Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗

Dynamic Distribution Voltage Stability Control Using Distributed Energy Resources for Improved Resiliency

The main goal of this paper is to present the development and simulation of a new dynamic voltage stability control technique, with a focus on effective control and coordination of all available reactive power generation resources in a microgrid setting. Both power electronics and synchronous generator based distributed energy resources (DERs), and grid-supporting functions, are considered to accommodate a high penetration of diverse DERs and energy storage by using an enhanced microgrid voltage stabilizer. A systematic controller parameter synthesizing method is employed, and the overall dynamic voltage stability of the system is studied and evaluated with a time-domain dynamic simulation during emergency, hazard and disaster events. The results with the new approach show significant improvements and enhancements on the dynamic voltage profile of the distribution system, leading towards a more resilient grid system with high penetration of diverse DERs during emergency, hazard and disaster events.

Hatipoglu, Kenan↗

DC Microgrids Under Denial of Service Attacks: Feasibility and Stability Issues

Distributed control has been extensively studied for a DC microgrid to coordinate multiple grid assets where each asset can generate its own control decisions based on communications within its neighborhood. Nevertheless, such a control strategy usually has a strong dependence on active information exchange and needs to always maintain a pre-determined communication graph. This makes it vulnerable to cyber attacks, especially denial of service (DoS) attacks that block communication channels that effectively change the communication graph. In this paper, we study two potential impacts of DoS attacks: the inability to maintain steady-state and dynamical generation-demand balance, i.e. the feasibility and stability issues. We develop a mathematical model to describe the cyber-induced system steady-state and dynamical performance. The model reveals the impacts of DoS attacks and enables formal analysis. Case studies are shown to verify the proposed work.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Use of Power Hardware-in-the-Loop and Controller Hardware-in-the-Loop to De-Risk the Use Of Grid-Forming Fuel Cell Inverters in Microgrids

Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such interfaces are particularly challenging when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This presentation shows the use of PHIL interfaces for such microgrids and the preliminary experimental results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel State-Constrained Primary Control for Grid-Forming Inverters

The problem of operating an AC microgrid with purely inverter-based generating units is considered, and a novel vector control for the constrained grid-forming (GFM) inverters is proposed. The design aims to achieve the primary control objectives of the GFM inverters: voltage establishment, synchronization, and voltage/frequency regulation. It is novel that the proposed control also ensures all operational variables constrained both real-time and for all the time except for low voltage during the period of grid forming. The constraints include frequency, output AC voltage, input DC power, and active/reactive power injections to the grid. Here, in this paper, outcomes of a detailed simulation are presented to demonstrated that the above design objectives are met and that the overall performance is superior due to its unique ability of simultaneously controlling the whole vectors of the inverter state and output.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a State Machine for Smooth Microgrid Transition Operation

A state machine is proposed in the energy management system (EMS) of a microgrid as the solution for smooth microgrid's transition operation. This state machine includes six 'states' that cover all the operating modes during the microgrid's transition operation: two basic modes (grid-connected and islanded) and four temporary modes (preparing for disconnection, transition to islanding, preparing for resynchronization, and transition to grid-connected). Temporary modes are designed to fine-tune the control references for the microgrid assets to avoid harmful transients during microgrid transitions, therefore achieving smooth transition operation. The developed state machine is validated by simulation in MATLAB with a sample microgrid, and the test results show excellent performance of the state machine and smooth microgrid transition operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power quality of service optimization for microgrids

Various examples are provided for power quality of service optimization for microgrids. In one example, among others, a microgrid includes a smart meter configured to control supply of electric power to loads based at least in part upon energy consumption scheduling of the loads, which is based at least in part upon an effective electric generation capacity associated with the microgrid. The energy consumption scheduling can be based at least in part upon estimated power output of a sustainable energy resource of the microgrid and a load demand characterization of the loads. In another example, a system comprises a plurality of microgrids and an advanced metering infrastructure (AMI) configured to monitor operations of the microgrids and to control supply of electric power from sustainable energy resources and energy storage systems to loads of the microgrids via smart meters based at least in part upon energy consumption scheduling of the loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Model Predictive Control Based Generator Start-Up Optimization Strategy for Restoration With Microgrids as Black-Start Resources

Microgrids (MGs) can operate in an islanded mode and serve as black-start resources for power system restoration (PSR). Here, a model predictive control (MPC) based generator start-up optimization strategy for PSR is proposed utilizing MGs as black-start resources. First, the generator start-up sequence (GSUS) optimization is formulated as a mixed integer linear programming. Then, the uncertainties of MG black-start resources (MBSRs) are modeled by discretizing the probability distribution of the forecast errors, and representative scenarios for MBSRs extracted by formulating the probability mass transportation problem. Third, the generator start-up optimization strategy considering MBSRs is proposed utilizing the MPC technique, in which the optimization objective is to maximize the energy capability of the power systems and minimize the load curtailment of the MGs in each looking-ahead interval. Simulations on the IEEE 118 bus system with MGs and Zhejiang provincial power system in China verify that the introduced strategy for PSR can successfully restore the power system and effectively determine the optimal GSUS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inrush Current Mitigation for Grid-Forming Inverters in Islanded Microgrids

Virtual-inertia and droop control methods are commonly used for grid-forming inverters. While the virtual inertia is used to emulate the equation of motion/frequency, if the inverter output voltage is emulated as in synchronous generators, then the method is known as the virtual synchronous generator. An inductive pulse-load, e.g., a relatively large induction motor, connection to a microgrid fed only by grid-forming inverters may lead to blackout due to high inrush currents. This article presents virtual reactance techniques to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. This article also compares the virtual inertia and droop control methods under switching inductive-dynamic loads while the proposed techniques are implemented. Experimental tests are performed considering the linear and nonlinear virtual reactance techniques, and the findings are discussed. The mitigation significantly suppresses the inrush currents while the inverters can perform a normal operation. Furthermore, the frequency and power response of the virtual inertia control with different inertia settings to a sudden change in the load is analyzed. The virtual reactance technique is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented in this article.

Gursoy, Mehmetcan↗

Design, Operation, and Controlled-Island Operation of the U.S. Department of Energy Solar Decathlon 2013 Microgrid

This document reports on the design and operation of a high-capacity and high-penetration-ratio microgrid, which consists of 19 photovoltaic-powered residential houses designed by collegiate teams as part of their participation in the U.S. Department of Energy Solar Decathlon 2013. The microgrid was interconnected with the local utility, and resulting net-power and power-quality events were recorded in high detail (1-minute data sampling or better). Also, a controlled-island operation test was conducted to evaluate the microgrid response to additional events such as increased loads (e.g., from electric vehicles) and bypassing of voltage regulators. This temporary ground-laid microgrid was stable under nominal and island-operation conditions; adverse weather and loads did not lead to power-quality degradation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

Passivity-Based Grid Forming Control for DERs

This paper uses a passivity-based control method for grid-forming control-based distributed energy resources (DERs). A port-controlled Hamiltonian form is used to guarantee the passivity property. In addition, different passivity-based control methods are applied to different DERs in a microgrid, where an energy storage system, wind turbine, and solar-based DERs are considered. Since all the operating DERs can guarantee the passivity property, the stable operation of the microgrid is guaranteed. The simulation results demonstrate that the proposed control method effectively manages the microgrid, ensuring stable operation.

Gui, Yonghao↗

Valuing Resilience Benefits of Microgrids for an Interconnected Island Distribution System

Extreme climate-driven events such as hurricanes, floods, and wildfires are becoming more intense in areas exposed to these threats, requiring approaches to improve the resilience of the electrical infrastructure serving these communities. Long-duration outages caused by such high impact events propagate to economic, health, and social consequences for communities. As essential service providers, electric utilities are mandated to provide safe, economical and reliable electricity to their customers. The public is becoming less tolerant to these more frequent disruptions, especially in view of technological advances that are intended to improve power quality, reliability and resilience. One promising solution is state-of-the-art microgrids and the advanced controls employed therein. This paper presents and demonstrates an approach to technoeconomic analysis that can be used to value the avoided economic consequences of grid resilience investments, as applied to the islands of Vieques and Culebra in Puerto Rico. This valuation methodology can support policies to incorporate resilience value into any investment decision-making process, especially those which serve the public interest.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Incorporating energy storage and user experience in isolated microgrid dispatch using a multi-objective model

In order to coordinate multiple different scheduling objectives from the perspectives of economy, environment, and users, a practical multi-objective dynamic optimal dispatch model incorporating energy storage and user experience is proposed for isolated microgrids. In this model, besides microturbine units, energy storage is employed to provide spinning reserve services for microgirds; and furthermore, from the perspective of demand side management, a consumer satisfaction indicator is developed to measure the quality of user experience. A two-step solution methodology incorporating multi-objective optimisation and decision analysis is put forward to address this model. First, a powerful heuristic optimisation algorithm, called the -dominance based evolutionary algorithm, is used to find a well-distributed set of Pareto-optimal solutions of the problem. Thereby, the best compromise solutions are identified from the entire solutions with the use of decision analysis by integrating fuzzy C-means clustering and grey relation projection. The simulation results on the modified Oak Ridge National Laboratory Distributed Energy Control and Communication lab microgrid test system demonstrate the effectiveness of the proposed approach.

Li, Yang↗

Frequency Restoration of Grid-Forming Inverters in Pulse Load and Plug-in Events

This article presents a restoration technique using grid-forming inverters in an islanded microgrid during pulse load and plug-in events. In a microgrid powered by droop-controlled inverters, frequency is the variable that is accessible to all inverters for adjusting their power contributions. The problem is that the microgrid frequency deviates from its nominal value after a load change. The presented method enables the inverters to restore the frequency to the nominal value and regulate their bus voltage amplitudes. The frequency and voltage restorations are performed without communication while achieving the desired power-sharing between grid-forming inverters. The restoration is activated after detecting any active or reactive power changes. In this article, the dynamic model of an inverter equipped with enabled restoration paths is developed to verify the stability of the inverter controller under various conditions. The frequency and voltage restorations are examined during pulse load and plug-in events. Furthermore, this study is performed using a laboratory-scale islanded microgrid powered by two 208 V, 60 Hz, 5 kVA inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable, Physical Effects Measureable Microgridfor Cyber Resilience Analysis

SPEMMCRA provides a low-cost simulated method to provide for testing of control theory and cybersecurity approaches to microgrid implementations. Specifically, this physics-based approach provides realistic responses to compare control strategies in simulation, but also to demonstrate actions that can or cannot be taken in taking cybersecurity actions . As communications interfaces or other actions are taken that affect the flow of data, SPEMMCRA can show whether the microgrid operation is adversely affected by what is intended to mitigate a cybersecurity event.

Rieger, CraigG↗