Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METASTASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Risk of Leptomeningeal Disease in Patients Treated With Stereotactic Radiosurgery Targeting the Postoperative Resection Cavity for Brain Metastases

Purpose: We sought to determine the risk of leptomeningeal disease (LMD) in patients treated with stereotactic radiosurgery (SRS) targeting the postsurgical resection cavity of a brain metastasis, deferring whole-brain radiation therapy (WBRT) in all patients. Methods and Materials: We retrospectively reviewed 175 brain metastasis resection cavities in 165 patients treated from 1998 to 2011 with postoperative SRS. The cumulative incidence rates, with death as a competing risk, of LMD, local failure (LF), and distant brain parenchymal failure (DF) were estimated. Variables associated with LMD were evaluated, including LF, DF, posterior fossa location, resection type (en-bloc vs piecemeal or unknown), and histology (lung, colon, breast, melanoma, gynecologic, other). Results: With a median follow-up of 12 months (range, 1-157 months), median overall survival was 17 months. Twenty-one of 165 patients (13%) developed LMD at a median of 5 months (range, 2-33 months) following SRS. The 1-year cumulative incidence rates, with death as a competing risk, were 10% (95% confidence interval [CI], 6%-15%) for developing LF, 54% (95% CI, 46%-61%) for DF, and 11% (95% CI, 7%-17%) for LMD. On univariate analysis, only breast cancer histology (hazard ratio, 2.96) was associated with an increased risk of LMD. The 1-year cumulative incidence of LMD was 24% (95% CI, 9%-41%) for breast cancer compared to 9% (95% CI, 5%-14%) for non-breast histology (P=.004). Conclusions: In patients treated with SRS targeting the postoperative cavity following resection, those with breast cancer histology were at higher risk of LMD. It is unknown whether the inclusion of whole-brain irradiation or novel strategies such as preresection SRS would improve this risk or if the rate of LMD is inherently higher with breast histology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Genomic Prostate Cancer Classifier Predicts Biochemical Failure and Metastases in Patients After Postoperative Radiation Therapy

Purpose: To test the hypothesis that a genomic classifier (GC) would predict biochemical failure (BF) and distant metastasis (DM) in men receiving radiation therapy (RT) after radical prostatectomy (RP). Methods and Materials: Among patients who underwent post-RP RT, 139 were identified for pT3 or positive margin, who did not receive neoadjuvant hormones and had paraffin-embedded specimens. Ribonucleic acid was extracted from the highest Gleason grade focus and applied to a high-density-oligonucleotide microarray. Receiver operating characteristic, calibration, cumulative incidence, and Cox regression analyses were performed to assess GC performance for predicting BF and DM after post-RP RT in comparison with clinical nomograms. Results: The area under the receiver operating characteristic curve of the Stephenson model was 0.70 for both BF and DM, with addition of GC significantly improving area under the receiver operating characteristic curve to 0.78 and 0.80, respectively. Stratified by GC risk groups, 8-year cumulative incidence was 21%, 48%, and 81% for BF (P<.0001) and for DM was 0, 12%, and 17% (P=.032) for low, intermediate, and high GC, respectively. In multivariable analysis, patients with high GC had a hazard ratio of 8.1 and 14.3 for BF and DM. In patients with intermediate or high GC, those irradiated with undetectable prostate-specific antigen (PSA ≤0.2 ng/mL) had median BF survival of >8 years, compared with <4 years for patients with detectable PSA (>0.2 ng/mL) before initiation of RT. At 8 years, the DM cumulative incidence for patients with high GC and RT with undetectable PSA was 3%, compared with 23% with detectable PSA (P=.03). No outcome differences were observed for low GC between the treatment groups. Conclusion: The GC predicted BF and metastasis after post-RP irradiation. Patients with lower GC risk may benefit from delayed RT, as opposed to those with higher GC; however, this needs prospective validation. Genomic-based models may be useful for improved decision-making for treatment of high-risk prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping Patterns of Ipsilateral Supraclavicular Nodal Metastases in Breast Cancer: Rethinking the Clinical Target Volume for High-risk Patients

Purpose: To map the location of metastatic supraclavicular (SCV) lymph nodes (LNMs) in breast cancer patients with SCV node involvement and determine whether and where the radiation therapy clinical target volume (CTV) of this region could be modified in high-risk subsets. Methods and Materials: Fifty-five patients with metastatic SCV LNMs were eligible for geographic mapping and atlas coverage analysis. All LNMs and their epicenters were registered proportionally by referencing the surrounding landmarks onto simulation computed tomography images of a standard patient. CTVs based on selected SCV atlases, including the one by the Radiation Therapy Oncology Group (RTOG) were contoured. A modified SCV CTV was tried and shown to have better involved-node coverage and thus theoretically improved prophylaxis in this setting. Results: A total of 50 (91%) and 45 (81.8%) patients had LNMs in the medial and lateral SCV subregions, respectively. Also, 36 patients (65.5%) had LNMs located at the junction of the jugular-subclavian veins. All nodes were covered in only 25.5% to 41.8% of patients by different atlases. The RTOG atlas covered all nodes in 25.5% of patients. Stratified by the nodes in all the patients as a whole, 49.2% to 81.3% were covered, and the RTOG atlas covered 62.6%. The lateral and posterior borders were the most overlooked locations. Modification by extending the borders to natural anatomic barriers allowed the new CTV to cover all the nodes in 81.8% of patients and encompass 96.1% of all the nodes. Conclusions: According to the distribution of SCV LNMs, the extent of existing atlases might not be adequate for potential metastatic sites in certain groups of patients. The extension of the lateral and posterior CTV borders in high-risk or recurrent patients might be a reasonable approach for increasing coverage. However, additional data in more homogeneous populations with localized disease are needed before routine application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Programmatic Comparison and Dissemination of an Audit of Single-fraction Radiation Therapy Prescribing Practices for Bone Metastases is Associated with a Meaningful and Lasting Change in Practice on a Population Level

There is ample evidence that single-fraction radiation therapy (SFRT) is as efficacious as more costly and morbid multifraction regimens. We previously demonstrated that an audit-based intervention increased the use of SFRT in all regional cancer centers the following year. However, other investigators have demonstrated that interventions were only associated with a transient 1-year change in prescribing practices. We sought to determine whether our intervention resulted in a more lasting impact.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Mediastinal and Hilar Lymph Node Metastases

Stereotactic body radiation therapy (SBRT) to metastatic mediastinal and hilar lymphadenopathy (MHL) is challenging owing to the proximity of centrally located organs-at-risk. As limited data exist on the safety and efficacy of SBRT for MHL, a retrospective review of clinical outcomes was conducted from a large academic center.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of a Phase 1 Dose-Escalation Trial and Subsequent Institutional Experience of Single-Fraction Stereotactic Ablative Radiation Therapy for Liver Metastases

We report long-term outcomes from our phase 1 dose-escalation study to determine the maximum tolerated dose of single-fraction liver SABR pooled with our subsequent single institutional experience with patients treated postprotocol at the highest dose level (40 Gy) established from the phase 1 study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases

To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV), correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the preferential choice for the body + pedicle-type lesions. This study suggests further clinical investigations with longer follow-up for these studied cases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of brain metastases radiotherapy with TomoHDA

An upgrade of the helical tomotherapy technology by introducing variable fan-field width (dynamic jaws) reduced the penumbra in superior-inferior direction for the target. Possible implementation of this upgrade even for the cases of the targets with different dose prescriptions is proposed. An example of brain metastasis in proximity to the optical apparatus in need of the whole brain irradiation of 30 Gy and higher dose to the lesion is considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases

Purpose: Volumetric modulated arc therapy (VMAT) is a rotational delivery technique in which MLC shapes, dose rate, and gantry rotation speed are optimized to produce conformal dose distributions. The aim of this work is to develop a beam projection method for deriving the optimal table and collimator angles for multilesion treatment planning. Methods: The method consists of four steps. The first step is to define the vector of beam-eye-view (BEV)-Y-axis in the treatment planning CT coordinates. The second step is to project each target onto the BEV-Y-axis vector. In the third step, the best table and collimator angle are found with a brute-force optimization technique that minimizes MLC leaf sharing between lesions. The fourth step is to generate an optimized VMAT plan with appropriate table/collimator angles and evaluate the plan quality. Results: The authors tested the method on three example cases with targets of various locations in the brain and sizes ranging from 1.18 to 17.86 cm{sup 3}. Applying the optimized geometric parameter to generate VMAT plan, a reduction of the 12 Gy volume was more than 6.1% for all cases; the plan homogeneity (D{sub 2%}-D{sub 95%}) was improved from 5.88{+-}1.21 to 5.21{+-}0.93 Gy vs a VMAT plan with the manufacturer recommended table and collimator angles. Conclusions: The authors conclude that the use of the projection method minimizes the sharing of MLC leaves between lesions and improves the plan quality for multilesion VMAT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-224: Considerations for the Proper Treatment of Multiple Cranial Metastases with Single Isocenter Volumetric Modulated Arc Therapy

Purpose: To investigate some limitations of single isocenter VMAT for cranial multiple met cases. Methods: A single isocenter VMAT plan (Varian, Eclipse AAA10 commissioned down to 1 cm) was designed for two 7mm diameter spherical targets in a rectangular Solid Water (Gammex) phantom. The targets were separated by a distance of 6cm and the isocenter was centered in one of the targets. The plan was delivered (Varian, Truebeam STx) three separate times with different artificial couch angle errors of 0, 0.5 and 1 degree. The coronal dose distributions were measured with calibrated EBT3 film placed at mid-phantom. EBT3 film dosimetry was also performed on the delivery of separate multiple arc vmat plans to targets below 6mm in diameter. Results: Measurements of the sup/inf dose profiles through the high dose distributions show no movement of the central axis high dose region and shifts of the high dose region intended for the off-axis target. For the 1 degree rotation error, the high dose region was shifted 1.04mm from the target. This corresponds to the shift expected from triangulation (60mmxTan(1deg)=1.047mm). Furthermore, a streak of 10% interleaf leakage dose was observed and is likely a Result of the off axis target traveling a wide path such that a long length of MLC is exposed for the whole arc. The calculated dose was about 10% to 15% low compared to that measured on film for a 5mm diameter target. Conclusion: Judicious use of additional margin for off axis targets or limits on the span of multiple mets treated with one isocenter is recommended. The magnitude of the margin should be based on the rotational errors evaluated for the positioning system and the distance of the target from the isocenter. A lower limit of lesion size that can be accurately treated with VMAT should be determined.

60 APPLIED LIFE SCIENCES↗

SU-E-T-331: Dosimetric Impact of Multileaf Collimator Leaf Width On Stereotactic Radiosurgery (SRS) RapidArc Treatment Plans for Single and Multiple Brain Metastases

Purpose: To determine the effects of multileaf collimator (MLC) leaf width on normal-brain-tissue doses and dose conformity of SRS RapidArc treatment plans for brain tumors. Methods: Ten patients with 24 intracranial tumors (seven with 1–2 and three with 4–6 lesions) were planned using RapidArc for both Varian Millennium 120 MLC (5 mm leaf width) and high definition (HD) MLC (2.5 mm leaf width). Between 2 and 8 arcs were used with two full coplanar arcs and the rest non-coplanar half arcs. 6 MV beams were used and plans were optimized with a high priority to the Normal Tissue Objective (to achieve dose conformity and sharp dose fall-off) and normal brain tissue. Calculation was done using AAA on a 1 mm grid size. The prescription dose ranged from 14–22 Gy. Plans were normalized such that 99% of the target received the prescription dose. Identical beam geometries, optimizations, calculations, and normalizations were used for both plans. Paddick Conformity Index (PCI), V4, V8 and V12 Gy for normal brain tissue and Integral Dose were used for analysis. Results: In all cases, HD MLC plans performed better in sparing normal brain tissue, achieving a higher PCI with a lower Integral Dose. The average PCI for all 24 targets was 0.75±0.23 and 0.70±0.23 (p ≤0.0015) for HD MLC and Millennium MLC plans, respectively. The average ratio of normal brain doses for Millennium MLC to HD MLC plans was 1.30±0.16, 1.27±0.15, and 1.31±0.18 for the V4, V8, and V12, respectively. The differences in normal brain dose for all criteria were statistically significant with p-value < 0.02. On average Millennium MLC plans had a 16% higher integral dose than HD MLC plans. Conclusion: Significantly better dose conformity with reduced volume of normal brain tissue and integral dose was achieved with HD MLC plans compared to Millennium MLC plans.

60 APPLIED LIFE SCIENCES↗

SU-F-J-224: Impact of 4D PET/CT On PERCIST Classification of Lung and Liver Metastases in NSLC and Colorectal Cancer

Purpose: To quantify the impact of 4D PET/CT on PERCIST metrics in lung and liver tumors in NSCLC and colorectal cancer patients. Methods: 32 patients presenting lung or liver tumors of 1–3 cm size affected by respiratory motion were scanned on a GE Discovery 690 PET/CT. The bed position with lesion(s) affected by motion was acquired in a 12 minute PET LIST mode and unlisted into 8 bins with respiratory gating. Three different CT maps were used for attenuation correction: a clinical helical CT (CT-clin), an average CT (CT-ave), and an 8-phase 4D CINE CT (CT-cine). All reconstructions were 3D OSEM, 2 iterations, 24 subsets, 6.4 Gaussian filtration, 192×192 matrix, non-TOF, and non-PSF. Reconstructions using CT-clin and CT-ave used only 3 out of the 12 minutes of the data (clinical protocol); all 12 minutes were used for the CT-cine reconstruction. The percent change of SUVbw-peak and SUVbw-max was calculated between PET-CTclin and PET-CTave. The same percent change was also calculated between PET-CTclin and PET-CTcine in each of the 8 bins and in the average of all bins. A 30% difference from PET-CTclin classified lesions as progressive metabolic disease (PMD) using maximum bin value and the average of eight bin values. Results: 30 lesions in 25 patients were evaluated. Using the bin with maximum SUVbw-peak and SUVbw-max difference, 4 and 13 lesions were classified as PMD, respectively. Using the average bin values for SUVbw-peak and SUVbw-max, 3 and 6 lesions were classified as PMD, respectively. Using PET-CTave values for SUVbw-peak and SUVbw-max, 4 and 3 lesions were classified as PMD, respectively. Conclusion: These results suggest that response evaluation in 4D PET/CT is dependent on SUV measurement (SUVpeak vs. SUVmax), number of bins (single or average), and the CT map used for attenuation correction.

60 APPLIED LIFE SCIENCES↗

SU-F-T-629: Effect of Multi-Leaf Collimator (MLC) Width On Plan Quality of Single-Isocenter VMAT Intracranial Stereotactic Radiosurgery for Multiple Metastases

Purpose: Single-isocenter VMAT has been shown able to create high quality plans for complex intracranial multiple metastasis SRS cases. Linacs capable of the technique are typically outfitted with an MLC that consists of a combination of 5 mm and 10 mm leaves (standard) or 2.5 mm and 5 mm leaves (high-definition). In this study, we test the hypothesis that thinner collimator leaves are associated with improved plan quality. Methods: Ten multiple metastasis cases were identified and planned for VMAT SRS using a 10 MV flattening filter free beam. Plans were created for a standard (std) and a high-definition (HD) MLC. Published values for leaf transmission factor and dosimetric leaf gap were utilized. All other parameters were invariant. Conformity (plan and individual target), moderate isodose spill (V50%), and low isodose spill (mean brain dose) were selected for analysis. Results: Compared to standard MLC, HD-MLC improved overall plan conformity (median: Paddick CI-HD = 0.83, Paddick CI-std = 0.79; p = 0.004 and median: RTOG CI-HD =1.18, RTOG CI-std =1.24; p = 0.01 ), improved individual lesion conformity (median: Paddick CI-HD,i =0.77, Paddick CI-std,i =0.72; p < 0.001 and median: RTOG CI-HD,i = 1.28, RTOG CI-std,i =1.35; p < 0.001), improved moderate isodose spill (median: V50%-HD = 37.0 cc, V50%-std = 45.7 cc; p = 0.002), and improved low dose spill (median: dmean-HD = 2.90 Gy, dmean-std = 3.19 Gy; p = 0.002). Conclusion: For the single-isocenter VMAT SRS of multiple metastasis plans examined, use of HD-MLC modestly improved conformity, moderate isodose, and low isodose spill compared to standard MLC. However, in all cases we were able to generate clinically acceptable plans with the standard MLC. More work is need to further quantify the difference in cases with higher numbers of small targets and to better understand any potential clinical significance. This research was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗