Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Ransomware Security Threat Modeling for Photovoltaic Systems

Ransomware attacks are one of the most dangerous cyber-attacks which can disrupt the operation of photovoltaic (PV) systems and incur an enormous economic loss. This paper introduces a ransomware security threat modeling method that identifies potential vulnerabilities, threats, and impacts of ransomware attacks targeting a PV system. Here, the security threat modeling consists of three steps: 1) system identification, 2) threat modeling that finds existing vulnerabilities, 3) attack modeling that designs attack profiles to succeed ransomware attacks, and 4) penetration testing that performs authorized cyber-attacks and analyzes impacts of the ransomware attack profiles using a real-time hardware-in-the-loop (HIL) PV system security testbed.

attack modeling↗

A New Model to Determine Installed System Cost and LCOE for ARPA-E's MOSAIC Micro-Concentrator PV Program: Preprint

The US Department of Energy's Advanced Research Projects Agency-Energy (ARPA-E) started a three-year program in December 2015 called Microscale Optimized Solar-cell Arrays with Integrated Concentration (MOSAIC). It consists of 11 teams from across the United States. Its goal is to have project teams leverage expertise from conventional flat-plate photovoltaic (PV) system configuration and concentrated photovoltaic (CPV) module technology to produce a new class of modules for residential, commercial, and utility-scale markets. The intent is to increase performance and facilitate cost-effective deployment of solar power systems across a wide range of geographical locations in part by concentrating both direct and diffuse components of the sun's irradiance. This paper describes a collaboration of ARPA-E and the National Renewable Energy Laboratory (NREL) to develop a bottom-up system cost model for MOSAIC research teams. The model includes an estimate of regional, all-in, CPV installed cost, and levelized cost of energy (LCOE) by using customized inputs parameters, such as module efficiency, cost, and physical dimensions. This techno-economic cost model can help researchers analyze tradeoffs among different design parameters and then prioritize their distinct research opportunities. Moreover, it establishes a standardized cost benchmarking for MOSAIC micro-CPV systems and a normalized comparison against traditional CPV and today's highly competitive flat-plate PV systems. The model is a valuable design tool within the program, helping validate the various technical approaches and compare future deployed system competitiveness versus incumbent technologies in the PV industry.

14 SOLAR ENERGY↗

Moving Toward Quantifying Reliability - The Next Step in a Rapidly Maturing PV Industry: Preprint

Some may say that PV modules are moving toward being a simple commodity, but most major PV customers ask: 'How can I minimize chances of a module recall?' Or, 'How can I quantify the added value of a 'premium' module?' Or, 'How can I assess the value of an old PV system that I'm thinking of purchasing?' These are all questions that PVQAT (the International PV Quality Assurance Task Force) and partner organizations are working to answer. Defining standard methods for ensuring minimal acceptable quality of PV modules, differentiating modules that provide added value in the toughest of environments, and creating a process (e.g. through IECRE [1]) that can follow a PV system from design through installation and operation are tough tasks, but having standard approaches for these will increase confidence, reduce costs, and be a critical foundation of a mature PV industry. This paper summarizes current needs for new tests, some challenges for defining those tests, and some of the key efforts toward development of international standards, emphasizing that meaningful quantification of reliability (as in defining a service life prediction) must be done in the context of a specific product with design parameters defined through a quality management system.

14 SOLAR ENERGY↗

A Data-Driven Method for Estimating Behind-the-Meter Photovoltaic Generation in Hawaii

Due to the increasing penetration of distributed behind-the-meter photovoltaic (PV) systems and the installed utility revenue metering limited to monitoring only the net power import/export of the household, it is increasingly challenging for utilities to effectively plan and operate the grid. This paper proposes a methodology that estimates behind-the-meter PV generation using a selected subset of monitored PV systems. It is a data-driven approach, and the PV output is estimated utilizing a statistic regression model. A Minimum Redundancy Maximum Relevance (MRMR) algorithm is applied to preselect the optimal subset of the monitored PV systems. The performance of this approach is compared with a spatial interpolation method and a model-based approach. The proposed method is validated using high-resolution meter data recorded from 18 residential rooftop PV systems located on the island of Maui, Hawaii.

Data-driven modeling↗

Electrodynamic Dust Shield Coating Pattern for Solar Cells

The objective of this project is to work with NASA Glenn Research Center (GRC) to develop an optimized transparent Electrodynamic Dust Shield (EDS) to remove dust accumulated on a photovoltaic (PV) cell. The PV cell efficiency deterioration depend on the mass and size of dust particles. As the particle mass and size increases, the power output and efficiency of the PV system decreases. The EDS benefits PV systems by clearing dusts blocking the sun light from entering the PV cell. As of writing of this report, the KSC team have completed the optimization of EDS pattern, completed the assembly of the EDS test samples, and successfully demonstrated EDS clearing performance at one atmosphere and vacuum.

Jerry Wang↗

Using XFRACAS as a PVROM database tool.

ReliaSoft s XFRACAS is a tool chosen by Sandia National Laboratories (SNL) for the purpose of collecting and organizing photovoltaic (PV) system field data that is to be used in assessing PV system reliability. It is a Web-based, closed-loop, incident (failure) reporting, analysis, and corrective action system software package designed for the acquisition, management and analysis of quality and reliability data from multiple sources. The ability to export PV system times-to-failure and times-to-suspension for ready analysis by ReliaSoft s Weibull++ and RGA was a primary consideration in choosing XFRACAS as a reliability data collection tool.

97 MATHEMATICS AND COMPUTING↗

An Updated Life Cycle Assessment of Utility-Scale Solar Photovoltaic Systems Installed in the United States

Given the high deployment targets for solar photovoltaics (PV) needed to meet U.S. decarbonization goals, and the limited carbon budget remaining to limit global temperature rise, accurate accounting of the energy-use and greenhouse-gas emissions over the life-cycle of PV systems is needed. In the United States, most PV systems are large utility-scale systems which use single-axis trackers and central inverters, which are not commonly examined in existing life-cycle assessment (LCA) literature. In this study, we present a cradle-to-grave LCA of a typical silicon U.S. utility PV (UPV) installation which is consistent with the utility system features documented in the annual NREL PV system cost benchmark reports. We analyze and present results for four main metrics: cumulative energy demand (CED), greenhouse gas (GHG) emissions, energy payback time (EPBT), and carbon payback time (CPBT). We consider six primary manufacturing options: three based on an imported PV module supply chain (comparing low-carbon imports, high-carbon imports, and average imports), and three based on a potential domestic PV module supply chain (comparing low-carbon U.S. regions, high-carbon U.S. regions, and average U.S. regions). These manufacturing options were then paired with installation locations to create six main cases: low-carbon options were installed in Phoenix (Arizona), high-carbon options were installed in Seattle (Washington), and average options were installed in Fredonia (Kansas). These locations were selected to represent a range of irradiance and grid mixes in the United States, in order to illustrate the likely range of EPBTs and CPBTs possible across the United States. For all six cases, a sensitivity analysis for end-of-life (EOL) handling was explored to capture current and future management options: landfilling, partial recycling, and high-quality recycling. For the purposes of this report, the benchmark system was defined to use an average imported supply chain with partial recycling, installed in Fredonia (Kansas). CED results show ratios at or below 0.1 MJ oil-eq /MJgenerated which demonstrates efficient use of primary energy resources (below a 1:1 ratio), and represents a slight improvement over previous results in literature. GHG emissions per kWh range from 10-36 g CO 2 e, which are consistent with or lower than previous results published by NREL and IEA-PVPS. We use a graphical approach for calculating EPBT and CPBT in this report, which improves upon methods typically used in literature by accounting for non-linearity and avoiding data quality issues associated with long-term projections. EPBT was determined to vary from 0.5 to 1.2 years, with a benchmark EPBT of 0.6 years; CPBT was shown to vary from 0.8 to 20 years, with benchmark CPBT of 2.1 years, which is lower than other estimates from recent literature (typically >2 years).

14 SOLAR ENERGY↗

Best practices for photovoltaic performance loss rate calculations

Abstract The performance loss rate (PLR) is a vital parameter for the time-dependent assessment of photovoltaic (PV) system performance and health state. Although this metric can be calculated in a relatively straightforward manner, it is challenging to achieve accurate and reproducible results with low uncertainty. Furthermore, the temporal evolution of PV system performance is usually nonlinear, but in many cases a linear evaluation is preferred as it simplifies the assessment and it is easier to evaluate. As such, the search for a robust and reproducible calculation methodology providing reliable linear PLR values across different types of systems and conditions has been the focus of many research activities in recent years. In this paper, the determination of PV system PLR using different pipelines and approaches is critically evaluated and recommendations for best practices are given. As nonlinear PLR assessments are fairly new, there is no consent on how to calculate reliable values. Several promising nonlinear approaches have been developed recently and are presented as tools to evaluate the PV system performance in great detail. Furthermore, challenges are discussed with respect to the PLR calculation but also opportunities for differentiating individual performance losses from a generic PLR value having the potential of enabling actionable insights for maintenance.

14 SOLAR ENERGY↗

Advanced Photovoltaic Inverter Functionality using 500 kW Power Hardware-in-Loop Complete System Laboratory Testing: Preprint

With the increasing penetration of distribution connected photovoltaic (PV) systems, more and more PV developers and utilities are interested in easing future PV interconnection concerns by mitigating some of the impacts of PV integration using advanced PV inverter controls and functions. This paper describes the testing of a 500 kW PV inverter using Power Hardware-in-Loop (PHIL) testing techniques. The test setup is described and the results from testing the inverter in advanced functionality modes, not commonly used in currently interconnected PV systems, are presented. PV inverter operation under PHIL evaluation that emulated both the DC PV array connection and the AC distribution level grid connection are shown for constant power factor (PF) and constant reactive power (VAr) control modes. The evaluation of these modes was completed under varying degrees of modeled PV variability.

14 SOLAR ENERGY↗

Roadmap for photovoltaic cyber security

Cyber-secure, resilient energy is paramount to the prosperity of the United States. As the experience and sophistication of cyber adversaries grow, so too must the US power system’s defenses, situational awareness, and response and recovery strategies. Traditionally, power systems were operated with dedicated communication channels to large generators and utility-owned assets but now there is greater reliance on photovoltaic (PV) systems to provide power generation. PV systems often communicate to utilities, aggregators, and other grid operators over the public internet so the power system attack surface has significantly expanded. At the same time, solar energy systems are equipped with a range of grid-support functions, that—if controlled or programmed improperly—present a risk of power system disturbances. This document is a five-year roadmap intended to chart a path for improving cyber security for communication-enabled PV systems with clear roles and responsibilities for government, standards development organizations, PV vendors, and grid operators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Energy Impacts and Costs from PV Component Failures: Preprint

The PV Reliability Performance Model (PV-RPM) tool is used to simulate the cost and energy impacts of component faults and failures for a hypothetical PV system. This model, originally developed by Sandia National Laboratories, is a new feature in the National Renewable Energy Laboratory's System Advisor Model (SAM), which performs stochastic analysis sampling of probability distributions for faults, failures, and repairs. One PV system was created for this analysis to be representative of a portfolio of maintenance data maintained by Sandia National Laboratories. Fault, failure, and repair distributions from this system are varied from current baseline conditions to simulate different reliability and repair scenarios and resulting energy and cost impacts. Results highlight ways to express the uncertainty around PV system performance when considering the probabilistic behavior of components in the system, and ways the PV-RPM model can be used to explore different failure and repair scenarios.

14 SOLAR ENERGY↗

Heritage plaza parking lots improvement project- Solar PV installation

The Agua Caliente Band of Cahuilla Indians (ACBCI or the “Tribe”) installed a 79.95 kW solar photovoltaic (PV) system to offset the energy usage costs of the Tribal Education and Family Services offices located at the Tribe's Heritage Plaza office building, 90I Tahquitz Way, Palm Springs, CA, 92262 (the "Project"). The installation of the Solar PV system was part of the larger Heritage Plaza Parking Lot Improvements Project and mounted on the two southern carport shade structures. The solar PV system will offset 99% of the approximately 115,000 kWh in electricity delivered annually by Southern California Edison (SCE) to the Tribal Education and Family Services offices at Heritage Plaza, reducing their annual energy costs from approximately $22,000 annually to approximately $200. The total cost of the proposed solar PV system is $240,000.

14 SOLAR ENERGY↗

Photovoltaics as a terrestrial energy source. Volume 2: System value

Assumptions and techniques employed by the electric utility industry and other electricity planners to make estimates of the future value of photovoltaic (PV) systems interconnected with U.S. electric utilities were examined. Existing estimates of PV value and their interpretation and limitations are discussed. PV value is defined as the marginal private savings accruing to potential PV owners. For utility-owned PV systems, these values are shown to be the after-tax savings in conventional fuel and capacity displaced by the PV output. For non-utility-owned (distributed) systems, the utility's savings in fuel and capacity must first be translated through the electric rate structure (prices) to the potential PV system owner. Base-case estimates of the average value of PV systems to U.S. utilities are presented. The relationship of these results to the PV Program price goals and current energy policy is discussed; the usefulness of PV output quantity goals is also reviewed.

Smith, J. L.↗

Modeling Methods for Capturing System Interactions of Combined Technologies: A Study of PV + Battery

The costs of solar photovoltaics (PV) have been dropping in recent years, leading to increasing installations of solar PV systems and growing interest in how the technology will impact the electric grid at higher penetrations. Additionally, as battery costs decline it becomes important to understand the benefits and limitations of battery storage for the grid as well as potential benefits of co-locating battery storage and PV, particularly within the realm of future system planning. However, it is non-trivial to capture these potential benefits within a linearized capacity expansion model (CEM). This paper presents methodological developments to more fully represent the value and limitations of coupled PV and battery systems (PV + Battery) in CEMs using the Resource Planning Model (RPM), which co-optimizes capacity investments, transmission investments, and reduced-order dispatch in the Western Interconnection of North America through 2045. We use the model to simulate the evolution of the generation and transmission system under two core scenarios - a baseline scenario and a high renewable penetration scenario - coupled with sensitivities assuming low and midline PV and battery cost projections. When incorporating PV + battery, we find that it is important for CEMs to capture the ability of the coupled technology to provide firm capacity and reduce expected curtailment, compared to independent systems. These interactions can have even more dramatic impacts at higher solar penetrations.

14 SOLAR ENERGY↗

Detection and Diagnosis of Data Integrity Attacks in Solar Farms Based on Multilayer Long Short-Term Memory Network

Photovoltaic (PV) systems are becoming more vulnerable to cyber threats. In response to this emerging concern, developing cyber-secure power electronics converters has received increased attention from the IEEE Power Electronics Society that recently launched a cyber-physical-security initiative. Here this letter proposes a deep sequence learning based diagnosis solution for data integrity attacks on PV systems in smart grids, including dc–dc and dc–ac converters. The multilayer long short-term memory networks are used to leverage time-series electric waveform data from current and voltage sensors in PV systems. The proposed method has been evaluated in a PV smart grid benchmark model with extensive quantitative analysis. As a comparison, we have evaluated classic data-driven methods, including K-nearest neighbor, decision tree, support vector machine, artificial neural network, and convolutional neural network. Comparison results verify performances of the proposed method for detection and diagnosis of various data integrity attacks on PV systems.

42 ENGINEERING↗

Local Voltage Control in Distribution Networks: A Game-Theoretic Perspective

Inverter-based voltage regulation is gaining importance to alleviate emerging reliability and power-quality concerns related to distribution systems with high penetration of photovoltaic (PV) systems. This paper seeks contribution in the domain of reactive power compensation by establishing stability of local Volt/VAr controllers. In lieu of the approximate linear surrogate used in the existing work, the paper establishes existence and uniqueness of an equilibrium point using nonlinear AC power flow model. Key to this end is to consider a nonlinear dynamical system with non-incremental local Volt/VAr control, cast the Volt/VAr dynamics as a game, and leverage the fixed-point theorem as well as pertinent contraction mapping argument. Numerical examples are provided to complement the analytical results.

14 SOLAR ENERGY↗

Optimum Operation of Microgrid Systems that Employ PV Solar and Battery Systems

On a global scale, over 1.3 billion lack access to electricity (85% in rural areas), and approximately 2.8 billion people rely on traditional biomass for cooking. The World Health Organization estimates that household air pollution from inefficient stoves causes more premature deaths than malaria, tuberculosis, and HIV/AIDS. Increasing demand for energy has led to dramatic increases in emissions. The need for reliable electricity and limiting emissions drives research on Resilient Hybrid Energy Systems (RHESs), which provide cleaner energy by combining wind, solar, and biomass energy with traditional fossil energy, increasing production efficiency and reliability and reducing generating costs and emissions. Microgrids have been shown as an efficient means of implementing RHESs, with some focused mainly on reducing the environmental impact of electric power generation. The technical challenges of designing, implementing, and applying microgrids involve conducting a cradle-to-grave Life Cycle Analysis (LCA) to evaluate these systems’ environmental and economic performance under diverse operating conditions to evaluate resiliency. A sample RHES was developed and used to demonstrate the implementation in rural applications, where the system can provide reliable electricity for heating, cooling, lighting, and pumping clean water. The model and findings can be utilized by other regions around the globe facing similar challenges.

Nagapurkar, Prashant↗

Modelling and Optimizing CSP-PV Hybrid Systems Using the Hybrid Optimization and Performance Platform (HOPP)

The hybridization of concentrating solar power (CSP) with thermal energy storage (TES), photovoltaics (PV), and electrochemical battery energy storage systems (BESS) has the potential to provide continuous, high-capacity-factor energy production at a lower cost than a PV-BESS or CSP with TES alone. Because of the system complexity of CSP technology, it is challenging to evaluate the technological and financial performance of a CSP-PV hybrid system without detailed modeling of annual operations. To address this challenge, we have developed a modeling framework for evaluating the performance and financial viability of CSP systems hybridized with PV and BESS technologies. This modeling effort incorporates CSP tower and trough configurations into an existing modeling tool recently developed by NREL, the Hybrid Optimization and Performance Platform (HOPP). This paper provides a brief overview of our methodology, as well as an example case study. CSP with TES hybridized with PV provides the best benefit-to-cost ratio compared to the other simulated technology combinations. However, for the conditions considered, this configuration only increases the benefit-to-cost ratio by about 1% compared to the CSP with TES configuration. The PV-BESS system provides the lowest benefit-to-cost ratio compared to the other configurations explored because of the relatively low capacity credit received by the system.

Hamilton, William (ORCID:0000000244654239)↗