Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Revealing ultrafast proton-transfer-mediated autoionization as a source of low-energy electrons in hydrogen-bonded systems

Ionizing radiation can trigger ultrafast proton transfer, a central mechanism in many chemical and biological functions, that in turn can enable or suppress electron relaxation processes and consequently cause abrupt changes in the reaction pathway. This study combines theory and experiment to probe ultrafast relaxation and dissociation in water dimers following inner- and outer-valence photoionization. By tracking electron and nuclear motion simultaneously, we reveal competing fragmentation pathways that produce low-energy electrons, which are key agents in radiation-induced chemistry, including DNA damage. While low-energy electrons are known to arise via intermolecular Coulombic decay, here we identify a faster relaxation mechanism gated by proton transfer following inner-valence ionization, which we call proton-transfer-mediated autoionization. Occurring within 10 femtoseconds, this process alters fragmentation outcomes, yielding either D 3 O + + OD + or D 2 O + + D 2 O + , depending on the interplay of proton migration and hydrogen back-transfer. Our findings underscore the intricate coupling between electronic and nuclear dynamics in hydrogen-bonded systems and establish proton-transfer-mediated autoionization as a significant pathway for low-energy electron generation.

Atomic and molecular interactions with photons↗

Long range frequency chirping of Alfvén eigenmodes

In this work, a theoretical framework has been developed for an NBI scenario to model the hard non-linear evolution of global Alfvén eigenmodes (GAEs) where the adiabatic motion of phase-space structures (holes and clumps), associated with frequency chirping, occurs in generalized phase-space of slowing down energetic particles. The radial profile of the GAE is expanded using finite elements, which allows an update of the mode structure as the mode frequency chirps. Constants of motion are introduced to track the dynamics of energetic particles during frequency chirping by implementing proper action-angle variables and canonical transformations which reduce the dynamics essentially to 1D. Consequently, we specify whether the particles are drifting inward/outward as the frequency deviates from the initial MHD eigenfrequency. Using the principle of least action, we have derived the non-linear equation describing the evolution of the radial profile by varying the total Lagrangian of the system with respect to the weights of the finite elements. For the choice of parameters in this work, it is shown that the peak of the radial profile is shifted and also broadens due to frequency chirping. The time rate of frequency change is also calculated using the energy balance and we show that the adiabatic condition remains valid once it is satisfied. This model clearly illustrates the theoretical treatment to study the long-range adiabatic frequency sweeping events observed for Alfvén gap modes in real experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shape-Based Magnetic Domain Wall Drift for an Artificial Spintronic Leaky Integrate-and-Fire Neuron

Spintronic devices based on domain wall (DW) motion through ferromagnetic nanowire tracks have received great interest as components of neuromorphic information processing systems. Prior proposals for spintronic artificial neurons required external stimuli to perform the leaking functionality, one of the three fundamental functions of a leaky integrate-and-fire (LIF) neuron. The use of this external magnetic field or electrical current stimulus results in either a decrease in energy efficiency or an increase in fabrication complexity. Here, we modify the shape of previously demonstrated three-terminal magnetic tunnel junction neurons to perform the leaking operation without any external stimuli. The trapezoidal structure causes a shape-based DW drift, thus intrinsically providing the leaking functionality with no hardware cost. This LIF neuron, thus, promises to advance the development of spintronic neural network crossbar arrays.

42 ENGINEERING↗

Toward correcting drift in target position during radiotherapy via computer-controlled couch adjustments on a programmable Linac

Purpose: Real-time tracking of respiratory target motion during radiation therapy is technically challenging, owing to rapid and possibly irregular breathing variations. The authors report on a method to predict and correct respiration-averaged drift in target position by means of couch adjustments on an accelerator equipped with such capability. Methods: Dose delivery is broken up into a sequence of 10 s field segments, each followed by a couch adjustment based on analysis of breathing motion from an external monitor as a surrogate of internal target motion. Signal averaging over three respiratory cycles yields a baseline representing target drift. A Kalman filter predicts the baseline position 5 s in advance, for determination of the couch correction. The method's feasibility is tested with a motion phantom programmed according to previously recorded patient signals. Computed couch corrections are preprogrammed into a research mode of an accelerator capable of computer-controlled couch translations synchronized with the motion phantom. The method's performance is evaluated with five cases recorded during hypofractionated treatment and five from respiration-correlated CT simulation, using a root-mean-squared deviation (RMSD) of the baseline from the treatment planned position. Results: RMSD is reduced in all 10 cases, from a mean of 4.9 mm (range 2.7-9.4 mm) before correction to 1.7 mm (range 0.7-2.3 mm) after correction. Treatment time is increased {approx}5% relative to that for no corrections. Conclusions: This work illustrates the potential for reduction in baseline respiratory drift with periodic adjustments in couch position during treatment. Future treatment machine capabilities will enable the use of 'on-the-fly' couch adjustments during treatment.

60 APPLIED LIFE SCIENCES↗

CT imaging during microwave ablation: Analysis of spatial and temporal tissue contraction

Purpose: To analyze the spatial distribution and temporal development of liver tissue contraction during high-temperature ablation by using intraprocedural computed tomography (CT) imaging. Methods: A total of 46 aluminum fiducial markers were positioned in a 60 × 45 mm grid, in a single plane, around a microwave ablation antenna in each of six ex vivo bovine liver samples. Ablations were performed for 10 min at 100 W. CT data of the liver sample were acquired every 30 s during ablation. Fiducial motion between acquisitions was tracked in postprocessing and used to calculate measures of tissue contraction and contraction rates. The spatial distribution and temporal evolution of contraction were analyzed. Results: Fiducial displacement indicated that the zone measured postablation was 8.2 ± 1.8 mm (∼20%) smaller in the radial direction and 7.1 ± 1.0 mm (∼10%) shorter in the longitudinal direction than the preablation tissue dimension. Therefore, the total ablation volume was reduced from its preablation value by approximately 45%. Very little longitudinal contraction was noted in the distal portion of the ablation zone. Central tissues contracted more than 60%, which was near an estimated limit of ∼70% based on initial water content. More peripheral tissues contracted only 15% in any direction. Contraction rates peaked during the first 60 s of heating with a roughly exponential decay over time. Conclusions: Ablation zones measured posttreatment are significantly smaller than the pretreatment tissue dimensions. Tissue contraction is spatially dependent, with the greatest effect occurring in the central ablation zone. Contraction rate peaks early and decays over time.

60 APPLIED LIFE SCIENCES↗

SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-03: Effect of Robot Pose On Beam Blocking for Ultrasound Guided SBRT of the Prostate

Purpose: Ultrasound presents a fast, volumetric image modality for real-time tracking of abdominal organ motion. How-ever, ultrasound transducer placement during radiation therapy is challenging. Recently, approaches using robotic arms for intra-treatment ultrasound imaging have been proposed. Good and reliable imaging requires placing the transducer close to the PTV. We studied the effect of a seven degrees of freedom robot on the fea-sible beam directions. Methods: For five CyberKnife prostate treatment plans we established viewports for the transducer, i.e., points on the patient surface with a soft tissue view towards the PTV. Choosing a feasible transducer pose and using the kinematic redundancy of the KUKA LBR iiwa robot, we considered three robot poses. Poses 1 to 3 had the elbow point anterior, superior, and inferior, respectively. For each pose and each beam starting point, the pro-jections of robot and PTV were computed. We added a 20 mm margin accounting for organ / beam motion. The number of nodes for which the PTV was partially of fully blocked were established. Moreover, the cumula-tive overlap for each of the poses and the minimum overlap over all poses were computed. Results: The fully and partially blocked nodes ranged from 12% to 20% and 13% to 27%, respectively. Typically, pose 3 caused the fewest blocked nodes. The cumulative overlap ranged from 19% to 29%. Taking the minimum overlap, i.e., considering moving the robot’s elbow while maintaining the transducer pose, the cumulative over-lap was reduced to 16% to 18% and was 3% to 6% lower than for the best individual pose. Conclusion: Our results indicate that it is possible to identify feasible ultrasound transducer poses and to use the kinematic redundancy of a 7 DOF robot to minimize the impact of the imaging subsystem on the feasible beam directions for ultrasound guided and motion compensated SBRT. Research partially funded by DFG grants ER 817/1-1 and SCHL 1844/3-1.

60 APPLIED LIFE SCIENCES↗

Portal Monitoring Considerations for Treaty Verification Applications

Portal monitoring is one method in a suite of options for treaty verification and can assist in verification of treaty accountable items (TAIs). Portal monitor technology spans a wide range of sensors, including radiation detectors, break-beams, or weight sensors. For radiation-detecting portal monitors, they are able to confirm absence / presence of a radiological signature and to track TAI direction of motion. Portal monitoring uses measurements from strategically placed sensors (e.g., radiation detectors) to record the entry or egress of TAIs. The implementation of portal monitoring relies on three key elements: perimeter definition, portal locations, and sensor technology, and can be implemented in either time-bound or continuous operations depending on what is permitted by the Treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Target-specific optimization of four-dimensional cone beam computed tomography

Purpose: Under-sampling artifacts are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) and may compromise evaluation of target motion. Several studies have addressed scan parameter selection for minimizing under-sampling artifacts; however, the role of the target characteristics in scan parameter selection has not been investigated. In this work, the authors evaluated 4D-CBCT performance by assessing the accuracy of target motion measurements for various target sizes and motions. The results may serve as patient-specific guidelines for scan parameters selection in 4D-CBCT. Methods: The authors acquired 4D-CBCT scans of a moving phantom consisting of six water-filled sphere targets of sizes 10-37 mm, using various scan times ranging from 30 s to 3 min., setting the motion to 3-s and 6-s periods. The authors used automatic image registration to extract the target motion trajectories and evaluated these measurements for various target sizes and motions over various combinations of scan parameters including scan time, detector configuration, number of respiration phases, and reconstruction filters. Results: The most important object parameter to 4D-CBCT performance was the period of motion. Measurements for the 6-s motion were always systematically less accurate than measurements for the 3-s motion for 34 of 36 objects of various sizes and periods of motion. The 6-s motion required a greater scan time than the 3-s motion for equivalent measurement accuracy. The second most influential parameter was the target size. For the 3-s period of motion, objects larger than 13 mm were tracked with sub-millimeter accuracy with a 1-min scan time. For the 6-s period of motion, objects larger than 22-mm were tracked with sub-millimeter accuracy with a 1.5-min scan time. For all sizes and motions, temporal blurring was observed when the number of phases was fewer than 8. Offset detector configuration provided the same performance as centered detector except for small targets (20 mm.) at short scan times ({<=}1 min). Finally, reconstruction filtering and number of respiratory phases did not affect performance. Conclusions: Scan time should be set according to target size and motion. The authors have provided figures that provide the minimum scan time needed to achieve the particular motion measurement accuracy for a particular size and motion period.

60 APPLIED LIFE SCIENCES↗

Proper Motions of Stellar Streams Discovered in the Dark Energy Survey

We cross-match high-precision astrometric data from Gaia DR2 with accurate multi-band photometry from the Dark Energy Survey (DES) DR1 to confidently measure proper motions for nine stellar streams in the DES footprint: Aliqa Uma, ATLAS, Chenab, Elqui, Indus, Jhelum, Phoenix, Tucana III, and Turranburra. We determine low-confidence proper motion measurements for four additional stellar streams: Ravi, Wambelong, Willka Yaku, and Turbio. We find evidence for a misalignment between stream tracks and the systemic proper motion of streams that may suggest a systematic gravitational influence from the Large Magellanic Cloud. These proper motions, when combined with radial velocity measurements, will allow for detailed orbit modeling which can be used to constrain properties of the LMC and its affect on nearby streams, as well as global properties of the Milky Way's gravitational potential.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Purpose: We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). Methods and Materials: In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. Results: System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. Conclusion: We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2017 Western Passage Tidal Energy Resource Characterization Measurements

These data are from tidal resource characterization measurements collected between April and July 2017 in Western Passage near Eastport, Maine, USA. The dataset contains the following four sub-datasets, each of which is described in more detail in the README.pdf. 1. A bottom-mounted Teledyne RDI Workhorse 600 kHz acoustic Doppler current profiler (ADCP) was deployed at 44.92015 N, 66.98915 W in ~50 m of water from 3 April to 18 July (106 days). Data were recorded in 6-minute increments in the ENU (East, magnetic North, Up) coordinate system with bin-mapping enabled. 2. A bottom-mounted Nortek Signature 500 kHz ADCP was deployed at 44.92192 N, 66.98913 W in ~50 m of water from 4 April to 18 July (105 days). Data were sampled and recorded at 2 Hz and recorded in the ENU (East, magnetic North, Up) coordinate system. 3. Between those stations along a cross-channel transect, a Stable Tidal Turbulence Mooring (STTM) positioned ~10 m above the seabed was deployed for one week during a spring tide. The STTM was outfitted with two Nortek Vector acoustic Doppler velocimeters equipped with inertial motion units (ADVs), a bottom-tracking downward-looking Teledyne RDI Workhorse 600 kHz ADCP to provide motion-corrected flow and turbulence characteristics at high temporal resolution, and an upward-looking Teledyne RDI Sentinel V20 ADCP. The STTM was deployed at 44.92098 N, 66.98922 W from 24-31 May. 4. A vessel-mounted Teledyne RDI Workhorse 300 kHz ADCP collected current data along three transects over two days, 4-5 April. The data processing used DOLfYN version 0.11.2. All hdf5 files (i.e., files ending in `.h5`) contained here can be opened using that version of DOLfYN (e.g., `dat = dolfyn.load('')`). All distances are in meters (e.g., depth, range, MLLW, hab, eta, z_), and all velocities in m/s. See the DOLfYN documentation https://lkilcher.github.io/dolfyn/), and/or the Nortek and Teledyne RDI documentation for additional details. Additional details on the dataset can be found in the README.pdf, including: - Format details of each data file. - How to regenerate the data-processing (using the files in the `wp2017_processing.zip` archive).

16 TIDAL AND WAVE POWER↗

SU-C-BRF-05: Design and Geometric Validation of An Externally and Internally Deformable, Programmable Lung Motion Phantom

Purpose: Most clinically-deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating, tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are rigid-exterior+rigid-interior or rigid-exterior+deformable-interior. Neither class adequately represents the human anatomy, which is deformable internally as well as externally. We describe the construction and experimental validation of a more realistic, externally- and internally-deformable, programmable lung phantom. Methods: The outer shell of a commercially-available lung phantom (RS- 1500, RSD Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A 3-axis platform was programmed with sinusoidal and six patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam ‘diaphragm’ that compressed/decompressed the phantom interior. Experimental characterization comprised of mapping the superior-inferior (SI) and anterior-posterior (AP) trajectories of external and internal radioopaque markers with kV x-ray fluoroscopy and correlating these with optical surface monitoring using the in-room VisionRT system. Results: The phantom correctly reproduced the programmed motion as well as realistic effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.4 mm RMS error for internal as well as external markers. The motion trajectories of internal and external markers as measured by fluoroscopy were found to be highly correlated (R=0.97). Furthermore, motion trajectories of arbitrary points on the deforming phantom surface, as recorded by the VisionRT system also showed a high correlation with respect to the fluoroscopically-measured trajectories of internal markers (R=0.92). Conclusion: We have developed a realistic externally- and internally-deformable lung phantom that will serve as a valuable tool for clinical QA and motion management research. This work was supported through funding from the NIH and VisionRT Ltd. Amit Sawant has research funding from Varian Medical Systems, VisionRT and Elekta.

60 APPLIED LIFE SCIENCES↗

Smoothing of respiratory motion traces for motion-compensated radiotherapy

Purpose: The CyberKnife system has been used successfully for several years to radiosurgically treat tumors without the need for stereotactic fixation or sedation of the patient. It has been shown that tumor motion in the lung, liver, and pancreas can be tracked with acceptable accuracy and repeatability. However, highly precise targeting for tumors in the lower abdomen, especially for tumors which exhibit strong motion, remains problematic. Reasons for this are manifold, like the slow tracking system operating at 26.5 Hz, and using the signal from the tracking camera ''as is''. Since the motion recorded with the camera is used to compensate for system latency by prediction and the predicted signal is subsequently used to infer the tumor position from a correlation model based on x-ray imaging of gold fiducials around the tumor, camera noise directly influences the targeting accuracy. The goal of this work is to establish the suitability of a new smoothing method for respiratory motion traces used in motion-compensated radiotherapy. The authors endeavor to show that better prediction--With a lower rms error of the predicted signal--and/or smoother prediction is possible using this method. Methods: The authors evaluated six commercially available tracking systems (NDI Aurora, PolarisClassic, Polaris Vicra, MicronTracker2 H40, FP5000, and accuTrack compact). The authors first tracked markers both stationary and while in motion to establish the systems' noise characteristics. Then the authors applied a smoothing method based on the a trous wavelet decomposition to reduce the devices' noise level. Additionally, the smoothed signal of the moving target and a motion trace from actual human respiratory motion were subjected to prediction using the MULIN and the nLMS{sub 2} algorithms. Results: The authors established that the noise distribution for a static target is Gaussian and that when the probe is moved such as to mimic human respiration, it remains Gaussian with the exception of the FP5000 and the Aurora systems. The authors also showed that the proposed smoothing method can indeed be used to filter noise. The signal's jitter dropped by as much as 95% depending on the tracking system employed. Subsequently, the 3D prediction error (rms) for a prediction horizon of 150 ms on a synthetic signal dropped by up to 37% when using a normalized LMS prediction algorithm (nLMS{sub 2}) and hardly changed when using a MULIN algorithm. When smoothing a real signal obtained in our laboratory, the improvement of prediction was similar: Up to 30% for both the nLMS{sub 2} and the best MULIN algorithm. The authors also found a noticeable increase in smoothness of the predicted signal, the relative jitter dropped by up to 95% on the real signal, and on the simulated signal. Conclusions: In conclusion, the authors can say that preprocessing of marker data is very useful in motion-compensated radiotherapy since the quality of prediction increases. This will result in better performance of the correlation model. As a side effect, since the prediction of a preprocessed signal is also less noisy, the authors expect less robot vibration resulting in better targeting accuracy and less strain on the robot gears.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New 'Molecular Movie' Reveals Ultrafast Chemistry in Motion

Scientists for the first time tracked ultrafast structural changes, captured in quadrillionths-of-a-second steps, as ring-shaped gas molecules burst open and unraveled. Ring-shaped molecules are abundant in biochemistry and also form the basis for many drug compounds. The study points the way to a wide range of real-time X-ray studies of gas-based chemical reactions that are vital to biological processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fitness Tracker for Weight Lifting Style Workouts

This document proposes an early, high level design for a fitness tracking system which can automatically log weight lifting style workouts. The system will provide an easy to use interface both physically through the use of several wireless wristband style motion trackers worn on the limbs, and graphically through a smartphone application. Exercise classification will be accomplished by calibration of the user’s specific motions. The system will accurately track a user’s workout, miscounting no more than one repetition in every 20, have sufficient battery life to last several hours, work with existing smartphones and have a cost similar to those of current fitness tracking devices. This document presents the mission background, current state-of-theart, stakeholders and their expectations, the proposed system’s context and concepts, implementation concepts, system requirements, first sublevel function decomposition, possible risks for the system, and a reflection on the design process.

42 ENGINEERING↗

Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking System

Purpose: To investigate the frequency and amplitude of baseline shift or drift (shift/drift) of lung tumors in stereotactic body radiation therapy (SBRT), using a real-time tumor-tracking radiation therapy (RTRT) system. Methods and Materials: Sixty-eight patients with peripheral lung tumors were treated with SBRT using the RTRT system. One of the fiducial markers implanted near the tumor was used for the real-time monitoring of the intrafractional tumor motion every 0.033 seconds by the RTRT system. When baseline shift/drift is determined by the system, the position of the treatment couch is adjusted to compensate for the shift/drift. Therefore, the changes in the couch position correspond to the baseline shift/drift in the tumor motion. The frequency and amount of adjustment to the couch positions in the left-right (LR), cranio-caudal (CC), and antero-posterior (AP) directions have been analyzed for 335 fractions administered to 68 patients. Results: The average change in position of the treatment couch during the treatment time was 0.45 ± 2.23 mm (mean ± standard deviation), −1.65 ± 5.95 mm, and 1.50 ± 2.54 mm in the LR, CC, and AP directions, respectively. Overall the baseline shift/drift occurs toward the cranial and posterior directions. The incidence of baseline shift/drift exceeding 3 mm was 6.0%, 15.5%, 14.0%, and 42.1% for the LR, CC, AP, and for the square-root of sum of 3 directions, respectively, within 10 minutes of the start of treatment, and 23.0%, 37.6%, 32.5%, and 71.6% within 30 minutes. Conclusions: Real-time monitoring and frequent adjustments of the couch position and/or adding appropriate margins are suggested to be essential to compensate for possible underdosages due to baseline shift/drift in SBRT for lung cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory motion management in particle therapy

Clinical outcomes of charged particle therapy are very promising. Currently, several dedicated centers that use scanning beam technology are either close to clinical use or under construction. Since scanned beam treatments of targets that move with respiration most likely result in marked local over- and underdosage due to interplay of target motion and dynamic beam application, dedicated motion mitigation techniques have to be employed. To date, the motion mitigation techniques, rescanning, beam gating, and beam tracking, have been proposed and tested in experimental studies. Rescanning relies on repeated irradiations of the target with the number of particles reduced accordingly per scan to statistically average local misdosage. Specific developments to prohibit temporal correlation between beam scanning and target motion will be required to guarantee adequate averaging. For beam gating, residual target motion within gating windows has to be mitigated in order to avoid local misdosage. Possibly the most promising strategy is to increase the overlap of adjacent particle pencil beams laterally as well as longitudinally to effectively reduce the sensitivity against small residual target motion. The most conformal and potentially most precise motion mitigation technique is beam tracking. Individual particle pencil beams have to be adapted laterally as well as longitudinally according to the target motion. Within the next several years, it can be anticipated that rescanning as well as beam gating will be ready for clinical use. For rescanning, treatment planning margins that incorporate the full extent of target motion as well as motion induced density variations in the beam paths will result in reduced target conformity of the applied dose distributions. Due to the limited precision of motion monitoring devices, it seems likely that beam gating will be used initially to mitigate interplay effects only but not to considerably decrease treatment planning margins. Then, in the next step, beam gating, based on more accurate motion monitoring systems, provides the possibility to restore target conformity as well as steep dose gradients due to reduced treatment planning margins. Accurate motion monitoring systems will be required for beam tracking. Even though beam tracking has already been successfully tested experimentally, full clinical implementation requires direct feedback of the actual target position in quasireal time to the treatment control system and can be anticipated to be several more years ahead.

61 RADIATION PROTECTION AND DOSIMETRY↗