Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

An Improved Top-Down Mass Spectrometry Characterization of Chlamydomonas reinhardtii Histones and Their Post-translational Modifications

We present an updated analysis of the linker and core histone proteins and their proteoforms in the green microalga Chlamydomonas reinhardtii by top-down mass spectrometry (TDMS). The combination of high-resolution liquid chromatographic separation, robust fragmentation high, mass spectral resolution, the application of a custom search algorithm, and extensive manual analysis enabled the characterization of 86 proteoforms across all four core histones H2A, H2B, H3 and H4, and the linker histone H1. All canonical H2A paralogs, which vary in their C-termini, were identified, along with an unreported non-canonical variant that had both high levels of acetylation and C-terminal truncations. Similarly, a majority of the canonical H2B paralogs were identified, along with a smaller non-canonical variant, H2B.v, that was highly acetylated. Histone H4 exhibited a novel acetylation profile that differs significantly from that found in other organisms. A majority of H3 was monomethylated at K4, while a small fraction of H3 was trimethylated at K4 and also highly acetylated.

59 BASIC BIOLOGICAL SCIENCES↗

Cometary and interstellar dust grains - Analysis by ion microprobe mass spectrometry and other techniques

A survey of microanalytical measurements on interplanetary dust particles (IDPs) and interstellar dust grains from primitive meteorites is presented. Ion-microprobe mass spectrometry with its capability to determine isotopic compositions of many elements on a micron spatial scale has played a special role. Examples are measurements of H, N, and O isotopes and refractory trace elements in IDPs; C, N, Mg, and Si isotopes in interstellar SiC grains; and C and N isotopes and H, N, Al, and Si concentrations in interstellar graphite grains.

Zinner, Ernst↗

In Situ Mg/Ca Measurements on Foraminifera: Comparison Between Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Wavelength-Dispersive X-Ray Spectroscopy by Electron Probe Microanalyzer

We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (−0.046 mmol mol−1) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [−0.315, 0.223] mmol mol−1. For samples with ratios lower than 13 mmol mol−1, we found a mean EPMA–LA-ICP-MS bias of −2.44 mmol mol−1 and a corresponding LoA of [−3.85, −1.04] mmol mol−1. For ratios higher than 13 mmol mol−1, there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than ∼13 mmol mol−1.

EPMA↗

Quantifying Phospholipids in Organic Samples Using a Hydrophilic Interaction Liquid Chromatography–Inductively Coupled Plasma High-Resolution Mass Spectrometry (HILIC-ICP-HRMS) Method

Here, in this study, a novel method using hydrophilic interaction liquid chromatography (HILIC) coupled with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was introduced for the quantification of phospholipids in oil samples. The method employed a bridged ethyl hybrid (BEH) stationary phase HILIC column with a tetrahydrofuran (THF)/water mobile phase, enhancing the solubility and detection of phospholipids. During the study, a gradient/matrix effect on ICP-HRMS sensitivity was observed and successfully compensated for experimentally, ensuring reliable quantification results. This approach has proven effective for a wide range of different oil samples including vegetable oils, animal fats, and phospholipid supplements. Notably, this method allowed the direct quantification of phospholipids in oil samples, bypassing the need for prior sample preparation methods, such as solid phase extraction (SPE), thereby streamlining the analytical process. The precision, accuracy, and reduced need for extensive sample preparation offered by this method mark a significant advancement in lipids analysis. Its robustness and broad applicability have substantial implications for industries such as food and renewable energy production, where both efficient and accurate lipid identification and quantification are crucial.

09 BIOMASS FUELS↗

Analysis of LDEF experiment AO187-2: Chemically and isotopic measurements of micrometeoroids by secondary ion mass spectrometry

Numerous 'extended impacts' found in both leading and trailing edge capture cells have been successfully analyzed for the chemical composition of projectile residues by secondary ion mass spectrometry (SIMS). Most data have been obtained from the trailing edge cells where 45 of 58 impacts have been classified as 'probably natural' and the remainder as 'possibly man-made debris.' This is in striking contrast to leading edge cells where 9 of 11 impacts so far measured are definitely classified as orbital debris. Although all the leading edge cells had lost their plastic entrance foils during flight, the rate of foil failure was similar to that of the trailing edge cells, 10 percent of which were recovered intact. Ultra-violet embrittlement is suspected as the major cause of failure on both leading and trailing edges. The major impediment to the accurate determination of projectile chemistry is the fractionation of volatile and refractory elements in the hypervelocity impact and redeposition processes. This effect had been noticed in simulation experiment but is more pronounced in the Long Duration Exposure Facility (LDEF) capture cells, probably due to the higher average velocities of the space impacts. Surface contamination of the pure Ge surfaces with a substance rich in Si but also containing Mg and Al provides an additional problem for the accurate determination of impactor chemistry. The effect is variable, being much larger on surfaces that were exposed to space than in those cells that remained intact. Future work will concentrate on the analyses of more leading edge impacts and the development of new SIMS techniques for the measurement of elemental abundances in extended impacts.

Source record↗

Application of ion-induced nucleation mass spectrometry in the analysis of trace gases evolved from a polyimide film during the thermal curing stages

Trace gases evolved from a polyimide film during its thermal curing stages have been studied using ion-induced nucleation mass spectrometry. The technique involved exposing the test gas sample to a low energy beta source and recording the masses of the ion-induced molecular clusters formed in the reaction chamber. On the basis of the experimentally observed molecular cluster spectra, it has been concluded that the dominant trace component had a molecular weight of 87 atomic mass units. This component has been identified as a molecule of dimethylacetamide (DMAC) which had been used as a solvent in the preparation of the test polyimide specimen. This identification has been further confirmed by comparing the spectra of the test gas sample and the DMAC calibration sample obtained with a conventional mass spectrometer. The advantages of the ion-induced nucleation mass spectrometer versus the conventional mass spectrometer are discussed.

Smith, A. C.↗

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Chromatography Mass Spectrometry study of eutectic bis(2,2-dinitropropyl) acetal/formal

This study is the first attempt to document methodology development undergone using liquid chromatography tandem quadrupole time of flight mass spectrometry (LC-QTOF) to investigate degradation products of eutectic bis(2,2-dinitropropyl) acetal/formal nitroplasticizer (called NP here). Method properties investigated are: desolvation temperature (°C) and spray voltage (V) of the electrospray ionization source, and the development of an acetone system rinse to prevent any residual contamination between sample injections. Details are given on why it is essential to investigate method optimization with changes shown in MS/MS analysis in addition to MS results. Trends in MS/MS analytic results reveal important relationships between baseline and aged materials. In addition to verification of previously proposed fragments, insights offered by this newly developed methodology will also identify new degradation products and shed light on the complexity of NP degradation chemistry.

36 MATERIALS SCIENCE↗

Designing Porous Ion Emitters for Thermal Ionization Mass Spectrometry: Evaluating Metal-Organic Frameworks

In this work we describe the first exploration of metal-organic frameworks (MOFs) as ‘next generation’ ion emitters for thermal ionization mass spectrometry (TIMS). MOFs were identified as promising candidates for this application given the synthetic control over their desired structural properties. This tunability results in well-ordered, high surface area, high porosity frameworks with targeted sorption affinities. Here we explored an aluminum-based, bipyridine-containing MOF (MOF-253) with and without incorporating the high work function metal, rhenium (Re). After analysis of a Nd-bearing MOF, we hypothesized that the well-dispersed, sponge-like interconnected network of the degraded structure would enhance Nd ionization more than traditional TIMS loading activators (i.e., phosphoric acid). Compared to filaments loaded with phosphoric acid that require an additional benzene carburization step, the Nd ionization efficiencies (atoms detected relative to atoms loaded) for heated filaments loaded with MOF-253 were similar (~1%). Electron microscopy after TIMS analysis demonstrated that the MOF was retained on the filament and, as hypothesized, preserved sub-micron porosity post analysis. While these results are preliminary, they demonstrate that MOFs have potential to enhance ionization and exceed the performance of traditional loading techniques by forming nano-porous ion emitters (nano-PIEs). Thus, further experimentation is likely to exceed this performance through more specific selection of the base MOF structure and modifications to porosity and composition. This work represents a novel application of MOFs and a next step in the pursuit of advanced thermal ionization with potential to expand across the periodic table.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

R “SHINY” GUI DEVELOPMENT FOR URANIUM ISOTOPIC ANALYSIS WITH MATRIX-ASSISTED IONIZATION MASS SPECTROMETRY

The international nuclear safeguards community continues to seek rapid, accurate, and precise characterization capabilities for the in-field measurement of uranium isotopic compositions in nuclear facilities. Mass spectrometry (MS) is considered the “gold standard” for analysis of relatively long-lived actinides such as uranium (U) and plutonium; however, conventional MS analysis often requires time consuming sample preparation and complex analytical methodologies that are difficult to perform in-field or in-facility. Matrix assisted ionization (MAI) is a novel ambient ionization MS technique (i.e., MAI-MS) that potentially addresses these challenges due to the relative simplicity of the ionization phenomenon and ruggedness of ambient MS instrumentation. Savannah River National Laboratory (SRNL, USA) has demonstrated this technique for nanogram-level 235U/238U isotope ratio measurements within seconds, with percent-level analytical uncertainties capable of discriminating depleted, natural, and low-enriched uranium. Current experimental work on developing MAI methods for uranium isotopic analysis has been enabled by parallel development of a comprehensive MAI-MS data analysis suite at SRNL. Development of this bespoke data analysis software was necessary because commercially available ambient MS software is poorly suited for uranium isotope ratio measurement. The effort leverages the power of R, a popular open-source programming language, and Shiny, an R package providing tools for graphical user interface (GUI) and web interface coding. This software allows researchers without any programming experience to harness and utilize R’s considerable data analysis/visualization power.

LaBone, Elizabeth D.↗

Resource for the Development of Biomedical Accelerator Mass Spectrometry (AMS) Final Report

The NIH Research Resource for Biomedical AMS was originally funded at Lawrence Livermore National Laboratory in 1999 to develop and apply the technology of accelerator mass spectrometry (AMS) in broad- based biomedical research. The Resource’s niche is to fill needs for ultra high sensitivity quantitation when isotope-labeled agents are used. The Research Resource’s Technology Research and Development (TR&D) efforts will focus on the needs of the biomedical research community in the context of seven Driving Biomedical Projects (DBPs) that will drive the Center’s technical capabilities through three core TR&Ds. We will expand our present capabilities by developing a fully integrated HPLC AMS to increase our capabilities for metabolic measurements, we will develop methods to understand cellular processes and we will develop and validate methods for the application of AMS in human studies, which is a growing area of demand by collaborators and service users. In addition, we will continue to support new and ongoing collaborative and service projects that require the capabilities of the Resource. The Center will continue to train researchers in the use of the AMS capabilities being developed, and the results of all efforts will be widely disseminated to advance progress in biomedical research. Towards these goals, our specific aims are to:1.) Increase the value and information content of AMS measurements by combining molecular speciation with quantitation of defined macromolecular isolates. Specifically, develop and validate methods for macromolecule labeling, characterization and quantitation.2.) Develop and validate methods and strategies to enable AMS to become more broadly used in human studies. Specifically, demonstrate robust methods for conducting pharmacokinetic/pharmacodynamics studies in humans and model systems.3.) Increase the accessibility of AMS to the Biomedical research community and the throughput of AMS through direct coupling to separatory instruments.4.) Provide high throughput 14C BioAMS analysis for collaborative and service clients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Initial results of positron ionization mass spectrometry

The use of monoenergetic positrons for the ionization of organic molecules in the gas phase is described. The ionic products are analyzed with a time-of-flight mass spectrometer and detected to produce a mass spectrum. The ionization mechanisms which can be studied in this way include positron impact at energies above the ionization limit of the target molecules, positronium formation in the Ore gap energy range, and positron attachment at energies less than 1eV. The technique of positron ionization mass spectrometry (PIMS) may have analytical utility in that chemical selectivity is observed for one or more of these processes.

Donohue, D. L.↗

Investigation of isovaline enantiomeric excesses in CM meteorites using liquid chromatography time of flight mass spectrometry

The enantiomeric abundances of the alpha-dialkyl amino acid isovaline were measured in the CM2 meteorites Murchison and LEW 90500 using a new liquid chromatography-time of flight-mass spectrometry (LC-ToF-MS) technique coupled with OPA/NAC derivatization and UV fluorescence detection. Previous analyses of Murchison have shown that L-enantiomeric excesses of isovaline range from 0 to 15.2% with significant variation between meteorite fragments [1]. For this study, hot water extracts of interior fragments (> 2 cm from fusion crust) of the Murchison (USNM 6650.2, mass 6 g) and LEW 90500 (split 69, parent 1, mass 5 g) carbonaceous meteorites were analyzed. Enantiomeric excesses were measured using the single ion LC-ToF-MS trace for the OPA/NAC derivative of isovaline at d z 393.15 (Fig. 1). L-isovaline excesses in these meteorite samples ranged from 18.9 to 20.5% for Murchison and -0.5 to 3.0% for LEW 90500. The measured values for Murchison are the largest enantiomeric excesses for isovaline reported to date. The enantiomeric excesses of L-isovaline cannot be the result of interference from other C5 amino acid isomers present in the meteorites or terrestrial contamination from the landing site environments. The L-isovaline excesses in Murchison are inconsistent with the synthesis of all of the isovaline by the Strecker-cyanohydrin pathway on the CM meteorite parent body. The mechanism(s) for the formation of the enantiomeric asymmetry in isovaline in Murchison are currently unknown and it is not clear how the asymmetry of alpha-dialkyl amino acids could be transferred to the a-hydrogen protein amino acids common in all life on Earth today.

Glavin, Daniel P.↗

Reactions of U + with H 2 , D 2 , and HD Studied by Guided Ion Beam Tandem Mass Spectrometry and Theory

The kinetic energy-dependent reactions of the atomic actinide uranium cation (U + ) with H 2 , D 2 , and HD were examined by guided ion beam tandem mass spectrometry. An average 0 K bond dissociation energy of D 0 (U + – H) = 2.48 ± 0.06 eV is obtained by analysis of the endothermic product ion cross sections. Quantum chemistry calculations were performed for comparison with experimental thermochemistry, including high-level CASSCF–CASPT2–RASSI calculations of the spin–orbit corrections. CCSD(T) and the CASSCF levels show excellent agreement with experiment, whereas B3LYP and PBE0 slightly overestimate and the M06 approach badly underestimates the bond energy for UH + . Theory was also used to investigate the electronic structures of the reaction intermediates and potential energy surfaces. The experimental product branching ratio for the reaction of U + with HD indicates that these reactions occur primarily via a direct reaction mechanism, despite the presence of a deep-well for UH 2 + formation according to theory. The reactivity and hydride bond energy for U + are compared with those for transition metal, lanthanide, and actinide cations, and periodic trends are discussed. Furthermore, these comparisons suggest that the 5f electrons on uranium are largely core and uninvolved in the reactive chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong-field induced fragmentation and isomerization of toluene probed by ultrafast femtosecond electron diffraction and mass spectrometry

We investigate the fragmentation and isomerization of toluene molecules induced by strong-field ionization with a femtosecond near-infrared laser pulse. Momentum-resolved coincidence time-of-flight ion mass spectrometry is used to determine the relative yield of different ionic products and fragmentation channels as a function of laser intensity. Ultrafast electron diffraction is used to capture the structure of the ions formed on a picosecond time scale by comparing the diffraction signal with theoretical predictions. Through the combination of the two measurements and theory, we are able to determine the main fragmentation channels and to distinguish between ions with identical mass but different structures. In addition, our diffraction measurements show that the independent atom model, which is widely used to analyze electron diffraction patterns, is not a good approximation for diffraction from ions. Here, we show that the diffraction data is in very good agreement with ab initio scattering calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗