Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A binary coherent optical receiver for the free-space channel

The structure of a coherent binary optical MAP receiver was derived and the effects of background radiation and phase estimation errors on receiver performance were evaluated. It was found that random phase errors do not affect the performance of the coherent receiver significantly, as long as the standard deviation of the phase error remains less than roughly 0.14 radians (or 8 degrees). It was also shown that background radiation is effectively suppressed by the optical homodyne receiver: Significant deterioration in receiver performance is observed only in the presence of extremely intense background fields. The most notable characteristic of the binary optical homodyne receiver therefore appears to be its ability to achieve quantum limited performance in high background environments, provided that sufficiently accurate estimates of the received phase can be obtained.

Vilnrotter, V. A.↗

Beam-pointing errors of planar-phased arrays.

Using both analytical and Monte Carlo techniques, beam-pointing errors of planar-phased arrays are analyzed. The obtained simple formulas for rms pointing errors are applicable to uniform planar arrays with both uniform and Gaussian uncorrelated phase-error distributions and for any arbitrary scan angle.

Carver, K. R.↗

A probability density function model describing height estimation uncertainty due to image pixel intensity noise in digital fringe projection measurements

Digital fringe projection is a surface-profiling technique used for highly accurate non-contact measurements. As with any measurement technique, a variety of sources degrade to the measurement accuracy of the method. Here, this paper presents an analytically-derived probability density function that explicitly models the surface height measurement error due to inevitable phase measurement error, and it includes the specific case of pixel noise inducing the phase measurement error that ultimately leads to the height estimation error. The accuracy of the model was validated through Monte-Carlo simulations of resultant height distributions subject to arbitrarily correlated pixel intensity noise and experimental digital fringe projection measurements where the pixel-by-pixel height uncertainty estimations were compared to the predictions of the derived model.

42 ENGINEERING↗

Coronagraphic Amplitude and Phase Correction for Detecting Planets

Detection of earth-like planets around other stars using coronagraphy requires the optical beam into the coronagraph to be extremely uniform in both phase and amplitude. Errors in phase can be corrected using a deformable mirror, and error in amplitude can be corrected using a spatial light modulator, both in the pupil plan,a. These corrections can be combined using a Michelson interferometer. If amplitude corrections of only a few percent range are needed, the required accuracy of 10 (circumflex) -4 can be obtained with spatial light modulators with the modest dynamic range of 8 bits.

Woodgate, Bruce E.↗

Deterministic polarization-entanglement purification using spatial entanglement

We present an efficient entanglement purification protocol with hyperentanglement in which additional spatial entanglement is utilized to purify the two-particle polarization-entangled state. The bit-flip error and phase-flip error can be corrected and eliminated in one step. Two remote parties can obtain maximally entangled polarization states deterministically and only passive linear optics are employed. We also discuss the protocol with practical quantum source and noisy channel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incorporation of probabilistic seismic phase labels into a Bayesian multiple-event seismic locator

We add probabilistic phase labels to the multiple-event joint probability function of Myers et al., 2007 that formerly included event locations, travel-time corrections, and arrival-time measurement precision. Prior information on any of the multiple-event parameters may be used. The phase-label model includes a null label that captures phases not belonging to the collection of phases under consideration. Using the Markov-Chain Monte Carlo method, samples are drawn from the multiple-event joint probability function to infer the posteriori distribution that is consistent with priors and the arrival-time data set. Using this approach phase-label error can be accessed and phase-label error is propagated to all other multiple-event parameters. We test the method using a ground-truth data set of nuclear explosions at the Nevada Test Site. We find that posteriori phase labels agree with the meticulously analyzed data set in more than 97% of instances and the results are robust even when the input phase-label information is discarded. Only when a large percentage of the arrival-time data are corrupted does prior phase label information improve resolution of multiple-event parameters. Simultaneous modeling of the entire multiple-event system results in accurate posteriori probability regions for each multiple-event parameter.

58 GEOSCIENCES↗

Broadband Performance of TPF's High-contrast Imaging Testbed: Modeling and Simulations

The broadband performance of the high-contrast imaging testbed (HCIT) at JPL is investigated through optical modeling and simulations. The analytical tool is an optical simulation algorithm developed by combining the HCIT's optical model with a speckle-nulling algorithm that operates directly on coronagraphic images, an algorithm identical to the one currently being used on the HCIT to actively suppress scattered light via a deformable mirror. It is capable of performing full three-dimensional end-to-end near-field diffraction analysis on the HCIT's optical system. By conducting speckle-nulling optimization, we clarify the HCIT's capability and limitations in terms of its broadband contrast performance under various realistic conditions. Considered cases include non-ideal occulting masks, such as a mask with optical density and wavelength dependent parasitic phase-delay errors (i.e., a not band-limited occulting mask) and the one with an optical-density profile corresponding to a measured, non-standard profile, as well as the independently measured phase errors of all optics. Most of the information gathered on the HCIT's optical components through measurement and characterization over the last several years at JPL has been used in this analysis to make the predictions as accurate as possible. The best contrast values predicted so far by our simulations obtainable on the HCIT illuminated with a broadband light having a bandwidth of 80nm and centered at 800nm wavelength are Cm=1.1x10-8 (mean) and C4=4.9x10-8 (at 4(lamda)/D), respectively. In this paper we report our preliminary findings about the broadband light performance of the HCIT.

integrated modeling↗

Design of communication systems using short-constraint-length convolutional codes.

A method is presented for calculating the effect of carrier-phase reference error in a receiver phase-locked loop on bit error rates in convolutionally coded data, for the practical design of systems using short-constraint-length convolutional codes. A set of design curves shows the relation between design bit error rate, uplink carrier tracking loop SNR, downlink total SNR, and downlink modulation index. These curves make possible rapid and simple system optimization.

Merrill, H. M.↗

Configuration study for a 30 GHz monolithic receive array, volume 1

Gregorian, Cassegrain, and single reflector systems were analyzed in configuration studies for communications satellite receive antennas. Parametric design and performance curves were generated. A preliminary design of each reflector/feed system was derived including radiating elements, beam-former network, beamsteering system, and MMIC module architecture. Performance estimates and component requirements were developed for each design. A recommended design was selected for both the scanning beam and the fixed beam case. Detailed design and performance analysis results are presented for the selected Cassegrain configurations. The final design point is characterized in detail and performance measures evaluated in terms of gain, sidelobe level, noise figure, carrier-to-interference ratio, prime power, and beamsteering. The effects of mutual coupling and excitation errors (including phase and amplitude quantization errors) are evaluated. Mechanical assembly drawings are given for the final design point. Thermal design requirements are addressed in the mechanical design.

Nester, W. H.↗

WFIRST Coronagraph: Digging Dark-Holes with Partially Corrected Pupil Phase

The WFIRST coronagraph employs two sequential deformable mirrors to compensate for phase and amplitude errors in the coronagraph optical system. In such a system the actuators of the deformable mirrors would be used for two purposes: To flatten the overall wavefront errors at a system pupil, and to create "dark-holes". The actuators have limited stroke ranges. Therefore, if the pupil phase errors are relatively large, flattening them completely could use up a significant portion of the actuator stroke, sometimes leaving insufficient stroke for creating the dark-holes. We have investigated the impact of partially-corrected pupil phase errors on a Hybrid Lyot Coronagraph (HLC) broadband contrast performance. The predicted broadband contrast floor and the contrast chromaticity agree well with those measured on the HLC testbed.

Poberezhskiy, Ilya↗

Rare events and Griffiths phases in topological quantum error correction

The performance of quantum error correcting (QEC) codes is often studied under the assumption of spatiotemporally uniform error rates. On the other hand, experimental implementations almost always produce heterogeneous error rates, in either space or time, as a result of effects such as imperfect fabrication and/or cosmic rays. It is therefore important to understand if and how their presence can affect the performance of QEC in qualitative ways. Here, in this work, we study the effects of nonuniform error rates in the representative examples of the 1D repetition code and the 2D toric code, focusing on when they have extended spatiotemporal correlations; these may arise, for instance, from rare events (such as cosmic rays) that temporarily elevate error rates over the entire code patch. These effects can be described in the corresponding statistical mechanics models for decoding, where long-range correlations in the error rates lead to extended rare regions of weaker coupling. For the 1D repetition code where the rare regions are linear, we find two distinct decodable phases: a conventional ordered phase in which logical failure rates decay exponentially with the code distance, and a rare-region dominated Griffiths phase in which failure rates are parametrically larger and decay as a stretched exponential. In particular, the latter phase is present when the error rates in the rare regions are above the bulk threshold. For the 2D toric code where the rare regions are planar, we find no decodable Griffiths phase: rare events which boost error rates above the bulk threshold lead to an asymptotic loss of threshold and failure to decode. Unpacking the failure mechanism implies that techniques for suppressing extended sequences of repeated rare events (which, without intervention, will be statistically present with high probability) will be crucial for QEC with the toric code.

classical statistical mechanics↗

Design of error-compensating algorithms for sinusoidal phase shifting interferometry

An improved approach to interferometry using sinusoidal phase shifting balances several harmonic components in the interference signal against each other. The resulting computationally efficient phase-estimation algorithms have low sensitivity to errors such as spurious intensity noise, vibration, and errors in the phase shift pattern. Specific example algorithms employing 8 and 12 camera frames illustrate design principles that are extendable to algorithms of any length for applications that would benefit from a simplified, sinusoidal phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring Cyclic Error in Laser Heterodyne Interferometers

An improved method and apparatus have been devised for measuring cyclic errors in the readouts of laser heterodyne interferometers that are configured and operated as displacement gauges. The cyclic errors arise as a consequence of mixing of spurious optical and electrical signals in beam launchers that are subsystems of such interferometers. The conventional approach to measurement of cyclic error involves phase measurements and yields values precise to within about 10 pm over air optical paths at laser wavelengths in the visible and near infrared. The present approach, which involves amplitude measurements instead of phase measurements, yields values precise to about .0.1 microns . about 100 times the precision of the conventional approach. In a displacement gauge of the type of interest here, the laser heterodyne interferometer is used to measure any change in distance along an optical axis between two corner-cube retroreflectors. One of the corner-cube retroreflectors is mounted on a piezoelectric transducer (see figure), which is used to introduce a low-frequency periodic displacement that can be measured by the gauges. The transducer is excited at a frequency of 9 Hz by a triangular waveform to generate a 9-Hz triangular-wave displacement having an amplitude of 25 microns. The displacement gives rise to both amplitude and phase modulation of the heterodyne signals in the gauges. The modulation includes cyclic error components, and the magnitude of the cyclic-error component of the phase modulation is what one needs to measure in order to determine the magnitude of the cyclic displacement error. The precision attainable in the conventional (phase measurement) approach to measuring cyclic error is limited because the phase measurements are af-

Ryan, Daniel↗