Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

A multiomics mass spectrometry workflow for fast and comprehensive strain optimization (Abstract CRADA 726 )

The Agile Biofoundry (ABF) is a multi-national lab consortium funded by the DOE Bioenergy Technologies Office that has developed a biofoundry that enables the rapid deployment of bioproducts into the market. The ABF is a flexible platform that can adjust to the needs of numerous government, academic and industrial partners, thus enabling them to rapidly develop and optimize the production of a wide range of bioproducts. To enhance this capability, PNNL and Agilent Technologies are collaborating to expand and demonstrate a prototype system that processes hundreds of samples per day by liquid chromatography-mass spectrometry-based untargeted and targeted methods, and artificial intelligence software for multiomics applications, including metabolomics, lipidomics and proteomics.

Bilbao, Aivett (ORCID:0000000329858249)↗

Discovering type I cis-AT polyketides through computational mass spectrometry and genome mining with Seq2PKS

Type 1 polyketides are a major class of natural products used as antiviral, antibiotic, antifungal, antiparasitic, immunosuppressive, and antitumor drugs. Analysis of public microbial genomes leads to the discovery of over sixty thousand type 1 polyketide gene clusters. However, the molecular products of only about a hundred of these clusters are characterized, leaving most metabolites unknown. Characterizing polyketides relies on bioactivity-guided purification, which is expensive and time-consuming. To address this, we present Seq2PKS, a machine learning algorithm that predicts chemical structures derived from Type 1 polyketide synthases. Seq2PKS predicts numerous putative structures for each gene cluster to enhance accuracy. The correct structure is identified using a variable mass spectral database search. Benchmarks show that Seq2PKS outperforms existing methods. Applying Seq2PKS to Actinobacteria datasets, we discover biosynthetic gene clusters for monazomycin, oasomycin A, and 2-aminobenzamide-actiphenol.

60 APPLIED LIFE SCIENCES↗

An Experimental Method to Measure Gaseous Diffusivity in Tight and Partially Saturated Porous Media via Continuously Monitored Mass Spectrometry

Detection of radioxenon and radioargon produced by underground nuclear explosions is one of the primary methods by which the Comprehensive Nuclear-Test–Ban Treaty (CTBT) monitors for nuclear activities. However, transport of these noble gases to the surface via barometric pumping is a complex process relying on advective and diffusive processes in a fractured porous medium to bring detectable levels to the surface. To better understand this process, experimental measurements of noble gas and chemical surrogate diffusivity in relevant lithologies are necessary. However, measurement of noble gas diffusivity in tight or partially saturated porous media is challenging due to the transparent nature of noble gases, the lengthy diffusion times, and difficulty maintaining consistent water saturation. Here, the quasi-steady-state Ney–Armistead method is modified to accommodate continuous gas sampling via effusive flow to a mass spectrometer. An analytical solution accounting for the cumulative sampling losses and induced advective flow is then derived. Experimental results appear in good agreement with the proposed theory, suggesting the presence of retained groundwater reduces the effective diffusivity of the gas tracers by 10–1000 times. Finally, by using a mass spectrometer, the method described herein is applicable to a broad range of gas species and porous media.

47 OTHER INSTRUMENTATION↗

Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses

A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Expanded Coverage of Phytocompounds by Mass Spectrometry Imaging Using On-Tissue Chemical Derivatization by 4-APEBA

Probing the entirety of any species metabolome is an analytical grand challenge, especially at a cellular scale. Where spatial metabolomics, completed primarily by matrix-assisted laser desorption/ionization (MALDI), has limited molecular coverage for several reasons. To expand the scope of spatial metabolomics, we developed an on-tissue chemical derivatization (OTCD) workflow using 4-APEBA for confident identification of several dozen elusive phytocompounds, including several phytohormones, which have various roles within stress responses and cellular communication. Superiority of 4-APEBA is established in comparison to other derivatization agents with (1) broad specificity towards carbonyls, (2) low background, and (3) introduction of bromine isotopes, where the latter two facilitate confident bioinformatics. In conclusion, the outlined workflow trailblazes a path towards spatial hormonomics within plant samples, enhancing detection of carboxylates, aldehydes, ketones, and plausibly phenols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of impurities in cubic boron nitride (cBN) by inductively coupled plasma mass spectrometry (ICPMS)

The phase stability of cBN is critically dependent on the content and amount of impurities present. While studies have shown qualitatively that the addition of certain impurities can either increase or decrease the cBN-hBN phase transition temperature, studies have yet to show this effect quantitatively. This is because analytical methods to characterize minor and trace impurities in cBN are currently lacking. To this end, we present flux fusion methods capable of fully digesting cBN samples for ICPMS analyses. The materials used in this study are commercially available cBN powders in three different sizes. Two types of fluxes (LiOH and NaOH·H 2 O) are utilized so that both Li and Na impurities can be determined. To ensure the accuracy of Si measurements, a column chromatography method has been developed to purify Si from flux materials in order to increase the amount of dissolved sample sent to the ICP. Detection limits have been determined using procedural blanks and are found to be below 20 μg/g for all 58 elements analyzed except for Si, for which the detection limit is 312 μg/g. Nonetheless, all cBN powders studied are found to have high Si impurity levels that are above detection limit. This study provides a much-needed analytical protocol to enable comprehensive screening of impurities in cBN.

36 MATERIALS SCIENCE↗

Analysis of furnace contamination on superconducting radio frequency niobium using secondary-ion mass spectrometry

Detection of surface contamination on niobium materials used in superconducting radio frequency (SRF) applications is difficult due to quantitative sensitivity and near-atomic depth resolution needed. Inspection of samples known to have experienced surface contamination was found to have inconsistent nitride coverage after high-temperature nitrogen gas exposure (“doping”). Here we compare contaminating species found on samples treated in several different vacuum furnaces, both “exposed” directly in the chamber and “protected” by containment shielding from evaporative sources with “furnace caps.” Typically, furnace caps are used to impede contamination from reaching the interior surface of cavities during the high-temperature vacuum bake that immediately precedes exposure to nitrogen gas. Although, to date, little is known about the effectiveness of these caps, SIMS results showed that they were effective in limiting contamination arising from the furnace environment. Inspection of sample surfaces by SEM showed a lack of nitrides present on contaminated specimens. TEM with energy dispersive spectroscopy performed on these samples revealed that a carbon-rich layer now existed, indicating that a relatively high contaminant load prevents the nucleation and growth of surface nitrides, while thus inhibiting interstitial nitrogen uptake. Except in extreme cases, subsequent removal of the top several micrometers of the surface via electropolishing appears to effectively eliminate any strong influence on the subsequent SRF cavity performance. With the absence of furnace cleaning, carbon contamination was found to be nearly 10× higher for protected nitrogen-doped and electropolished samples, with minimal metallic contamination detected for both processes. SIMS analysis was also performed to compare the cleanliness of samples fully prepared by such nitrogen “doping” with those prepared by a related process, involving the dissolution of niobium surface oxide and diffusion of oxygen into the surface. This oxygen doping or alloying process offers attractive advantages.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

Enhancing characterization of organic nitrogen components in aerosols and droplets using high-resolution aerosol mass spectrometry

Abstract. This study aims to enhance the understanding and application of the Aerodyne high-resolution aerosol mass spectrometer (HR-AMS) for the comprehensive characterization of organic nitrogen (ON) compounds in aerosol particles and atmospheric droplets. To achieve this goal, we analyzed 75 N-containing organic compounds, representing a diverse range of ambient non-organonitrate ON (NOON) types, including amines, amides, amino acids, N heterocycles, protein, and humic acids. Our results show that NOON compounds can produce significant levels of NHx+ and NOx+ ion fragments, which are typically recognized as ions representative of inorganic nitrogen species. We also identified the presence of CH2N+ at m/z = 28.0187, an ion fragment rarely quantified in ambient datasets due to substantial interference from N2+. As a result, the utilization of an updated calibration factor of 0.79 is necessary for accurate NOON quantification via the HR-AMS. We also assessed the relative ionization efficiencies (RIEs) for various NOON species and found that the average RIE for NOON compounds (1.52 ± 0.58) aligns with the commonly used default value of 1.40 for organic aerosol. Moreover, through a careful examination of the HR-AMS mass spectral features of various NOON types, we propose fingerprint ion series that can aid the NOON speciation analysis. For instance, the presence of CnH2n+2N+ ions is closely linked with amines, with CH4N+ indicating primary amines, C2H6N+ suggesting secondary amines, and C3H8N+ representing tertiary amines. CnH2nNO+ ions (especially for n values of 1–4) are very likely derived from amides. The co-existence of three ions, C2H4NO2+, C2H3NO+, and CH4NO+, serves as an indicator for the presence of amino acids. Additionally, the presence of CxHyN2+ ions indicates the occurrence of 2N-heterocyclic compounds. Notably, an elevated abundance of NH4+ is a distinct signature for amines and amino acids, as inorganic ammonium salts produce only negligible amounts of NH4+ in the HR-AMS. Finally, we quantified the NOON contents in submicron particles (PM1) and fog water in Fresno, California, and PM1 in New York City (NYC). Our results revealed the substantial presence of amino compounds in both Fresno and NYC aerosols, whereas concurrently collected fog water in Fresno contained a broader range of NOON species, including N-containing aromatic heterocycle (e.g., imidazoles) and amides. These findings highlight the significant potential of employing the widespread HR-AMS measurements of ambient aerosols and droplets to enhance our understanding of the sources, transformation processes, and environmental impacts associated with NOON compounds in the atmosphere.

Ge, Xinlei (ORCID:0000000195316478)↗

A novel sector mass spectrograph design for high-order coded aperture Mass Spectrometry with stigmatic aberration correction

Previous works experimentally demonstrated that the application of spatially-coded apertures to simple sector mass spectrographs can result in increased signal intensity while maintaining spectral resolution comparable to that of a conventional slit aperture.[Chen, E.X., et al.: J Am Soc Mass Spectr. 26, 1633 (2015)][Russell, Z.E., et al.: J Am Soc Mass Spectr. 26, 248 (2015)] This spatial coding technique was later applied to a double-focusing Mattauch-Herzog mass spectrograph, and shown to be generally compatible with the architecture.[Russell, Z.E., et al.: J Am Soc Mass Spectr. 27, 1 (2016)] However, the achieved signal gain was limited by the spatial size of the electric sector gap. In this work, we introduce a modified version of the Mattauch-Herzog mass spectrograph with a wide-gap electric sector that is enabled by a novel, segmented-electrode approach, and show via simulation that this modified architecture alone (without aperture coding) achieves a 1.8x improvement in mass resolving power compared to a conventional Mattauch-Herzog spectrograph of equivalent size. Further, simulation of an aperture-coded version of the instrument supports a predicted signal strength increase of 50x with minimal loss of aperture clarity on the sensor due to the increased open area of the high-order coded aperture which can be passed.

47 OTHER INSTRUMENTATION↗

Utilizing metal cation reactions with carbonyl sulfide to remove isobaric interferences in tandem inductively coupled plasma mass spectrometry analyses

Carbonyl sulfide (OCS) was used as a reaction gas to investigate gas phase metal (M + ) ion-molecule reactions using the Agilent 8900 inductively coupled plasma tandem mass spectrometer (ICP-MS/MS) to yield insight on how this gas may be used to remove isobaric interferences in analytical measurements. The experimental work was paired with density functional theory (DFT) calculations of the reaction enthalpy to predict whether M + will react with OCS. A multi-element standard containing 46 elements ranging from 9 to 208 u was analyzed in the presence and absence of OCS. When a reaction was observed, the dominant product was the sulfide (MS + ). Oxide products were also observed for many M + but formation was less efficient with OCS than previously observed with other reaction gases. This is likely due to the weaker OC-S bond that makes MS + formation more favorable. Increasing the flow rate from 0.1 to 0.2 mL/min (corresponding to a change in reaction gas pressure from 0.35 to 0.53 Pa (2.6 to 4.0 mTorr)) generally resulted in greater MS + production, including the secondary product MS 2 + for a few cations. The early lanthanide series ions (La + , Ce + , Pr + and Nd + ) produced greater quantities of MO + at the higher pressure, although MS + products were still the dominant product. The DFT-predicted reaction enthalpies were consistent with the observed sulfide formation, with an accuracy >90%; however, model predictions were less accurate for the minor and higher order products (< 77% for MO + ). Finally, the work presented here continues a systematic study of ion-molecule reactions in ICP-MS/MS to understand and develop new and novel ways to analyze complex mixtures with minimal pre-analysis treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RAPID UNSEPARATED RARE EARTH ELEMENT ANALYSES BY ISOTOPE DILUTION MULTICOLLECTOR INDUCTIVELY COUPLED MASS SPECTROMETRY (ID-MC-ICP-MS)

We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.

Shen, Steve D.↗