Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiphase flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insight into pseudo-film-boiling in supercritical water under simplified interfacial conditions

The focus of this paper is the physics of supercritical water film boiling through the simulation of natural convection of supercritical water in a rectangular cavity. It has been widely believed that above a fluid's critical point, only one phase exists. However, recent research has indicated the existence of distinct gas-like and liquid-like regions separated by the Widom line, which is the locus of the maxima of the specific heat. Along the Widom line, density decreases sixfold, viscosity drops by a factor of two, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film-boiling, denoted here as pseudo-two-phase flow dynamics. When the cavity is heated from the bottom, a pseudo-film of gas-like fluid is formed at the heated wall, and the flow complexity evolves, characterized by the formation of multiple vortices. Results demonstrate the ability of modern conjugate heat transfer computational fluid dynamics to capture the pseudo two-phase regime, with the formation of a pseudo-film at the heated wall. Further, the boiling curve is studied, showing an increase in heat flux with an increase in the temperature differential between the wall and the pseudo-critical temperature. Furthermore, results also show a previously uncharacterized instability, where the convection cells in the cavity oscillate and can flip directions under certain conditions.

Computational fluid dynamics↗

The impact of capillary heterogeneity on CO 2 flow and trapping across scales

Capillary heterogeneity has been identified over the last decade as a key control on subsurface CO 2 flow behavior during geological CO 2 sequestration. These heterogeneities can be formed in all sedimentary rocks, ranging from slight variations in the sand grain sizes to extensive sequences of interbedded sands, shales, and limestones. Capillary heterogeneity has been largely, although not entirely, overlooked in subsurface flow modeling because it is assumed to only directly influence fluid redistribution over scales of centimeters to meters. However, even small-scale fluid movements can result in dramatic impacts on the mobility and trapping of the CO 2 over kilometers. Therefore, neglecting capillary heterogeneity at multiple scales could potentially lead to errors in modeling and predicting field-scale plume migration. In this review paper, we aim to provide a consistent overview to (1) establish that capillary heterogeneity can have a major impact on CO 2 plume migration, (2) establish the respective length scales at which capillary heterogeneity matters, and (3) provide guidance for numerical modeling. This review covers pertinent literature and extracts key observations from the core to the field scales. Experimental studies have shown that millimeter-decimeter scale capillary heterogeneity can cause the so-called capillary heterogeneity trapping in addition to pore-scale residual trapping. Even at such a small scale, capillary heterogeneity can already lead to complex upscaled constitutive relationships, such as flow-rate dependent and anisotropic relative permeability, which affects field-scale CO 2 migration even when field-scale heterogeneities are present. Under gravity-dominated flow regimes, centimeter-meter scale capillary heterogeneity can entrap a significant amount of CO 2 at field scale, not just after imbibition but also during drainage. In certain cases, the presence of capillary heterogeneity can even completely stop the vertical movement of the CO 2 plume, hence greatly reducing leakage risks. At meter-kilometer scale, the influence of capillary heterogeneity is more pronounced and can hinder or redirect CO 2 migration in both lateral and vertical directions. The impact of capillary heterogeneity across multiple spatial scales poses a great challenge in modeling CO 2 migration at field scale, because it is practically impossible to build a field-scale earth model with grid blocks at millimeter scale. We recommend a hierarchical modeling approach to address this challenge. At field scale, earth models are built to capture geological features and heterogeneities in high but still practical grid resolutions. For each facies or rock type of the field-scale model, high- resolution meter-scale “conceptual” models are built with millimeter-scale grid blocks to capture representative fine-scale bedding geometries and heterogeneities in various environments of deposition, bridging the gap from subcore scale to the size of a field-scale simulation grid block. Upscaling is then used to preserve the smaller-scale flow dynamics of various rock types in field-scale simulations. Here, future work is needed to (1) refine, improve, and validate the hierarchical modeling approach; (2) build libraries of fine-scale bedding models for facies in various environments of deposition; (3) quantify multiscale capillary heterogeneity effects under subsurface uncertainties; (4) gain learning from different storage formations; and (5) establish best practices that balance accuracy and computational speed.

Capillary heterogeneity↗

GEOS: A performance portable multi-physics simulation framework for subsurface applications

GEOS is a simulation framework focused on solving tightly coupled multi-physics problems with an initial emphasis on subsurface reservoir applications. Currently, GEOS supports capabilities for studying carbon sequestration, geothermal energy, hydrogen storage, and related subsurface applications. The unique aspect of GEOS that differentiates it from existing reservoir simulators is the ability to simulate tightly coupled compositional flow, poromechanics, fault slip, fracture propagation, and thermal effects, etc. Extensive documentation is available on the GEOS documentation pages (GEOS Documentation, 2024). Note that GEOS, as presented here, is a complete rewrite of the previous incarnation of the GEOS referred to in (Settgast et al., 2017).

58 GEOSCIENCES↗

MACHINE LEARNING-ENABLED PREDICTION OF TRANSIENT INJECTION MAP IN AUTOMOTIVE INJECTORS WITH UNCERTAINTY QUANTIFICATION

Accurate prediction of injection profiles is a critical aspect of linking injector operation with engine performance and emissions. However, highly resolved injector simulations can take one to two weeks of wall-clock time, which is incompatible with engine design cycles with desired turnaround times of less than a day. Hence, it is important to reduce the time-to-solution of the internal flow simulations by several orders of magnitude to make it compatible with engine simulations. This work demonstrates a data-driven approach for tackling the computational overhead of injector simulations, whereby the transient injection profiles are emulated for a side-oriented, single-hole diesel injector using a Bayesian machine-learning framework. First, an interpretable Bayesian learning strategy was employed to understand the effect of design parameters on the total void fraction field. Then, autoencoders are utilized for efficient dimensionality reduction of the flowfields. Gaussian process models are finally used to predict the spatiotemporal void fraction field at the injector exit for unknown operating conditions. The Gaussian process models produce principled uncertainty estimates associated with the emulated flowfields, which provide the engine designer with valuable information of where the data-driven predictions can be trusted in the design space. The Bayesian flowfield predictions are compared with the corresponding predictions from a deep neural network, which has been transfer-learned from static needle simulations from a previous work by the authors. The emulation framework can predict the void fraction field at the exit of the orifice within a few seconds, thus achieving a speed-up factor of up to 38 x 10(6) over the traditional simulation-based approach of generating transient injection maps.

machine learning↗

Pressure fields produced by single-bubble collapse near a corner

Damage produced by repeated bubble collapse to neighboring rigid objects in hydraulic systems is an important consequence of cavitation. Although bubble collapse near a single wall has received significant attention in the past, few studies exist on the dynamics of bubbles collapsing near a corner, i.e., two flat rigid surfaces intersecting at a right angle. In this work we quantify the pressure fields produced by a single bubble collapsing near two perpendicular rigid walls. Using a high-order accurate shock- and interface-capturing method to solve the three-dimensional compressible Navier-Stokes equations for gas and liquid flows, we simulate the dynamics of a single bubble collapsing at different initial stand-off distances from the two walls. In contrast to a bubble collapsing near a single wall, the collapse of bubbles within a critical stand-off distance is not symmetric about the bisecting plane due to the interaction between the bubble and the second wall. The second wall affects the pressure produced during the collapse in the following ways: (i) For bubbles initially located sufficiently close to both walls, the reentrant jet produced during collapse no longer points in the direction normal to the closest wall but at an angle toward the corner, (ii) the part of the emitted shock with the highest amplitude propagates in line with the jet, and (iii) the bubble migrates in that same direction during its collapse with a dependence on the stand-off distance, consistent with predictions made using Kelvin impulse. The location of maximum pressure along the walls is measured for the different initial stand-off distances. Using acoustic arguments, we find a semiempirical relationship to predict the initial stand-off distances for which the maximum pressure occurs in the corner. Here we find that when the bubble is sufficiently close to equidistant from each boundary, the maximum pressure is observed in the corner due to the water-hammer and implosion shocks reflecting off the boundaries and intersecting in the corner. We also show that when bubbles are initially attached to either wall the wall pressure produced can be significantly increased compared to bubbles detached from either wall.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MFC 5.0: An exascale many-physics flow solver

Many problems of interest in engineering, medicine, and the fundamental sciences rely on high-fidelity flow simulation, making performant computational fluid dynamics solvers a mainstay of the open-source software community. Previous work MFC 3.0 was made a published, documented, and open-source solver via Bryngelson et al. Comp. Phys. Comm. (2021) with numerous physical features, numerical methods, and scalable infrastructure. MFC 5.0 is a significant update to MFC 3.0, featuring a broad set of well-established and novel physical models and numerical methods, as well as the introduction of GPU and APU (or superchip) acceleration. Here, we exhibit state-of-the-art performance and ideal scaling on the first two exascale supercomputers, OLCF Frontier and LLNL El Capitan. Combined with MFC’s single-accelerator performance, MFC achieves exascale computation in practice, and achieved the largest-to-date public CFD simulation at 200 trillion grid points as a 2025 ACM Gordon Bell Prize finalist. New physical features include the immersed boundary method, N-fluid phase change, Euler–Euler and Euler–Lagrange sub-grid bubble models, fluid-structure interaction, hypo- and hyper-elastic materials, chemically reacting flow, two-material surface tension, magnetohydrodynamics (MHD), and more. Numerical techniques now represent the current state-of-the-art, including general relaxation characteristic boundary conditions, WENO variants, Strang splitting for stiff sub-grid flow features, and low Mach number treatments. Weak scaling to tens of thousands of GPUs on OLCF Summit and Frontier and LLNL El Capitan achieves efficiencies within 5% of ideal to over 90% of their respective system sizes. Strong scaling results for a 16-times increase in device count show parallel efficiencies over 90% on OLCF Frontier. MFC’s software stack has undergone further improvements, including continuous integration, which ensures code resilience and correctness through over 300 regression tests; metaprogramming, which reduces code length while maintaining performance portability; and code generation for computing chemical reactions

Computational fluid dynamics↗

Open source implementation of glued sphere discrete element method and nonspherical biomass fast pyrolysis simulation

Here, in this research, a glued-sphere Discrete Element Method (DEM) method was implemented in the open-source, Computational Fluid Dynamics (CFD) software MFiX. The implementation was verified using a cylinder-wall collision and then validated by simulating the packing and fluidization of non-spherical particles. The validated code was applied to simulate fast pyrolysis of non-spherical biomass particles in a bubbling fluidized bed. The glued sphere occupancy ratio was proposed to quantify the quality of shape resolution using glued sphere. Shape resolution showed significant influence on the packing height in the simulation of particle packing and an occupancy ratio of 80 % was recommended. Its influence is minor in fully fluidized bed but can be 8 times higher in fixed fluidized bed. Three tested heat transfer models predicted similar yields of elongated biomass fast pyrolysis. The solver developed in this research can be used to simulate other multiphase reacting flows involving non-spherical particles.

42 ENGINEERING↗

Very small-scale, segregating-fluidized-bed experiments: A dataset for CFD-DEM validation and uncertainty quantification

IWe report fluidization experiments were conducted on a small scale and with a rapid response (short duration) to enable corresponding simulations at low-computational cost. Rise times are reported for four or fewer polyethylene particles (intruders) in an air-fluidized bed of ~5000 group D glass beads. Experimental inputs were completely characterized—particle properties, system dimensions and operating conditions—which is necessary for validating computational fluid mechanics (CFD)-discrete element method (DEM) including a comprehensive uncertainty quantification (UQ) analysis. Input uncertainties are reported as bounds or cumulative distribution functions of measured values. The staggering number of simulations required to complete a UQ analysis (~O[10 4 ] simulations corresponding to ~5 uncertain inputs) motivates this study. These segregating-bed experiments are designed to permit analogous CFD-DEM simulations to complete in less than a day on a single (~2.5 GHz) computational processor unit (CPU). Segregation times are reported for several operating conditions, intruder sizes, and initial configurations, providing a rich dataset for numerical model testing, validation and UQ.

42 ENGINEERING↗

Model-parallel Fourier neural operators as learned surrogates for large-scale parametric PDEs

Fourier neural operators (FNOs) are a recently introduced neural network architecture for learning solution operators of partial differential equations (PDEs), which have been shown to perform significantly better than comparable deep learning approaches. Once trained, FNOs can achieve speed-ups of multiple orders of magnitude over conventional numerical PDE solvers. However, due to the high dimensionality of their input data and network weights, FNOs have so far only been applied to two-dimensional or small three-dimensional problems. To remove this limited problem-size barrier, we propose a model-parallel version of FNOs based on domain-decomposition of both the input data and network weights. Here, we demonstrate that our model-parallel FNO is able to predict time-varying PDE solutions of over 2.6 billion variables on Perlmutter using up to 512 A100 GPUs and show an example of training a distributed FNO on the Azure cloud for simulating multiphase CO 2 dynamics in the Earth’s subsurface.

58 GEOSCIENCES↗

High pressure/high temperature multiphase simulations of dodecane injection to nitrogen: Application on ECN Spray-A

The present work investigates the complex phenomena associated with pressure/high temperature dodecane injection for the Engine Combustion Network (ECN) Spray-A case, employing more elaborate thermodynamic closures, to avoid well known deficiencies concerning density and speed of sound prediction using traditional cubic models. A tabulated thermodynamic approach is proposed here, based on log 10 (p)-T tables, providing very high accuracy across a large range of pressures, spanning from 0 to 2500 bar, with only a small number of interpolation points. The tabulation approach is directly extensible to any thermodynamic model, existing or to be developed in the future. Here NIST REFPROP properties are used, combined with PC-SAFT Vapor-Liquid-Equilibrium to identify the liquid in mixtures penetration, hence avoiding the use of an arbitrary threshold for mass fraction. Identified liquid and vapour penetration are compared against experimental data from the ECN database showing a good agreement, within approximately 3–8% for axial penetration of liquid, 2% for vapor axial penetration and within experimental uncertainty for radial distribution of mass fraction. Analysis of the vortex evolution indicates that driving mechanisms behind the jet break-up are vortex tilting/stretching, then baroclinic torque, leading to Rayleigh-Taylor instabilities, closely followed by vortex dilation and finally viscous effects.

42 ENGINEERING↗

A micromechanical hydro-mechanical-damage coupled model for layered rocks considering multi-scale structures

An anisotropic Hydro-Mechanical-Damage coupled model was established in the framework of thermodynamics for saturated layered rocks, which contain arbitrarily-distributed cracks of smaller scales and orientated bedding planes of much larger scales. Here, the proposed model considers the anisotropic damage growth and frictional sliding of cracks and shear sliding and dilatancy of bedding planes, as well as the interaction between cracks and bedding planes. Numerical implementation of the nonlinear coupled model was developed based on TOUGHREACT, which is a well-established simulator for multiphase fluid flow and reactive transport analysis. The proposed model was first validated with laboratory water injection test results on rock blocks, and then used to study the effects of injection rates, in situ stresses and bedding planes on fluid injection processes at the field scale, demonstrating the importance to consider the variation of multi-scale structures for better understanding the coupled Hydro-Mechanical responses in layered rocks.

58 GEOSCIENCES↗

Modeling supercritical CO2 injection induced rupture of a minor fault embedded in a poroelastic layered reservoir-caprock system

CO2 injection for geologic carbon sequestration involves hydromechanical processes that lead to changes in fluid pressure and stresses that can activate existing faults. This paper presents a new method and workflow of modeling fault activation considering more complex three-dimensional geometry of natural faults using the TOUGH-FLAC multiphase fluid flow and geomechanical simulator. In this method and workflow, FLAC3D mechanical interfaces and TOUGH3 finite volume elements are discretized using computer aided design and gridding software along with a tailored mesh translation routine. The method and workflow are demonstrated with a model of a curved minor fault embedded in a poro-elastic layered reservoir-caprock system. The model is used for a comprehensive sensitivity analysis of fault responses to fault length, injection mass rate, injection schedule, well-fault distance, and well locations versus fault location. Four metrics (CO2 plume, shear state of fault, pressure and stress path at fault monitoring points) are selected to assess CO2 migration, pressure change, and the reactivation of faults. The results reveal that CO2 can bypass around the tip of the minor impermeable fault, building up pressure and poro-elastic stress on both sides that tends to impede fault rupture. Our study shows the benefit of carefully designing the injection to achieve the targeted final storage volume, starting at a relatively low rate for considerable time, and then ramping up the injection rate to the full rate of injection. The initial low injection has two distinct benefits: (1) it allows for the formation of an extensive CO2 plume with a much higher mobility through a low viscosity that will result in a lower pressure for a given injection rate, and (2) it allows for gradual build-up of horizontal poro-elastic stress within the reservoir that will tend to impede activation of steeply dipping faults. The injection scenario starting at a low injection rate, denoted here as conservative injection, can significantly reduce the risk of fault activation as high fluid mobility and reservoir strengthening poro-elastic stress has been established long before reaching the peak injection rates. Moreover, simultaneous injection in two injection wells on both sides of fault can provide further reservoir strengthening through poro-elastic stress buildup acting on a fault under normal faulting stress regime. The findings presented in the paper can provide practical and effective guidance on long-term, safe, and reliable geological CO2 storage.

Cao, Meng↗

Factors controlling injection-induced rupture of intersecting faults during geological sequestration of CO 2

This study addresses coupled multiphase fluid flow and geomechanics effects on potential fault activation associated with subsurface CO 2 injection around intersecting faults. An enhanced fault-representation model is used to capture geomechanical responses of two intersecting faults with finite length during CO 2 injection. The faults are embedded in a strike-slip stress regime of a caprock-reservoir-basement system with the faults represented by zero-thickness interfaces with adjacent finite-thickness damage zones. A sensitivity analysis is conducted to study the effect of fault permeability, slip-weakening behavior, well location relative to the orientation of faults, and well placement (the number and location of injection wells). Five metrics (pressure, CO 2 plume, shear state on the fault, as well as shear displacement and stress path at selected fault monitoring points) are selected to assess CO 2 migration and reactivation of intersecting faults. The results show that induced ruptures are favored by low permeability faults due to high pressure buildup and by slip-weakening behavior resulting from fault strength reduction. The location of one injection well relative to fault orientation determines the magnitude of changes in effective normal stress and shear stress, affecting the location of induced ruptures. Well placement (two injection wells used in the paper) dominates pressure diffusion around the intersection and tips of faults. This redistributes changes in effective normal stress caused by each injection well, influencing the spatial distribution of ruptures along faults. A larger injection volume induces far-field ruptures that are controlled by stress transfer within the injection layer. The findings presented here can provide valuable insights into engineering operations for a long-term, safe, and reliable geologic CO 2 storage.

Fault permeability↗

A conservative, interface-resolved, compressible framework for the modeling and simulation of liquid/gas phase change

This paper presents a method for simulating evaporation in a compressible, interface-resolved framework appropriate for modeling problems of engineering interest. In order to achieve robustness and broad applicability, the method has been designed to discretely enforce consistent mass and thermal energy transport at the phase interface, to globally conserve mass, momentum, and energy, and to be capable of modeling compressible and incompressible systems. Verification is performed via the Sod-shock test, one-dimensional heat conduction, evaporation from a planar interface, and evaporation of three-dimensional droplets. Convergence with increasing mesh resolution is demonstrated in all tested configurations, and conservation is maintained near machine precision for a translating droplet. Conservation and accurate phase change rates are preserved at the low numerical resolutions commonly encountered in engineering calculations. Following verification, the method is validated by comparison to an empirical correlation for evaporating droplets in high temperature crossflow, and the presentation concludes with the simulation of an iso-octane spray at conditions representative of gasoline direct injection. In conclusion, successful verification, validation, and demonstrated practical utility suggest the method to be an accurate, efficient, and robust approach for the study of phase change in engineering systems.

97 MATHEMATICS AND COMPUTING↗