Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Metrology of IXO Mirror Segments

For future x-ray astrophysics mission that demands optics with large throughput and excellent angular resolution, many telescope concepts build around assembling thin mirror segments in a Wolter I geometry, such as that originally proposed for the International X-ray Observatory. The arc-second resolution requirement posts unique challenges not just for fabrication, mounting but also for metrology of these mirror segments. In this paper, we shall discuss the metrology of these segments using normal incidence metrological method with interferometers and null lenses. We present results of the calibration of the metrology systems we are currently using, discuss their accuracy and address the precision in measuring near-cylindrical mirror segments and the stability of the measurements.

Chan, Kai-Wing↗

Estimation of Cyclic Error Due to Scattering in the Internal OPD Metrology of the Space Interferometry Mission

A common-path laser heterodyne interferometer capable of measuring the internal optical path difference (OPD) with accuracy of the order of 10 pm was demonstrated at JPL. To achieve this accuracy, the relative power received by the detector that is contributed by the scattering of light at the optical surfaces should be less than -97 dB. A method has been developed to estimate the cyclic error caused by the scattering of the optical surfaces. The result of the analysis is presented.

scattering↗

Multivalent optical cycling centers: towards control of polyatomics with multi-electron degrees of freedom

Optical control of polyatomic molecules promises new opportunities in precision metrology and fundamental chemistry, as well as quantum information and many-body science. Contemporary experimental and theoretical efforts have mostly focused on cycling photons via excitation of a single electron localized to an alkaline earth (group 2)-like metal center. In this paper, we consider pathways towards optical cycling in polyatomic molecules with multi-electron degrees of freedom, which arise from two or more cycling electrons localized to p-block post-transition metal and metalloid (group 13, 14, and 15) centers. Here, we characterize the electronic structure and rovibrational branching of several prototypical candidates using ab initio quantum chemical methods. Despite increased internal complexity and challenging design parameters, we find several molecules possessing quasi-closed photon cycling schemes with highly diagonal, visible and near-infrared transitions. Furthermore, we identify new heuristics for engineering optically controllable and laser-coolable polyatomic molecules with multi-electron cycling centers. Our results help elucidate the interplay between hybridization, repulsion, and ionicity in optically active species and provide new directions for using polyatomic molecules with complex electronic structure as a resource for quantum science and measurement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Results from SIM's Thermo-Opto-Mechanical (TOM3) Testbed

Future space-based optical interferometers, such as the Space Interferometer Mission Planet Quest (SIM), require thermal stability of the optical wavefront to the level of picometers in order to produce astrometric data at the micro-arc-second level. In SIM, the internal path of the interferometer will be measured with a small metrology beam whereas the starlight fringe position is estimated from a large concentric annular beam. To achieve the micro-arc-second observation goal for SIM, it is necessary to maintain the optical path difference between the central and the outer annulus portions of the wavefront of the front-end telescope optics to a few tens of picometers. The Thermo-Opto-Mecha nical testbed (TOM3) was developed at the Jet Propulsion Laboratory to measure thermally induced optical deformations of a full-size flight-like beam compressor and siderostat, the two largest optics on SIM, in flight-like thermal environments. A Common Path Heterodyne Interferometer (COPHI) developed at JPL was used for the fine optical path difference measurement as the metrology sensor. The system was integrated inside a large vacuum chamber in order to mitigate the atmospheric and thermal disturbances. The siderostat was installed in a temperature-controlled thermal shroud inside the vacuum chamber, creating a flight-like thermal environment. Detailed thermal and structural models of the test articles (siderostat and compressor) were also developed for model prediction and correlation of the thermal deformations. Experimental data shows SIM required thermal stability of the test articles and good agreement with the model predictions.

interferometry↗

Precise Determination of the Zero-Gravity Surface Figure of a Mirror without Gravity-Sag Modeling

The zero-gravity surface figure of optics used in spaceborne astronomical instruments must be known to high accuracy, but earthbound metrology is typically corrupted by gravity sag. Generally, inference of the zero-gravity surface figure from a measurement made under normal gravity requires finite-element analysis (FEA), and for accurate results the mount forces must be well characterized. We describe how to infer the zero-gravity surface figure very precisely using the alternative classical technique of averaging pairs of measurements made with the direction of gravity reversed. We show that mount forces as well as gravity must be reversed between the two measurements and discuss how the St. Venant principle determines when a reversed mount force may be considered to be applied at the same place in the two orientations. Our approach requires no finite-element modeling and no detailed knowledge of mount forces other than the fact that they reverse and are applied at the same point in each orientation. If mount schemes are suitably chosen, zero-gravity optical surfaces may be inferred much more simply and more accurately than with FEA.

measurements↗

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A↗

Spin Squeezing with Itinerant Magnetic Dipoles

Entanglement can improve the measurement precision of quantum sensors beyond the shot noise limit. Neutral atoms, the basis of some of the most precise and accurate optical clocks and interferometers, do not naturally exhibit the all-to-all interactions traditionally used to generate such entangled states. On the other hand, these systems exhibit exceedingly high degrees of experimental control over parameters such as temperature, spatial entropy, and itinerancy. In this work, we investigate spin squeezing in a highly coherent itinerant system of neutral atoms with magnetic dipole-dipole interactions. We achieve 7.1 dB of metrologically useful squeezing using finite-range spin-exchange interactions in an erbium quantum gas microscope, and we demonstrate that introducing atomic motion, realizing a dipolar 𝑡−𝐽 model, protects the spin sector coherence at low fillings, significantly improving the achievable spin squeezing in a 2D dipolar system. This work’s protocol can be implemented with most neutral atoms, opening the door to quantum-enhanced metrology in other itinerant dipolar systems, such as molecules or optical lattice clocks, and serves as a novel method for studying itinerant quantum magnetism with long-range interactions.

Atomic, optical & lattice clocks↗

Degradation of Ta 2 O 5 / SiO 2 dielectric cavity mirrors in ultra-high vacuum

In order for optical cavities to enable strong light-matter interactions for quantum metrology, networking, and scalability in quantum computing systems, their mirrors must have minimal losses. However, high-finesse dielectric cavity mirrors can degrade in ultra-high vacuum (UHV), increasing the challenges of upgrading to cavity-coupled quantum systems. We observe the optical degradation of high-finesse dielectric optical cavity mirrors after high-temperature UHV bake in the form of a substantial increase in surface roughness. We provide an explanation of the degradation through atomic force microscopy (AFM), X-ray fluorescence (XRF), selective wet etching, and optical measurements. We find the degradation is explained by oxygen reduction in Ta 2 O 5 followed by growth of tantalum sub-oxide defects with height to width aspect ratios near ten. We discuss the dependence of mirror loss on surface roughness and finally give recommendations to avoid degradation to allow for quick adoption of cavity-coupled systems.

Optics↗

Model validation of SIM external metrology at the sub-nanometer level

In order to achieve micro-arcsecond astrometry, SIM must make measurements of various optical path lengths at the picometer level. In this regime of precision, nearly every simplifying assumption in optics must be reexamined as a potential source of systematic error. SIM makes extensive use of physics-based models to predict the form and level of systematic errors affecting instrument performance. Since many of the modeling areas represent new frontiers in optical modeling, the validation of these physical models is a significant challenge that SIM must meet. In the case of the external metrology truss, the model must account for the imperfections in the corner cubes as well as the distance measuring interferometers ("beam launchers"). This model is being validated using the Kite testbed, a 2-D metrology truss with picometer-level accuracy in displacement measurements. We present the model and the results of the model validation tests on the Kite testbed.

Kuan, Gary M.↗

Wavefront Control and Image Restoration with Less Computing

PseudoDiversity is a method of recovering the wavefront in a sparse- or segmented- aperture optical system typified by an interferometer or a telescope equipped with an adaptive primary mirror consisting of controllably slightly moveable segments. (PseudoDiversity should not be confused with a radio-antenna-arraying method called pseudodiversity.) As in the cases of other wavefront- recovery methods, the streams of wavefront data generated by means of PseudoDiversity are used as feedback signals for controlling electromechanical actuators of the various segments so as to correct wavefront errors and thereby, for example, obtain a clearer, steadier image of a distant object in the presence of atmospheric turbulence. There are numerous potential applications in astronomy, remote sensing from aircraft and spacecraft, targeting missiles, sighting military targets, and medical imaging (including microscopy) through such intervening media as cells or water. In comparison with prior wavefront-recovery methods used in adaptive optics, PseudoDiversity involves considerably simpler equipment and procedures and less computation. For PseudoDiversity, there is no need to install separate metrological equipment or to use any optomechanical components beyond those that are already parts of the optical system to which the method is applied. In Pseudo- Diversity, the actuators of a subset of the segments or subapertures are driven to make the segments dither in the piston, tilt, and tip degrees of freedom. Each aperture is dithered at a unique frequency at an amplitude of a half wavelength of light. During the dithering, images on the focal plane are detected and digitized at a rate of at least four samples per dither period. In the processing of the image samples, the use of different dither frequencies makes it possible to determine the separate effects of the various dithered segments or apertures. The digitized image-detector outputs are processed in the spatial-frequency (Fourier-transform) domain to obtain measures of the piston, tip, and tilt errors over each segment or subaperture. Once these measures are known, they are fed back to the actuators to correct the errors. In addition, measures of errors that remain after correction by use of the actuators are further utilized in an algorithm in which the image is phase-corrected in the spatial-frequency domain and then transformed back to the spatial domain at each time step and summed with the images from all previous time steps to obtain a final image having a greater signal-to-noise ratio (and, hence, a visual quality) higher than would otherwise be attainable.

Lyon, Richard G.↗

Fabrication of the first pair of optics for the Advanced X-ray Astrophysics Facility (AXAF)

The first two mirrors for the Advanced X-Ray Astrophysics Facility (AXAF) have been successfully fabricated and tested. The methodology developed has demonstrated figure convergence rates previously unseen on large area, precision optics. These results were based on developing a unified systems approach to fabrication and testing aided by the extensive use of analytical models. This paper presents a summary of the optic requirements, an overview of the fabrication process, the metrology used, and a summary of the results.

Reid, P. B.↗

Metrology and Alignment of Light Weight Grazing Incidence X-Ray Mirrors

Metrology and alignment of light weight X-ray optics have been a challenge for two reasons: (1) that the intrinsic mirror quality and distortions caused by handling can not be easily separated, and (2) the diffraction limits of the visible light become a severe problem at the order of one arc-minute. Traditional methods of using a normal incident pencil or small parallel beam which monitors a tiny fraction of the mirror in question at a given time can not adequately monitor those distortions. We are developing a normal incidence setup that monitors a large fraction, if not the whole, of the mirror at any given time. It will allow us to align thin X-ray mirrors to-an accuracy of a few arc seconds or to a limit dominated by the mirror intrinsic quality.

Zhang, William↗

Measurement of the Non-common Vertex Error of a Double Corner Cube

The Space Interferometry Mission (SIM) requires the control of the optical path of each interferometer with picometer accuracy. Laser metrology gauges are used to measure the path lengths to the fiiducial corner cubes at the siderostats. Due to the geometry of SIM a single corner cube does not have sufficient acceptance angle to work with all the gauges. Therefore SIM employs a double corner cube. Current fabrication methods are in fact not capable of producing such a double corner cube with vertices having sufficient commonality. The plan for SIM is to measure the non-commonalty of the vertices and correct for the error in orbit. SIM requires that the non-common vertex error (NCVE) of the double corner cube to be less than 6 (mu)m. The required accuracy for the knowledge of the NCVE is less than 1 (mu)m. This paper explains a method of measuring non-common vertices of a brassboard double corner cube with sub-micron accuracy. The results of such a measurement will be presented.

Space Interferometry Mission (SIM)↗

Spin squeezing in an ensemble of nitrogen–vacancy centres in diamond

Spin-squeezed states provide a seminal example of how the structure of quantum mechanical correlations can be controlled to produce metrologically useful entanglement. These squeezed states have been demonstrated in a wide variety of quantum systems ranging from atoms in optical cavities to trapped ion crystals. By contrast, despite their numerous advantages as practical sensors, spin ensembles in solid-state materials have yet to be controlled with sufficient precision to generate targeted entanglement such as spin squeezing. Here we report the experimental demonstration of spin squeezing in a solid-state spin system. Our experiments are performed on a strongly interacting ensemble of nitrogen–vacancy colour centres in diamond at room temperature, and squeezing (−0.50 ± 0.13 dB) below the noise of uncorrelated spins is generated by the native magnetic dipole–dipole interaction between nitrogen–vacancy centres. To generate and detect squeezing in a solid-state spin system, we overcome several challenges. First, we develop an approach, using interaction-enabled noise spectroscopy, to characterize the quantum projection noise in our system without directly resolving the spin probability distribution. Second, noting that the random positioning of spin defects severely limits the generation of spin squeezing, we implement a pair of strategies aimed at isolating the dynamics of a relatively ordered sub-ensemble of nitrogen–vacancy centres. Furthermore, our results open the door to entanglement-enhanced metrology using macroscopic ensembles of optically active spins in solids.

Atomic and molecular physics↗

Capability Improvements at Marshall Space Flight Center's X-Ray and Cryogenic Facility

The X-Ray & Cryogenic Facility (XRCF) at Marshall Space Flight Center is the world’s largest x-ray optic calibration facility and NASA’s premier cryogenic optical test facility. Built specifically to calibrate the Chandra telescope, the facility contributed to several other x-ray missions until 2005 when it became dedicated to normal incidence optical testing at cryogenic temperatures. Recently the facility’s x-ray test capability has been returned to service and updated. New beam monitors, focal plane detectors, and test article and instrument positioning systems have been added. The x-ray data acquisition system has been updated. A real-time position monitoring metrology system is being developed that will enable calibration of large diameter optics via partial illumination in a diverging beam. The newly expanded x-ray test capabilities of the facility will be discussed.

XRCF↗

Getting NuSTAR on Target: Predicting Mast Motion

The Nuclear Spectroscopic Telescope Array (NuSTAR) is the first focusing high energy (3-79 keV) X-ray observatory operating for four years from low Earth orbit. The X-ray detector arrays are located on the spacecraft bus with the optics modules mounted on a flexible mast of 10.14m length. The motion of the telescope optical axis on the detectors during each observation is measured by a laser metrology system and matches the pre-launch predictions of the thermal flexing of the mast as the spacecraft enters and exits the Earths shadow each orbit. However, an additional motion of the telescope field of view was discovered during observatory commissioning that is associated with the spacecraft attitude control system and an additional flexing of the mast correlated with the Solar aspect angle for the observation. We present the methodology developed to predict where any particular target coordinate will fall on the NuSTAR detectors based on the Solar aspect angle at the scheduled time of an observation. This may be applicable to future observatories that employ optics deployed on extendable masts. The automation of the prediction system has greatly improved observatory operations efficiency and the reliability of observation planning.

NASA small explorer↗