Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PREAMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A Cryogenic Readout IC with 100 KSPS in-Pixel ADC for Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit (SPROCKET) is a mixed-signal front-end design for the readout of Skipper CCD-in-CMOS image sensors. SPROCKET is fabricated in a 65 nm CMOS process and each pixel occupies a 50$\mu$m $\times$ 50$\mu$m footprint. SPROCKET is intended to be heterogeneously integrated with a Skipper-in-CMOS sensor array, such that one readout pixel is connected to a multiplexed array of nine Skipper-in-CMOS pixels to enable massively parallel readout. The front-end includes a variable gain preamplifier, a correlated double sampling circuit, and a 10-bit serial successive approximation register (SAR) ADC. The circuit achieves a sample rate of 100 ksps with 0.48 $\mathrm{e^-_{rms}}$ equivalent noise at the input to the ADC. SPROCKET achieves a maximum dynamic range of 9,000 $e^-$ at the lowest gain setting (or 900 $e^-$ at the lowest noise setting). The circuit operates at 100 Kelvin with a power consumption of 40 $\mu W$ per pixel. A SPROCKET test chip was submitted in September 2022, and test results will be presented at the conference.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Photovoltaic Cells Operated as Fission Fragment Detectors

The operating principle, interaction with electronic systems, and quantitative performance characteristics of photovoltaic (solar) cells operated as fission fragment detectors are discussed. The depletion region created at the p-n junction of an unbiased photovoltaic device enables its operation as a charged particle detector. The field-funneling effect enhances charge collection arising from dense ion tracks. In this way, fission fragments are easily observed, while the signal produced by light ions remains below the detector noise. When connected to a charge-sensitive preamplifier, the photovoltaic cell exhibited a characteristic rise time of ~1 µs and timing resolution of 32.3 ns FWHM. The energy response was sufficient to clearly separate the light and heavy fission fragment peaks in the energy spectrum. The measured Schmitt parameters indicate slightly worse energy resolution and larger low-energy tailing than expected for a non-field-funneling silicon detector

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Determination of the Multiplicity Deadtime Parameter

Definition, extraction, and application of dead-time parameters, in correlated neutron counting, are long standing, thorny issues. Traditionally, dead-time corrections have been estimated on the assumption of a simple paralyzing model, arising from the action of the discriminator in the charged amplifiers connected to the {sup 3}He proportional counters, using a fixed dead-time. Various schemes exist to apply the paralysable model to the multiplicity shift register histogram data. In principle, several methods could be used to estimate the dead-time parameter. The approach which is most widely applied involves measuring a series of Cf-252 sources spanning a wide dynamic range of counting rates. Ratios between the Singles, Doubles and Triples rates which ought to be independent of fissile mass are extracted. The dead-time is chosen so as to achieve the best independence in the ratios, characteristic of the fissioning system, over the counting range. These measurements can be quite laborious to conduct; require a set of Cf-252 sources matched in construction and isotopic composition; require long counts to achieve the requisite precision and involve a good deal of numerical analysis to interpret. In this work we present a simpler scheme which produces comparable values in a way that is easier to implement. In essence we place a near random neutron source, such as may be realized using Am/Li {alpha}-n sources, in the cavity and record the multiplicity histograms as one would for an assay. The variance to mean-squared is narrower than for a random counting experiment, however, as a result of the dead-time losses. A simple formula exists allowing the deadtime to be extracted from this measurement. In this paper, we present results for the traditional approach, the proposed approach and also a variation based on adjusting the total event rate by adding Am/Li sources to a single Cf-252 source fixed in position for the case of a pair of Passive Scrap Multiplicity Counters (PSMC's). Excellent agreement is obtained. Because the variance to mean squared approach gives high precision in a single, short, measurement it lends itself to studying dead-time behaviors systematically as a function of shift register settings, operating voltage and preamplifier trim. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Universal tritium transmitter

At the Savannah River Site and throughout the National Nuclear Security Agency (NNSA) tritium is measured using Ion or Kanne Chambers. Tritium flowing through an Ion Chamber emits beta particles generating current flow proportional to tritium radioactivity. Currents in the 1 x 10{sup -15} A to 1 x 10{sup -6} A are measured. The distance between the Ion Chamber and the electrometer in NNSA facilities can be over 100 feet. Currents greater than a few micro-amperes can be measured with a simple modification. Typical operating voltages of 500 to 1000 Volts and piping designs require that the Ion Chamber be connected to earth ground. This grounding combined with long cable lengths and low currents requires a very specialized preamplifier circuit. In addition, the electrometer must be able to supply 'fail safe' alarm signals which are used to alert personnel of a tritium leak, trigger divert systems preventing tritium releases to the environment and monitor stack emissions as required by the United States federal Government and state governments. Ideally the electrometer would be 'self monitoring'. Self monitoring would reduce the need for constant checks by maintenance personnel. For example at some DOE facilities monthly calibration and alarm checks must be performed to ensure operation. NNSA presently uses commercially available electrometers designed specifically for this critical application. The problems with these commercial units include: ground loops, high background currents, inflexibility and susceptibility to Electromagnetic Interference (EMI) which includes RF and Magnetic fields. Existing commercial electrometers lack the flexibility to accommodate different Ion Chamber designs required by the gas pressure, type of gas and range. Ideally the electrometer could be programmed for any expected gas, range and high voltage output. Commercially available units do not have 'fail safe' self monitoring capability. Electronics used to measure extremely low current must have sufficient time to thermally equilibrate. Amplifiers, transistors, resistors all need time to stabilize before the electrometer circuit will measure accurately in the 10{sup -15} and 10{sup -14} ampere range. Existing electrometers give the user no indication when the unit has stabilized and is acceptable for low level measurements. Savannah River National Laboratory (SRNL) funded through the NNSA Plant Directed Research and Development (PDRD) program, has developed a truly Universal Tritium Transmitter (UTT) capable of solving many known problems with existing commercial electrometers. This UTT pushes the state-of-the-art in electrometer design and incorporates solutions to deficiencies found in commercial electrometers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development, Testing and Validation of a Waste Assay System for the Measurement and Characterisation of Active Spent Fuel Element Debris From UK Magnox Reactors - 12533

This paper describes the development, testing and validation of a waste measurement instrument for characterising active remote handled radioactive waste arising from the operation of Magnox reactors in the United Kingdom. Following operation in UK Magnox gas cooled reactors and a subsequent period of cooling, parts of the magnesium-aluminium alloy cladding were removed from spent fuel and the uranium fuel rods with the remaining cladding were removed to Sellafield for treatment. The resultant Magnox based spent fuel element debris (FED), which constitutes active intermediate level waste (ILW) has been stored in concrete vaults at the reactor sites. As part of the decommissioning of the FED vaults the FED must be removed, measured and characterised and placed in intermediate storage containers. The present system was developed for use at the Trawsfynydd nuclear power station (NPS), which is in the decommissioning phase, but the approach is potentially applicable to FED characterisation at all of the Magnox reactors. The measurement system consists of a heavily shielded and collimated high purity Germanium (HPGe) detector with electromechanical cooling and a high count-rate preamplifier and digital multichannel pulse height analyser. The HPGe based detector system is controlled by a software code, which stores the measurement result and allows a comprehensive analysis of the measured FED data. Fuel element debris is removed from the vault and placed on a tray to a uniform depth of typically 10 cm for measurement. The tray is positioned approximately 1.2 meters above the detector which views the FED through a tungsten collimator with an inverted pyramid shape. At other Magnox sites the positions may be reversed with the shielded and collimated HPGe detector located above the tray on which the FED is measured. A comprehensive Monte Carlo modelling and analysis of the measurement process has been performed in order to optimise the measurement geometry and eliminate interferences from radioactive sources and FED in the immediate vicinity of the measurement position. The detector system has been calibrated and high activity radioactive sources of Cs-137, Co-60 and Na-22 have been used to validate the measurement process. The data acquisition and analysis software code has been tested and validated in keeping with the software quality assurance requirements of both ISO:9001-2008 - TICK-IT in the UK and NQA-1. The measurement and analysis system has been comprehensively tested with high activity sources, is flexible and may be applicable to a wide range of remote handled radioactive waste measurement applications. It is due to be installed at Trawsfynydd NPS later this year. This paper describes the Waste Tray Assay System (WTAS) that has been developed for the measurement of Magnox FED waste. The WTAS has been tested with a range of radioactive sources and its operation has been simulated with benchmarked MCNP Monte Carlo calculations. The measurement software has been validated as has the operation of the system for a range of strong radioactive sources. A system based on the design is due for installation and operation in 2012. The system has application to the measurement of Magnox Fuel Element Debris (FED) waste at other Magnox reactor sites. The major design objective of the WTAS that has been achieved is the ability of the assay system to determine the content of Cs-137, and in turn to enable the fissile burden to be assessed using a radionuclide fingerprint, in the presence of higher and highly variable quantities of Co-60, typically from nimonic springs. The approach can be used in other Magnox FED waste configurations where the detector is located above the FED waste sorting tray and where the collimation is fixed below the detector and at a distance above the tray. In this case, which has also been investigated, there are different shielding problems and mechanical support issues. The extensive use of MCNP Monte Carlo modelling to simulate the geometry of the sorting cell and the distribution of radioactive sources has helped to ensure that all of the detector shielding requirements are addressed and suitable Cs-137 and Co-60 discrimination can be achieved. The WTAS in its present form or in other configurations has relevance to the measurement of other active ILW and highly active RH waste. Examples include high activity RH LLW and RH TRU (Transuranic) waste as defined in the United States arising from both commercial nuclear and Department of Energy (DOE) operations. The analysis is able to analyse a range of radionuclides beyong those expected in the Magnox FED cases. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Smart Pixels: In-pixel AI for on-sensor data filtering

We present a smart pixel prototype readout integrated circuit (ROIC) designed in CMOS 28 nm bulk process, with in-pixel implementation of an artificial intelligence (AI) / machine learning (ML) based data filtering algorithm designed as proof-of-principle for a Phase III upgrade at the Large Hadron Collider (LHC) pixel detector. The first version of the ROIC consists of two matrices of 256 smart pixels, each 25$\times$25 $\mu$m$^2$ in size. Each pixel consists of a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. The frontend is capable of synchronously digitizing the sensor charge within 25 ns. Measurement results show an equivalent noise charge (ENC) of $\sim$30e$^-$ and a total dispersion of $\sim$100e$^-$ The second version of the ROIC uses a fully connected two-layer neural network (NN) to process information from a cluster of 256 pixels to determine if the pattern corresponds to highly desirable high-momentum particle tracks for selection and readout. The digital NN is embedded in-between analog signal processing regions of the 256 pixels without increasing the pixel size and is implemented as fully combinatorial digital logic to minimize power consumption and eliminate clock distribution, and is active only in the presence of an input signal. The total power consumption of the neural network is $\sim$ 300 $\mu$W. The NN performs momentum classification based on the generated cluster patterns and even with a modest momentum threshold, it is capable of 54.4% - 75.4% total data rejection, opening the possibility of using the pixel information at 40MHz for the trigger. The total power consumption of analog and digital functions per pixel is $\sim$ 6 $\mu$W per pixel, which corresponds to $\sim$ 1 W/cm$^2$ staying within the experimental constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of the Mu2e tracker DAQ, planning for the Vertical Slice Test and pre-pattern recognition studies

The primary objective of the Mu2e experiment at Fermilab is to search for the neutrino-less coherent $\mu \rightarrow e$ conversion in the field of an aluminum nucleus ($\mu^- \text{Al} \rightarrow e^- \text{Al}$). The signature of this process is a monochromatic Conversion Electron (CE) with an energy of approximately 104.97 MeV \cite{bartoszek2015mu2e}. Within the Standard Model (SM), the branching ratio for this process, including neutrino masses and oscillation, is expected to be less than $\mathcal{O}(10^{-50})$. This value is far beyond current experimental capabilities. However, models of physics beyond the SM predict much higher relative rates, approaching an observable level. The SINDRUM II experiment set an upper limit on muon conversion at $7 \times 10^{-13}$ (90\% CL) on Au target \cite{SINDRUMII:2006dvw}, and the Mu2e collaboration aims to improve this limit by four orders of magnitude. Observing this process would provide a clear evidence of physics beyond the Standard Model. A brief discussion of the theoretical and experimental aspects is provided in Chapter \ref{intr}. Mu2e adopts a sophisticated experimental setup to achieve its goals, further described in Chapter \ref{mu2echapter}. The central part of the Mu2e detector is the tracker, that consists of 18 tracking stations. The tracker must provide excellent momentum resolution, approximately 1 MeV/c, to distinguish the monochromatic CE signal from the background. To minimize the energy losses, a straw tube tracker will be used \cite{bobbb}. Chapter \ref{chaptertrk} provides an overview of the straw tracker design and its working principles. This Thesis presents a comprehensive study of the Mu2e tracker, covering complementary aspects from initial commissioning to optimization and first steps of the calibration processes. My work at Fermilab has been focused on the complete Data Acquisition (DAQ) testing from both hardware and software perspectives. I was involved in the commissioning of the Mu2e DAQ system and the Vertical Slice Test (VST) of the tracker. The VST encompasses the entire testing chain, from the straws to the readout, and to processed data on disk. I was also focused on the offline analysis, especially on pre-pattern recognition studies, to explore the best methods for identifying $\delta$-electrons during the data taking. Chapter \ref{commissioning} details the commissioning of the tracker DAQ system, emphasizing the importance of understanding of the readout process before the data acquisition. This includes validating the readout logic and firmware through Monte Carlo simulations to confirm functionality and buffering, monitoring the quality of the data from the tracker preamplifiers and front-end electronics, and assessing overall DAQ performance to ensure reliability during future calibration and data-taking. Chapter \ref{planning} discusses the initial steps towards the tracker calibration. The ultimate goal is to perform a time calibration of the first assembled station of the tracker using cosmic muons, aiming for a longitudinal hit position resolution better than 4 cm. This involves determining the signal propagation times and channel-to-channel delays. I performed a Monte Carlo study to determine the impact of the station orientation on the quality of the calibration, in particular on the cosmic track reconstruction, focusing on potential biases that could arise. These studies provide essential insights into the operation, optimization, and calibration of the Mu2e tracker system. Given the high data volume expected during Mu2e operations, estimated at approximately 7 PBytes per year, optimizing memory usage and minimizing CPU consumption are critical. A significant challenge lies in effectively flagging $\delta$-electron hits, which are the primary source of hits in the tracker, without compromising the efficiency of CE hit detection and track reconstruction. A detailed study of pre-pattern recognition and a thorough comparison of two $\delta$-electron flagging algorithms is provided in Chapter \ref{delta}. In Chapter \ref{conclusions}, the findings are concisely summarized, offering a comprehensive synthesis of the research and emphasizing the key insights derived from this study.

43 PARTICLE ACCELERATORS↗

Novel, Middle and Long Wave Infrared Laser Sources For Accelerator Applications

The main accomplishment during Years 2020-2024 of the DOE Accelerator Stewardship Program is proof-of-principle demonstration of amplification of an ultrashort 10 µm seed pulse in a multiatmosphere CO 2 laser optically pumped by nanosecond pulses of either a ~4.3 µm Fe:ZnSe laser or a 2.8 µm electro-optically (EO) Q-switched Er: Laser. This has been accomplished at the UCLA Neptune Laboratory by using about 100 mJ, ~100 ns long pulses generated by the pump laser built for this purpose by the UAB team. Implementation of EO Q-switching regime in the solid-state Er:laser system made possible nanosecond synchronization between the pump pulse and the 0.5 ps seed pulse produced by a commercial Ti:sapphire laser based mid-IR OPA/DFG. The injection mode-locking regime realized in a compact Mult atmosphere 3 Hz CO 2 -He regenerative amplifier enabled generation of a train of ultrashort pulses separated by the cavity round-trip time of ~3.2 ns. The measured gain lifetime of ~1 µs at a total pressure of ~12-15 atm indicates that lifetime of the upper laser level is a critical limiting factor in designing high-pressure CO 2 amplifiers. A single picosecond 10 mm pulse with an energy 0.1-0.2 mJ was extracted from the amplifier’s cavity using an ultrafast Ge semiconductor switch whose reflectivity was photo-induced by a femtosecond 800 nm pulse. For direct amplification regime, nonlinear absorption in Ge at 10 mm at GW/cm 2 intensities limited the extracted energy. Therefore, the generated energy could be further increased by minimizing losses in the switch and optimizing the cavity mode size. Based on the obtained data in collaboration with BNL colleagues, we have designed a high-pressure CO 2 amplifier to be used as a preamplifier for the future experiments at the ATF BNL. The latter work is the subject of funding availability.

60 APPLIED LIFE SCIENCES↗

Mu2e Tracker Electronics - Construction of a Straw Tracker

The Mu2e experiment, currently under construction at the Fermi National Accelerator Laboratory (FNAL) in Batavia, Illinois, is a particle physics experiment designed to detect Charged Lepton Flavor Violation (CLFV) via muon-to-electron conversion, a process beyond the Standard Model (BSM). One of the primary Mu2e detectors is the Straw Tracker, whose purpose is to measure the momentum of the electron, identify the signal, and reject background. The straw tubes are being read out by a total of 20,736 preamplifiers (preamps) within 36 planes that make up the Tracker. In this presentation, the installation of electronics into the Tracker, the implementation of anti-oscillation copper clips, and the process of installing fully constructed planes into the frame will be discussed in depth.

Lynch, Alec [UC, Berkeley]↗

Mu2e Tracker Electronics - Construction of a Straw Tracker

The Mu2e experiment, located at the Fermi National Accelerator Laboratory (FNAL), also known as Fermilab, in Batavia, Illinois, is an in-progress particle physics experiment aiming to detect Charged Lepton Flavor Violation (CLFV) via the $\mu^-Al\rightarrow e^-Al$ interaction, a Beyond the Standard Model (BSM) process. One of the sections of the Mu2e experiment is the Tracker, which aims to identify the signal and reject the background while the experiment is running. A total of 20,736 Calibration (CAL) and High-Voltage (HV) preamplifiers (preamps) are being installed within 36 planes that make up the Tracker. During this process, MHz oscillations were discovered on the CAL preamps, obscuring desired signal detection in the \~kHz range. To solve this issue, copper clips are installed onto the CALs to remove the MHz oscillations. The installation of electronics into the Tracker will be discussed in depth.

Lynch, Alec Michael [UC, Berkeley; Fermilab]↗

Monolithic pixel detectors in a deep submicron SOI process

A compact charge-signal processing chain, composed of a two-stage semi-gaussian preamplifier-signal shaping filter, a discriminator and a binary counter, implemented in a prototype pixel detector using 0.20 {micro}m CMOS Silicon on Insulator process, is presented. The gain of the analog chain was measured 0.76 V/fC at the signal peaking time about 300 ns and the equivalent noise charge referred to the input of 80 e{sup -1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new timing detector for the CT-PPS project

The CT-PPS detector will be installed close to the beam line on both sides of CMS, 200 m downstream the interaction point. This detector will measure forward scattered protons, allowing detailed studies of diffractive hadron physics and Central Exclusive Production. The main components of the CT-PPS detector are a silicon tracking system and a timing system. In this contribution we present the proposal of an innovative solution for the timing system, based on Ultra-Fast Silicon Detectors (UFSD). UFSD are a novel concept of silicon detectors potentially able to obtain the necessary time resolution (~20 ps on the proton arrival time). The use of UFSD has also other attractive features as its material budget is small and the pixel geometries can be tailored to the precise physics distribution of protons. UFSD prototypes for CT-PPS have been designed by CNM (Barcelona) and FBK (Trento): we will present the status of the sensor productions and of the low-noise front-end electronics currently under development and test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a low noise detection circuit for probing the structure of damage cascades with IBIC

Optimal detector / pre-amplifier combinations have been identified for the use of light ion IBIC (ion beam induced charge) to probe the physical structure of electrically active defects in damage cascades caused by heavy ion implantation. The ideal detector must have a sufficiently thin dead layer that incident ions will produce the majority of damage cascades in the depletion region of the detector rather than the dead layer. Detector and circuit noise must be low enough to detect the implantation of a single heavy ion as well as the decrease in the light ion IBIC signal caused by Shockley-Read-Hall recombination when the beam scans regions of the detector damaged by the heavy ion. The IBIC signals from three detectors irradiated with 750 keV He⁺ ions are measured with commercial and bespoke charge sensitive pre-amplifiers to identify the combination with the lowest noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

Design and Characterization of the Engineering Model of the Spectrometer Onboard LuSEE-Night

The Lunar Surface Electromagnetics Explorer - Night, LuSEE-Night, is a low-frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio quiet farside of the Moon. The LuSEE-Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA's Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5−50MHz band. The engineering model (EM) of the four-channel spectrometer has been developed. The EM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the EM meets all the requirements for LuSEE-Night. Three mitigation techniques have been implemented and verified to suppress self-induced electromagnetic interference (EMI). The flight model of the spectrometer is currently being developed and is scheduled to be shipped to the integration site in early 2024

47 OTHER INSTRUMENTATION↗

Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Maser Experiment

Functional maser consisting of amplifier, low noise header and superconducting magnet for use in ATS satellite

APPLICATIONS TECHNOLOGY SATELLITE /ATS/↗