Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Outages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A sequential Attacker-Defender game for distribution systems resilience enhancement against extreme weather events

Improving distribution system resilience against frequent extreme weather events is important for reliable power system operations. Especially when dealing with events such as hurricanes that have short-term predictions, proactive pre-event preparedness plays a vital role in system resilience performance. In this paper, we propose a novel approach to construct pre-event resource allocation plans for system operators to cope with upcoming threats through a sequential attacker-defender game framework. The sequential attacker-defender game is designed to model the interaction between the extreme weather and the system operator. In each round of the game, the attacker and the defender sequentially update their current strategies by accounting for the opponent’s action set. The attacker model is formulated as a bi-level problem to identify the severe outage scenarios, and the defender model is formulated as a two-stage optimization problem to determine the allocation of restoration resources including mobile responsive resources and repair crews. Two scale-reduction strategies are proposed to ensure the scalability of the game scheme. Finally, case studies on the IEEE 33-bus and a 7149-node practical utility system validate the effectiveness of the proposed sequential game and the efficiency of the scale-reduction strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Projected network performance for next generation aerosol monitoring systems

Aerosol monitoring for radioactivity is a mature and proven technology. However, by improving key specifications of aerosol monitoring equipment, more samples per day can be collected and analyzed with the same minimum detectable concentrations as current systems. This work models hypothetical releases of 140 Ba and 131 I over a range of magnitudes corresponding to the inventory produced from the fission of about 100 g to 1 kiloton TNT-equivalent of 235 U. The releases occur over an entire year to incorporate the natural variability in atmospheric transport. Sampling equipment located at the 79 locations for radionuclide stations identified in the Comprehensive Nuclear-Test-Ban Treaty (CTBT) for the International Monitoring System are used to determine the detections of the individual releases. Alternative collection schemes in next generation equipment that collect 2, 3, or 4 samples per day, rather than the current 1 sample per day, would result in detections in many more samples at more stations with detections for a given release level. The authors posit that next generation equipment will result in increased network resilience to outages and improved source-location capability for lower yield source releases. The application of dual-detector and coincidence measurements to these systems would significantly boost sensitivity for some isotopes and would further enhance the monitoring capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using artificial intelligence to detect human errors in nuclear power plants: A case in operation and maintenance

Human error (HE) is an important concern in safety-critical systems such as nuclear power plants (NPPs). HE has played a role in many accidents and outage incidents in NPPs. Despite the increased automation in NPPs, HE remains unavoidable. Hence, the need for HE detection is as important as HE prevention efforts. In NPPs, HE is rather rare. Hence, anomaly detection, a widely used machine learning technique for detecting rare anomalous instances, can be repurposed to detect potential HE. In this study, we develop an unsupervised anomaly detection technique based on generative adversarial networks (GANs) to detect anomalies in manually collected surveillance data in NPPs. More specifically, our GAN is trained to detect mismatches between automatically recorded sensor data and manually collected surveillance data, and hence, identify anomalous instances that can be attributed to HE. We test our GAN on both a real-world dataset and an external dataset obtained from a testbed, and we benchmark our results against state-of-the-art unsupervised anomaly detection algorithms, including one-class support vector machine and isolation forest. Our results show that the proposed GAN provides improved anomaly detection performance. Our study is promising for the future development of artificial intelligence based HE detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full core LOCA safety analysis for a PWR containing high burnup fuel

For economic reasons, the US nuclear industry is renewing efforts to build a technical basis to extend peak rod average burnup limits above the current regulatory burnup limit of 62 GWd/MTU. The primary driver of these efforts is to economically increase pressurized water reactor (PWR) cycle lengths to 24 months, reduce the number of fresh fuel assemblies, increase time online, thereby reducing number of outages and their associated cost, higher fuel utilization, and possibly reduce core design constraints. In order for US nuclear utilities to leverage these economic efficiencies, the US Nuclear Regulatory Commission (NRC) will likely require nuclear power plants (NPPs) to analyze a number of potential operational occurrences and their potential consequences with each new core design prior to resuming normal operation. Potential operational occurrences can be divided into three primary regimes: (1) normal operation, (2) anticipated operation occurrences (AOOs), and (3) design basis accidents (DBAs). Normal plant operation is an operating regime in which the plant operates within specified operational limits until the end of the cycle, whereas AOOs are events that result in the NPP deviating outside the normal operating regime. A key attribute of an AOO is that the occurrence should be expected. However, by definition, the occurrence of an AOO does not result in significant impact to critical safety functions. The last potential operational occurrence is a DBA. From the fuel performance point-of-view, DBAs can be subdivided into two bounding categories: (1) loss of coolant accidents (LOCAs), and (2) reactivity insertion accidents (RIAs). Unlike AOOs, DBAs may result in fuel rod failure. The NRC imposes fundamental acceptance criteria to minimize radiological consequences to the public and onsite staff. Furthermore, safety criteria are typically linked to the fulfillment of other acceptance criteria related to reactor safety equipment designed to mitigate DBAs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Core design and performance of the Westinghouse lead fast reactor with UO 2 and MOX configurations

For this work, Westinghouse partnered with Argonne National Laboratory to design, model and optimize UO 2 - and MOX-fueled core designs for a medium size (950 MWt) Lead Fast Reactor that was pursued by Westinghouse. Using Argonne’s suite of reactor analysis codes together with Westinghouse fuel cost economic models, thousands of candidate cores were considered to achieve the economics-optimized cores presented in this paper. This optimization process considered detailed reactor physics, fuel performance, transient performance, and fuel economics models. The reactor performance of the resulting optimized UO 2 - and MOX-fueled core designs are described and compared in this paper. Both cores show fuel performance and transient behavior that is considered acceptable for the optimization presented herein, while further testing campaigns on material performance in high-temperature liquid lead will be required to confirm acceptability at the operating conditions chosen. A multi-batch strategy was selected for the UO 2 core for best fuel utilization with minimum fuel inventory costs. A single-batch fuel management was instead selected for the MOX core to maximize cycle length and minimize the impact of the longer refueling outage resulting from the higher decay heat of the discharged MOX fuel relative to the discharged UO 2 fuel, requiring a longer cooling time before dry-lift of discharged fuel could take place.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Looking Beyond Bill Savings to Equity in Renewable Energy Microgrid Deployment

Microgrids powered by renewable energy can provide backup power to critical infrastructure during grid outages. These systems can also play an important role in advancing energy justice by providing economic, environmental, health, and resilience benefits for underserved communities. The value of microgrids is often measured by the economic savings and resilience provided, but there are other energy justice factors that should be considered. This paper describes a methodology for quantifying broader costs and benefits including utility bill savings, value of resilience, social cost of carbon, public health costs, and jobs associated with the construction and operation of microgrids. We evaluate these factors at three case study sites and find that including energy justice values in the cost-benefit analysis of microgrids can change investment decisions. When climate, health, resilience, and job creation are considered, cost-optimal microgrids include more renewable generation, leading to a 52-82% reduction in emissions and diesel fuel use. The net present values of the microgrids grow from negative $626,000-843,000 in the diesel only case to $10-16 million in the hybrid microgrid case and $12-19 million in the renewable microgrid case, indicating potential for greater microgrid deployment if energy justice values are incorporated in decision making. However, we also see large increases in capital expenses, which could limit deployment unless accompanied by innovative financing measures. These findings may be useful to communities as they seek to strengthen resilience to natural disasters while also improving public health, meeting climate goals, and providing economic opportunity for residents.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-Efficient Strategies for Probabilistic Voltage Envelopes under Network Contingencies

This work presents an efficient data-driven method to construct probabilistic voltage envelopes (PVE) using power flow learning in grids with network contingencies. First, a network-aware Gaussian process (GP) termed Vertex-Degree Kernel (VDK-GP), developed in prior work, is used to estimate voltage–power functions for a few network configurations. The paper introduces a novel multi-task vertex degree kernel (MT-VDK) that amalgamates the learned VDK-GPs to determine power flows for unseen networks, with a significant reduction in the computational complexity and hyperparameter requirements compared to alternate approaches. Simulations on the IEEE 30-Bus network demonstrate the retention and transfer of power flow knowledge in both N-1 and N-2 contingency scenarios. The MT-VDK-GP approach achieves over 50 % reduction in mean prediction error for novel N-1 contingency network configurations in low training data regimes (50–250 samples) over VDK-GP. Additionally, MT-VDK-GP outperforms a hyper-parameter based transfer learning approach in over 75 % of N-2 contingency network structures, even without historical N-2 outage data. Furthermore, the proposed method demonstrates the ability to achieve PVEs using sixteen times fewer power flow solutions compared to Monte-Carlo sampling-based methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ambient energy for buildings: Beyond energy efficiency

The following Key Messages comprise the salient findings of this study: 1. Ambient energy (from sun, air, ground, and sky) can heat and cool buildings; provide hot water, ventilation and daylighting; dry clothes; and cook food. These services account for about three-quarters of building energy consumption and a third of total US demand. Biophilic design (direct and indirect connections with nature) is an intrinsic adjunct to ambient energy systems, and improves wellness and human performance. 2. The current strategy of electrification and energy efficiency for buildings will not meet our climate goals, because the transition to an all-renewable electric grid is too slow. Widespread adoption of ambient energy is needed. Solar-heated buildings also flatten the seasonal demand for electricity compared to all-electric buildings, reducing required production capacity and long-term energy storage. In addition, ambient-conditioned buildings improve resilience by remaining livable during power outages. 3. National policies, incentives, and marketing should be enacted to promote ambient energy use. Federal administrative priorities should reflect the importance of ambient energy for buildings. Use of ambient energy should be encouraged through existing and new building codes and standards. 4. Ambient energy system design tools are needed for architects, engineers, builders, building scientists, realtors, appraisers, and consumers. PVWatts is used over 100 million times per year for photovoltaic system design. A similar, simple, and accessible tool for ambient design is crucial. 5. Training on ambient energy is needed throughout secondary, post-secondary, and continuing education for workforce development. Currently, only about 10% of colleges teach courses on passive heating and cooling systems. 6. Ambient-conditioned buildings should be demonstrated in all US climate zones. Performance should be monitored and reported, with quantitative case studies made widely available. 7. While current technology is sufficient to build high-performance ambient buildings now, research is needed to develop new technologies to harness ambient energy more effectively and more economically. Such advancements will facilitate adoption of ambient energy technologies in a wider range of buildings, including retrofits. Examples include windows with much lower thermal losses, use of the building shell as thermal storage, alternative light-weight thermal storage systems, sky radiation cooling systems, automated controls for solar gains and passive cooling, and ground coupling.

14 SOLAR ENERGY↗

Could on-site fuel storage economically reduce power plant-gas grid dependence in pipeline constrained areas like New England?

In the Northeastern United States, natural gas supply constraints have led to periods when gas shortages have caused up to a quarter of all unscheduled power plant outages. Dual fuel oil/gas generators or local gas storage might mitigate gas supply shortages. We use historical power plant operational and availability data to develop a supply curve of the costs required for generators to mitigate fuel shortage failures in New England. Based on 2012–2018 data, we find that the historical fuel shortages at approximately 2 GW worth of gas-fired capacity could be mitigated using on-site fuel storage. For comparison, New England’s average reserve margin was 1.7–2.8 GW over our sample period. Oil dual fuel plants would recoup their investment if compensated with a reliability adder of $\$ 3-7$/MWh during their normal operations, while $\$ 7-16$/MWh would incentivize using onsite, compressed natural gas storage. We estimate that the capital expenses associated with the fuel storage options would be less expensive than installing battery backup for resource adequacy at current battery prices.

03 NATURAL GAS↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

Engineering bimetallic interfaces and revealing the mechanism for carbon dioxide electroreduction to C 3+ liquid chemicals

Reduction reaction of CO 2 (CO 2 RR) to liquid C 3+ chemicals is a net-zero-carbon process and can increase local resiliency to power outages and fuel consumption. The mechanism and the catalyst design rules of CO 2 RR-to-C 3+ are unknown. Engineering bimetallic interface (e.g., Pd/Au) to tune the intermediate adsorption is promising for promoting C 3+ formation. Our density functional theory (DFT) calculations find that *CH 2 could be the key intermediate and C 1 -CH 2 coupling could be the rate-limiting step to generate C 3+ . High CO surface coverages can promote the bimetallic interfacial sites, lower the energetics of the C 1 -CH 2 coupling step, and enhance the C 3+ formation. We further construct a volcano plot of C 1 -CH 2 kinetics as a function of the binding strength of key intermediate *CH 2 via engineering the d-band center of the interfacial site. Our findings could guide the rational design of bimetallic interfaces and their near-surface microenvironment for enhancing CO 2 RR-to-C 3+ .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economic Analysis of Condition-Monitoring-Based Predictive Maintenance in Power Plants under Market Elasticity

Condition-monitoring-based predictive maintenance can increase the power plant availability by preventing forced outages. However, the actual on-stream time depends on market elasticity and dynamics, which are affected by cost and penetration of other power generation technologies. This paper develops a systematic approach for the economic analysis of investment in condition monitoring technologies with due consideration of market elasticity. Focus is on corrosion monitoring in coal-fired power plants (CFFPs) since corrosion in high-temperature coal-fired boilers is a leading cause of equipment failure. Investment in sensor networks for measuring corrosion and operating conditions like metal temperature and concentrations of O 2 and SO 2 is investigated. The unscented Kalman filter is used to estimate corrosion in the waterwall section of the boiler under multiple sensor networks. Electricity produced by CFPPs in the future in the U.S. due to changes in availability under market elasticity is studied. Sensitivity of the incremental net present value to factors like the number, type, and cost of sensors is analyzed.

Electrochemistry↗

Synchronization in electric power networks with inherent heterogeneity up to 100% inverter-based renewable generation

The synchronized operation of power generators is the foundation of electric power network stability and a key to the prevention of undesired power outages and blackouts. Here, we derive the conditions that guarantee synchronization in power networks with inherent generator heterogeneity when subjected to small perturbations, and perform a parametric sensitivity analysis to understand synchronization with varied types of generators. As inverter-based resources, which are the primary interfacing technology for many renewable sources of energy, have supplanted synchronous generators in ever growing numbers, the center of attention on associated integration challenges have resided primarily on the role of declining system inertia. Our results instead highlight the critical role of generator damping in achieving a stable state of synchronization. Additionally, we report the feasibility of operating interconnected electric grids with up to 100% power contribution from inverter-based renewable generation technologies. Our study has important implications as it sets the basis for the development of advanced control architectures and grid optimization methods that ensure synchronization and further pave the path towards the decarbonization of the electric power sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sustainable urban transformations based on integrated microgrid designs

The impacts of natural hazards on infrastructure, enhanced by climate change, are increasingly more severe emphasizing the necessity of resilient energy grids. Microgrids, tailored energy systems for specific neighbourhoods and districts, play a pivotal role in sustaining energy supply during main grid outages. These solutions not only mitigate economic losses and well-being disruptions against escalating hazards but also enhance city resilience in alignment with Sustainable Development Goal (SDG) 11. However, disregarding socioeconomic factors in defining microgrid boundaries risks perpetuating inequalities and impeding progress towards other SDG 11 targets, including fair democratic participation. Our approach integrates social and technical indicators to bolster urban microgrid planning. Through a case study in a US county, we illustrate how integrated microgrid planning effectively intertwines urban resilience, well-being and equity while promoting sustainable development. This study underscores the importance of integrated microgrid planning for sustainable and resilient urban transformation amid environmental and societal challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wildfire and power grid nexus in a changing climate

Global wildfire events have had increasingly severe impacts in recent years, particularly in the western USA, driven by extreme fire-weather conditions, fuel accumulation and multiple ignition sources. Wildfires sparked by power lines tend to be larger and more destructive, as they often occur during high winds, which accelerate the spread of fires. Moreover, efforts to contain wildfires frequently result in power outages, causing considerable economic disruption. Here, in this Review, we examine wildfire risks related to power-line-induced ignitions, infrastructure damage, climate-induced environmental impacts, grid operational risks, real-time grid management risks, vegetation management risks, and financial and funding risks in the context of a changing climate and their interdependence with power grid infrastructures. We then explore the resilience of power grids under wildfire threats, looking at risk analysis, prediction and mitigation strategies. The Review also shares practical insights and experiences in the USA to inform researchers, policymakers and industry professionals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Microgrid Scheduling With Chance‐Constrained Resilience Consideration

Traditionally, it is assumed that microgrids transition seamlessly from grid‐connected operation to islanded mode in the event of sudden main grid outages. In reality, the islanding process, especially unintentional islanding, is rarely seamless. Instead, it is subject to voltage and frequency fluctuations caused by the instantaneous disconnection of the point of common coupling (PCC) switch, variations in loads and renewable generation output and even the protection tripping of distributed energy resources (DERs). To mitigate these fluctuations and facilitate a smooth islanding process, we propose a stochastic microgrid scheduling model that incorporates chance‐constrained resilience measures. Specifically, the resilience measure is defined as the probability of successful islanding (PSI), that is, the probability that a microgrid can mitigate the generation‐demand imbalance caused by the disconnection of the PCC switch, variations in load and renewable generation and DER tripping. This measure is modelled using chance constraints. Unlike existing reliability and resilience indices, which typically neglect the possibility of microgrid/DER failure under extreme events and assume their survival while primarily focussing on reducing impact duration or magnitude, the proposed PSI‐based framework explicitly addresses microgrid and DER survival during the islanding transition. The formulated nonlinear chance constraints are approximated using a multiinterval approach and equivalently represented as a mixed‐integer linear programming (MILP) formulation. Case study results validate the proposed method, showing that the PSI estimation error is reduced to less than 8%, compared to approximately 28% with existing methods. Various sensitivity analyses on the DER tripping rate and PSI settings were performed to validate the robustness of the proposed method. In particular, the necessity of accounting for DER tripping in the PSI calculation was demonstrated.

chance constrained optimization↗

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗