High Resolution Fast-Neutron Time-Encoded Imaging using an Asymmetric Mask.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Methods of manufacturing a semiconductor device, and resulting semiconductor device are described. In an example, the method for manufacturing a semiconductor device include forming a semiconductor region and forming a metal seed region over the semiconductor region. The method can include placing a conductive strip over a first portion of the metal region, where the conductive strip is formed over the semiconductor region. The method can include bonding a contacting portion of the conductive strip to the first portion the metal region. The method can include etching a second portion of the metal region and where the conductive strip inhibits etching of the first portion of the metal region. In an example, the conductive strip can have a coating. In one example, the semiconductor device can be a solar cell.
Explore the source record for details and available documents.
We describe the fabrication of silicon three dimensional photonic crystals using polymer templates defined by a single step, two-photon exposure through a layer of photopolymer with relief molded on its surface. The resulting crystals exhibit high structural quality over large areas, displaying geometries consistent with calculation. Spectroscopic measurements of transmission and reflection through the silicon and polymer structures reveal excellent optical properties, approaching properties predicted by simulations that assume ideal layouts.
Aerial images for isolated defects and the interactions of defects with features are compared between the Actinic Inspection Tool (AIT) at Lawrence Berkeley National Laboratory (LBNL) and the fast EUV simulation program RADICAL. Comparisons between AIT images from August 2007 and RADICAL simulations are used to extract aberrations. At this time astigmatism was the dominant aberration with a value of 0.55 waves RMS. Significant improvements in the imaging performance of the AIT were made between August 2007 and December 2008. A good match will be shown between the most recent AIT images and RADICAL simulations without aberrations. These comparisons will demonstrate that a large defect, in this case 7nm tall on the surface, is still printable even if it is centered under the absorber line. These comparisons also suggest that the minimum defect size is between 1.5nm and 0.8nm surface height because a 1.5nm defect was printable but a 0.8nm was not. Finally, the image of a buried defect near an absorber line through focus will demonstrate an inversion in the effect of the defect from a protrusion of the dark line into the space to a protrusion of the space into the line.
Sonar and speech techniques have been investigated to improve functionality and enable handheld and other man-portable, mobile, and portal systems to positively detect and identify illicit nuclear materials, with minimal data and with minimal false positives and false negatives. RadSonar isotope detection and identification is an algorithm development project funded by NA-22 and employing the resources of Savannah River National Laboratory and three University Laboratories (JHU-APL, UT-ARL, and UW-APL). Algorithms have been developed that improve the probability of detection and decrease the number of false positives and negatives. Two algorithms have been developed and tested. The first algorithm uses support vector machine (SVM) classifiers to determine the most prevalent nuclide(s) in a spectrum. It then uses a constrained weighted least squares fit to estimate and remove the contribution of these nuclide(s) to the spectrum, iterating classification and fitting until there is nothing of significance left. If any Special Nuclear Materials (SNMs) were detected in this process, a second tier of more stringent classifiers are used to make the final SNM alert decision. The second algorithm is looking at identifying existing feature sets that would be relevant in the radioisotope identification context. The underlying philosophy here is to identify parallels between the physics and/or the structures present in the data for the two applications (speech analysis and gamma spectroscopy). The expectation is that similar approaches may work in both cases. The mel-frequency cepstral representation of spectra is widely used in speech, particularly for two reasons: approximation of the response of the human ear, and simplicity of channel effect separation (in this context, a 'channel' is a method of signal transport that affects the signal, examples being vocal tract shape, room echoes, and microphone response). Measured and simulated gamma-ray spectra from a hand-held Radioisotope Identification Device were used to evaluate the algorithms. This paper will present and discuss results of the Test and Evaluation performed on two algorithms produced from the project.
The introduction of EUV lithography into high-volume semiconductor manufacturing this year represents a monumental milestone for EUV technology. After nearly 30 years of development, the EUV research community has overcome many of the key obstacles required to enable the long-awaited integration of EUV lithography into the lab. These obstacles have included: the development of a stable, high-powered EUV source to ensure adequate exposure tool reliability; controlling EUV mask defects and mask contamination; and the development of EUV resists with adequate sensitivity, resolution, and line width roughness to meet the tolerances required for high-volume manufacturing. As EUV moves into its second generation, there will be new challenges facing the community as it works to push EUV technology into the future. Smaller feature sizes will be achieved using higher numerical aperture optics, which are planned to have an anamorphic geometry (asymmetric magnification and numerical aperture between horizontal and vertical axes) to overcome 3D effects at the mask. This new geometry and its larger angle ranges make understanding mask absorber and multilayer effects all the more important. New methods for high-NA wavefront metrology need to be tested to ensure that these optical systems can be aligned to operate with minimal aberrations. Mask defects need to continue to be studied, and the inclusion of EUV pellicles in the roadmap requires that mask inspection and review systems adapt accordingly. Finally, new resists must be developed to support the increased resolution of feature sizes below 8 nm half pitch. The Center for X-ray Optics (CXRO) at Berkeley Lab has been a leader in EUV research for the past 25 years. Leveraging 13.5 nm EUV light from the Advanced Light Source synchrotron facility, CXRO is home to several EUV and soft X-ray (SXR) research tools that have provided important insights into EUV resists, masks, and coatings. The 0.3 NA Microfield exposure tool (MET) and Dose Calibration Tool (DCT) have played an instrumental role in the development of the current generation of high-resolution EUV resists. The Actinic Inspection Tool (AIT) and its successor, SHARP, have enabled aerial image analysis, providing key insights into mask defects, 3D mask effects, illumination, and aberrations. And the CXRO Reflectometer continues to be the industry standard in multilayer coating and EUV mask scattering metrology. To address the new challenges facing the next generation of EUV lithography, CXRO has upgraded its suite of EUV research tools. The 0.5 NA MET5 is a newly commissioned projection lithography tool that is capable of printing feature sizes down to 8 nm half pitch. A new radiation chemistry program is deploying several techniques aimed at dissecting the role of primary photoelectrons and secondary electrons in EUV resists. The SHARP microscope has been outfitted with anamorphic zone plate lenses that can emulate the geometry of next-generation EUV scanners, and the reflectometer has been applied to new scattering experiments for the purpose of understanding the 3D effects of EUV mask multilayers, as well as determining mask properties using scattering profiles. In parallel with these tools, the CXRO High-NA Wavefront Sensing Program is developing high-resolution wavefront sensors suitable for measuring aberrations at high NA. This article presents an overview of these programs and describes how they will address the primary challenges that face the EUV community as it moves to the next generation of EUV lithography.
This code analyzes the reflection geometry of modified Shack-Hartmann Wavefront Sensor (SHWFS) masks, with a focus on the fastrSHWFS designs. It takes a height map of a reflective mask, divides it into sub apertures, removes the global focus term by referencing a central block, and fits local surface planes to each sub aperture. From these fits it computes reflection angles and propagates the corresponding rays downstream to determine spot positions and the overall reflected beam footprint as a function of distance. The implementation is parameterized in sub aperture size, number of sub apertures, focal length, and mask dimensions, so it can be adapted to different mask designs beyond the two current fastrSHWFS masks. The code: Converts mask bitmaps into physical height in microns and reconstructs a focus subtracted mask, divides the mask into a grid of sub apertures and assigns pixel and micron coordinates to each block, excludes user specified unused sub apertures from the analysis, fits a plane to each sub aperture to obtain local surface normals, propagates reflected rays to a range of z positions to compute ray spots and the full reflected beam width, computes the effective mask tilt angle with respect to the incoming beam as a function of propagation distance, and provides helper routines for plotting the grid over the mask and for visualizing the beam geometry. These tools are intended for iterating on fastrSHWFS mask designs and for planning downstream optical layouts, for example choosing lens positions and apertures that capture the reflected beam given known focal plane distances and beam widths.
Purpose: This study aimed to evaluate the feasibility of using a short arterial spin labeling (ASL) scan for calibrating the dynamic susceptibility contrast- (DSC-) MRI in a group of patients with internal carotid artery stenosis. Methods: Six patients with unilateral ICA stenosis enrolled in the study on a 3T clinical MRI scanner. The ASL-cerebral blood flow (-CBF) maps were calculated by averaging different number of dynamic points (N=1-45) acquired by using a Q2TIPS sequence. For DSC perfusion analysis, arterial input function was selected to derive the relative cerebral blood flow (rCBF) map and the delay (Tmax) map. Patient-specific CF was calculated from the mean ASL- and DSC-CBF obtained from three different masks: (1)Tmax< 3s, (2)combined gray matter mask with mask 1, (3)mask 2 with large vessels removed. One CF value was created for each number of averages by using each of the three masks for calibrating the DSC-CBF map. The CF value of the largest number of averages (NL=45) was used to determine the acceptable range(< 10%, <15%, and <20%) of CF values corresponding to the minimally acceptable number of average (NS) for each patient. Results: Comparing DSC CBF maps corrected by CF values of NL (CBFL) in ACA, MCA and PCA territories, all masks resulted in smaller CBF on the ipsilateral side than the contralateral side of the MCA territory(p<.05). The values obtained from mask 1 were significantly different than the mask 3(p<.05). Using mask 3, the medium values of Ns were 4(<10%), 2(<15%) and 2(<20%), with the worst case scenario (maximum Ns) of 25, 4, and 4, respectively. Conclusion: This study found that reliable calibration of DSC-CBF can be achieved from a short pulsed ASL scan. We suggested use a mask based on the Tmax threshold, the inclusion of gray matter only and the exclusion of large vessels for performing the calibration.
Additively manufactured respirators (AMRs) made using rigid plastic can be fitted with repurposed filter media to yield a wearable mask capable of passing a quantitative fit test with criteria set for commercial, N95 health care particulate respirators. This has been verified through an evaluation study assessing AMR masks fabricated using open-source design files and a commercial fused-filament fabrication machine, using N95 filter cloth and a P100 respirator cartridge. A few examples of filter media not designed for human respiratory protection were also evaluated in an AMR mask but did not demonstrate filtering sufficient to pass the N95 test criteria. All attributes of an AMR mask system must be considered during design and when testing performance, including the mask frame, gasket, and the cord used to secure the mask to the face. AMR masks are not the same as commercially available respiratory masks. If AMR masks are used as personal protective equipment (PPE) during a crisis when there is a shortage of regular PPE it is important that wearers are fully informed of the differences, tradeoffs, and risks associated with their use. Quantitative fit testing and proper training on how to don and doff the AMR mask are important to help achieve the best possible outcome when they are used.
Use of masks is a primary tool to prevent the spread of the novel COVID-19 virus resulting from unintentional close contact with infected individuals. However, detailed characterization of the chemical properties and physical structure of common mask materials is lacking in the current literature. In this study, a series of commercial masks and potential mask materials, including 3M Particulate Respirator 8210 N95, a material provided by Oak Ridge National Laboratory Carbon Fiber Technology Facility (ORNL/CFTF), and a Filti Face Mask Material, were characterized by a suite of techniques, including scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and X-ray photoelectron spectroscopy. Wetting properties of the mask materials were quantified by measurements of contact angle with a saliva substitute. Mask pass-through experiments were performed using a dispersed metal oxide nanoparticle suspension to model the SARS-CoV-2 virus, with quantification via spatially resolved X-ray fluorescence mapping. Notably, all mask materials tested provided a strong barrier against respiratory droplet breakthrough. The comparisons and characterizations provided in this study provide useful information when evaluating mask materials for respiratory protection.
In its basic form, phase contrast imaging (PCI) provides line-integrated measurements of electron density fluctuations in plasmas. As turbulent fluctuations in magnetically confined plasmas have wave vectors almost perpendicular to the background magnetic field, the signals scattered by fluctuations from different parts of the PCI line-of-sight (LoS) are spatially separated in focal planes of the plasma. This allows localized PCI measurements by placing a mask in such a plane, to only permit signals from specific parts of the LoS to reach the PCI detectors. The present paper describes modeling and design of localization masks for the PCI system at the Wendelstein 7-X (W7-X) stellarator as well as the first results obtained using the masks in the recent long-pulse W7-X experimental campaign. During this project, we have extended the theory describing the mask response within the Fraunhofer diffraction model. As a novel development, we show from first principles that the mask response is determined by the fraction of power of the scattered beam spots that passes the mask. These insights have been used to select the W7-X mask design, consisting of a circular cutout, allowing the unscattered beam spot to pass the mask, with wedges covering a fixed angular range outside the central cutout. In the recent W7-X experimental campaign, the masks have verified the location of the main turbulence features observed by the PCI system and provided new information about the location of short-wavelength magnetohydrodynamic modes.
As extreme-ultraviolet lithography (EUVL) approaches introduction at the 22-nm half-pitch node, several key aspects of absorber height effects remain unexplored. In particular, sidewall angle (SWA) restrictions based on the height of the mask absorber has not yet been clearly defined. In addition, the effects of absorber height on line-edge roughness (LER) from shadowing has not been examined. We make an initial investigation into how tight SWA constraints are and the extent to which shadow LER alters basic LER. Our approach to SWA aims to find SWA restrictions based on 10% of the total CD error budget (10% of CD). Thus, we allot the SWA budget a {+-}0.2nm tolerance for 22nm half-pitch. New with EUVL is the off-axis illumination system. One potential pitfall that must be carefully monitored is the effect of mask absorber height blocking light from reaching, and therefore, correctly detecting, the base edge position of a feature. While mask features can correctly compensate sizing to target at the wafer, the effects of this shadowing on LER have not yet been investigated. Specifically, shadow LER may exacerbate or mitigate the inherent LER on the mask. Shadowing may also cause a difference in the observed LER on the right and left side of the features. We carefully probe this issue for a range of spatial frequencies. We do rigorous aerial image modeling of mask features with a nominal SWA of 80 degrees and correctly sized to target 22nm features measured at the top, 70nm TaN absorber on a 40 bilayer ML mirror with a 2.5nm Ru cap. Simulations were on a 4X system with an ideal pupil of NA = 0.32, illumination wavelength 13.4nm at 6{sup o} off-axis, and disk source shape with partial coherence factor of {sigma} = 0.50. We first implement a defocus offset to the aerial image so that best focus lies at a nominal zero defocus value. We then calculate the depth of focus (DOF) for which the image-log-slope (ILS) delivers a contrast is greater than 50%, an arbitrary standard for a good quality photoresist to print. Using this DOF, we optimize the process window and adjust the intensity threshold from it's nominal value to a new optimal value. From this optimized intensity threshold, we calculated the aerial image CD through focus for a range of angles around the nominal SWA value. From this, we can find out how much the SWA needs to be constrained by in order to keep the {+-}10% CD error budget tolerance required. For SWA of 80 degrees, we found the nominal SWA is tightly constrained by 0.5 degrees. We repeated these calculations for other nominal values of SWA 85 and 88 degrees, and found that CD sensitivity to nominal SWA is relatively independent. In examining shadow LER, we use FDTD simulations to obtain a rigorous solution for the source intensity immediately after the patterned TaN mask absorber pattern on a 2.5nm Ru capped 40 bilayer ML mirror. The optical system was comprised of an ideal pupil map, NA = 0.32, 13.4nm light at 4{sup o} off-axis, and annular source shape with partial coherence factor of {sigma} = 0.35-0.55. We assumed a 90{sup o} SWA. For the basic 2D shape of the mask that we exactly replicated through height, we created mask LER by generating a sine wave of full amplitude 4nm, equivalent to 4nm LER, (wafer dim.), confined along it's length to precisely CD=22nm, for sine waves with spatial frequencies (full period) of 25, 50, 75, 100, 125, 150, 175, and 200nm (wafer dim.), and illuminated at both {phi}=0{sup o} (perpendicular, shadowing) and {phi}=90{sup o} (parallel, no shadowing). Results show that even off-axis illumination perpendicular to the lines and spaces gives minimal difference between the left and right LER to at most 0.1nm difference at best focus. We followed up this study by repeating the data for a mask designed with 2nm LER with similar results. A plot of the transfer functions for LER of both 2nm and 4nm compared to the contrast of simple 50% duty cycle lines and spaces shows that LER has a unique transfer function as well as a linear response to LER amplitude. In the course of our investigation of SWA, we found that the nominal angle has no effect on process window size, and neither does sensitivity on changing angle alter as a function of nominal angle. For nominal 80{sup o}, 85{sup o}, 88{sup o} SWA, the amount of angle tolerance for 0.2nm change in CD was in total 0.5{sup o}. For shadow LER, we found minimal difference between left and right LER when illuminated perpendicularly to the pattern, to at most 0.1nm LER at best focus. CTFs confirm the uniqueness and linearity of an LER transfer function as opposed to the traditional MTF, as shown in a previous study. In the future we wish to expand our work on shadow LER into the regime where the k{sub 1}-factor of the optic is stressed. In particular, 16nm lines and spaces on an NA = 0.32 optic with off-axis illumination.
Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic thorax phantom, acquired with a second generation dual source CT scanner. The methods differed by the way information on the presence of bone was obtained (either by using an additional, nonenhanced scan or by scanning with two tube voltages at the same time) and by the way the bone was removed from the CTA images (either by masking or subtracting the bone). The phantom contained parts which mimic vessels of various diameters in direct contact with bone. Both a quantitative and qualitative analysis of image quality after bone removal was performed. Image quality was quantified by the contrast-to-noise ratio (CNR) normalized to the square root of the dose (CNRD). At locations where vessels touch bone, the quality of the bone removal and the vessel preservation were visually assessed. The dual energy based methods were assessed with and without the addition of a 0.4 mm tin filter to the high voltage x-ray tube filtration. For each bone removal method, the dose required to obtain a certain CNR after bone removal was compared with the dose of a reference scan with the same CNR but without automated bone removal. The CNRD value of the reference scan was maximized by choosing the lowest tube voltage available. Results: All methods removed the bone completely. CNRD values were higher for the masking based methods than for the subtraction based methods. Single energy based methods had a higher CNRD value than the corresponding dual energy based methods. For the subtraction based dual energy method, tin filtration improved the CNRD value with approximately 50%. For the masking based dual energy method, it was easier to differentiate between iodine and bone when tin filtration was applied. The CNRD value decreased only with 4% in that case. Compared to the dual scan based methods, the dual energy based methods had the advantage that only a single scan was made without the need of image registration. This might be easier to implement in clinical practice. Vessel preservation was better with bone subtraction than with bone masking. Smaller vessels were completely occluded by the bone mask. None of the bone removal methods was dose neutral. Conclusions: In general, dual scan based methods that use the lowest tube voltage available, have a higher CNR than the dual energy based approaches at the same dose level. Tin filtration improves the ability to differentiate between iodine and bone for the dual energy based masking method. In clinical practice, the advantages of the dual energy masking method might outweigh its disadvantage of a slightly higher dose penalty compared to the conventional dual scan masking method.
Transmission microscopy imaging systems include a mask and/or other modulator situated to encode image beams, e.g., by deflecting the image beam with respect to the mask and/or sensor. The beam is modulated/masked either before or after transmission through a sample to induce a spatially and/or temporally encoded signal by modifying any of the beam/image components including the phase/coherence, intensity, or position of the beam at the sensor. For example, a mask can be placed/translated through the beam so that several masked beams are received by a sensor during a single sensor integration time. Images associated with multiple mask displacements are then used to reconstruct a video sequence using a compressive sensing method. Another example of masked modulation involves a mechanism for phase-retrieval, whereby the beam is modulated by a set of different masks in the image plane and each masked image is recorded in the diffraction plane.
Transmission microscopy imaging systems include a mask and/or other modulator situated to encode image beams, e.g., by deflecting the image beam with respect to the mask and/or sensor. The beam is modulated/masked either before or after transmission through a sample to induce a spatially and/or temporally encoded signal by modifying any of the beam/image components including the phase/coherence, intensity, or position of the beam at the sensor. For example, a mask can be placed/translated through the beam so that several masked beams are received by a sensor during a single sensor integration time. Images associated with multiple mask displacements are then used to reconstruct a video sequence using a compressive sensing method. Another example of masked modulation involves a mechanism for phase-retrieval, whereby the beam is modulated by a set of different masks in the image plane and each masked image is recorded in the diffraction plane.
Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.