Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MULTIPLEXERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Parametric amplification of angularly multiplexed waves for application to beam smoothing

The parametric amplification of angularly multiplexed waves is studied via modeling and experiments. The phase-matching properties of the amplification process with a single pump, including parasitic interactions of pairs of signal/idler, are investigated. An experimental demonstration with up to six signal waves is presented, with a quantification of the output properties, including stability relative to the input pump and seeds. A proof-of-concept study of beam smoothing induced by combining up to 12 speckle fields generated from six signal waves and six idler waves is shown.

Dorrer, C. [University of Rochester, NY (United St↗

Real-time multiplexed digital cavity-enhanced spectroscopy

Cavity-enhanced spectroscopy is a sensitive optical absorption technique but one where the practical applications have been limited to studying small wavelength ranges. In addition, this Letter shows that wideband operation can be achieved by combining techniques usually reserved for the communications community with that of cavity-enhanced spectroscopy, producing a multiplexed real-time cavity-enhanced spectrometer. We use multiple collinear laser sources operating asynchronously and simultaneously while being detected on a single photodetector. This is synonymous with radio frequency (RF) cellular systems in which signals are detected on a single antenna but decoded uniquely. Here, we demonstrate results with spectra of methyl salicylate and show parts-per-billion per root hertz sensitivity measured in real-time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Point-by-point inscribed sapphire parallel fiber Bragg gratings in a fully multimode system for multiplexed high-temperature sensing

In this work, we study the point-by-point inscription of sapphire parallel fiber Bragg gratings (sapphire pFBGs) in a fully multimode system. A parallel FBG is shown to be critical in enabling detectable and reliable high-order grating signals. The impacts of modal volume, spatial coherence, and grating location on reflectivity are examined. Three cascaded seventh-order pFBGs are fabricated in one sapphire fiber for wavelength multiplexed temperature sensing. Using a low-cost, fully multimode 850-nm interrogator, reliable measurement up to 1500°C is demonstrated.

42 ENGINEERING↗

Multiplexed color centers in a silicon photonic cavity array

Entanglement distribution is central to the modular scaling of quantum processors and establishing quantum networks. Color centers with telecom-band transitions and long spin coherence times are suitable candidates for long-distance entanglement distribution. However, high-bandwidth memory-enhanced quantum communication is limited by high-yield, scalable creation of efficient spin-photon interfaces. Here, we develop a silicon photonics platform consisting of arrays of bus-coupled cavities. The coupling to a common bus waveguide enables simultaneous access to individually addressable cavity-enhanced T center arrays. We demonstrate frequency-multiplexed operation of two T centers in separate photonic crystal cavities. In addition, we investigate the cavity enhancement of a T center through hybridized modes formed between physically distant cavities. Our results show that bus-coupled arrays of cavity-enhanced color centers could enable efficient on-chip and long-distance entanglement distribution.

Komza, Lukasz↗

Multiplexed Digital mRNA Profiling of the Inflammatory Response in the West Nile Swiss Webster Mouse Model

Background and purpose: The ability to track changes in gene expression following viral infection is paramount to understanding viral pathogenesis. This study was undertaken to evaluate the nCounter, a high throughput digital gene expression system, as a means to better understand West Nile virus (WNV) dissemination and the inflammatory response against WNV in the outbred Swiss Webster (SW) mouse model over the course of infection. Methodology: The nCounter Mouse Inflammation gene expression kit containing 179 inflammation related genes was used to analyze gene expression changes in multiple tissues over a nine day course of infection in SW mice following intraperitoneal injection with WNV. Protein expression levels for a subset of these cytokine/chemokine genes were determined using a multiplex protein detection system (BioPlex) and comparisons of protein/RNA expression levels made. Results: Expression analysis of spleen, lung, liver, kidney and brain of SW mice infected with WNV revealed that Cxcl10 and Il12b are differentially expressed in all tissues tested except kidney. Data stratification of positively confirmed infected (WNV (+)) versus non-infected (WNV (2) tissues allowed differentiation of the systemic inflammatory gene response from tissue specific responses arising from WNV infection. Significant (p,0.05) decrease in C3ar1 was found in WNV (2) spleen. Il23a was significantly upregulated, while Il10rb was down-regulated in WNV (2) lung. Il3 and Mbl2 were down-regulated in WNV (2) liver. In WNV (+) livers, Stat1, Tlr2, chemokines Cxcl1, Cxcl3, Cxcl9, Cxcl10, cytokines Il6, Il18, cytokine-related gene Il1r and cytokine agonist Ilrn were significantly upregulated. In WNV (2) brain tissues, Csf2 and Cxcl10 were significantly upregulated. Similar gene and protein expression kinetics were found for Ccl2, Ccl3, Ccl4 and Ccl5 and correlated with the presence of infectious virus. In summary, the utility of the nCounter platform for rapid identification of gene expression changes in SW mice associated with WNV infection was demonstrated.

54 ENVIRONMENTAL SCIENCES↗

Skip the Alignment: Degenerate, Multiplex Primer and Probe Design Using K-mer Matching Instead of Alignments

PriMux is a new software package for selecting multiplex compatible, degenerate primers and probes to detect diverse targets such as viruses. It requires no multiple sequence alignment, instead applying k-mer algorithms, hence it scales well for large target sets and saves user effort from curating sequences into alignable groups. PriMux has the capability to predict degenerate primers as well as probes suitable for TaqMan or other primer/probe triplet assay formats, or simply probes for microarray or other single-oligo assay formats. PriMux employs suffix array methods for efficient calculations on oligos 10-,100 nt in length. TaqManH primers and probes for each segment of Rift Valley fever virus were designed using PriMux, and lab testing comparing signatures designed using PriMux versus those designed using traditional methods demonstrated equivalent or better sensitivity for the PriMux-designed signatures compared to traditional signatures. In addition, we used PriMux to design TaqManH primers and probes for unalignable or poorly alignable groups of targets: that is, all segments of Rift Valley fever virus analyzed as a single target set of 198 sequences, or all 2863 Dengue virus genomes for all four serotypes available at the time of our analysis. The PriMux software is available as open source from http:// sourceforge.net/projects/PriMux.

59 BASIC BIOLOGICAL SCIENCES↗

Pooled PPIseq: Screening the SARS-CoV-2 and human interface with a scalable multiplexed protein-protein interaction assay platform

Protein-Protein Interactions (PPIs) are a key interface between virus and host, and these interactions are important to both viral reprogramming of the host and to host restriction of viral infection. In particular, viral-host PPI networks can be used to further our understanding of the molecular mechanisms of tissue specificity, host range, and virulence. At higher scales, viral-host PPI screening could also be used to screen for small-molecule antivirals that interfere with essential viral-host interactions, or to explore how the PPI networks between interacting viral and host genomes co-evolve. Current high-throughput PPI assays have screened entire viral-host PPI networks. However, these studies are time consuming, often require specialized equipment, and are difficult to further scale. Here, we develop methods that make larger-scale viral-host PPI screening more accessible. This approach combines the mDHFR split-tag reporter with the iSeq2 interaction-barcoding system to permit massively-multiplexed PPI quantification by simple pooled engineering of barcoded constructs, integration of these constructs into budding yeast, and fitness measurements by pooled cell competitions and barcode-sequencing. We applied this method to screen for PPIs between SARS-CoV-2 proteins and human proteins, screening in triplicate >180,000 ORF-ORF combinations represented by >1,000,000 barcoded lineages. Our results complement previous screens by identifying 74 putative PPIs, including interactions between ORF7A with the taste receptors TAS2R41 and TAS2R7, and between NSP4 with the transmembrane KDELR2 and KDELR3. We show that this PPI screening method is highly scalable, enabling larger studies aimed at generating a broad understanding of how viral effector proteins converge on cellular targets to effect replication.

60 APPLIED LIFE SCIENCES↗

Multiplexed Optical Fiber Sensors for Coal Fired Advanced Fossil Energy Systems

This report summarizes technical progress on the program Multiplexed Optical Fiber Sensors for Coal Fired Advanced Fossil Energy Systems funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed jointly by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering and the Department of Materials Science and Engineering at Virginia Tech. This three-year project started on October 1, 2008. In the project, a fiber optical sensing system based on intrinsic Fabry-Perot Interferometer (IFPI) was developed for strain and temperature measurements for Ultra Supercritical boiler condition assessment. Investigations were focused on sensor design, fabrication, attachment techniques and novel materials for high temperature and strain measurements. At the start of the project, the technical requirements for the sensing technology were determined together with our industrial partner Alstom Power. As is demonstrated in Chapter 4, all the technical requirements are successfully met. The success of the technology extended beyond laboratory test; its capability was further validated through the field test at DOE NETL, in which the sensors yielded distributed temperature mapping of a testing coupon installed in the turbine test rig. The measurement results agreed well with prior results generated with thermocouples. In this project, significant improvements were made to the IFPI sensor technology by splicing condition optimization, transmission loss reduction, sensor signal demodulation and sensor system design.

01 COAL, LIGNITE, AND PEAT↗

A Search for Low-Mass Dark Matter with the Cryogenic Dark Matter Search and the Development of Highly Multiplexed Phonon-Mediated Particle Detectors

A wide variety of astrophysical observations indicate that approximately 85% of the matter in the universe is nonbaryonic and nonluminous. Understanding the nature of this "dark matter" is one of the most important outstanding questions in cosmology. Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter since they would be thermally produced in the early universe in the correct abundance to account for the observed relic density of dark matter. If WIMPs account for the dark matter, then rare interactions from relic WIMPs should be observable in terrestrial detectors. Recently, unexplained excess events in the DAMA/LIBRA, CoGeNT, and CRESST-II experiments have been interpreted as evidence of scattering from WIMPs with masses ~10 GeV and spin-independent scattering cross sections of 10-41-10-40 cm2. The Cryogenic Dark Matter Search (CDMS II) attempts to identify WIMP interactions using an array of cryogenic germanium and silicon particle detectors located at the Soudan Underground Laboratory in northern Minnesota. In this dissertation, data taken by CDMS II are reanalyzed using a 2 keV recoil energy threshold to increase the sensitivity to WIMPs with masses ~10 GeV. These data disfavor an explanation for the DAMA/LIBRA, CoGeNT, and CRESST-II results in terms of spin-independent elastic scattering of WIMPs with masses ≲12 GeV, under standard assumptions. At the time of publication, they provided the strongest constraints on spin-independent elastic scattering from 5-9 GeV, ruling out previously unexplored parameter space. To detect WIMPs or exclude the remaining parameter space favored by the most popular models will ultimately require detectors with target masses ≳1 ton, requiring an increase in mass by more than two orders of magnitude over CDMS II. For cryogenic detectors such as CDMS, scaling to such large target masses will require individual detector elements to be fabricated more quickly and cheaply, while maintaining the nearly background-free operation of the existing experiment. We describe the development of athermal phonon mediated particle detectors using Microwave Kinetic Inductance Detectors (MKIDs), which could provide a simpler path to extending the CDMS detector technology to the ton scale. Results from prototype devices have demonstrated energy resolutions as good as σ = 0.55 keV at 30 keV, comparable to existing CDMS II detectors. Such designs can be scaled to kg-scale detector elements, while reducing the complexity of the detector fabrication and cryogenic readout electronics relative to existing designs. Since MKIDs are naturally multiplexed in the frequency domain, MKID-based designs also allow much finer pixelization of the phonon sensor, which is expected to enhance background rejection for large detectors while simultaneously reducing the number of wires needed to read out the detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Highly Multiplexed Assays for Detection of Biothreat and Food Safety Agents, CRADA No. TC02156.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and BioSearch Technologies Inc. (BTI) of Novato, California, to develop Multiplexed Molecular Assays for the Rapid and Sensitive Detection of Microbial Agents of Concern for Bioterrorism and Food Safety for the Food and Drug Administration (FDA) Center for Food Safety and Applied Nutrition (CFSAN). There are no outstanding leans for this project.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Low-Noise Amplifiers and Superconducting Flex Circuits for Frequency Domain Multiplexed Readout of Detector Arrays

The next-generation ground-based cosmic microwave background (CMB) experimental program aims to provide definitive measurements of the early universe using telescopes configured with large focal plane arrays requiring ~100,000 detectors and associated readout amplifiers and interconnecting components that are currently unavailable commercially. We describe research to demonstrate the feasibility of developing low-noise cryogenic amplifiers based on series SQUID arrays that are suitable for frequency domain multiplexed readout of large numbers of CMB detectors, and the feasibility of developing robust superconducting flex cables that will simplify cryogenic systems integration for large CMB instruments. Two iterations of prototype series SQUID array amplifier designs were completed. The designs were optimized using modeling and simulation tools to meet the requirements for CMB detector readouts. Two fabrication runs were completed, and a large number of devices from each design iteration were tested and characterized at 4 K. We also completed the development of processes for the fabrication of prototype superconducting flex cables on 4" wafers. Samples were tested for strength and robustness, and to determine the critical current at 4 K as a function of trace width. The new generation of series SQUID array amplifier designs exhibit excellent performance characteristics – very smooth output characteristics that simplify tuning and operation, low input inductance, low current noise referred to the input, and low power dissipation that for the first time will enable these devices to be operated at the focal plane array stage of CMB instruments. The processes developed in Phase I to produce superconducting flex cables were used to complete the fabrication of a full wafer with several test and sample flex circuits. The 6-micron thick flex material is very strong with a breaking strength of several pounds for a 20-mm wide strip. Critical current density was reasonable and scaled with trace width as expected.

79 ASTRONOMY AND ASTROPHYSICS↗

Highly Multiplexed Assays for Detection of Biothreat and Food Safety Agents Final Report CRADA No. TC02156.0

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and BioSearch Technologies Inc. (BTI) of Novato, California, to develop Multiplexed Molecular Assays for the Rapid and Sensitive Detection of Microbial Agents of Concern for Bioterrorism and Food Safety for the Food and Drug Administration (FDA) Center for Food Safety and Applied Nutrition (CFSAN). There are no outstanding leans for this project.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling Information Multiplexing in the Hippocampus

Modern computers are constantly faced with the challenge of processing ever-growing quantities of data that span a wide range of modalities. Of particular relevance to national security interests is the ability to integrate multimodal data for the purpose of fast decision making. The brain is a biological system that is specialized for high performance at this task, suggesting that understanding the mechanisms by which neural circuits integrate multimodal data may lead to improved man-made detection systems. This research focused on understanding these neural algorithms, and specifically tested the hypothesis that hippocampal neurons multiplex information from two different input streams. Specifically, we compare the spiking behavior of a computational model of hippocampal circuitry with neurophysiological data recorded from rodent hippocampus.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostic Testing for COVID-19 Bridging Study for CDC EUA assays vs CDC Multiplex N1 FAM, N2 SUN, RNAse P ATTO 647 Assays

This report describes testing performed by LANL’s Biological Agent Testing Laboratory (BATL) to validate modifications to the CDC EUA 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (EUA-CDC-nCoV-IFU). BATL intends to implement the modification to increase thoughput for daily testing. BATL validated the original component, CDC designed primers and probes purchased from IDT (Cat # 10006770) and the new component, CDC assays designed with new Reporter dyes allowing the assays to be multiplexed, IDT (Cat # 10006830, 10006831, 10006823, 10006833, 10006834, 10007050, 10006836, 10006837, 10007062)

59 BASIC BIOLOGICAL SCIENCES↗

Multiplexed Probing for Functional Capacity Measurements in Complex and Limited-Size Samples

A new strategy using glass as a solid support for functionalization with chemical probes has been recently developed with successful results. The next step in glass functionalization is to pair chemical probes with fluorescent glass microspheres. This approach gives us a way to directly quantify probe-bound protein using Fluorescence-Activated Cell Sorting (FACS). FACS has already shown to be amendable to glass microspheres, demonstrating changes in probe-bound protein concentration. Suitable probing conditions for gram-positive and negative microbes, complex microbial communities from myriad ecosystems, and eukaryotic cells/tissues have traditionally suffered from set-backs, such as limited protein per sample and conditions atypical for probing. To remedy this, we propose to: (1) Demonstrate probe functionalization specific to glass microspheres by paired fluorophore and use those activity probes successfully with proteomics. Probes that are currently available (CYP5, GSH/GST, Glycoside Hydrolase) can be easily prepared onto glass surfaces. Probe-bound microspheres can be tested in ratios, first with known amounts of purified protein and then complex microbiome lysates. (2) Our validated microspheres are then used to determine quantitative amounts of protein through FACS sorting. Complimenting these results by proteomics, prepared microspheres are then optimized and condensed into a user-friendly kit. Once successfully commercialized, this multiplexed assay can be used with little to no technical expertise, making this available to various industries users.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed Inertial Coalescence Filters for High-Rate Liquid-Gas Chemistry

The aim of this project is to support the development of a disruptive method for deploying liquids in liquid-gas chemical processes to transform carbon dioxide capture from flue gas and ambient air streams. The proposed project is based on the development of a novel filtration method called the Helix MICRA™ (Multiplexed Inertial Coalescence Refining Apparatus) filters. Helix MICRA™ filters are a novel, patented filter that enable high efficiency, low-pressure drop capture of droplet streams. Liquid droplets have a large net-surface area per unit volume and have correspondingly rapid mass transfer rates. By effectively capturing these droplets after deployment, we enable high-rate carbon dioxide capture from air streams unlike any other technology. This project aims at using Helix MICRA™ filters to create efficient and compact carbon dioxide capture systems that would dramatically reduce system size and capital costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed Sensor for Synthesis Gas Compsition and Temperature

The overall goal of this project has been to develop a highly sensitive, multiplexed TDL-based sensor for CO{sub 2}, CO, H{sub 2}O (and temperature), CH{sub 4}, H{sub 2}S, and NH{sub 3}. Such a sensor was designed with so-called 'plug-and-play' characteristics to accommodate additional sensors, and provided in situ path-integrated measurements indicative of average concentrations at speeds suitable for direct gasifier control. The project developed the sensor and culminated in a real-world test of the underlying technology behind the sensor. During the project, new underlying measurements of spectroscopic constants for all of the gases of interest performed, in custom cells built for the project. The envisioned instrument was built from scratch from component lasers, fiber optics, amplifier blocks, detectors, etc. The sensor was tested for nearly a week in an operational power plant. The products of this research are expected to have a direct impact on gasifier technology and the production of high-quality syngas, with substantial broader application to coal and other energy systems. This report is the final technical report on project DE-FG26-04NT42172. During the project we completed all of the milestones planned in the project, with a modification of milestone (7) required due to lack of funding and personnel.

01 COAL, LIGNITE, AND PEAT↗

Multiplexing core & sheath extrusion system development for additive manufacturing for inner-bead multi-material capability

Single-feed polymer extruders are widely used in large-format additive manufacturing (AM) systems; however, the increasing demand for multi-material functionality within a single part has driven significant innovation in this field. One approach involves robotic pick-and-place operations, while another explores mechanical switching of feed lines during extrusion. Although robotic pick-and-drop systems offer flexibility, they introduce longer layer times during material changes, which can negatively affect the structural integrity of the part. On the other hand, mechanical feed switching causes delays in material transitions, as the existing material must be flushed before the new material emerges from the nozzle. This poses particular challenges for smaller or more intricate parts. In this study we are developing a unique multiplexing extrusion system with core & sheath nozzle that combines two extruders via co-extrusion. This allows for a unique inside and outside inner-bead (i.e., within the same bead) multi-material capability. We believe that this technology will allow for combining neat and filled materials, ductile and stronger materials, and many other combinations to address the problems aforementioned above and disrupt the AM technology creating new opportunities and opening application areas.

Tekinalp, Halil [ORNL]↗