Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONTE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Deterministic-Monte Carlo Hybrid Methods for Eigenvalue Sensitivity Coefficient Calculations

The TSUNAMI suite within the SCALE code package includes several methods for generating sensitivity data, including multigroup (MG) and continuous-energy (CE) capabilities. For generating sensitivities with CE data, three methods are available in SCALE 6.3.0: (1) the iterated fission probability (IFP) method with the KENO Monte Carlo transport solver, (2) IFP with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance Characterization (CLUTCH) with the KENO Monte Carlo transport solver. Currently, it is difficult to generate accurate sensitivities with large reflectors when using the CLUTCH method, specifically with fissionable and hydrogenous materials. To address this issue, the work presented herein examines a methodology to calculate the adjoint flux externally with the 3D deterministic SN transport code DENOVO in SCALE; the result is then read directly into the CLUTCH-TSUNAMI sequence. This hybridization method replaces the Monte Carlo F*(r) calculation in CLUTCH while still utilizing the forward calculation. The critical benchmark HEU-MET-FAST-028-001 is used to generate sensitivities based on the inability of CLUTCH to generate accurate sensitivities. Results from the hybrid method appear to generate sensitivity values that are in excellent agreement with direct perturbations. Although further testing is needed, the method provides promising results for the development and utility of a hybrid method for use in TSUNAMI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-level Monte Carlo methods in chemical applications with Lennard-Jones potentials and other landscapes with isolated singularities

We describe and compare outcomes of various Multi-Level Monte Carlo (MLMC) method variants, motivated by the potential of improved computational efficiency over rejection based Monte Carlo, which scales poorly with problem dimension. With an eye toward its application to computational chemical physics, we test MLMC's ability to sample trajectories on two problems — a familiar double-well potential, with known stationary distributions, and a Lennard-Jones solid potential (a Galton Board). By sampling Brownian motion trajectories, we are able to compute expectations of observable averages. These multi-basin potential energy problems capture the essence of the challenges with using MLMC, namely, maintaining correspondence of sample paths as time-resolution is varied. Addressing this challenge properly can lead to MLMC significantly outperforming standard Monte Carlo path sampling. We describe the essence of this problem and suggest strategies that circumvent diverging multilevel sample paths for an important class of problems. In the tests we also compare the computational cost of several, “adaptive,” variants of MLMC. Our results demonstrate that MLMC overcomes the collision, time scale limitation of the more familiar Brownian path MC samplers, and our implementation provides tunable error thresholds, making MLMC a promising candidate for application to larger and more complex molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Monte Carlo volumetric-ray-casting estimator for global fluence tallies on GPUs

A Monte Carlo fluence estimator has been designed to take advantage of the computational power of graphical processing units (GPUs). This new estimator, termed the volumetric-ray-casting estimator, is an extension of the expectation estimator. It can be used as a replacement of the track-length estimator for the estimation of global fluence. Calculations for this estimator are performed on the GPU while the Monte Carlo random walk is performed on the central processing unit (CPU). This method lowers the implementation cost for GPU acceleration of existing Monte Carlo particle transport codes as there is little modification of the particle history logic flow. Three test problems have been evaluated to assess the performance of the volumetric-ray-casting estimator for neutron transport on GPU hardware in comparison to the standard track-length estimator on CPU hardware. Evaluation of neutron transport through air in a criticality accident scenario showed that the volumetric-ray-casting estimator achieved 23 times the performance of the track-length estimator using a single core CPU paired with a GPU and 15 times the performance of the track-length estimator using an eight core CPU paired with a GPU. Finally, simulation of a pressurized water reactor fuel assembly showed that the performance improvement was 6 times within the fuel and 7 times within the control rods using an eight core CPU paired with a single GPU.

74 ATOMIC AND MOLECULAR PHYSICS↗

Lefschetz thimble quantum Monte Carlo for spin systems

Monte Carlo simulations are useful tools for modeling quantum systems, but in some cases they suffer from a sign problem, leading to an exponential slow down in their convergence to a value. While solving the sign problem is generically NP hard, many techniques exist for mitigating the sign problem in specific cases; in particular, the technique of deforming the Monte Carlo simulation's plane of integration onto Lefschetz thimbles (complex hypersurfaces of stationary phase) has seen significant success in the context of quantum field theories. We extend this methodology to spin systems by utilizing spin coherent state path integrals to reexpress the spin system's partition function in terms of continuous variables. Using some toy systems, we demonstrate its effectiveness at lessening the sign problem in this setting, despite the fact that the initial mapping to spin coherent states introduces its own sign problem. The standard formulation of the spin coherent path integral is known to make use of uncontrolled approximations; despite this, for large spins they are typically considered to yield accurate results, so it is somewhat surprising that our results show significant systematic errors. Furthermore, possibly of independent interest, our use of Lefschetz thimbles to overcome the intrinsic sign problem in spin coherent state path integral Monte Carlo enables a novel numerical demonstration of a breakdown in the spin coherent path integral.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variational Monte Carlo calculations of n + H 3 scattering

A paramount goal in nuclear physics is to unify ab initio treatments of bound and unbound states. The position-space quantum Monte Carlo (QMC) methods have a long history of successful bound-state calculations in light systems but have seen minimal implementation in unbound systems. Here, we introduce a numerical method to improve the efficiency and accuracy of unbound-state calculations in QMC. As an initial application, we compute scattering observables for the smallest system available to probe three-body forces, the neutron-triton system, using variational Monte Carlo (VMC) wave functions. The method involves inferring long-range amplitudes in the wave function from integrals over the short-range region where all the particles interact. This approach using integral relations is well established in the literature; here, we develop it for the QMC framework. We validate our approach with a consistency check between short-range spectroscopic overlap functions computed from direct evaluation and from the integral relations; scattering amplitudes are long-range asymptotics of those overlaps. Comparison against published benchmark calculations using the same potential demonstrates that when applied to the current VMC wave functions, the integral method produces more accurate scattering observables than direct evaluation from the same variational wave function. However, it still differs noticeably from the exact results. Using additional interactions, we then present phase shifts and mixing parameters for the n + 3 H system. In particular, we present one of the first applications of the Norfolk family of local coordinate-space chiral potentials in unbound systems of A > 2. The Norfolk results accurately describe s-wave scattering but predict p-wave cross sections too large. Compared with previous QMC scattering calculations, the integral method avoids difficulties associated with the precise computation of energy differences and with convergence outside the interaction region, which is particularly severe in the variational calculation. Application of the integral method here paves the way for its use in Green's function Monte Carlo (GFMC) calculations. In GFMC, the wave functions are more accurate, but the high-precision convergence of their tails is slow, and there are additional difficulties in reading out amplitudes. Here, the integral methods will address both of those remaining problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Floating Block Method for Quantum Monte Carlo Simulations

Quantum Monte Carlo simulations are powerful and versatile tools for the quantum many-body problem. In addition to the usual calculations of energies and eigenstate observables, quantum Monte Carlo simulations can in principle be used to build fast and accurate many-body emulators using eigenvector continuation or design time-dependent Hamiltonians for adiabatic quantum computing. Furthermore, these new applications require something that is missing from the published literature, an efficient quantum Monte Carlo scheme for computing the inner product of ground state eigenvectors corresponding to different Hamiltonians. In this work, we introduce an algorithm called the floating block method, which solves the problem by performing Euclidean time evolution with two different Hamiltonians and interleaving the corresponding time blocks. We use the floating block method and nuclear lattice simulations to build eigenvector continuation emulators for energies of 4 He, 8 Be, 12 C, and 16 O nuclei over a range of local and nonlocal interaction couplings. From the emulator data, we identify the quantum phase transition line from a Bose gas of alpha particles to a nuclear liquid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crossing the mesoscale no-man s land via parallel kinetic Monte Carlo.

The kinetic Monte Carlo method and its variants are powerful tools for modeling materials at the mesoscale, meaning at length and time scales in between the atomic and continuum. We have completed a 3 year LDRD project with the goal of developing a parallel kinetic Monte Carlo capability and applying it to materials modeling problems of interest to Sandia. In this report we give an overview of the methods and algorithms developed, and describe our new open-source code called SPPARKS, for Stochastic Parallel PARticle Kinetic Simulator. We also highlight the development of several Monte Carlo models in SPPARKS for specific materials modeling applications, including grain growth, bubble formation, diffusion in nanoporous materials, defect formation in erbium hydrides, and surface growth and evolution.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo capabilities of the SCALE code system

SCALE is a broadly used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. For more than 30 years, regulators, licensees, and research institutions around the world have used SCALE for nuclear safety analysis and design. SCALE provides a “plug-and-play” framework that includes three deterministic and three Monte Carlo radiation transport solvers that can be selected based on the desired solution, including hybrid deterministic/Monte Carlo simulations. SCALE includes the latest nuclear data libraries for continuous-energy and multigroup radiation transport as well as activation, depletion, and decay calculations. SCALE’s graphical user interfaces assist with accurate system modeling, visualization, and convenient access to desired results. SCALE 6.2 will provide several new capabilities and significant improvements in many existing features, especially with expanded continuous-energy Monte Carlo capabilities for criticality safety, shielding, depletion, and sensitivity and uncertainty analysis. Finally, an overview of the Monte Carlo capabilities of SCALE is provided here, with emphasis on new features for SCALE 6.2.

97 MATHEMATICS AND COMPUTING↗

Performance and accuracy of criticality calculations performed using WARP – A framework for continuous energy Monte Carlo neutron transport in general 3D geometries on GPUs

In this companion paper to "Algorithmic Choices in WARP - A Framework for Continuous Energy Monte Carlo Neutron Transport in General 3D Geometries on GPUs" (doi:10.1016/j.anucene.2014.10.039), the WARP Monte Carlo neutron transport framework for graphics processing units (GPUs) is benchmarked against production-level central processing unit (CPU) Monte Carlo neutron transport codes for both performance and accuracy. We compare neutron flux spectra, multiplication factors, runtimes, speedup factors, and costs of various GPU and CPU platforms running either WARP, Serpent 2.1.24, or MCNP 6.1. WARP compares well with the results of the production-level codes, and it is shown that on the newest hardware considered, GPU platforms running WARP are between 0.8 to 7.6 times as fast as CPU platforms running production codes. Also, the GPU platforms running WARP were between 15% and 50% as expensive to purchase and between 80% to 90% as expensive to operate as equivalent CPU platforms performing at an equal simulation rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclide Depletion Capabilities in the Shift Monte Carlo Code

A new depletion capability has been developed in the Exnihilo radiation transport code suite. This capability enables massively parallel domain-decomposed coupling between the Shift continuous-energy Monte Carlo solver and the nuclide depletion solvers in ORIGEN to perform high-performance Monte Carlo depletion calculations. This paper describes this new depletion capability and discusses its various features, including a multi-level parallel decomposition, high-order transport-depletion coupling, and energy-integrated power renormalization. Several test problems are presented to validate the new capability against other Monte Carlo depletion codes, and the parallel performance of the new capability is analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A quasi-static Monte Carlo algorithm for the simulation of sub-prompt critical transients

A pseudo-time-dependent Monte Carlo algorithm suitable for simulating thermal reactor transients with timescales on the order of seconds is presented. An initial experimental implementation has been written into the Monte Carlo Application ToolKit (MCATK) developed at Los Alamos National Laboratory. The algorithm is essentially a combination of the fully time-dependent Monte Carlo algorithm, including the explicit simulation of delayed neutron precursors, and a quasi-static algorithm that does not use the point-kinetics equations. The fully time-dependent calculation is performed for some number of inactive and active micro time steps. The dynamic reactor time constant and delayed neutron precursor production rates are calculated directly from the active cycles, rather than from point-kinetics parameters. These quantities are then used to advance the neutron population and delayed neutron precursors forward in time across a macro time step. As a result, the method is applied to the C5G7-TD benchmark operating in steady state and in transient mode.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evolution of microstructures in radiation fields using a coupled binary-collision Monte Carlo phase field approach

The simulation of radiation effects in materials broadly falls into two categories. At short time and length scales lies the modeling of primary radiation damage, such as point defect creation, energy deposition, and ballistic mixing. This is followed by the modeling at longer time scales of thermally activated microstructure evolution and defect reactions, such as recombination, clustering, and coarsening. The binary collision Monte Carlo method is an established, numerically efficient method for the computation of primary radiation damage. Conversely, the phase field method is a state of the art method for microstructure evolution on longer time and length scales. Here we present a concurrent coupling of these two methods, overcoming the difference between the discrete object Monte Carlo paradigm for primary radiation damage and the continuum field variable approach for microstructure evolution. The coupling is bidirectional, in which the microstructure evolution in the MOOSE finite element frame- work provides the spatial scattering data set for the charged particle trans- port and receives point defect, mass transport, and heat source terms from the simulated collision cascades that contribute to the field variable evolution. The concurrent coupling scheme is implemented in the code Magpie and demonstrated by investigating patterning for a model irradiated immiscible binary alloy. The results from the coupled binary collision Monte Carlo/phase field simulations reproduce the results of analytical models for phase separation, phase mixing, and patterning, supporting the approach and indicating its utility for modeling real materials systems.

36 MATERIALS SCIENCE↗

The F-t-Pj-RG method: An adjacent-rolling-windows based steady-state detection technique for application to kinetic Monte Carlo simulations

A window-based steady-state detection algorithm has been developed for application to kinetic Monte Carlo simulation data. The algorithm, termed F-t-Pj-RG sequentially applies an F-test, a t-test, and a projection test on adjacent windows of the data while rolling (or shifting) and growing the windows when any of the tests fail. In aggregate, the algorithm is able to (a) automatically reject the warm-up period as not being at steady-state, as well as (b) determine an appropriate window size for converged statistics when sampling the data, which is necessary for detection of steady-state, and (c) detect steady-state within a particular tolerance. The last step, the projection test, is actually an oscillating-slope projection test, and is performed on j sequential data windows (i.e., more than two adjacent windows). It requires more than simply being within the user defined tolerance: the oscillating-slope projection test includes a condition that the slope must oscillate around zero when 2, which is an additional indication of steady-state. When all three tests are passed, the F-t-Pj test is passed, indicating that the prerequisites of steady-state detection have been met and also that conditions consistent with the definition of steady-state have been realized. This algorithm is applied to a variety of data sets that correspond to the diverse type of data trends that can be produced by kinetic Monte Carlo simulations. The algorithm is shown to be robust in its ability to handle differing functional forms, and is able to detect steady-state with low computational cost. Finally, the low computational cost of this method and its robustness towards varied data trends make it suitable for on-the-fly use in kinetic Monte Carlo simulations.

97 MATHEMATICS AND COMPUTING↗

Patient-Specific Monte Carlo Dose Calculations for High-Dose-Rate Endorectal Brachytherapy With Shielded Intracavitary Applicator

Purpose: An integrated software platform was developed to perform a patient-specific dosimetric study on high-dose-rate {sup 192}Ir endorectal brachytherapy. Monte Carlo techniques were used to examine the perturbation effects of an eight-channel intracavitary applicator with shielding and a liquid-inflatable balloon. Such effects are ignored in conventional treatment planning systems that assume water-equivalent geometries. Methods and Materials: A total of 40 Task Group 43-based rectal patient plans were calculated using the PTRAN{sub C}T Monte Carlo photon transport code. The silicone applicator, tungsten or lead shielding, contrast solution-filled balloon, and patient anatomy were included in the simulations. The dose to water and dose to medium were scored separately. The effects of heterogeneities and uncertainties in source positioning were examined. A superposition calculation method using pregenerated Monte Carlo dose distributions about the shielded applicator in water was developed and validated for efficient treatment planning purposes. Results: On average, metal shielding decreases the mean dose to the contralateral normal tissues by 24% and reduces the target volume covered by the prescribed dose from 97% to 94%. Tissue heterogeneities contribute to dose differences of <1% relative to the prescribed dose. The differences in the dose volume indices between dose to water and dose to medium-based calculations were <1% for soft tissues, <2% for bone marrow, and >20% for cortical bone. A longitudinal shift of {+-}2.5 mm and a rotational shift of {+-}15{sup o} in applicator insertion reduced the target volume receiving the prescribed dose by {<=}4%. Conclusion: The shielded applicator improved dose conformity and normal tissue sparing; however, Task Group 43-based treatment planning might compromise target coverage by not accounting for shielding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 32}P Brachytherapy Conformal Source Model RIC-100 for High-Dose-Rate Treatment of Superficial Disease: Monte Carlo Calculations, Diode Measurements, and Clinical Implementation

Purpose: A novel {sup 32}P brachytherapy source has been in use at our institution intraoperatively for temporary radiation therapy of the spinal dura and other localized tumors. We describe the dosimetry and clinical implementation of the source. Methods and Materials: Dosimetric evaluation for the source was done with a complete set of MCNP5 Monte Carlo calculations preceding clinical implementation. In addition, the depth dose curve and dose rate were measured by use of an electron field diode to verify the Monte Carlo calculations. Calibration procedures using the diode in a custom-designed phantom to provide an absolute dose calibration and to check dose uniformity across the source area for each source before treatment were established. Results: Good agreement was established between the Monte Carlo calculations and diode measurements. Quality assurance measurements results are provided for about 100 sources used to date. Clinical source calibrations were usually within 10% of manufacturer specifications. Procedures for safe handling of the source are described. Discussion: Clinical considerations for using the source are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A comparison of generalized hybrid Monte Carlo methods with and without momentum flip

The generalized hybrid Monte Carlo (GHMC) method combines Metropolis corrected constant energy simulations with a partial random refreshment step in the particle momenta. The standard detailed balance condition requires that momenta are negated upon rejection of a molecular dynamics proposal step. The implication is a trajectory reversal upon rejection, which is undesirable when interpreting GHMC as thermostated molecular dynamics. We show that a modified detailed balance condition can be used to implement GHMC without momentum flips. The same modification can be applied to the generalized shadow hybrid Monte Carlo (GSHMC) method. Numerical results indicate that GHMC/GSHMC implementations with momentum flip display a favorable behavior in terms of sampling efficiency, i.e., the traditional GHMC/GSHMC implementations with momentum flip got the advantage of a higher acceptance rate and faster decorrelation of Monte Carlo samples. The difference is more pronounced for GHMC. We also numerically investigate the behavior of the GHMC method as a Langevin-type thermostat. We find that the GHMC method without momentum flip interferes less with the underlying stochastic molecular dynamics in terms of autocorrelation functions and it to be preferred over the GHMC method with momentum flip. The same finding applies to GSHMC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coarse-grained computation for particle coagulation and sintering processes by linking Quadrature Method of Moments with Monte-Carlo

The study of particle coagulation and sintering processes is important in a variety of research studies ranging from cell fusion and dust motion to aerosol formation applications. These processes are traditionally simulated using either Monte-Carlo methods or integro-differential equations for particle number density functions. In this paper, we present a computational technique for cases where we believe that accurate closed evolution equations for a finite number of moments of the density function exist in principle, but are not explicitly available. The so-called equation-free computational framework is then employed to numerically obtain the solution of these unavailable closed moment equations by exploiting (through intelligent design of computational experiments) the corresponding fine-scale (here, Monte-Carlo) simulation. We illustrate the use of this method by accelerating the computation of evolving moments of uni- and bivariate particle coagulation and sintering through short simulation bursts of a constant-number Monte-Carlo scheme.

97 MATHEMATICS AND COMPUTING↗

An alternative Monte Carlo approach to the thermal radiative transfer problem

The usual Monte Carlo approach to the thermal radiative transfer problem is to view Monte Carlo as a solution technique for the nonlinear thermal radiative transfer equations. The equations contain time derivatives which are approximated by introducing small time steps. An alternative approach avoids time steps by using Monte Carlo to directly sample the time at which the next event occurs. That is, the time is advanced on a natural event-by-event basis rather than by introducing an artificial time step.

97 MATHEMATICS AND COMPUTING↗