At least 397 records · Page 22

Turbulence measurements using the laser Doppler velocimeter

The photomultiplier signal representing the axial velocity of water within a glass pipe is examined. It is shown that with proper analysis of the photomultiplier signal, the turbulent information that can be obtained in liquid flows is equivalent to recent hot film studies. In shear flows the signal from the laser Doppler velocimeter contains additional information which may be related to the average shear.

Dunning, J. W., Jr.↗

Magnetohydrodynamic generator experimental studies

The results for an experimental study of a one wavelength MHD induction generator operating on a liquid flow are presented. First the design philosophy and the experimental generator design are summarized, including a description of the flow loop and instrumentation. Next a Fourier series method of treating the fact that the magnetic flux density produced by the stator is not a pure traveling sinusoid is described and some results summarized. This approach appears to be of interest after revisions are made, but the initial results are not accurate. Finally, some of the experimental data is summarized for various methods of excitation.

Pierson, E. S.↗

Turbulence measurements using the laser Doppler velocimeter.

The photomultiplier signal representing the axial velocity of water within a glass pipe is considered. It is shown that with proper analysis of the photomultiplier signal, the turbulent information that can be obtained in liquid flows is equivalent to results obtained in recent hot film studies. In shear flows the signal from the laser Doppler velocimeter contains additional information which may be related to the average shear.

Dunning, J. W., Jr.↗

Heat pipe stability. 1: A preliminary investigation into thermally assisted cavitation

The notion is introduced of thermally assisted cavitation by localized fluctuations in capillary forces. Because cavitation in liquids can be closely approximated by an isothermal process, only momentum and mass balances are used to introduce the notion for liquids under mechanical tension. Brief attention is given to developing a stability theory in terms of the stiffness and compliance coefficients for a working fluid. Interestingly, the particular thermodynamic approach taken can be used to suggest experiments relating working fluid performance to meniscus behavior. A correction to the liquid flow equation is suggested.

Source record↗

Study of the collector/heat pipe cooled externally configured thermionic diode

A collector/heat pipe cooled, externally configured (heated) thermionic diode module was designed for use in a laboratory test to demonstrate the applicability of this concept as the fuel element/converter module of an in-core thermionic electric power source. During the course of the program, this module evolved from a simple experimental mock-up into an advanced unit which was more reactor prototypical. Detailed analysis of all diode components led to their engineering design, fabrication, and assembly, with the exception of the collector/heat pipe. While several designs of high power annular wicked heat pipes were fabricated and tested, each exhibited unexpected performance difficulties. It was concluded that the basic cause of these problems was the formation of crud which interfered with the liquid flow in the annular passage of the evaporator region.

Source record↗

Space simulation experiments on reaction control system thruster plumes.

A space simulation procedure was developed for studying rocket plume contamination effects using a 5-lb bipropellant reaction control system thrustor. Vacuum chamber pressures of 0.00003 torr (70 miles altitude) were achieved with the thrustor firing in pulse trains consisting of eight pulses - 50 msec on, 100 msec off, and seven minutes between pulse trains. The final vacuum was achieved by cooling all vacuum chamber surfaces to liquid-helium temperature and by introducing a continuous argon leak of 48 std. cc/sec into the test chamber. Fast time response liquid flow rate measurements showed that large variations occurred in the ratio of oxidizer to fuel flow for pulse-on times up to 120 msec. These variations could lead to poor combustion efficiency and the production of contamination.

Cassidy, J. F.↗

Flat plate electrohydrodynamic heat pipe experiments

Performance capabilities of electrohydrodynamic (EHD) flat heat pipes were investigated using Freon 113 and Freon 11 as working fluids. All of the pipes employed straight rod electrodes to form axial liquid flow channels and tranverse grooves for capillary surface wetting. Results show: (1) the EHD pipe will prime under load, (2) voltage controlled conductance can be achieved by varying the active area of the evaporator, and (3) the average evaporator conductances measured in these experiments were consistent with those obtained in other experiments with heat pipes of similar surface geometry using the same or similar working fluids.

Loehrke, R. I.↗

Performance characteristics of the U.VA. superconducting wind tunnel balance

Initial operational characteristics of a wind tunnel electromagnetic balance utilizing superconducting coils are reported. Both dc and ac superconducting coils are used for balancing and measuring 3-component aerodynamic forces on simple models in Mach 3, room temperature flow. Liquid helium boil-off measurements corresponding to a wide range of operating conditions are presented together with results of systematic ac losses scaling experiments using various pancake coils wound with superconducting tape. This unique prototype facility is primarily for studying the practical feasibility of using superconducting magnetic suspension techniques for aerodynamic testing and accumulating the knowledge and expertise required for extrapolating these techniques to large-scale facilities.

Humphris, R. R.↗

Nonintrusive Flowmeter

The results of analytical and experimental work performed in the design, fabrication, and test of a prototype nonintrusive gaging system for use in monitoring the consumption of earth-storable fuels and oxidants in either a one-g or a zero-g environment are explained. The design specifications were those applicable to the reaction control system and to the orbital maneuvering system (OMS) fuel and oxidant on the space shuttle while in orbit. The major requirement was for the measurement of flow pulses with sufficient accuracy to provide a continuous knowledge of the fuel and oxidant remaining in the OMS system to within 1% or better. An ultrasonic frequency chirp technique was used having a high inherent rejection for signals traversing stray paths, and for random noise generated by the flowing liquid. A detailed analysis of the frequency chirp approach for two modes of operation (period and phase changes), including an error analysis are reported.

Greene, M. W.↗

Biological sampling and cleaning device

Flowing-liquid cleaner may be used to gently dislodge and remove 98 percent of biological particulates from surfaces. Cleaner may retain up to 90 percent of removed particulates for later analysis. If retention is not required, unit may be adapted to clean only. Cleaner is applicable wherever very clean surface is desired.

Scheider, H. W.↗

Weathering of a flat-plate solar collector

Report contains performance evaluation of flat-plate liquid solar collector after 14-months of natural weathering. Collector efficiency was calculated and plotted as function of inlet liquid temperature. Measurements were made of ambient temperature, inlet and outlet temperatures, differential temperature and pressure, liquid flow rate, insolation, and windspeed.

Source record↗

Evaluation of instability forces of labyrinth seals in turbines or compressors

The effects of a force induced by the labyrinth seal on the stability of rotor systems and the factors of the seal which affect the stability are investigated. In the analysis, it is assumed that the fluid in the seal is steady and that the rotor is set vertically in order to avoid the effects of gravity force. The force induced by the seal is expressed in terms proportional to the velocity and displacement of the rotor and is deduced to that expression for the oil film force in journal bearings. That force is taken into account in the equations of motion; then the stability of the system is discussed by energy concept. The force induced by the labyrinth seal always makes the rotor system unstable, and the tendency is marked when seal leakages are small. The resonance point of the rotor system is also affected by the labyrinth seal (the resonance point of the rotor system is removed by the seal leakages). The force induced by the labyrinth seal was measured by using a water-tunnel experimental system which was designed to measure the labyrinth seal force by using the similarity between gas and liquid flow theory.

Iwatsubo, T.↗

Metering Baffle for Turbine-Blade Cooling

Mixing losses due to excessive film cooling reduced. Turbine blade or vane cooled by gas or liquid flowing through holes to exterior airfoil surface. Metering baffle inside airfoil controls flow to each row of cooling holes. Resulting surface-film flow keeps airfoil cool enough to operate in high-heat, high pressure turbines.

Moore, R.↗

Study of a heat rejection system for the Nuclear Electric Propulsion (NEP) spacecraft

Two different heat pipe radiator elements, one intended for use with the power conversion subsystem of the NASA funded nuclear electric propulsion (NEP) spacecraft, and one intended for use with the DOE funded space power advanced reactor (SPAR) system were tested and evaluated. The NEP stainless steel/sodium heat pipe was 4.42 meters long and had a 1 cm diameter. Thermal performance testing at 920 K showed a non-limited power level of 3560 watts, well in excess of the design power of 2600 watts. This test verified the applicability of screen arteries for use in long radiator heat pipes. The SPAR titanium/potassium heat pipe was 5.5 meters long and had a semicircular crossection with a 4 cm diameter. Thermal performance testing at 775 K showed a maximum power level of 1.86 kW, somewhat short of the desired 2.6 kW beginning of life design requirement. The reduced performance was shown to be the result of the inability of the evaporator wall wick (shot blasted evaporator wall) to handle the required liquid flow.

Ernest, D. M.↗

Aquatic Plants Aid Sewage Filter

Method of wastewater treatment combines micro-organisms and aquatic plant roots in filter bed. Treatment occurs as liquid flows up through system. Micro-organisms, attached themselves to rocky base material of filter, act in several steps to decompose organic matter in wastewater. Vascular aquatic plants (typically, reeds, rushes, cattails, or water hyacinths) absorb nitrogen, phosphorus, other nutrients, and heavy metals from water through finely divided roots.

Wolverton, B. C.↗

Preventing Fires in Cryogenic Oxidizer Lines

Friction and compression induced ignition prevented by heat-dissipation layer. Thin layer of copper placed inside surfaces of pipes and other parts in contact with flowing liquid oxygen, fluorine, or other oxidizers. Copper layer of only 0.001 to 0.005 inch (0.0254 to 0.127 mm) ensures heat away from hotspots thereby discouraging ignition. Copper layer increases oxygen ignition threshold of pipe by 5 to 20 times.

Wagner, W. R.↗

Platinum-Resistor Differential Temperature Sensor

Platinum resistance elements used in bridge circuit for measuring temperature difference between two flowing liquids. Temperature errors with circuit are less than 0.01 degrees C over range of 100 degrees C.

Kolbly, R. B.↗

A pumped two-phase cooling system for spacecraft

A pumped, two-phase heat-transport system is being developed for possible use for temperature control of scientific instruments on future NASA missions. As compared to a single-phase system, this two-phase system can maintain tighter temperature control with less pumping power. A laboratory model of the system has been built and tested. The measured heat transfer coefficients were approximately the same as in heat pipes, 220 Btu/hr-sq ft-F, as compared to 25 Btu/hr-sq ft-F for single-phase liquid flow. Heat shearing between experiments has been demonstrated wherein vapor generated in the cold plate of an active experiment was condensed in a cold, unheated experiment. System stability has been observed. However, additional development is needed. The use of non-azeotropic mixtures of coolants appears especially promising as a simple way to determine exit quality and thus control the flow rates to prevent dryout.

Ollendorf, S.↗