Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

AI-Science for Performance Optimization and Diagnosis of Science Instrument Federations

Next generation of science workflows are expected to be executed over complex federations composed of supercomputers, science instruments, storage systems and networks, with new additions of the edge and cloud systems and services. The sheer complexity of these multi-domain federations makes it hard to manage them and optimize their performance, as small impedance mismatches (that can dynamically develop between systems) could drastically degrade the entire federation performance. Recent proliferation of Software Defined Everything (SDX) technologies combined with containerization frameworks provide custom instruments that can monitor and collect critical measurements at various levels to support diagnoses and performance optimization; but their data too enormous for human operators and analysts to process and generate decisions. Machine Learning (ML) methods that extract critical parameters, relationships and trends from the data offer general solutions. Artificial Intelligence (AI) and ML methods must be custom-developed for these problems based on solid, rigorous foundations, since black-box approaches are often ineffective and unsound.We propose to develop comprehensive AI-Science for the performance of science federations to (i) monitor and control storage, networks, experiments, and computing systems across multiple domains via softwarization layers, at speeds and scales orders of magnitude superior to current practice, (ii) optimally realize and orchestrate complex workflows with high performance by using dynamic state and performance estimation methods, and (iii) aggregate measurements across sites and time to develop infrastructure-level profiles, optimizations and diagnoses using AI-Science based on foundational principles from ML, game theory, and information fusion areas.

Rao, Nageswara↗

MEPHESTO: Modeling Energy-Performance in Heterogeneous SoCs and Their Trade-Offs

Integrated shared memory heterogeneous architectures are pervasive because they satisfy the diverse needs of mobile, autonomous, and edge computing platforms. Although specialized processing units (PUs) that share a unified system memory improve performance and energy efficiency by reducing data movement, they also increase contention for this memory since the PUs interact with each other. Prior work has investigated performance degradation due to memory contention, but few have studied the relationship of power and energy to memory contention. Moreover, a comprehensive solution that models memory contention for kernel placement on contemporary heterogeneous systems on chip (SoCs) in response to energy and performance has been largely unaddressed.This paper presents MEPHESTO, a novel and holistic approach for managing this balance. The authors characterize applications and PUs in terms of two memory contention factors - time factors and power factors - to achieve the desired trade-off between energy and performance for collocated kernel execution on heterogeneous systems. The authors believe that this investigation is the first to combine all of these factors and present a simple knob-based approach that expresses the target trade-off. The approach is evaluated on a diverse integrated shared memory heterogeneous system with a CPU, GPU, and programmable vision accelerator. By using an empirical model for memory contention that provides up to 92% accuracy, the kernel collocation approach can provide a near-optimal ordering and placement based on the user-defined, energy-performance trade-off parameter. Moreover, the dynamic programming-based heuristics provide up to 30% better energy or 20% performance benefits when compared with the greedy approaches commonly employed by previous studies.

Alaul haque monil, Mohammad↗

Development and Performance Evaluation of of Active Insulation Systems using Solid-State Thermal Switches

Traditional building envelopes have passive insulation systems that cannot respond to dynamic changes in the environment. An Active Insulation System (AIS) consists of Active Insulation Materials (AIMs), which dynamically vary the thermal conductivity of the insulation system. Several researchers have evaluated the impact of AIS on building thermal and energy performance by using simulation tools. Up to 70% savings in annual heating and cooling energy and significant reductions in peak demand have been predicted for some climates with wall systems employing AIS. Sensitivity studies have provided requirements for the AIS properties and control schemes that can lead to those savings. However, materials and assembly development have not yet achieved a cost-effective product that achieves the required performance. In this study, we present the process to develop an AIS that we will install in a test hut for their performance evaluation. Minimum performance criteria of the AIS system are developed based on Rmin/Rmax ratio, required time and efficiency to switch states and cost estimate. The next step carried out during this study is creating the concept to meet the requirements, predicting the performance by simulations, developing the experimental setup for bench-scale testing, and finally, constructing a full-scale wall assembly and monitoring the performance when exposed to natural weather conditions. The selected approach uses off-the-shelf products to create a materials system that can switch R-value between R~=1 ft2·°F·h/BTU (0.18 m2·K/W) and R~=7 ft2·°F·h/BTU (1.23 m2·K/W and have a switching time of less than one minute between R-high and R-low.

Iffa, Emishaw↗

NUMERICAL PREDICTIONS OF MEAN PERFORMANCE AND DYNAMIC BEHAVIOR OF A 10 MWe SCO2 COMPRESSOR WITH TEST DATA VALIDATION

High-fidelity aerodynamic analysis has been demonstrated for mean performance and unsteady dynamics in a sCO2 compressor designed by Hanwha Power Systems Americas for a 10 MWe Concentrating Solar Power plant. Simulations were performed with CRUNCH CFD® software tool that was matured to accurately model near critical real fluid effects in sCO2. Pre-test predictions for mean performance were validated with test data collected later. Performance predictions were accurate and captured sensitivity of the efficiency to inlet temperature of CO2 as well as steep drop-off at high flow rates due to condensation in the inlet throat. Detailed analysis was performed to understand the source of these performance losses at near critical conditions. Unsteady dynamic effects in the compressor at off-design conditions were also identified and quantified. In particular a system wide “condensation surge” condition was detected at high flow coefficients that results in large amplitude pulsations with accompanying mass flow fluctuations at low frequencies and has potential to cause damage in closed loop systems.

hosangadi, ashvin↗

Performance Evaluation of AG-1 FC HEPA Filters and Medium in Nuclear Complex Facilities - 20434

High Efficiency Particulate Air (HEPA) filters are credited as the final barrier against the release of radioactive aerosol contamination in nearly every operating U. S. Department of Energy (DOE) and National Nuclear Security Agency (NNSA) nuclear facility. The Institute for Clean Energy Technology (ICET) at Mississippi State University maintains a research program that studies various aspects of these components of containment systems and seeks to answer key questions from across the industry. This programmatic overview will include results from recent and ongoing studies, including a study on filter design and performance envelope, degradation due to aging or fatigue, fire event impact on HEPA filters, and accelerated aging of medium and component parts. ICET has completed a study helping to define the threshold for combined elevated temperature and relative humidity resistance of separator style and separator-less style HEPA filters that are used in DOE complexes. The study provides experimental data that considers elevated temperature, elevated relative humidity (RH), and target differential pressure (dP) in an attempt to gain a better understanding or more comprehensive insight into the operating envelope of different configurations of ASME (American Society for Mechanical Engineers) AG-1 Section FC filters. Test variables including air temperature ranges of 48.88 deg. C, 54.44 deg. C, or 60 deg. C (120, 130, or 140 deg. F); air RH ranges including 60-70%, 80%, or 90+% with initial filter dP of either 497.68 Pa, 746.52 Pa, or 995.36 Pa (2 inches water column (in. w. c.), 3 in. w. c., or 4 in. w. c.) included for full bracketing of each set of conditions. A study examining the effects of aging and fatigue on nuclear grade HEPA filters and medium elucidates the physical properties of media along with testing of new and aged ASME AG-1 HEPA filters. In addition to performing autopsies of the tested, aged filters to help better understand the service life of their performance, newly designed accelerated aging chambers allow new medium to undergo accelerated aging and exposure treatments. Evaluation of degradation in physical properties and functionality requires a high population of aged filters of different ages, designs, manufacturers, and operational histories. The limited availability of this population and the impropriety of looking solely at formulations and components from past years requires experimental design that will provide foresight into future filter performance. This undertaking therefore involves not only properties analysis of aged medium from different operational histories, ages, designs, and manufacturers, but also prescience in analytical goals via accelerated aging studies of newly manufactured media. A more complete understanding of the mechanisms of degradation from past formulations as well as current and future formulations is possible. Accelerated Aging of newly manufactured media utilizes exposure treatments based on the Arrhenius equation to artificially age medium and therefore glimpse into the future. Evaluation of current media properties This testing allows for the comparison of performance and durability of new filters under upset or design basis conditions with aged filters that were in service under ambient conditions and other aged filters retained in storage. Susceptibility of HEPA filters to the effects of combustion byproducts, heat, and water is also being studied in an attempt to gain understanding on the prevention of filter failures during fire events in nuclear facilities. ICET seeks to determine the effect of filter performance due to smoke loading using characterized smoke from variable fuel compositions, geometries, and loads; the smoke capacity of various filters with different burning conditions, heat release rates and transport, as well as mass transport from the air stream will be studied in low flow containment systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaling and performance portability of the particle-in-cell scheme for plasma physics applications through mini-apps targeting exascale architectures

We perform a scaling and performance portability study of the particle-in-cell scheme for plasma physics applications through a set of mini-apps we name "Alpine", which can make use of exascale computing capabilities. The mini-apps are based on Independent Parallel Particle Layer, a framework that is designed around performance portable and dimension independent particles and fields. We benchmark the simulations with varying parameters such as grid resolutions (5123 to 20483) and number of simulation particles (109 to 1011) with the following mini-apps: weak and strong Landau damping, bump-on-tail and two-stream instabilities, and the dynamics of an electron bunch in a charge-neutral Penning trap. We show strong and weak scaling and analyze the performance of different components on several pre-exascale architectures such as Piz-Daint, Cori, Summit and Perlmutter. While the scaling and portability study helps identify the performance critical components of the particle-in-cell scheme in the current state-of-the-art computing architectures, the mini-apps by themselves can be used to develop new algorithms and optimize their high performance implementations targeting exascale architectures.

Muralikrishnan, Sriramkrishnan↗

Performance Portability Evaluation of Fluid-Structure Interaction Simulations on Heterogeneous Platforms

The rapid proliferation of heterogeneous programming languages and multi-vendor hardware has underscored the critical need to evaluate the performance portability of scientific applications. In this work, we present the systematic porting and optimization of a massively parallel fluid-structure interaction code across multiple heterogeneous programming frameworks for deployment on leadership-class supercomputers from major vendors. Our analysis focuses on at-scale performance for simulations involving hundreds of millions of deformable cells, executed on a combination of CPUs and GPUs spanning thousands of nodes on exascale machines. We benchmark the performance of each implementation, highlighting the trade-offs inherent in adopting diverse programming models. Key insights regarding the portability of CUDA on multi-vendor platforms, the superior multi-core CPU performance from SYCL, and architectural considerations on performance optimization are distilled from our experience, offering guidance to other users of high performance computing based on our findings.

Martin, Aristotle [Duke University]↗

Machine Learning-Driven Optimization of Building Enclosures for Moisture Durability and Thermal Performance

The design of moisture-durable building enclosures with low embodied carbon often involves an iterative process of selecting the materials for the specific exposure conditions to meet the performance requirements. While hygrothermal simulations are commonly used to evaluate moisture durability, they often require advanced expertise for proper implementation. Machine learning (ML) provides a promising alternative by streamlining the design process and minimizing the reliance on complex simulations. This study presents a machine learning-based approach for predicting moisture durability in residential wall assemblies. The ML model was trained to estimate the mold index and maximum moisture content of various layers under typical exposure conditions. The model achieved a high predictive accuracy, with a coefficient of determination (R²) exceeding 0.90 when compared to traditional hygrothermal simulations on materials that were not part of training the ML model. Building on these results, the ML model was developed into a practical tool for optimizing wall assembly designs. This tool allows users to automatically optimize material selections based on energy, moisture, and carbon performance criteria. By incorporating multi-objective optimization, the tool identifies configurations that minimize embodied carbon while maintaining moisture safety and code-compliant thermal performance. Additionally, it provides insights into how material choices influence assembly durability, energy efficiency, and carbon reduction. The tool will be implemented in the Building Science Advisor (BSA) to enhance its performance and provide more granularity on the results. This research highlights the potential for ML-driven tools to simplify the design of high-performance building enclosures, offering architects and engineers a faster, more efficient way to balance critical performance factors.

Salonvaara, Mikael [ORNL] (ORCID:0000000318991554)↗

Multi-Split Variable Refrigerant Flow (VRF) System Building Energy Simulations Using Performance Maps

Multi-split variable refrigerant flow (VRF) systems are highly energy-efficient HVAC (heating, ventilation and air conditioning) technologies that connect a single outdoor unit to multiple independent indoor terminal units using a common refrigerant circuit and a variable-speed compressor. Building energy simulations that incorporate VRF systems help model their unique operational characteristics and predict energy consumption in specific building designs. Traditionally, EnergyPlus models these systems by employing multiple sets of performance curves to characterize both individual terminal units and the outdoor unit. However, producing these curves is labor intensive and error prone, and they often do not capture all the key input and output variables. This paper introduces a novel approach that uses multi-dimensional performance maps to model VRF systems in building environments for space cooling. In this approach, performance maps are developed at the component level—separately for the outdoor unit and for each indoor terminal. The new modeling method is validated within EnergyPlus via a Python plug-in that contains a simple solver loop to coordinate the component-level, indoor, and outdoor unit maps. Furthermore, because performance maps can span more variables than traditional performance curves, they offer the opportunity to implement advanced controls, such as enhanced dehumidification and compressor modulation. A VRF air conditioner’s hardware system was modeled using the DOE/ORNL Heat Pump Design Model, which was automated to produce extensive performance maps for both the indoor and outdoor units.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Best practices for photovoltaic performance loss rate calculations

Abstract The performance loss rate (PLR) is a vital parameter for the time-dependent assessment of photovoltaic (PV) system performance and health state. Although this metric can be calculated in a relatively straightforward manner, it is challenging to achieve accurate and reproducible results with low uncertainty. Furthermore, the temporal evolution of PV system performance is usually nonlinear, but in many cases a linear evaluation is preferred as it simplifies the assessment and it is easier to evaluate. As such, the search for a robust and reproducible calculation methodology providing reliable linear PLR values across different types of systems and conditions has been the focus of many research activities in recent years. In this paper, the determination of PV system PLR using different pipelines and approaches is critically evaluated and recommendations for best practices are given. As nonlinear PLR assessments are fairly new, there is no consent on how to calculate reliable values. Several promising nonlinear approaches have been developed recently and are presented as tools to evaluate the PV system performance in great detail. Furthermore, challenges are discussed with respect to the PLR calculation but also opportunities for differentiating individual performance losses from a generic PLR value having the potential of enabling actionable insights for maintenance.

14 SOLAR ENERGY↗

Profiling the BLAST bioinformatics application for load balancing on high-performance computing clusters

Abstract Background The Basic Local Alignment Search Tool (BLAST) is a suite of commonly used algorithms for identifying matches between biological sequences. The user supplies a database file and query file of sequences for BLAST to find identical sequences between the two. The typical millions of database and query sequences make BLAST computationally challenging but also well suited for parallelization on high-performance computing clusters. The efficacy of parallelization depends on the data partitioning, where the optimal data partitioning relies on an accurate performance model. In previous studies, a BLAST job was sped up by 27 times by partitioning the database and query among thousands of processor nodes. However, the optimality of the partitioning method was not studied. Unlike BLAST performance models proposed in the literature that usually have problem size and hardware configuration as the only variables, the execution time of a BLAST job is a function of database size, query size, and hardware capability. In this work, the nucleotide BLAST application BLASTN was profiled using three methods: shell-level profiling with the Unix “time” command, code-level profiling with the built-in “profiler” module, and system-level profiling with the Unix “gprof” program. The runtimes were measured for six node types, using six different database files and 15 query files, on a heterogeneous HPC cluster with 500+ nodes. The empirical measurement data were fitted with quadratic functions to develop performance models that were used to guide the data parallelization for BLASTN jobs. Results Profiling results showed that BLASTN contains more than 34,500 different functions, but a single function, RunMTBySplitDB, takes 99.12% of the total runtime. Among its 53 child functions, five core functions were identified to make up 92.12% of the overall BLASTN runtime. Based on the performance models, static load balancing algorithms can be applied to the BLASTN input data to minimize the runtime of the longest job on an HPC cluster. Four test cases being run on homogeneous and heterogeneous clusters were tested. Experiment results showed that the runtime can be reduced by 81% on a homogeneous cluster and by 20% on a heterogeneous cluster by re-distributing the workload. Discussion Optimal data partitioning can improve BLASTN’s overall runtime 5.4-fold in comparison with dividing the database and query into the same number of fragments. The proposed methodology can be used in the other applications in the BLAST+ suite or any other application as long as source code is available.

59 BASIC BIOLOGICAL SCIENCES↗

Carbon nanofibers (CNFs) dispersed in ultra-high performance concrete (UHPC): Mechanical property, workability and permeability investigation

This paper presents experimental data on the effect of carbon nano-fiber (CNF) dispersion on mechanical behavior, workability, and permeability of ultra-high-performance concrete containing CNF (UHPC-CNF). The addition of CNFs in concrete has been shown to provide improved performance. However, an inhomogeneous distribution of CNFs in the cement matrix can result in no impact or decreased mechanical performance. Due to the van der Waal's forces and hydrophobic surface properties of the CNFs, good dispersion in mix fluids and cement paste is challenging. Experimental studies of UHPC-CNF with different dispersion methods are provided. Further mixing with optimized UHPC paste allowed for the investigation of the optimal dosage of CNFs, impact on porosity, compressive strength, flexural strength, hydration rate, and slump. Scanning electron microscopy (SEM) analysis visually revealed the effect of dispersion. Our results indicate that shear mixing and subsequent ultrasonic dispersion with chemical surfactants can provide a well-dispersion liquid admixture of CNFs resulting in high mechanical performance of UHPC-CNFs composites. The water permeability and chloride resistance of optimized UHPC-CNFs composites were further evaluated with the wicking test and ponding test to reveal improved performance for these properties as well.

36 MATERIALS SCIENCE↗

Implementing a neural network interatomic model with performance portability for emerging exascale architectures

The two main thrusts of computational science are increasingly accurate predictions and faster calculations; to this end, the zeitgeist in molecular dynamics (MD) simulations is pursuing machine learned and data driven interatomic models, e.g. neural network potentials, and novel hardware architectures, e.g. GPUs. Current implementations of neural network potentials are orders of magnitude slower than traditional interatomic models and while looming exascale computing offers the ability to run large, accurate simulations with these models, achieving portable performance for MD with new and varied exascale hardware requires rethinking traditional algorithms, using novel data structures, and library solutions. We re-implement a neural network interatomic model in CabanaMD, an MD proxy application, built on libraries developed for performance portability. Our implementation shows significantly improved thread scaling in this complex kernel as compared to a current LAMMPS implementation, across both strong and weak scaling. Our single-source solution enables simulations up to 20 million atoms on a single CPU node and 4 million atoms with improved performance on a single GPU. Furthermore, we also explore parallelism and data layout choices (using flexible data structures called AoSoAs) and their effect on performance, seeing up to ~50% and ~5% improvements in performance on a GPU by choosing the right level of parallelism and data layout respectively.

97 MATHEMATICS AND COMPUTING↗

A parallel and performance portable implementation of a full-field crystal plasticity model

We have developed a parallel implementation of an Elasto-Viscoplastic Fast Fourier Transform-based (EVPFFT) micromechanical solver to enable computationally efficient crystal plasticity modeling for polycrystalline materials. Our primary focus lies in achieving performance portability, allowing a single EVPFFT implementation to run optimally on various homogeneous architectures, including multi-core Central Processing Units (CPUs), as well as on heterogeneous computer architectures comprising multi-core CPUs and Graphics Processing Units (GPUs) from different vendors. To accomplish this goal, we have leveraged MATAR, a C++ software library that simplifies the creation and utilization of multidimensional dense or sparse matrix and array data structures. These data structures are designed to be portable across diverse architectures through the use of Kokkos, a performance-portable library. Additionally, we have employed the Message Passing Interface (MPI) to efficiently distribute the computational workload among processors. The heFFTe (Highly Efficient FFT for Exascale) library is used to facilitate the performance portability of the fast Fourier transforms (FFTs) computation. The computational performance of EVPFFT is evaluated and presented in terms of parallel scalability and simulation runtime on different high-performance computing (HPC) architectures. As a result, the utility of the developed framework to efficiently simulate the micro-mechanical fields in polycrystalline microstructures in engineering applications is discussed.

36 MATERIALS SCIENCE↗

Pavement condition and climatic data in southeast Texas: A dataset for evaluating flood impacts on pavement performance

Effective pavement maintenance is essential for economic stability, optimal network performance, and roadway safety. Achieving this requires thorough evaluation of pavement conditions, including structural integrity, surface roughness, and distress characteristics. Pavement performance indicators play a critical role in influencing vehicle safety and ride quality. Recent advances have emphasized the use of data-driven modeling to anticipate pavement behavior, with the goal of optimizing resource allocation and refining Maintenance and Rehabilitation (M&R) strategies through accurate condition assessment. A foundational requirement for these modeling efforts is the availability of standardized, high-quality datasets that can support robust and reproducible infrastructure analysis. This data article presents a comprehensive dataset assembled to facilitate pavement performance prediction, with a geographic focus on Southeast Texas, particularly the flood-vulnerable area of Beaumont. The dataset encompasses pavement and traffic attributes, meteorological records, flood simulation outputs, ground deformation measurements, and topographic indices, enabling detailed examination of both load-associated and non-load-associated degradation mechanisms. Data preprocessing was performed using ArcGIS Pro, Microsoft Excel, and Python to ensure consistency and usability in data-driven modeling applications, including machine learning workflows. Key contributions of this dataset include its utility in analyzing the climatic and environmental factors affecting pavement conditions, identifying critical predictive features, and enabling in-depth correlation analysis across diverse variables. By filling existing gaps in input variable selection resources, this dataset supports the development of predictive tools for estimating future maintenance demand and enhancing the resilience of pavement networks in flood-impacted areas. The resource highlights the importance of standardized datasets for advancing pavement management practices and provides a robust foundation for ongoing infrastructure performance modeling.

42 ENGINEERING↗

Nature-inspired lotus-shaped fins combined with hybrid nanoparticles and metal foam for high-performance latent heat thermal energy storage

Latent heat thermal energy storage (LHTES) systems play a critical role in renewable energy integration by providing high energy density and nearly isothermal operation during phase transitions. However, their performance is often limited by slow melting/charging rates, which motivates the search for enhanced heat transfer designs. This study investigates the melting behavior of RT-82 phase change material (PCM) using novel lotus-shaped fins combined with copper metal foam and conductive graphene nanoparticles and carbon nanotubes. A two-dimensional enthalpy-porosity model in ANSYS Fluent was developed to simulate the charging/melting process, capturing non-thermal equilibrium between the foam and PCM/nano-PCM. In this study, effects of fin geometry, nanoparticle concentration, and foam porosity on melting dynamics and cost-performance trade-offs were investigated. Results showed that natural convection accelerated melting by ~12% compared to conduction-only scenarios. Optimized lotus-shaped fins with higher fin density (T3F4 and T3F10) achieved up to 63% faster melting relative to sparse configurations. Graphene nanoparticles improved thermal conductivity, with a 6% volume fraction, by reducing melting time by ~6.9%, while their combination with 75% porosity foam achieved a maximum reduction in the melting time of ~51% compared to pure PCM. Cost-performance analysis identified T3F4 as the most balanced design, offering rapid thermal response without excessive material costs, while moderate-density designs like T3S6 provided economical alternatives with acceptable performance. These results highlight the performance enhancement that can be achieved by integrating bio-inspired fins, nanoparticles, and foams, into compact and efficient LHTES for solar heating, building thermal management, and industrial waste-heat recovery applications.

25 ENERGY STORAGE↗