Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components
The thermal inactivation curve for Bacillus subtilis var. niger spores on the Viking lander is examined. Tests were conducted at 113 C and 25% RH, and over a wide range of temperatures using .001% RH and additions of P2O5 to dry the environment. Results show the 25% RH environment did not significantly reduce the survival curve, while the survival curves for spores treated under the drier .001% RH environment was reduced by a factor of 3.