Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

FAIRification, Quality Assessment, and Missingness Pattern Discovery for Spatiotemporal Photovoltaic Data

The growth of the photovoltaic market has pushed the demand for power forecasting and performance evaluation for a huge population of PV power plants. Many of these power plants have spatiotemporal coherence that can be utilized for improving model accuracy. We have demonstrated in this paper the FAIRification of spatiotemporal PV time series data. Through the creation of a solar power plant ontology, we propose standards for the naming and structure of metadata used to describe the data from these power plants. Using the structure from this ontology, we have developed both R and Python packages for the automation of the FAIRification process. Going further, we have also developed an R package that automates the analysis of the quality of a data set through the designation of letter grades. To solve the issue of data missingness, we propose the use of St-GNN autoencoders to detect and impute missing values from a data set by utilizing data from power plants nearby.

14 SOLAR ENERGY↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

energy modeling↗

Validation of Silevo Modules at the Regional Test Centers (Cooperative Research and Development Final Report, CRADA Number CRD-15-589)

Silevo and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of Silevo's Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗

Validation of SolarWorld Modules at the NREL Regional Test Center Site (CRADA CRD-15-595 Final Report)

SolarWorld and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of SolarWorld’s Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗

Resilient El Rito, Microgrif System Laboratory (Village of El Rito) (Final CTAP Report)

Sandia provided technical assistance to Kit Carson Electric Cooperative (KCEC) to assess the technical merits of a proposed community resilience microgrid project in the Village of El Rito, New Mexico (NM). The project includes a proposed community resilience microgrid in the Village of El Rito, NM, around the campus of Northern New Mexico College (NNMC). A conceptual microgrid analysis plan was performed, considering a campus and community-wide approach. The analysis results provided conceptual microgrid configurations, optimized according to the performance metrics defined. The campus microgrid was studied independently and many conceptual microgrid solutions were provided that met the performance requirements. Considering the existing 1.5 MW PV system on campus far exceeds the simulated campus load peak and energy demand, a small battery installation was deemed sufficient to support the campus microgrid goals. Following the analysis and consultation, it was determined that the core Resilient El Rito team will need to further investigate the results for additional economic and environmental considerations to continue toward the best approach for their goals and needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FAIRification, Quality Assessment, and Missingness Pattern Discovery for Spatiotemporal Photovoltaic Data

The ongoing growth of the photovoltaic market has pushed the demand for power forecasting and performance evaluation for a huge population of PV power plants. Through access to a large number of time series data sets from different power plants, we have found common issues that impede the modeling process. Namely, the time series data are hard to transfer between groups due to differences in variable nomenclature, and the quality of the data sets can vary. We address the issue of variable nomenclature by FAIRifying spatiotemporal PV time series data. Through the creation of a solar power plant ontology, we propose standards for the naming and structure of metadata used to describe the data from these power plants. Using the structure from this ontology, we have developed both R and Python packages for the automation of the FAIRification process. We have also developed an R package that automates the analysis of the quality of a data set through the designation of letter grades. With access to large time series data sets across many power plants, we can utilize spatiotemporal coherence between the sites in order to improve the quality of our data. To solve the issue of data missingness, we propose the use of Spatiotemporal-GNN autoencoders to detect and impute missing values from a data set by utilizing data from power plants nearby.

14 SOLAR ENERGY↗

Cyber and Physical Security Analysis of GSI and Noventum Application for IoT Communications

We present our findings of the red team exercise conducted on the device and application developed by Guardian Sensors, Inc. (GSI) and Noventum. The app is used for situational awareness and control of photovoltaics (PV) and microgrid energy systems. The assessments performed are practical case scenarios that assess the risks and vulnerabilities posed by the app through targeted activities that could be engaged by an adversary. The assessment team’s results and recommendations are provided to inform on and mitigate the identified weaknesses to improve secure user authentication, connections, and communications. The recommendations in this report are not intended to be a security panacea but will add the desired defense-in-depth layer to securing communication of such interconnected systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frankfort 100 Solar Feasibility Study

In 2021, The city of Frankfort, Kentucky ("Frankfort," or "the City") committed to ambitious climate targets: 1. City Clean Electricity: 100% clean electricity for city government operations by the end of 2023, 2. City Clean Energy: 100% clean energy for city government operations by the end of 2030, and 3. Community Clean Energy: 100% clean energy community-wide by the end of 2040. In 2022, Frankfort partnered with the National Renewable Energy Laboratory for a Phase I study to identify pathways to achieve the City's first two goals of City Clean Electricity by 2023 and City Clean Energy by 2030 (Phase I). As recommended in the final Phase I report described (described below), NREL was asked to perform an initial feasibility study for a PV project to offset the electricity used by city government operations. This report evaluates the feasibility of utility-scale solar and identifies potential barriers.

14 SOLAR ENERGY↗

Uncertainty Quantification of Bifacial Performance Modeling

Analysis on uncertainty in the annual energy of PV systems that can be attributed to parameters of particular importance to bifacial PV modules is presented. Monte Carlo simulations are used to evaluate the effect of uncertain module bifaciality factors, module transmission fractions, albedo values, and ground clearance. The analyses cover a wide spectrum of potential PV array archetypes through variation of installation parameters. The results of the Monte Carlo analysis reveal that the uncertainty is largely dependent on albedo uncertainty, but more simulations are needed to identify trends across system archetypes. The simulations are aimed at attributing an annual energy uncertainty factor for bifacial considerations that can be applied in post-processing of project probability of exceedance analysis.

bifacial↗

PACT Data Management Plan (V.1.0)

The Perovskite PV Accelerator for Commercial Technology (PACT) is an independent validation center for the evaluation of perovskite PV technologies and their bankability. The center is led by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL) and includes as part of its team Los Alamos National Laboratory (LANL), CFV Labs, Black and Veatch (B&V), and the Electric Power Research Institute (EPRI). The goals of the center are to: Develop and improve indoor and outdoor performance characterization methods, Develop and validate accelerated qualification testing for early failures (5-10 years), Research degradation and failure modes, Validate outdoor performance, and Provide bankability services to US perovskite PV (PSC) industry. The importance of data and data management to the success and outcomes of the PACT center is paramount. This report describes how data will be managed and protected by PACT and identifies important data management principles that will guide our approach.

14 SOLAR ENERGY↗

Evaluation of Adaptive Volt-VAR to Mitigate PV Impacts [Slides]

Distributed generation (DG) sources like photovoltaic (PV) systems with advanced inverters are able to perform grid-support functions, like autonomous Volt-VAR that attempts to mitigate voltage issues by injecting or consuming reactive power. However, the Volt-VAR function operates with VAR priority, meaning real power may be curtailed to provide additional reactive power support. Since some locations on the grid may be more prone to higher voltages than others, PV systems installed at those locations may be forced to curtail more power, adversely impacting the value of that PV system. Adaptive Volt-VAR (AVV) could be implemented as an alternative, whereby the Volt-VAR reference voltage changes over time, but this functionality has not been well-explored in the literature. In this work, the potential benefits and grid impacts of AVV were investigated using yearlong quasi-static time-series (QSTS) simulations. After testing a variety of allowable AVV settings, we found that even with aggressive settings AVV resulted in <0.01% real power curtailment and significantly reduced the reactive power support required from the PV inverter compared to conventional Volt-VAR but did not provide much mitigation for extreme voltage conditions. The reactive power support provided by AVV was injected to oppose large deviations in voltage (in either direction), indicating that it could be useful for other applications like reducing voltage flicker or minimizing interactions with other voltage regulating devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Betting on Floatovoltaics: Floating PV Opportunities in the U.S.

Join NREL for a presentation on early findings on the potential for floating PV development in the U.S, covering feasible regions in the U.S., sensitivity analysis of factors affecting LCOE, operational and economic co-benefits, climate factors and early data on system performance and reliability.

14 SOLAR ENERGY↗

Resilience and economics of microgrids with PV, battery storage, and networked diesel generators

Current designs and assessments of microgrids have ignored component reliability, leading to significant errors in predicting a microgrid’s performance while islanded. Existing life cycle cost studies on hybrid microgrids—which combine photovoltaics (PV), battery storage and networked emergency diesel generators—also have not identified all the potential economic opportunities. Reducing the number of emergency diesel generators through reliance on PV and battery, retail bill savings, and demand response and wholesale market revenue streams are all important. This paper provides a new statistical methodology that calculates the impact of distributed energy reliability and variability on a microgrid’s performance and a novel use of the optimization platform REopt to explore multiple cost savings and revenue streams. We examine the impacts for microgrids in California, Maryland, and New Mexico and show that a hybrid microgrid is a more resilient and cost-effective solution than a diesel-only system. Under realistic conditions, a hybrid microgrid can provide higher system reliability when islanded and have a lower life cycle cost under multiple market conditions than a traditional diesel generator-based system. The improved performance of the hybrid system is resilient to conditions experienced over the last 20 years in solar irradiance and sees little degradation in performance immediately after a hurricane. The cost savings to provide this more resilient backup power system as compared to a diesel-only microgrid are significant. The net present cost for a hybrid microgrid is 19% lower in New Mexico and 35% lower in Maryland than a diesel-only microgrid. In California, the net present cost of the hybrid microgrid is negative because, unlike a diesel-only microgrid, a hybrid microgrid has lower life cycle costs than the power costs without a microgrid.

25 ENERGY STORAGE↗

Model Predictive Control of Dual-Mode Energy-Stored Quasi-Z-Source Photovoltaic System

The energy-stored quasi-Z-source inverter (ES-qZSI) has attracted much attention for photovoltaic (PV) power generations, due to its capability to stabilize the PV power fluctuations and other advantages of Z-source inverter. Traditional ES-qZSI suffers from poor operation at night or cloudy days when PV power is extremely low. In order to overcome that, this paper proposes a model predictive control (MPC) strategy for an improved dual-mode ES-qZSI, which is designed to support all-weather operation of PV power generation system. The system predictive models in both day and night operating modes are derived. And the control strategy based on MPC is disclosed to ensure the high-performance operation of the system. Simulation is carried out on PV power fluctuation in daytime and switching between the two modes, to verify the effectiveness of proposed control strategy.

Xue, Yaosuo↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report: FY19-FY22)

This is the final technical report for the FY19-FY21 research program "R&D to Ensure a Scientific Basis for Qualification Tests and Standards." This research was performed because project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. This program advances PV module reliability of commercial products through identification of reliability needs, characterization that provides scientific understanding of targeted degradation mechanisms, and translation of those data into practical and predictive test protocols and standards. This report describes program scope, results, milestones, and accomplishments over the three-year period of performance.

14 SOLAR ENERGY↗