Analysis of the SAVY-4000 nuclear material storage container for transportation
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
N/A
Abstract Not Provided
Explore the source record for details and available documents.
Abstract Not Provided
Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.
The behaviour of nanometre-scale precipitates in oxide dispersion strengthened (ODS) ferritic alloys and tungsten-rhenium alloys for nuclear applications has been examined by atom probe tomography (APT). Low Re content tungsten alloys showed no evidence of Re clustering following self-ion irradiation whereas the 25 at.% Re resulted in cluster formation. The size and composition of clusters varied depending on the material form during irradiation (pre-sharpened needle or bulk). Lastly, these results highlight the care that must be taken in interpreting data from ion irradiated pre-sharpened needles due to the presence of free surfaces. Self-ion irradiation of the ODS ferritic alloy resulted in a change in the composition of the clusters, indicating a transition from a near-stoichiometric Y 2 Ti 2 O 7 composition towards a Ti 2 YO 5 .
A sub-par container packaging instance was evaluated and lessons learned shared.
Explore the source record for details and available documents.
For measuring a waste drum containing multi-nuclide radioactive material calorimetric assay is often combined with gamma ray and neutron measurements. To reduce the methodological uncertainties of the inventory determination in a multi-nuclide matrix, the escaping radiation must be quantized as much as the encapsulated gamma-rays and α-, β-, n- particles depositing radiological heat inside the drum. To differentiate the possible variety of heat sources in a radioactive waste drum, Monte Carlo simulations are utilized resembling the waste drum and the calorimeter in both, their geometries as well as the material compositions. MCNP6-based numerical imaging of the Large Volume Calorimeter (LVC) designed by KEP Nuclear(France) allows simulating various scenarios for different particles types, energies and source locations to accompany and support the interpretation of calorimetric KEP-LVC measurements anticipated within the CHANCE project. For the analyses, the particle flux and energy deposition in each layer of the calorimeter are displayed. The results yield that a significant part of the emitted radiation leaves the system and does not contribute to the heat deposited inside the drum. As an example, the particle flux study of a 200 L mock-up drum placed inside the KEP-LVC calorimeter is discussed. A tally 4 with mesh option for both gamma and neutrons up to 5 MeV simulates the mean flux in each cell and for various source location and source distribution patterns. The expected energy deposition is cumulated for each layer, and over the whole energy range it reveals that actually a small but well known fraction of particles escapes the LVC calorimeter. This makes it a very suitable apparatus for the anticipated experiments on large and heterogeneous waste drums. The results suggest that the most interesting cases would be polyethylene, bitumen and concrete matrices [3, 5]. However, it must be kept in mind that the high-energy part of the gamma and neutron radiation flux can reach the reference chamber of the calorimeter and deposit some energy there, which may compromise the calibration and cause double-bias. The simulations showed that, depending on source location and power, neutron and high-energy gamma radiation leakage can influence the heat measurements differently. In general, part of the simulation results suggest that for waste drums with a high emission rate the accuracy of calorimetric assay can be decreased due to radiation escape. (authors)
Gloveboxes are isolation barriers that are used within many different industries such as pharmaceuticals, electronic parts fabrication, nuclear, and biological. The research on glovebox ergonomics is currently limited with few ergonomic professionals that focusing exclusively on glovebox working environments. There is existing documentation on occupational injuries, such as musculoskeletal disorders (MSD), sustained as a direct result of working in gloveboxes. The main elements that pose ergonomic risks to glovebox workers are operational repetition, duration, force, vibration, lifting heavy (more than 15lbs with two hands) objects, and awkward postures. This paper examines a small sample of the potential causal or risk factors that lead to the ergonomic injuries. A meta-analysis utilizing a random effect model is used to examine data from several studies which focus on, dexterity and strength changes as result of glove thickness, and robotic assistive technology as a means to improve postural mechanics. With the meta-analysis technique, similar data sets from different research studies can be coalesced into a single weighted, statistically significant result for subsequent consideration. The results from the analysis show that increased glove thickness results in decreased dexterity for operators thus increasing ergonomic risk factors such as task duration. It is also shown that glove thickness decreases grip strength but a similar decrease in pinch strength is not definitively demonstrated. With decreased grip strength, operators will need to exert more force (a known ergonomic risk factor) on processing tools, etc. during operations thus increasing the risk of ergonomic injury. The use of robotic assistive technology as a means to improve operator posture (risk factor) was also examined. Although it may be intuitively assumed that human-robotic collaboration would be beneficial in reducing risk factors, the result from this study’s analysis was not statistically significant. It is inferred that with additional directed research on this topic another study/analysis could be statistically significant demonstrating the benefits of the technology.
This report provides a summary of the literature review that was performed and based on previous work performed at the Idaho National Laboratory studying the Three Mile Island 2 (TMI-2) nuclear reactor accident, specifically the melted fuel debris. The purpose of the literature review was to document prior published work that supports the feasibility of the analytical techniques that were developed to provide quantitative results of the make-up of the fuel and reactor component debris located inside and outside the containment. The quantitative analysis provides a technique to perform nuclear fuel accountancy measurements
Abstract not provided.
Understanding and improving microstructural mechanical stability in metals and alloys is central to the development of high strength and high ductility materials for cladding and cores structures in advanced fast reactors. Design and enhancement of radiation-induced damage tolerant alloys are facilitated by better understanding the connection of various unit processes to collective responses in a multiscale model chain, including: dislocation nucleation, absorption and desorption at interfaces; vacancy production, radiation-induced segregation of Cr and Ni at defect clusters (point defect sinks) in BCC Fe-Cr ferritic/martensitic steels; investigation of interaction of interstitials and vacancies with impurities (V, Nb, Ta, Mo, W, Al, Si, P, S); time evolution of swelling (cluster growth) phenomena of irradiated materials; and energetics and kinetics of dislocation bypass of defects formed by interstitial clustering and formation of prismatic loops, informing statistical models of continuum character with regard to processes of dislocation glide, vacancy agglomeration and swelling, climb and cross slip.
Abstract not provided
No abstract prepared.
Explore the source record for details and available documents.
The present disclosure includes a radiological material detector having a convertor material that emits one or more photons in response to a capture of a neutron emitted by a radiological material; a photon detector arranged around the convertor material and that produces an electrical signal in response to a receipt of a photon; and a processor connected to the photon detector, the processor configured to determine the presence of a radiological material in response to a predetermined signature of the electrical signal produced at the photon detector. One or more detectors described herein can be integrated into a detection system that is suited for use in port monitoring, treaty compliance, and radiological material management activities.