Remote Sensing System-Level Modeling & Simulation Capability; Remote Sensing System-Level Analysis Test and V&V Capability.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
During the decommissioning and maintenance of some of the facilities at the U.S. Department of Energy Hanford Site in Washington State, workers have potential for a 90Sr intake. However, because of worldwide radioactive fallout, 90Sr is present in our environment, and can be detectable in routine urine bioassay samples. It is important for the Hanford Site bioassay program to discern an occupational intake from a non-occupational environmental one. A detailed study of the background 90Sr in the urine of unexposed Hanford workers was performed. A survey of the Hanford Site bioassay database found 128 Hanford workers who were hired between 1997 and 2002 and who had a very low potential for an occupational exposure prior to the baseline strontium urinalysis. Each urinalysis sample represented excretion during an approximate 24-hr period. The arithmetic mean value for the 128 pre-exposure baselines was 3.6 ± 5.1 mBq d-1. The 90Sr activities in urine varied from -12 to 20 mBq. The 99th percentile result was 16.4 mBqd-1, which was interpreted to mean that 1% of Hanford workers not occupationally exposed to strontium might exceed 16.4 mBq d-1.
In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)
Testing at the subsystem or black box level for lightning hardness is required if system hardness is to be assured at the system level. The often applied philosophy of lighting testing only at the system level leads to extensive end of the line design changes which result in excessive costs and time delays. In order to perform testing at the subsystem level two important factors must be defined to make the testing simulation meaningful. The first factor is the definition of the test stimulus appropriate to the subsystem level. Application of system level stimulations to the subsystem level usually leads to significant overdesign of the subsystem which is not necessary and may impair normal subsystem performance. The second factor is the availability of test equipment needed to provide the subsystem level lightning stimulation. Equipment for testing at this level should be portable or at least movable to enable efficient testing in a design laboratory environment. Large fixed test installations for system level tests are not readily available for use by the design engineers at the subsystem level and usually require special operating skills. The two factors, stimulation level and test equipment availability, must be evaluated together in order to produce a practical, workable test standard. The neglect or subordination of either factor will guarantee failure in generating the standard. It is not unusual to hear that test standards or specifications are waived because a specified stimulation level cannot be accomplished by in-house or independent test facilities. Determination of subsystem lightning simulation level requires a knowledge and evaluation of field coupling modes, peak and median levels of voltages and currents, bandwidths, and repetition rates. Practical limitations on test systems may require tradeoffs in lightning stimulation parameters in order to build practical test equipment. Peak power levels that can be generated at specified bandwidths with standard electrical components must be considered in the design and costing of the test system. Stimulation tests equipment and test methods are closely related and must be considered a test system for lightning simulation. A non-perfect specification that can be reliably and repeatedly applied at the subsystem test level is more desirable than a perfect specification that cannot be applied at all.
Blood uric acid has been recognized as a putative marker for cardiovascular diseases (CVDs). CVDs are the major causes of arsenic-related morbidity and mortality. However, the association of arsenic exposure with plasma uric acid (PUA) levels in relation to CVDs has not yet been explored. This study for the first time demonstrated the associations of arsenic exposure with PUA levels and its relationship with hypertension. A total of 483 subjects, 322 from arsenic-endemic and 161 from non-endemic areas in Bangladesh were recruited as study subjects. Arsenic concentrations in the drinking water, hair and nails of the study subjects were measured by inductively coupled plasma mass spectroscopy. PUA levels were measured using a colorimetric method. We found that PUA levels were significantly (p < 0.001) higher in males and females living in arsenic-endemic areas than those in non-endemic area. Arsenic exposure (water, hair and nail arsenic) levels showed significant positive correlations with PUA levels. In multiple regression analyses, arsenic exposure levels were found to be the most significant contributors on PUA levels among the other variables that included age, body mass index, blood urea nitrogen, and smoking. There were dose–response relationships between arsenic exposure and PUA levels. Furthermore, diastolic and systolic blood pressure showed significant positive correlations with PUA levels. Finally, the average PUA levels were significantly higher in the hypertensive group than those in the normotensive group in both males and females living in arsenic-endemic areas. These results suggest that arsenic exposure-related elevation of PUA levels may be implicated in arsenic-induced CVDs. - Highlights: • PUA levels were higher in arsenic-endemic subjects than in non-endemic subjects. • Drinking water, hair and nail arsenic showed significant associations with PUA levels. • Drinking water, hair and nail arsenic showed dose–response relationships with PUA. • Arsenic-endemic hypertensive study subjects had elevated levels of PUA. • Increased PUA levels may be implicated in arsenic-induced CVDs.
The International Space Station's (ISS) trajectory is coordinated and executed by the Trajectory Operations and Planning (TOPO) group at NASA's Johnson Space Center. TOPO group personnel routinely generate look-ahead trajectories for the ISS that incorporate translation burns needed to maintain its orbit over the next three to twelve months. The burns are modeled as in-plane, horizontal burns, and must meet operational trajectory constraints imposed by both NASA and the Russian Space Agency. In generating these trajectories, TOPO personnel must determine the number of burns to model, each burn's Time of Ignition (TIG), and magnitude (i.e. deltaV) that meet these constraints. The current process for targeting these burns is manually intensive, and does not take advantage of more modern techniques that can reduce the workload needed to find feasible burn solutions, i.e. solutions that simply meet the constraints, or provide optimal burn solutions that minimize the total DeltaV while simultaneously meeting the constraints. A two-level, hybrid optimization technique is proposed to find both feasible and globally optimal burn solutions for ISS trajectory planning. For optimal solutions, the technique breaks the optimization problem into two distinct sub-problems, one for choosing the optimal number of burns and each burn's optimal TIG, and the other for computing the minimum total deltaV burn solution that satisfies the trajectory constraints. Each of the two aforementioned levels uses a different optimization algorithm to solve one of the sub-problems, giving rise to a hybrid technique. Level 2, or the outer level, uses a genetic algorithm to select the number of burns and each burn's TIG. Level 1, or the inner level, uses the burn TIGs from Level 2 in a sequential quadratic programming (SQP) algorithm to compute a minimum total deltaV burn solution subject to the trajectory constraints. The total deltaV from Level 1 is then used as a fitness function by the genetic algorithm in Level 2 to select the number of burns and their TIGs for the next generation. In this manner, the two levels solve their respective sub-problems separately but collaboratively until a burn solution is found that globally minimizes the deltaV across the entire trajectory. Feasible solutions can also be found by simply using the SQP algorithm in Level 1 with a zero cost function. This paper discusses the formulation of the Level 1 sub-problem and the development of a prototype software tool to solve it. The Level 2 sub-problem will be discussed in a future work. Following the Level 1 formulation and solution, several look-ahead trajectory examples for the ISS are explored. In each case, the burn targeting results using the current process are compared against a feasible solution found using Level 1 in the proposed technique. Level 1 is then used to find a minimum deltaV solution given the fixed number of burns and burn TIGs. The optimal solution is compared with the previously found feasible solution to determine the deltaV (and therefore propellant) savings. The proposed technique seeks to both improve the current process for targeting ISS burns, and to add the capability to optimize ISS burns in a novel fashion. The optimal solutions found using this technique can potentially save hundreds of kilograms of propellant over the course of the ISS mission compared to feasible solutions alone. While the software tool being developed to implement this technique is specific to ISS, the concept is extensible to other long-duration, central-body orbiting missions that must perform orbit maintenance burns to meet operational trajectory constraints.
Susceptibility to environmental stressors has been described for fetal and early childhood development. However, the possible susceptibility of the prepubertal period, characterized by the orchestration of the organism towards sexual maturation and adulthood has been poorly investigated and exposure data are scarce. In the current study levels of cadmium (Cd), cotinine and creatinine in urine were analyzed in a subsample 216 children from 12 European countries within the DEMOCOPHES project. The children were divided into six age–sex groups: boys (6–8 years, 9–10 years and 11 years old), and girls (6–7 years, 8–9 years, 10–11 years). The number of subjects per group was between 23 and 53. The cut off values were set at 0.1 µg/L for Cd, and 0.8 µg/L for cotinine defined according to the highest limit of quantification. The levels of Cd and cotinine were adjusted for creatinine level. In the total subsample group, the median level of Cd was 0.180 µg/L (range 0.10–0.69 µg/L), and for cotinine the median wet weight value was 1.50 µg/L (range 0.80–39.91 µg/L). There was no significant difference in creatinine and cotinine levels between genders and age groups. There was a significant correlation between levels of cadmium and creatinine in all children of both genders. This shows that even at such low levels the possible effect of cadmium on kidney function was present and measurable. An increase in Cd levels was evident with age. Cadmium levels were significantly different between 6–7 year old girls, 11 year old boys and 10–11 year old girls. As there was a balanced distribution in the number of subjects from countries included in the study, bias due to data clustering was not probable. The impact of low Cd levels on kidney function and gender differences in Cd levels needs further investigation. - Highlights: • In 216 children from 6 to 11 years old the median level of Cd was 0.18 µg/L. • The median level of cotinine was 1.50 µg/L. • Correlation between levels of Cd and creatinine in all children was detected. • Cd levels were different between 6–7 year old, 10–11 year old girls vs. 11 year old boys.
Water-level modeling is used for multiple-well aquifer tests to reliably differentiate pumping responses from natural water-level changes in wells, or environmental fluctuations. Synthetic water levels are created during water-level modeling and represent the summation of multiple component fluctuations, including those caused by environmental forcing and pumping. Pumping signals are modeled by transforming step-wise pumping records into water-level changes by using superimposed Theis functions. Water-levels can be modeled robustly with this Theis-transform approach because environmental fluctuations and pumping signals are simulated simultaneously. Water-level modeling with Theis transforms has been implemented in the program SeriesSEE, which is a Microsoft® Excel add-in. Moving average, Theis, pneumatic-lag, and gamma functions transform time series of measured values into water-level model components in SeriesSEE. Earth tides and step transforms are additional computed water-level model components. Water-level models are calibrated by minimizing a sum-of-squares objective function where singular value decomposition and Tikhonov regularization stabilize results. Drawdown estimates from a water-level model are the summation of all Theis transforms minus residual differences between synthetic and measured water levels. The accuracy of drawdown estimates is limited primarily by noise in the data sets, not the Theis-transform approach. Drawdowns much smaller than environmental fluctuations have been detected across major fault structures, at distances of more than 1 mile from the pumping well, and with limited pre-pumping and recovery data at sites across the United States. In addition to water-level modeling, utilities exist in SeriesSEE for viewing, cleaning, manipulating, and analyzing time-series data.
The inaccuracies of liquid nitrogen and liquid hydrogen level measurements by use of a coaxial capacitance probe were investigated as a function of fluid temperatures and pressures. Significant liquid level measurement errors were found to occur due to the changes in the fluids dielectric constants which develop over the operating temperature and pressure ranges of the cryogenic storage tanks. The level measurement inaccuracies can be reduced by using fluid dielectric correction factors based on measured fluid temperatures and pressures. The errors in the corrected liquid level measurements were estimated based on the reported calibration errors of the temperature and pressure measurement systems. Experimental liquid nitrogen (LN2) and liquid hydrogen (LH2) level measurements were obtained using the calibrated capacitance probe equations and also by the dielectric constant correction factor method. The liquid levels obtained by the capacitance probe for the two methods were compared with the liquid level estimated from the fluid temperature profiles. Results show that the dielectric constant corrected liquid levels agreed within 0.5 percent of the temperature profile estimated liquid level. The uncorrected dielectric constant capacitance liquid level measurements deviated from the temperature profile level by more than 5 percent. This paper identifies the magnitude of liquid level measurement error that can occur for LN2 and LH2 fluids due to temperature and pressure effects on the dielectric constants over the tank storage conditions from 5 to 40 psia. A method of reducing the level measurement errors by using dielectric constant correction factors based on fluid temperature and pressure measurements is derived. The improved accuracy by use of the correction factors is experimentally verified by comparing liquid levels derived from fluid temperature profiles.
Background: Data on selenium (Se) levels in American young adults, especially in African Americans, are lacking. Objective: This study presented toenail Se distributions in American young adults of both genders, including both Caucasians and African Americans; and explored potential predictors of toenail Se levels. Data and methods: Data from the Coronary Artery Risk Development in Young Adults study among 4252 American young adults, aged 20-32 in 1987 was used to examine toenail Se levels by instrumental neutron-activation analysis. The distribution of Se levels was described and multivariable linear regression was used to examine potential modifiers of toenail Se concentration within ethnicity-gender subgroups. Results: The geometric mean of toenail Se in this cohort was 0.844 {mu}g/g (95% CI, 0.840-0.849 {mu}g/g) and the median was 0.837 {mu}g/g (95% CI, 0.833-0.844 {mu}g/g). Median levels from lowest to highest quintile were 0.691, 0.774, 0.838, 0.913 and 1.037 {mu}g/g. Se levels varied geographically, and were generally in accordance with its concentrations in local soil. Males, African Americans, current smokers, heavy drinkers and less educated participants were more likely to have low Se levels. Conclusion: This study suggests that toenail Se levels vary geographically depending on soil Se concentrations. In addition to gender, ethnicity and education level, smoking status and alcohol consumption are two important indicators of Se status since they are modifiable lifestyle factors. Findings from this study might aid public health professionals in identifying people at relatively high or low Se levels, so that chronic disease prevention efforts can be directed toward these subgroups. - Research highlights: {yields} Average of toenail Se levels in this cohort was 0.844 {mu}g/g (95% CI, 0.840-0.849 {mu}g/g). {yields} Toenail Se levels vary geographically depending on soil Se concentrations. {yields} Males, African Americans and less educated participants have low Se levels. {yields} Smoking status and alcohol consumption are two important indicators of Se status.
There is an abundance of data for levels of metals from a range of species, but relatively few long-term time series from the same location. In this paper I examine the levels of arsenic, cadmium, chromium, lead, manganese, mercury and selenium in feathers from fledgling great egrets (Ardea alba) collected at nesting colonies in Barnegat Bay, New Jersey from 1989 to 2011. The primary objectives were to test the null hypotheses that (1) There were no temporal differences in metal levels in feathers of fledgling great egrets, and (2) Great egrets nesting in different areas of Barnegat Bay (New Jersey) did not differ in metal levels. There were significant yearly variations in levels of all heavy metals in feathers of fledgling great egret, but levels decreased significantly from 1989 to 2011 only for lead (1470 ppb to 54.3 ppb), cadmium (277 ppb to 30.5 ppb), and manganese (only since 1996; 2669 ppb to 329 ppb)). Although mercury levels decreased from 2003–2008 (6430 ppb to 1042 ppb), there was no pattern before 2003, and levels increased after 2008 to 2610 ppb in 2011. Lead, cadmium, chromium, manganese and mercury were higher in feathers from great egrets nesting in the northern part of the bay, and selenium was highest in feathers from mid-bay. The lack of a temporal decline in mercury levels in feathers of great egrets is cause for concern, since the high levels in feathers from some years (means as high as 6430 ppb) are in the range associated with adverse effects (5000 ppb for feathers). -- Highlights: ► Metals were monitored in feathers of great egrets from Barnegat Bay, New Jersey. ► Levels of cadmium and lead decreased significantly from 1989–2011. ► Mercury levels in feathers from great egrets did not decline from 1989–2011. ► Metal levels were generally higher in great egrets and black-crowned night heron feathers than in snowy egrets.
Purpose: Previously, we showed that ectopic miR-101 could sensitize human tumor cells to radiation by targeting ATM and DNA-PK catalytic subunit (DNA-PKcs) to inhibit DNA repair, as the endogenous miR-101 levels are low in tumors in general. However, the heterogeneity of human cancers may result in an exception. The purpose of this study was to test the hypothesis that a few tumor cell lines with a high level of endogenous miR-101 would prove less response to ectopic miR-101. Methods and Materials: Fourteeen non-small-cell lung cancer (NSCLC) cell lines and one immortalized non-malignant lung epithelial cell line (NL20) were used for comparing endogenous miR-101 levels by real-time reverse transcription-polymerase chain reaction. Based on the different miR-101 levels, four cell lines with different miR-101 levels were chosen for transfection with a green fluorescent protein-lentiviral plasmid encoding miR-101. The target protein levels were measured by using Western blotting. The radiosensitizing effects of ectopic miR-101 on these NSCLC cell lines were determined by a clonogenic assay and xenograft mouse model. Results: The endogenous miR-101 level was similar or lower in 13 NSCLC cell lines but was 11-fold higher in one cell line (H157) than in NL20 cells. Although ectopic miR-101 efficiently decreased the ATM and DNA-PKcs levels and increased the radiosensitization level in H1299, H1975, and A549 cells, it did not change the levels of the miR-101 targets or radiosensitivity in H157 cells. Similar results were observed in xenograft mice. Conclusions: A small number of NSCLC cell lines could have a high level of endogenous miR-101. The ectopic miR-101 was able to radiosensitize most NSCLC cells, except for the NSCLC cell lines that had a much higher endogenous miR-101 level. These results suggest that when we choose one miRNA as a therapeutic tool, the endogenous level of the miRNA in each tumor should be considered.
Chronic arsenic (As) exposure affects the endothelial system causing several diseases. Big endothelin-1 (Big ET-1), the biological precursor of endothelin-1 (ET-1) is a more accurate indicator of the degree of activation of the endothelial system. Effect of As exposure on the plasma Big ET-1 levels and its physiological implications have not yet been documented. We evaluated plasma Big ET-1 levels and their relation to hypertension and skin lesions in As exposed individuals in Bangladesh. A total of 304 study subjects from the As-endemic and non-endemic areas in Bangladesh were recruited for this study. As concentrations in water, hair and nails were measured by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). The plasma Big ET-1 levels were measured using a one-step sandwich enzyme immunoassay kit. Significant increase in Big ET-1 levels were observed with the increasing concentrations of As in drinking water, hair and nails. Further, before and after adjusting with different covariates, plasma Big ET-1 levels were found to be significantly associated with the water, hair and nail As concentrations of the study subjects. Big ET-1 levels were also higher in the higher exposure groups compared to the lowest (reference) group. Interestingly, we observed that Big ET-1 levels were significantly higher in the hypertensive and skin lesion groups compared to the normotensive and without skin lesion counterpart, respectively of the study subjects in As-endemic areas. Thus, this study demonstrated a novel dose–response relationship between As exposure and plasma Big ET-1 levels indicating the possible involvement of plasma Big ET-1 levels in As-induced hypertension and skin lesions. -- Highlights: ► Plasma Big ET-1 is an indicator of endothelial damage. ► Plasma Big ET-1 level increases dose-dependently in arsenic exposed individuals. ► Study subjects in arsenic-endemic areas with hypertension have elevated Big ET-1 levels. ► Study subjects with arsenic-induced skin lesions show elevated plasma Big ET-1 levels. ► Arsenic-induced hypertension and skin lesions may be linked to plasma Big ET-1 levels.
Introduction: HJURP (Holliday Junction Recognition Protein) is a newly discovered gene reported to function at centromeres and to interact with CENPA. However its role in tumor development remains largely unknown. The goal of this study was to investigate the clinical significance of HJURP in breast cancer and its correlation with radiotherapeutic outcome. Methods: We measured HJURP expression level in human breast cancer cell lines and primary breast cancers by Western blot and/or by Affymetrix Microarray; and determined its associations with clinical variables using standard statistical methods. Validation was performed with the use of published microarray data. We assessed cell growth and apoptosis of breast cancer cells after radiation using high-content image analysis. Results: HJURP was expressed at higher level in breast cancer than in normal breast tissue. HJURP mRNA levels were significantly associated with estrogen receptor (ER), progesterone receptor (PR), Scarff-Bloom-Richardson (SBR) grade, age and Ki67 proliferation indices, but not with pathologic stage, ERBB2, tumor size, or lymph node status. Higher HJURP mRNA levels significantly decreased disease-free and overall survival. HJURP mRNA levels predicted the prognosis better than Ki67 proliferation indices. In a multivariate Cox proportional-hazard regression, including clinical variables as covariates, HJURP mRNA levels remained an independent prognostic factor for disease-free and overall survival. In addition HJURP mRNA levels were an independent prognostic factor over molecular subtypes (normal like, luminal, Erbb2 and basal). Poor clinical outcomes among patients with high HJURP expression werevalidated in five additional breast cancer cohorts. Furthermore, the patients with high HJURP levels were much more sensitive to radiotherapy. In vitro studies in breast cancer cell lines showed that cells with high HJURP levels were more sensitive to radiation treatment and had a higher rate of apoptosis than those with low levels. Knock down of HJURP in human breast cancer cells using shRNA reduced the sensitivity to radiation treatment. HJURP mRNA levels were significantly correlated with CENPA mRNA levels. Conclusions: HJURP mRNA level is a prognostic factor for disease-free and overall survival in patients with breast cancer and is a predictive biomarker for sensitivity to radiotherapy.
This paper describes the results of a sea level measurement test conducted off La Jolla, California, in November of 1991. The purpose of this test was to determine accurate sea level measurements using a Global Positioning System (GPS) equipped buoy. These measurements were intended to be used as the sea level component for calibration of the ERS 1 satellite altimeter. Measurements were collected on November 25 and 28 when the ERS 1 satellite overflew the calibration area. Two different types of buoys were used. A waverider design was used on November 25 and a spar design on November 28. This provided the opportunity to examine how dynamic effects of the measurement platform might affect the sea level accuracy. The two buoys were deployed at locations approximately 1.2 km apart and about 15 km west of a reference GPS receiver located on the rooftop of the Institute of Geophysics and Planetary Physics at the Scripps Institute of Oceanography. GPS solutions were computed for 45 minutes on each day and used to produce two sea level time series. An estimate of the mean sea level at both locations was computed by subtracting tide gage data collected at the Scripps Pier from the GPS-determined sea level measurements and then filtering out the high-frequency components due to waves and buoy dynamics. In both cases the GPS estimate differed from Rapp's mean altimetric surface by 0.06 m. Thus, the gradient in the GPS measurements matched the gradient in Rapp's surface. These results suggest that accurate sea level can be determined using GPS on widely differing platforms as long as care is taken to determine the height of the GPS antenna phase center above water level. Application areas include measurement of absolute sea level, of temporal variations in sea level, and of sea level gradients (dominantly the geoid). Specific applications would include ocean altimeter calibration, monitoring of sea level in remote regions, and regional experiments requiring spatial and temporal resolution higher than that available from altimeter data.
In fulfillment of requirements of the Maryland Commission on Climate Change Act of 2015, this report provides updated projections of the amount of sea-level rise relative to Maryland coastal lands that is expected into the next century. These projections represent the consensus of an Expert Group drawn from the Mid-Atlantic region. The framework for these projections is explicitly tied to the projections of global sea-level rise included in the Intergovernmental Panel on Climate Change Fifth Assessment (2014) and incorporates regional factors such as subsidence, distance from melting glaciers and polar ice sheets, and ocean currents. The probability distribution of estimates of relative sea-level rise from the baseline year of 2000 are provided over time and, after 2050, for three different greenhouse gas emissions pathways: Growing Emissions (RCP8.5), Stabilized Emissions (RCP4.5), and meeting the Paris Agreement (RCP2.6). This framework has been recently used in developing relative sea-level rise projections for California, Oregon, Washington, New Jersey, and Delaware as well as several metropolitan areas. The Likely range (66% probability) of the relative rise of mean sea level expected in Maryland between 2000 and 2050 is 0.8 to 1.6 feet, with about a one-in-twenty chance it could exceed 2.0 feet and about a one-in-one hundred chance it could exceed 2.3 feet. Later this century, rates of sea-level rise increasingly depend on the future pathway of global emissions of greenhouse gases during the next sixty years. If emissions continue to grow well into the second half of the 21st century, the Likely range of sea-level rise experienced in Maryland is 2.0 to 4.2 feet over this century, two to four times the sea-level rise experienced during the 20th century. Moreover, there is a one-in-twenty chance that it could exceed 5.2 feet. If, on the other hand, global society were able to bring net greenhouse gas emissions to zero in time to meet the goals of the Paris Climate Agreement and reduce emissions sufficient to limit the increase in global mean temperature to less than 2°Celsius over pre-industrial levels, the Likely range for 2100 is 1.2 to 3.0 feet, with a one-in-twenty chance that it would exceed 3.7 feet. The difference in sea-level rise between these contrasting scenarios would diverge even more during the next century, with the failure to reduce emissions in the near term resulting in much greater sea-level rise 100 years from now. Moreover, recent research suggests that, without imminent and substantial reductions in greenhouse gas emissions, the loss of polar ice sheets-and thus the rate of sea-level rise-may be more rapid than assumed in these projections, particularly under the Growing Emissions scenario. These probabilistic sea-level rise projections can and should be used in planning and regulation, infrastructure siting and design, estimation of changes in tidal range and storm surge, developing inundation mapping tools, and adaptation strategies for high-tide flooding and saltwater intrusion.