Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA DIAGNOSTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Design study of a combined interferometer and polarimeter for a high-field, compact tokamak

This article is the first design study of a combined interferometer and polarimeter on a compact, high-field, high-density, net-energy tokamak. Recent advances in superconducting technology have made possible designs for compact, high magnetic field fusion power plants, such as ARC [Sorbom et al., Fusion Eng. Des. 100, 378 (2015)], and experiments, such as SPARC [Greenwald et al., PSFC Report No. RR-18-2 (2018)]. These new designs create both challenges and opportunities for plasma diagnostics. The diagnostic proposed in this work, called InterPol, takes advantage of unique opportunities provided by high magnetic field and density to measure both line-averaged density and poloidal magnetic field with a single set of CO 2 and quantum cascade lasers. These measurements will be used for fast density feedback control, constraint of density and safety factor profiles, and density fluctuation measurements. Synthetic diagnostic testing using a model machine geometry, called MQ1 (Mission Q ≥ 1), and profiles simulated with Tokamak Simulation Code indicate that InterPol will be able to measure steady state density and poloidal magnetic field, as well as fluctuations caused by toroidal Alfven eigenmodes and other phenomena on a high-field compact tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CHIANTI-AN ATOMIC DATABASE FOR EMISSION LINES. XII. VERSION 7 OF THE DATABASE

The CHIANTI spectral code consists of an atomic database and a suite of computer programs to calculate the optically thin spectrum of astrophysical objects and carry out spectroscopic plasma diagnostics. The database includes atomic energy levels, wavelengths, radiative transition probabilities, collision excitation rate coefficients, and ionization and recombination rate coefficients, as well as data to calculate free-free, free-bound, and two-photon continuum emission. Version 7 has been released, which includes several new ions, significant updates to existing ions, as well as Chianti-Py, the implementation of CHIANTI software in the Python programming language. All data and programs are freely available at http://www.chiantidatabase.org, while the Python interface to CHIANTI can be found at http://chiantipy.sourceforge.net.

79 ASTRONOMY AND ASTROPHYSICS↗

Overview of NASA's Solar Electric Propulsion Project

NASA is continuing to develop and qualify a state of the art 13 kW-class Advanced Electric Propulsion System (AEPS) for NASA exploration missions through a contract with Aerojet Rocketdyne (AR). An objective of the AEPS project is accelerate the adoption of high power electric propulsion technologies by reducing the risk and uncertainty of integrating Solar Electric Propulsion (SEP) technologies into space flight systems. NASA and AR have recently initiated testing of engineering hardware including the Hall Current Thruster (HCT), Power Processing Unit (PPU), and Xenon Flow Controller (XFC) at both the component and system levels. The successful completion of these tests will provide the required information to advance the AEPS system towards Critical Design Review. In support of the AEPS contract, NASA and JPL have been performing risk reduction activities to address specific concerns of this higher power Hall thruster propulsion system. These risk reduction activities have included long duration wear testing of the Technology Demonstration Unit (TDU) Hall thruster and cathode hardware, thermal cycling of TDU cathode heaters and coils, plasma plume measurements, and performed early circuit testing of the AEPS PPU design. In addition to the propulsion system development, the SEP project is developing the Plasma Diagnostic Package (PDP) and the SEP Testbed. The PDP is designed for use in conjunction with a high-powered electric propulsion (EP) system to characterize in-space operation. The SEP Testbed system is being developed to demonstrate integrated SEP system performance. The paper presents an overview of the NASA and the AEPS contract activities and a summary of the associated NASA in-house activities.

Plasma diagnostics package↗

Experimental and Theoretical Analysis of Central H{sub {beta}} Asymmetry

The hydrogen Balmer beta line is used as a plasma diagnostics tool for a long time. It is well known that the experimental profiles of H{sub {beta}} line exhibit an asymmetry while some of most commonly used theoretical models, due to the employed approximations, give unshifted and symmetrical profiles. In the present work the central part of H{sub {beta}} profile is reanalyzed experimentally and in terms of two theoretical approaches based correspondingly on the Standard Theory (ST) assumptions and on the electric field computer simulation method. The present experimental and theoretical results are compared with the obtained earlier experimental and theoretical data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of a bolometer detector for ITER based on Pt absorber on SiN membrane

Any plasma diagnostic in ITER must be able to operate at temperatures in excess of 200 deg. C and neutron loads corresponding to 0.1 dpa over its lifetime. To achieve this aim for the bolometer diagnostic, a miniaturized metal resistor bolometer detector based on Pt absorbers galvanically deposited on SiN membranes is being developed. The first two generations of detectors featured up to 4.5 {mu}m thick absorbers. Results from laboratory tests are presented characterizing the dependence of their calibration constants under thermal loads up to 450 deg. C. Several detectors have been tested in ASDEX Upgrade providing reliable data but also pointing out the need for further optimization. A laser trimming procedure has been implemented to reduce the mismatch in meander resistances below 1% for one detector and the thermal drifts from this mismatch.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE ROLE OF DIFFUSIVE SHOCK ACCELERATION ON NONEQUILIBRIUM IONIZATION IN SUPERNOVA REMNANT SHOCKS. II. EMITTED SPECTRA

We present a grid of nonequilibrium ionization models for the X-ray spectra from supernova remnants undergoing efficient diffusive shock acceleration. The calculation follows the hydrodynamics of the blast wave as well as the time-dependent ionization of the plasma behind the shock. The ionization state is passed to a plasma emissivity code to compute the thermal X-ray emission, which is combined with the emission from nonthermal synchrotron emission to produce a self-consistent model for the thermal and nonthermal emission from cosmic-ray dominated shocks. We show how plasma diagnostics such as the G'-ratio of He-like ions, defined as the ratio of the sum of the intercombination, forbidden, and satellite lines to the resonance line, can vary with acceleration efficiency, and discuss how the thermal X-ray emission, when the time-dependent ionization is not calculated self-consistently with the hydrodynamics, can differ from the thermal X-ray emission from models which do account for the hydrodynamics. Finally, we compare the thermal X-ray emission from models which show moderate acceleration ({approx}35%) to the thermal X-ray emission from test-particle models.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy levels, wavelengths, and transition rates of multipole transitions (E1, E2, M1, M2) in Au{sup 67+} and Au{sup 66+} ions

The fully relativistic configuration interaction method of the FAC code is used to calculate atomic data for multipole transitions in Mg-like Au (Au{sup 67+}) and Al-like Au (Au{sup 66+}) ions. Generated atomic data are important in the modeling of M-shell spectra for heavy Au ions and Au plasma diagnostics. Energy levels, oscillator strengths and transition rates are calculated for electric-dipole (E1), electric quadrupole (E2), magnetic dipole (M1), and magnetic quadrupole (M2) for transitions between excited and ground states 3l−nl{sup ′}, such that n=4,5,6,7. The local central potential is derived using the Dirac–Fock–Slater method. Correlation effects to all orders are considered by the configuration interaction expansion. All relativistic effects are included in the calculations. Calculated energy levels are compared against published values that were calculated using the multi-reference many body perturbation theory, which includes higher order QED effects. Favorable agreement was observed, with less than 0.15% difference.

74 ATOMIC AND MOLECULAR PHYSICS↗

Reproducibility of the cutoff probe for the measurement of electron density

Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CHIANTI-AN ATOMIC DATABASE FOR EMISSION LINES. XIII. SOFT X-RAY IMPROVEMENTS AND OTHER CHANGES

The CHIANTI spectral code consists of two parts: an atomic database and a suite of computer programs in Python and IDL. Together, they allow the calculation of the optically thin spectrum of astrophysical objects and provide spectroscopic plasma diagnostics for the analysis of astrophysical spectra. The database includes atomic energy levels, wavelengths, radiative transition probabilities, collision excitation rate coefficients, ionization, and recombination rate coefficients, as well as data to calculate free-free, free-bound, and two-photon continuum emission. Version 7.1 has been released, which includes improved data for several ions, recombination rates, and element abundances. In particular, it provides a large expansion of the CHIANTI models for key Fe ions from Fe VIII to Fe XIV to improve the predicted emission in the 50-170 A wavelength range. All data and programs are freely available at http://www.chiantidatabase.org and in SolarSoft, while the Python interface to CHIANTI can be found at http://chiantipy.sourceforge.net.

79 ASTRONOMY AND ASTROPHYSICS↗

CHIANTI-AN ATOMIC DATABASE FOR EMISSION LINES. XI. EXTREME-ULTRAVIOLET EMISSION LINES OF Fe VII, Fe VIII, AND Fe IX OBSERVED BY HINODE/EIS

A detailed study of emission lines from Fe VII, Fe VIII, and Fe IX observed by the EUV Imaging Spectrometer on board the Hinode satellite is presented. Spectra in the ranges 170-212 A and 246-292 A show strongly enhanced lines from the upper solar transition region (temperatures 5.4 <= log T <= 5.9) allowing a number of new line identifications to be made. Comparisons of Fe VII lines with predictions from a new atomic model reveal new plasma diagnostics, however there are a number of disagreements between theory and observation for emission line ratios insensitive to density and temperature, suggesting improved atomic data are required. Line ratios for Fe VIII also show discrepancies with theory, with the strong lambda185.21 and lambda186.60 lines underestimated by 60%-80% compared to lines between 192 and 198 A. A newly identified multiplet between 253.9 and 255.8 A offers excellent temperature diagnostic opportunities relative to the lines between 185 and 198 A, however the atomic model underestimates the strength of these lines by factors of 3-6. Two new line identifications are made for Fe IX at wavelengths 176.959 A and 177.594 A, while seven other lines between 186 and 200 A are suggested to be due to Fe IX but for which transition identifications cannot be made. The new atomic data for Fe VII and Fe IX are demonstrated to significantly modify models for the response function of the Transition Region And Coronal Explorer 195 A imaging channel, affecting temperature determinations from this channel. The data will also affect the response functions for other solar EUV imaging instruments such as SOHO/EIT, STEREO/EUVI, and the upcoming AIA instrument on the Solar Dynamics Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of fast steering mirror control system for plasma heating and diagnostics

A control system for a fast steering mirror has been newly developed for the electron cyclotron heating (ECH) launchers in the large helical device. This system enables two-dimensional scan during a plasma discharge and provides a simple feedback control function. A board mounted with a field programmable gate array chip has been designed to realize feedback control of the ECH beam position to maintain higher electron temperature by ECH. The heating position is determined by a plasma diagnostic signal related to the electron temperature such as electron cyclotron emission and Thomson scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of transmission line attenuation in broad band millimeter wave frequency range

Broad band millimeter wave transmission lines are used in fusion plasma diagnostics such as electron cyclotron emission (ECE), electron cyclotron absorption, reflectometry and interferometry systems. In particular, the ECE diagnostic for ITER will require efficient transmission over an ultra wide band, 100 to 1000 GHz. A circular corrugated waveguide transmission line is a prospective candidate to transmit such wide band with low attenuation. To evaluate this system, experiments of transmission line attenuation were performed and compared with theoretical loss calculations. A millimeter wave Michelson interferometer and a liquid nitrogen black body source are used to perform all the experiments. Atmospheric water vapor lines and continuum absorption within this band are reported. Ohmic attenuation in corrugated waveguide is very low; however, there is Bragg scattering and higher order mode conversion that can cause significant attenuation in this transmission line. The attenuation due to miter bends, gaps, joints, and curvature are estimated. The measured attenuation of 15 m length with seven miter bends and eighteen joints is 1 dB at low frequency (300 GHz) and 10 dB at high frequency (900 GHz), respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE TEMPERATURE AND DENSITY STRUCTURE OF THE SOLAR CORONA. I. OBSERVATIONS OF THE QUIET SUN WITH THE EUV IMAGING SPECTROMETER ON HINODE

Measurements of the temperature and density structure of the solar corona provide critical constraints on theories of coronal heating. Unfortunately, the complexity of the solar atmosphere, observational uncertainties, and the limitations of current atomic calculations, particularly those for Fe, all conspire to make this task very difficult. A critical assessment of plasma diagnostics in the corona is essential to making progress on the coronal heating problem. In this paper, we present an analysis of temperature and density measurements above the limb in the quiet corona using new observations from the EUV Imaging Spectrometer (EIS) on Hinode. By comparing the Si and Fe emission observed with EIS we are able to identify emission lines that yield consistent emission measure distributions. With these data we find that the distribution of temperatures in the quiet corona above the limb is strongly peaked near 1 MK, consistent with previous studies. We also find, however, that there is a tail in the emission measure distribution that extends to higher temperatures. EIS density measurements from several density sensitive line ratios are found to be generally consistent with each other and with previous measurements in the quiet corona. Our analysis, however, also indicates that a significant fraction of the weaker emission lines observed in the EIS wavelength ranges cannot be understood with current atomic data.

99 GENERAL AND MISCELLANEOUS↗

Measurement of electron temperature and ion density using the self-bias effect in plasmas

For novel plasma diagnostics, the rf floating probe was revisited. For inducing the self-bias effect, ac bias voltage (approxkilohertz) was applied through a dc blocking capacitor between a probe and a signal generator. The dc self-bias potential was changed not only with ac bias voltages but also with electron temperatures, and therefore, the electron temperature was derived from the variations in the self-bias potential with and without ac bias voltage. The harmonic component of the probe contains information about the ion flux, and using a fast Fourier transform analysis of the probe current, the ion density was derived from the first harmonic current of the probe. The experimental results were compared with a single Langmuir probe. The electron temperature and the ion density were in good agreement with those from the Langmuir probe. Because the amplitude of the ac bias voltage is very low (<3 V), local ionizations affected by a high bias-voltage can be neglected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Study of the Aligned-Grid Retarding Potential Analyzer for Electric Propulsion Applications

During the development of energy analyzers for NASA’s Solar Electric Propulsion Plasma Diagnostics Package, detailed studies were performed to compare the benefits and drawbacks of different types of gridded potential analyzers. In particular, modeling and testing were performed on three types of retarding potential analyzer with aligned grids, and one type with unaligned grids. Additionally, a type of gridded energy analyzer was tested. Analyses of the model and test results showed that manufacturing an analyzer with aligned grids required greater precision and knowledge than other analyzers. A properly designed analyzer with aligned grids exhibited superior signal level, acceptance angle control, energy resolution, and compactness compared to an analyzer with unaligned grids. Additionally, the gridded energy analyzer was found to accept a broad range of incidence angles while having superior signal, energy resolution, and compactness compared to retarding potential analyzer with unaligned grid. This article describes the basic design principles deployed in the study, the associated modeling work, and the characterization tests that were performed. The article summarizes the benefits and drawbacks associated with each type of energy analyzer tested.

Electric Propulsion↗

Proton damage in (Y,Lu,Gd) 3 (Al,Ga) 5 O 12 :Ce mixed garnet scintillators

Scintillators are vital components for nuclear instrumentation and its applications, including plasma diagnostics and imaging. As yields in controlled fusion experiments increase, the radiation tolerance of scintillator candidates for use in instrumentation is of particular importance. High radiation exposure can damage scintillating materials and alter the optical properties. The effects of radiation damage in Ce-doped mixed garnet ceramics over the compositional range (Y,Gd,Lu) 3 (Al,Ga) 5 O 12 are investigated using optical techniques. The samples were exposed to 200 keV protons to an accumulated fluence of 10 16 protons per square centimeter, then characterized using diffuse reflectance spectroscopy (DRS). DRS with visible light can assess the radiation tolerance of opaque poly-crystalline samples, which can be easily sintered from powders and thus offer distinct advantages in characterization compared to single crystals. Qualitative trends in induced absorption are presented as a function of composition, and the ideal cerium dopant concentration for Y 2 LuAl 5 O 12 is determined to be 0.60–0.75 mol.%.

47 OTHER INSTRUMENTATION↗

Masking a CCD camera allows multichord charge exchange spectroscopy measurements at high speed on the DIII-D tokamak

Charge exchange spectroscopy is one of the standard plasma diagnostic techniques used in tokamak research to determine ion temperature, rotation speed, particle density, and radial electric field. Configuring a charge coupled device (CCD) camera to serve as a detector in such a system requires a trade-off between the competing desires to detect light from as many independent spatial views as possible while still obtaining the best possible time resolution. High time resolution is essential, for example, for studying transient phenomena such as edge localized modes. By installing a mask in front of a camera with a 1024 x 1024 pixel CCD chip, we are able to acquire spectra from eight separate views while still achieving a minimum time resolution of 0.2 ms. The mask separates the light from the eight spectra, preventing spatial and temporal cross talk. A key part of the design was devising a compact translation stage which attaches to the front of the camera and allows adjustment of the position of the mask openings relative to the CCD surface. The stage is thin enough to fit into the restricted space between the CCD camera and the spectrometer endplate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Irradiation Effects on Dielectric Mirrors for Fusion Power Reactor Application

The use of dielectric mirrors has been considered over the past few decades for both magnetic and inertial confinement systems. These mirrors are comprised of multiple thin bi-layers of high and low refractive index materials deposited onto a substrate. For magnetic fusion systems, dielectric materials are being primarily considered for use in plasma diagnostic systems. For the High Average Power Laser (HAPL) inertial fusion power program, dielectric mirrors are being considered for reflecting the laser beam through the reactor structure. This paper discusses the neutron exposure expected in the HAPL dielectric mirrors and an experimental program comprised of fabrication of advanced dielectric mirrors and testing of these mirrors exposed to prototypical irradiation environment. The specific purpose of the fabrication program was to screen mirror types for their irradiation performance. Specifically, three dielectric mirror types were fabricated to reflect at the KrF laser wavelength of 248 nm and these mirrors irradiated at ~ 175 C in the dose range of 0.001 to 0.1 x 1025 n/m2 (E>0.1 MeV.) The neutron dose range spans the HAPL fluences expected based on calculations from with a recently developed 3-D Monte Carlo code. Mirror reflectivity was measured on as-irradiated and on 300 and 400 C vacuum annealed mirrors. The best performing mirror overall, the alumina/silica multilayer mirror, did not appear to have degraded reflectivity in the as-irradiated or the as-irradiated and annealed conditions. For the highest dose, annealed condition degradation was observed in the hafnia silica mirror. Additionally, laser induced damage threshold (LIDT) was measured on the best performing mirror (the alumina/silica mirror) with a resulting threshold of > 1 J/cm2, and little effect of the neutron irradiation. These findings are somewhat in contradiction to earlier work on dielectric mirrors, which suggested poor performance of dielectric mirrors at an order of magnitude lower neutron dose. In conclusion, the current findings, while preliminary, suggest the possibility for using dielectric mirrors to much high dose levels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗