Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC MIRRORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Nonlinear mirror structures in a plasma with thermal pressure anisotropy

An asymptotic model based on a reductive perturbative expansion of the drift kinetic and the Maxwell equations, is used to demonstrate that, near the instability threshold, the nonlinear dynamics of mirror modes in a magnetized plasma with anisotropic ion temperatures, involves a subcritical bifurcation, leading to the formation of small-scale structures with amplitudes comparable with the ambient magnetic field. The influence of quasilinear effects on the initial stage of formation of mirror structures is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superconducting magnet performance for 28 GHz electron cyclotron resonance ion source developed at the Korea Basic Science Institute

A superconducting magnet for use in an electron cyclotron resonance ion source was developed at the Korea Basic Science Institute. The superconducting magnet is comprised of three solenoids and a hexapole magnet. According to the design value, the solenoid magnets can generate a mirror field, resulting in axial magnetic fields of 3.6 T at the injection area and 2.2 T at the extraction region. A radial field strength of 2.1 T can also be achieved by hexapole magnet on the plasma chamber wall. NbTi superconducting wire was used in the winding process following appropriate techniques for magnet structure. The final assembly of the each magnet involved it being vertically inserted into the cryostat to cool down the temperature using liquid helium. The performance of each solenoid and hexapole magnet was separately verified experimentally. The construction of the superconducting coil, the entire magnet assembly for performance testing and experimental results are reported herein.

43 PARTICLE ACCELERATORS↗

Simulation of magnetic holes formation in the magnetosheath

Magnetic holes have been frequently observed in the Earth's magnetosheath and are believed to be the consequence of the nonlinear evolution of the mirror instability. Mirror mode perturbations mainly form as magnetic holes in regions where the plasma is marginally mirror stable with respect to the linear instability criterion. We present an expanding box particle-in-cell simulation to mimic the changing conditions in the magnetosheath as the plasma is convected through it that produces mirror mode magnetic holes. We show that in the initial nonlinear evolution, where the plasma conditions are mirror unstable, the magnetic peaks are dominant, while later, as the plasma relaxes toward marginal stability, the fluctuations evolve into deep magnetic holes. Finally, while the averaged plasma parameters in the simulation remain close to the mirror instability threshold, the local plasma in the magnetic holes is highly unstable to mirror instability and locally mirror stable in the magnetic peaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Search for Axion Dark Matter with a MADMAX Prototype

This Letter presents the first search for dark matter axions with mass in the ranges 76.56 to 76.82 μ⁢eV and 79.31 to 79.53 μ⁢eV using a prototype setup for the MAgnetized Disk and Mirror Axion eXperiment (MADMAX). The experimental setup employs a dielectric haloscope consisting of three sapphire disks and a mirror to resonantly enhance the axion-induced microwave signal within the magnetic dipole field provided by the 1.6 T Morpurgo magnet at CERN. Over 14.5 days of data collection, no axion signal was detected. A 95% CL upper limit on the axion-photon coupling strength down to |𝑔 𝑎⁢𝛾 |∼2×10 −11 GeV −1 is set in the targeted mass ranges, surpassing previous constraints, assuming a local axion dark matter density 𝜌 𝑎 of 0.3 GeV/cm 3 . This study marks the first axion dark matter search using a dielectric haloscope.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of internal current rings in long closed magnetic confinement systems

A closed magnetic confinement system is considered in the shape a corrugated torus into one or several mirror cells of which current rings are introduced that reverse the magnetic field on the axis. An internal current ring surrounded by plasma creates a magnetic configuration with an average magnetic well on the axis. The axial plasma region of such a configuration is stabilized by cusps, whereas the outer region can be stabilized by a divertor, provided that the plasma pressure gradually decreases toward the periphery. The use of internal current rings may be profitable in stellarators in which the confinement region can be divided into several regions by magnetic mirrors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

/U,B,K/ coordinates - A natural system for studying magnetospheric convection

The formulation of the magnetospheric convection problem involves a coordinate system consisting of the electric potential, the magnetic field intensity, and the modified longitudinal invariant. The mapping is extended to include all particles and not just those mirroring in the magnetic equator. Equations of motion for the particle mirror points in this representation are presented. The analysis results in a natural division of the magnetosphere into accelerator and dynamo regions and use of the coordinate system permits trajectory-dependent effects to be distinguished from source- or sink-dependent effects. The representation is illustrated by application to the analysis of the nose structure protons observed by Smith and Hoffman (1974).

Whipple, E. C., Jr.↗

MHD-Stabilization of Axisymmetric Mirror Systems Using Pulsed ECRH

This paper, part of a continuing study of means for the stabilization of MHD interchange modes in axisymmertric mirror-based plasma confinement systems, is aimed at a preliminary look at a technique that would employ a train of plasma pressure pulses produced by ECRH to accomplish the stabilization. The purpose of using sequentially pulsed ECRH rather than continuous-wave ECRH is to facilitate the localization of the heated-electron plasma pulses in regions of the magnetic field with a strong positive field-line curvature, e. g. in the 'expander' region of the mirror magnetic field, outside the outermost mirror, or in other regions of the field with positive field-line curvature. The technique proposed, of the class known as 'dynamic stabilization,' relies on the time-averaged effect of plasma pressure pulses generated in regions of positive field-line curvature to overcome the destabilizing effect of plasma pressure in regions of negative field-line curvature within the confinement region. As will also be discussed in the paper, the plasma pulses, when produced in regions of the confining having a negative gradient, create transient electric potentials of ambipolar origin, an effect that was studied in 1964 in The PLEIDE experiment in France. These electric fields preserve the localization of the hot-electron plasma pulses for a time determined by ion inertia. It is suggested that it may be possible to use this result of pulsed ECRH not only to help to stabilize the plasma but also to help plug mirror losses in a manner similar to that employed in the Tandem Mirror.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wave-Driven Rotation In Centrifugal Mirrors

Centrifugal mirrors use supersonic rotation to provide axial confinement and enhanced stability. Usually the rotation is produced using electrodes, but these electrodes have limited the rotation to the Alfven critical ionization velocity, which is too slow to be useful for fusion. Instead, the rotation could be produced using radio frequency waves. A fixed azimuthal ripple is a simple and efficient wave that could produce rotation by harnessing alpha particle energy. This is an extension of the alpha channeling effect. The alpha particle power and efficiency in a simulated devices is sufficient to produce rotation without external energy input. By eliminating the need for electrodes, this opens new opportunities for centrifugal traps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ELECTRON TRAPPING IN WIGGLER AND QUADRUPOLE MAGNETS OF CESRTA

The Cornell Electron Storage Ring (CESR) has been reconfigured as an ultra low emittance damping ring for use as a test accelerator (CesrTA) for International Linear Collider (ILC) damping ring R&D [1]. One of the primary goals of the CesrTA program is to investigate the interaction of the electron cloud with low emittance positron beam to explore methods to suppress the electron cloud, develop suitable advanced instrumentation required for these experimental studies and benchmark predictions by simulation codes. This paper reports the simulation of the electron-cloud formation in the wiggler and quadrupole magnets using the 3D code CLOUDLAND. We found that electrons can be trapped with long lifetime in a quadrupole magnet due to the mirror field trapping mechanism and photoelectrons produced in the wiggler zero field zone have long lifetime due to their complicated trajectory.

43 PARTICLE ACCELERATORS↗

Gasdynamic Mirror Fusion Propulsion Experiment

A gasdynamic mirror (GDM) fusion propulsion experiment is currently being constructed at the NASA Marshall Space Flight Center (MSFC) to test the feasibility of this particular type of fusion device. Because of the open magnetic field line configuration of mirror fusion devices, they are particularly well suited for propulsion system applications since they allow for the easy ejection of thrust producing plasma. Currently, the MSFC GDM is constructed in three segments. The vacuum chamber mirror segment, the plasma injector mirror segment, and the main plasma chamber segment. Enough magnets are currently available to construct up to three main plasma chamber segments. The mirror segments are also segmented such that they can be expanded to accommodate new end plugging strategies with out requiring the disassembly of the entire mirror segment. The plasma for the experiment is generated in a microwave cavity located between the main magnets and the mirror magnets. Ion heating is accomplished through ambipolar diffusion. The objective of the experiment is to investigate the stability characteristics of the gasdynamic mirror and to map a region of parameter space within which the plasma can be confined in a stable steady state configuration. The mirror ratio, plasma density, and plasma "b" will be varied over a range of values and measurements subsequently taken to determine the degree of plasma stability.

Emrich, Bill↗

Feasibility Studies of Alpha-Channeling in Mirror Machines

The linear magnetic trap is an attractive concept both for fusion reactors and for other plasma applications due to its relative engineering simplicity and high-beta operation. Applying the α- channeling technique to linear traps, such as mirror machines, can benefit this concept by efficiently redirecting α particle energy to fuel ion heating or by otherwise sustaining plasma confinement, thus increasing the effective fusion reactivity. To identify waves suitable for α-channeling a rough optimization of the energy extraction rate with respect to the wave parameters is performed. After the optimal regime is identified, a systematic search for modes with similar parameters in mirror plasmas is performed, assuming quasi-longitudinal or quasi-transverse wave propagation. Several modes suitable for α particle energy extraction are identified for both reactor designs and for proof- of-principle experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ratio of isoscalar to isovector core polarization for magnetic moments

In calculations of isoscalar magnetic moments of odd-odd N=Z nuclei, it was found that, for medium- to heavy-mass nuclei, large-scale shell-model calculations yielded results that were very close to those obtained with the much simpler single-j shell model. To understand this, we compare isoscalar and isovector core-polarization configuration-mixing contributions to the magnetic moments of mirror pairs in first-order perturbation theory, using a spin-dependent {delta} interaction. We fit the strength of the {delta} interaction by looking at isovector and isoscalar mirror pairs. We then use the same interaction to calculate corrections due to first-order core polarization of the magnetic moments of odd-odd nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LIPSS Free-Electron Laser Searches for Dark Matter

A variety of Dark Matter particle candidates have been hypothesized by physics Beyond the Standard Model (BSM) in the very light (10{sup -6} - 10{sup -3} eV) range. In the past decade several international groups have conducted laboratory experiments designed to either produce such particles or extend the boundaries in parameter space. The LIght Pseudo-scalar and Scalar Search (LIPSS) Collaboration, using the 'Light Shining through a Wall' (LSW) technique, passes the high average power photon beam from Jefferson Lab's Free-Electron Laser through a magnetic field upstream from a mirror and optical beam dump. Light Neutral Bosons (LNBs), generated by coupling of photons with the magnetic field, pass through the mirror ('the Wall') into an identical magnetic field where they revert to detectable photons by the same coupling process. While no evidence of LNBs was evident, new scalar coupling boundaries were established. New constraints were also determined for hypothetical para-photons and for millicharged fermions. We will describe our experimental setup and results for LNBs, para-photons, and milli-charged fermions. Plans for chameleon particle searches are underway.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mirror Birefringence in a Fabry-Perot Cavity and the Detection of Vacuum Birefringence in a Magnetic Field

We discuss the effect of mirror birefringence in two optical schemes designed to detect the quantum-electrodynamics (QED) predictions of vacuum birefringence under the influence of a strong magnetic field, B. Both schemes make use of a high finesse Fabry-Perot cavity (F-P) to increase the average path length of the light in the magnetic field. The first scheme, which we called the frequency scheme, is based on measurement of the beat frequency of two orthogonal polarized laser beams in the cavity. We show that mirror birefringence contributes to the detection uncertainties in first order, resulting in a high susceptibility to small thermal disturbances. We estimate that an unreasonably high thermal stability of ~10-9 K is required to resolve the effect to 0.1%. In the second scheme, which we called the polarization rotation scheme, laser polarized at 45 relative to the B field is injected into the cavity.

Vacuum Birefringence↗

The hybrid reactor project based on the straight field line mirror concept

The straight field line mirror (SFLM) concept is aiming towards a steady-state compact fusion neutron source. Besides the possibility for steady state operation for a year or more, the geometry is chosen to avoid high loads on materials and plasma facing components. A comparatively small fusion hybrid device with 'semi-poor' plasma confinement (with a low fusion Q factor) may be developed for industrial transmutation and energy production from spent nuclear fuel. This opportunity arises from a large fission to fusion energy multiplication ratio, Q{sub r} = P{sub fis}/P{sub fus}>>1. The upper bound on Q{sub r} is primarily determined by geometry and reactor safety. For the SFLM, the upper bound is Q{sub r} Almost-Equal-To 150, corresponding to a neutron multiplicity of k{sub eff}=0.97. Power production in a mirror hybrid is predicted for a substantially lower electron temperature than the requirement T{sub e} Almost-Equal-To 10 keV for a fusion reactor. Power production in the SFLM seems possible with Q Almost-Equal-To 0.15, which is 10 times lower than typically anticipated for hybrids (and 100 times smaller than required for a fusion reactor). This relaxes plasma confinement demands, and broadens the range for use of plasmas with supra-thermal ions in hybrid reactors. The SFLM concept is based on a mirror machine stabilized by qudrupolar magnetic fields and large expander tanks beyond the confinement region. The purpose of the expander tanks is to distribute axial plasma loss flow over a sufficiently large area so that the receiving plates can withstand the heat. Plasma stability is not relying on a plasma flow into the expander regions. With a suppressed plasma flow into the expander tanks, a possibility arise for higher electron temperature. A brief presentation will be given on basic theory for the SFLM with plasma stability and electron temperature issues, RF heating computations with sloshing ion formation, neutron transport computations with reactor safety margins and material load estimates, magnetic coil designs as well as a discussion on the implications of the geometry for possible diagnostics. Reactor safety issues are addressed and a vertical orientation of the device could assist passive coolant circulation. Specific attention is put to a device with a 25 m long confinement region and 40 cm plasma radius in the mid-plane. In an optimal case (k{sub eff}= 0.97) with a fusion power of only 10 MW, such a device may be capable of producing a power of 1.5 GW{sub th}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pulse compressor with aberration correction

In this SBIR project, Electron Optica, Inc. (EOI) is developing an electron mirror-based pulse compressor attachment to new and retrofitted dynamic transmission electron microscopes (DTEMs) and ultrafast electron diffraction (UED) cameras for improving the temporal resolution of these instruments from the characteristic range of a few picoseconds to a few nanoseconds and beyond, into the sub-100 femtosecond range. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. EOI’s pulse compressor technology utilizes the combination of electron mirror optics and a magnetic beam separator to compress the electron pulse. The design exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the temporally broadened beam. This system also simultaneously corrects the chromatic and spherical aberration of the objective lens for improved spatial resolution. This correction will be found valuable as the source size is reduced with laser-triggered point source emitters. With such emitters, it might be possible to significantly reduce the illuminated area and carry out ultrafast diffraction experiments from small regions of the sample, e.g. from individual grains or nanoparticles. During phase I, EOI drafted a set of candidate pulse compressor architectures and evaluated the trade-offs between temporal resolution and electron bunch size to achieve the optimum design for two particular applications with market potential: increasing the temporal and spatial resolution of UEDs, and increasing the temporal and spatial resolution of DTEMs. Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key pulse compressor components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded into a model describing the key electron-optical parameters of the complete pulse compressor. The simulations reveal that the mirror pulse compressor can reduce the temporal spread of UEDs and DTEMs to the sub-100 femtosecond level for practical electron bunch sizes. EOI’s pulse compressors can be designed and built to attach to different types of UEDs and DTEMs, thus making them suitable for enhancing the study of the structure, composition, and bonding states of new materials at ultrafast time scales to advance material science research in the field of nanotechnology as well as biomedical research.

47 OTHER INSTRUMENTATION↗

Determination of magnetic helicity in the solar wind and implications for cosmic ray propagation

The mean value of the correlation between local magnetic field and vector potential, known as the magnetic helicity, is a measure of the lack of mirror reflection symmetry of magnetic covariances in a turbulent medium. A method is presented for extraction of helicity spectra from magnetometer data, and applied to an evaluation of the magnetic helicity of interplanetary magnetic fluctuations.

Matthaeus, W. H.↗