super-TIGER has three layers of scintillation detectors, two Cherenkov detectors and a scintillating fiber hodoscope. The scintillation detector employs four wavelength shifter bars surrounding the edges of the scintillator to collect the light from particles traversing the detector. PMTs are optically coupled at both ends of the bars for light collection. We report on laboratory performance of the scintillation counters using muons. In addition we discuss the design challenges and detector response over this broad charge range including the effect of scintilator saturation.

Link, Jason↗

The Focal Plane Assembly for the Athena X-Ray Integral Field Unit Instrument

This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off-line coincidence detection to identify and reject events caused by the in-orbit high-energy particle background. The detectors, operating at 55 mK, or less, will be thermally isolated from the instrument cryostat's 2 K stage, while shielding and filtering within the FPA will allow the instrument's sensitive sensor array to be operated in the expected environment during both on-ground testing and in-flight operation, including stray light from the cryostat environment, low-energy photons entering through the X-ray aperture, low-frequency magnetic fields, and high-frequency electric fields.

SQUID amplifier↗

Radiation Effects in CdZnTe Gamma-Ray Detectors Produced by 199 MeV Protons

Many future space missions will use Cadmium Sinc Telluride (CdZnTe) gamma-ray detectors because their operation at room temperature makes compact, lightweight detector systems possible. Even though instruments for space using CdZnTe detectors have already been built, the effect of the high-energy particle space environment on these detectors has not been measured. To determine the effect of energetic charged particles on these detectors, we have bombarded seveal CdZnTe detectors with 199 MeV protons at the Indiana University Cyclotron Facility.

radiation↗

Composition of heavy cosmic rays from 25 to 180 MeV per atomic mass unit

Relative abundances of elements from neon through zinc in the energy range from 25 to 180 MeV per amu have been determined from particle tracks in polycarbonate detectors exposed on the Apollo 16 mission. The ratios of elemental abundances of Ne + Si and 17 less than Z less than 25 to Fe + Co + Ni are found to be 5.8 plus or minus 1.9 and 2.1 plus or minus 0.7, respectively, in agreement with the results from cellulose triacetate detectors by O'Sullivan et al. (1973). These results imply that the heavy particles observed are predominantly galactic in origin. The availability to investigators of unetched plastic detectors exposed to solar-flare particles on the Apollo 16 mission is noted.

Fleischer, R. L.↗

Search by Mariner 10 for electrons and protons accelerated in association with Venus

Results of a search, with the aid of Mariner 10, for electrons and protons produced by acceleration occurring from the interaction of the solar wind and interplanetary field with the Venusian ionosphere. No evidence was found for Venus-associated particle fluxes with instrumentation capable of measuring flux variations approximately 1000 times smaller than those of the Mariner 5 detectors for charged particles, although the Mariner 10 measurements were made in the presence of an interplanetary particle flux that was extremely stable and characteristic of minimum solar activity. In addition, no evidence was obtained for electron or proton fluxes in the vicinity of the planet, nor any evidence for electron bursts in or near the observed bow shock, thus giving rise to the conclusion that Venus has no magnetosphere.-

Simpson, J. A.↗