Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LORENTZ FORCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

FEA Model and Mechanical Analysis of the Nb 3 Sn 15-T Dipole Demonstrator

Nb$_{3}$Sn magnets with a nominal operation field of ~15 T are being considered for the large hadron collider (LHC) energy upgrade high-energy large hadron collider (HE-LHC) and a post-LHC future circular collider. To demonstrate the feasibility of 15-T accelerator quality dipole magnets, the U.S. magnet development program is developing a single-aperture 15-T Nb$_{3}$Sn dipole demonstrator based on a 4-layer graded cos-theta coil with 60 mm aperture and cold iron yoke. The main design challenges for 15-T accelerator magnets include large Lorentz forces at this field level. To counteract them, an innovative mechanical structure based on a vertically split iron yoke, locked by large aluminum IC-clamps and supported by a thick stainless steel skin, has been developed at Fermilab. To study the performance of the structure, a parametric multiphysics finite element analysis (FEA) model has been set up. This paper describes the numerical model as well as the results of a sensitivity analysis of the effect of geometrical tolerances and assembly parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quench-Back Management for Fast Decaying Currents in SHMS Superconducting Magnets at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) of Hall C, part of the 12-GeV upgrade at Jefferson Lab, was successfully commissioned in 2017. Early operation demonstrated that fast current dumps decays of the SHMS Q2/Q3 and dipole superconducting magnets triggered quenches, causing some level of operational difficulty. Tests and detailed assessments suggest that nonquench induced fast current decay could result in substantial ac loss in the conductor and subsequently trigger a quench-back effect. The OPERA/ELECTRA software package was used to calculate the amount of heat deposited in the copper stabilizer from a fast current decay. The resistances of external energy dump resistors were lowered to slow the fast dumping of the magnet's current to reduce or eliminate the quench-back effect. A worst-case adiabatic quench scenario was analyzed, assuming no external dump resistor and no liquid helium surrounding the coil, to ensure the safety of the magnets. The stress levels in the coil imposed by winding, collaring preload, Lorentz force, and temperature gradient during a quench were also examined. The Tsai-Wu material failure criterion was used to determine the acceptable combined stress level. Linear orthotropic analysis of the coil indicates that the magnets can be operated safely with appropriately sized dump resistors. Fast dump tests with the modified dump resistors have been planned to verify the performance and suitability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and First Test of the 15 T Nb$_3$Sn Dipole Demonstrator MDPCT1

Fermilab in the framework of the U.S. Magnet Devel-opment Program (MDP) has developed a Nb$_3$Sn dipole demonstrator for a post-LHC hadron collider. The magnet uses 60-mm aperture 4-layer shell-type graded coils. The cable in the two inner-most layers has 28 strands 1.0 mm in diameter and the cable in the two outermost layers has 40 strands 0.7 mm in diameter. An inno-vative mechanical structure based on aluminum I-clamps and a thick stainless steel skin is used to preload Nb$_3$Sn coils and support large Lorentz forces. The maximum field for this magnet is limited by 15 T due to mechanical considerations. The first magnet assembly was done with lower coil pre-load to achieve 14 T and minimize the risk of coil damage during assembly. This paper describes the magnet design and the details of its assembly procedure, and re-ports the results of its cold tests.

43 PARTICLE ACCELERATORS↗

Conceptual Design of DUNE Near Detector Superconducting Magnet System

The Deep Underground Neutrino Experiment (DUNE) has formed a near detector design group (NDDG) tasked with delivering a CDR by the end of 2019. The DUNE Near Detectors will be housed in an underground hall on the Fermilab site. The two main detector systems are a liquid argon detector and a high-pressure gas time projection chamber (HPgTPC). The HPgTPC requires a magnet that generates a 0.5 T solenoidal magnetic field in a large volume of 6 m diameter, and 5 m length. Herein, we present a superconducting magnet system design. We investigated: an open air core magnet with three coils, and a five coils system having two active fringe field shielding coils. Coils positions were optimized to obtain the specified field homogeneity in the magnet good field region, while minimizing the Lorentz forces and the superconductor volume. We discuss the magnetic, mechanical, and thermal conceptual designs.

43 PARTICLE ACCELERATORS↗

Redesign of the Coils for the 60T Controlled-Waveform Magnet at NHMFL

Driven by the1.4 GW generator, the 60T Controlled Waveform (60 TCW) magnet was the most powerful controlled waveform system in the world and had always been one of most important magnets to the National High Magnetic Field (NHMFL) and high-field research community because of its following unique features: (1) quasi-static field up to 60 T with 100 ms flat-top and total pulse-length of about 2000 ms, (2) variable magnetic field waveforms such as staircase and triangle with flat-top (3) relative large bore (32 mm) and (4) very fast cooling time (20 minutes) between pulses [Boebinger, 2001], [Crooker et al. 2001]. The magnet is composed of nine concentric coils, with each coil consisting of several conductor winding layers reinforced by a high-strength metallic shell. The magnet underwent a catastrophic failure in 2000 and all the coils had to be rebuilt. In late 2014 the second magnet version failed near the mid-plane of coil 7. The simulations afterward that incident indicated that the overall strength of the coil would be increased by replacing a section of the reinforcing shell with Zylon fiber-epoxy composite. This reduces the stress and thus significantly lowers the level of plastic deformation in the windings. The role of the metal and Zylon fiber reinforcing layers in bearing the axial and radial Lorentz forces has been studied to optimize the magnet design. Here, the results of the optimization will be discussed as well as challenges that have been presented in rebuilding the individual coils of the magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Assembly of a Large-Aperture Nb 3 Sn Cos-Theta Dipole Coil With Stress Management in Dipole Mirror Configuration

The stress-management cos-theta (SMCT) coil is a new concept which has been proposed and is being developed at Fermilab in the framework of US Magnet Development Program (US-MDP) for high-field and/or large-aperture accelerator magnets based on low-temperature and high-temperature superconductors. The SMCT structure is used to reduce large coil deformations under the Lorentz forces and, thus, the excessively large strains and stresses in the coil. A large-aperture Nb 3 Sn SMCT dipole coil has been developed and fabricated at Fermilab to demonstrate and test the SMCT concept including coil design, fabrication technology and performance. The first SMCT coil has been assembled with 60-mm aperture Nb 3 Sn coil inside a dipole mirror configuration and will be tested separately and in series with the insert coil. Here this paper summarizes the large-aperture SMCT coil design and parameters and reports the coil fabrication steps and its assembly in dipole mirror configuration.

43 PARTICLE ACCELERATORS↗

Computation of the Strain Induced Critical Current Reduction in the 16 T Nb 3 Sn Test Facility Dipole

A test facility dipole is being developed at LBNL, targeting a 16 T field in a 144 mm wide aperture. The magnet uses a block design, with two double-pancake coils. In order to minimize motion under the large Lorentz forces, the coils are preloaded against a thick aluminum shell and iron yoke using bladder and key technology. It is then crucial to verify that the performance of the magnet is not degraded due to strain induced on the Nb 3 Sn conductor during assembly, cool-down and powering. The critical current of extracted strands was measured in a varying background magnetic field and as a function of the applied longitudinal strain. Finite element analysis was used to extract the strain state inside the superconducting strands during magnet assembly and operation. This strain was then compared to the measurements to evaluate potential reversible and irreversible effects on the magnet performances. Here the results suggest that the magnet can reach 16 T with sufficient margin, with no irreversible degradation in the high field region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FEM Analysis of Hybrid LTS/HTS Cos-Theta Dipole Magnet With Heterogeneous Cable Model

The Lawrence Berkeley National Laboratory (LBNL) and the National High Magnetic Field Laboratory (NHMFL) have published results on Bi-2212 superconductive magnets realized and tested in the canted cosine-theta and solenoid designs, respectively. Fermilab is now preparing for the assembly of the first Bi-2212 stress-managed cosine-theta insert magnet. The insert will be part of the first hybrid cosine-theta magnet made of Nb$_3$Sn outer layers within the US-MDP effort to reach a 20 T bore field. This paper presents the analytical analysis of the cosine-theta Nb$_3$Sn/Bi-2212 hybrid magnet. We report the parameters, logic, and implementation method of the 2D electromagnetic and mechanical FEM analysis of the LTS/HTS hybrid magnet. Results from a detailed heterogeneous model are compared to the homogeneous model implemented in the past. A Python code has been developed to simulate the current degradation due to stresses in the detail-modeled conductor areas. The current degradation has been introduced in the simulation dynamics for the HTS conductor as an iteration process, updating the input load of Lorentz forces of the energization at each step. The magnetic and mechanical analysis results of the 2D cosine-theta LTS/HTS dipole magnet have been described and analyzed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Design and Construction of a Superconducting “Direct Wind” R&D Magnet for the EIC Interaction Region

Brookhaven National Laboratory (BNL) was chosen to host the international Electron-Ion Collider (EIC), which will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV. The Interaction Region (IR) [1] requires several large aperture, relatively high field superconducting dipole and quadrupole magnets, some of which are very closely spaced.\r\nA value engineering effort is underway as part of the EIC Project to construct and test a Direct Wind magnet [2] (coil comprised of NbTi conductor deposited directly onto a support tube, in this instance tapered, and secured mechanically against Lorentz forces afterwards) to replace two Rutherford cable collared magnets. This magnet exceeds the combination of aperture, number of coil \r\nlayers, and magnetic field, as compared to existing accelerator and R&D Direct Wind magnets to date. Furthermore, construction has been completed using a newly commissioned winding machine, upgraded in anticipation of the upcoming EIC production coil fabrication. Design, analysis, construction issues, lessons learned and accomplishments to date shall be discussed, including the \r\nachieved corrections to multipoles made to successive coil layers based on warm magnetic measurements of preceding layers.

43 PARTICLE ACCELERATORS↗

The Resistive-Wall Instability in Multipulse Linear Induction Accelerators

The resistive-wall instability results from the Lorentz force on the beam due to the beam image charge and current. If the beam pipe is perfectly conducting, the electric force due to the image charge attracts the beam to the pipe wall, and the magnetic force due to the image current repels the beam from the wall. For a relativistic beam, these forces almost cancel, leaving a slight attractive force, which is easily overcome by external magnetic focusing. However, if the beam pipe is not perfectly conducting, the magnetic field due to the image current decays on a magnetic-diffusion time scale. If the beam pulse is longer than the magnetic diffusion time, the repulsion of the beam tail will be weaker than the repulsion of the beam head. In the absence of an external focusing force, this causes a head-to-tail sweep of the beam toward the wall. This instability is usually thought to be a concern only for long-pulse relativistic electron beams. However, with the advent of multipulse, high current linear induction accelerators, the possibility of pulse-to-pulse coupling of this instability should be investigated. Lastly, we have explored pulse-to-pulse coupling using the linear accelerator model for Dual Axis Radiography for Hydrodynamic Testing beam dynamics code, and we present the results of this paper.

43 PARTICLE ACCELERATORS↗

Numerical Analysis of 2-D and 3-D MHD Flows Relevant to Fusion Applications

Here, the analysis of many fusion applications such as liquid-metal blankets requires application of computational fluid dynamics (CFD) methods for electrically conductive liquids in geometrically complex regions and in the presence of a strong magnetic field. A current state of the art general purpose CFD code allows modeling of the flow in complex geometric regions, with simultaneous conjugated heat transfer analysis in liquid and surrounding solid parts. Together with a magnetohydrodynamics (MHD) capability, the general purpose CFD code will be a valuable tool for the design and optimization of fusion devices. This paper describes an introduction of MHD capability into the general purpose CFD code CFX, part of the ANSYS Workbench. The code was adapted for MHD problems using a magnetic induction approach. CFX allows introduction of user-defined variables using transport or Poisson equations. For MHD adaptation of the code three additional transport equations were introduced for the components of the magnetic field, in addition to the Poisson equation for electric potential. The Lorentz force is included in the momentum transport equation as a source term. Fusion applications usually involve very strong magnetic fields, with values of the Hartmann number of up to tens of thousands. In this situation a system of MHD equations become very rigid with very large source terms and very strong variable gradients. To increase system robustness, special measures were introduced during the iterative convergence process, such as linearization using source coefficient for momentum equations. The MHD implementation in general purpose CFD code was tested against benchmarks, specifically selected for liquid-metal blanket applications. Results of numerical simulations using present implementation closely match analytical solutions for a Hartmann number of up to 1500 for a 2-D laminar flow in the duct of square cross section, with conducting and nonconducting walls. Results for a 3-D test case are also included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-E-18C-04: Advanced Computer Simulation and Visualization Tools for Enhanced Understanding of Core Medical Physics Concepts

Purpose: Most medical physics programs emphasize proficiency in routine clinical calculations and QA. The formulaic aspect of these calculations and prescriptive nature of measurement protocols obviate the need to frequently apply basic physical principles, which, therefore, gradually decay away from memory. E.g. few students appreciate the role of electron transport in photon dose, making it difficult to understand key concepts such as dose buildup, electronic disequilibrium effects and Bragg-Gray theory. These conceptual deficiencies manifest when the physicist encounters a new system, requiring knowledge beyond routine activities. Methods: Two interactive computer simulation tools are developed to facilitate deeper learning of physical principles. One is a Monte Carlo code written with a strong educational aspect. The code can “label” regions and interactions to highlight specific aspects of the physics, e.g., certain regions can be designated as “starters” or “crossers,” and any interaction type can be turned on and off. Full 3D tracks with specific portions highlighted further enhance the visualization of radiation transport problems. The second code calculates and displays trajectories of a collection electrons under arbitrary space/time dependent Lorentz force using relativistic kinematics. Results: Using the Monte Carlo code, the student can interactively study photon and electron transport through visualization of dose components, particle tracks, and interaction types. The code can, for instance, be used to study kerma-dose relationship, explore electronic disequilibrium near interfaces, or visualize kernels by using interaction forcing. The electromagnetic simulator enables the student to explore accelerating mechanisms and particle optics in devices such as cyclotrons and linacs. Conclusion: The proposed tools are designed to enhance understanding of abstract concepts by highlighting various aspects of the physics. The simulations serve as virtual experiments that give deeper and long lasting understanding of core principles. The student can then make sound judgements in novel situations encountered beyond routine clinical activities.

60 APPLIED LIFE SCIENCES↗

WE-G-17A-04: Measurements of the Electron-Return-Effect in a Commercial Magnetic Resonance Image Guided Radiation Therapy (MR-IGRT) System

Purpose: The aim of this work was to measure the influences of the Lorentz force (electron return effect) on secondary electron transport in the presence of a low magnetic field produced in a commercial MR-IGRT system using a custom heterogeneous phantom. Methods: A commercial MR-IGRT system has been commissioned in our department. The system combines real-time imaging using a split-bore 0.35-T MRI and three Co-60 heads, each collimated with a doubly-focused MLC. The integrated treatment planning system uses a Monte-Carlo algorithm that models the magnetic field effects on scattered electrons. During commissioning, a custom heterogeneity phantom was designed to acquire ionization chamber and film measurements. The 30 cm cubic phantom consists of two waterfilled annuli, each containing a central region that simulates a 6 cm cubic lung tumor using polystyrene embedded in cork. Film may be placed inbetween the halves, and small-volume ionization chambers may be placed in different positions to measure dose to the tumor and near interfaces where the electron return effect is expected. The treatment planning system was used to create open-field and IMRT treatment plans on a CT scan of the phantom. Plans were delivered to the phantom, and radiographic film and ionization chamber measurements were obtained. Results: The mean ionization chamber measured dose ratio for 27 measurements for 5 plans was 0.993 ± 0.027. Lateral profile film measurements confirm that the electron-return-effect is observable, producing local dose variations of less than 10% over 5 mm with 0.35 T magnetic field for single field treatment plans. The effect becomes negligible for opposing-field and IMRT treatments. Conclusion: A heterogeneous phantom for measurement of the electron-return-effect has been designed. Ionization chamber and film measurements made with the phantom indicate that the dosimetric effect is minimal, and the treatment planning system predicts dose reasonably well for complex heterogeneous scenarios.

60 APPLIED LIFE SCIENCES↗

Breast dosimetry in transverse and longitudinal field MRI-Linac radiotherapy systems

Purpose: In the framework of developing the integration of a MRI-Linac system, configurations of MRI-Linac units were simulated in order to improve the dose distribution in tangential breast radiotherapy using transverse and longitudinal magnetic field geometries of Lorentz force for both medial and lateral tangential fields. Methods: In this work, the GEANT4 Monte Carlo (MC) code was utilized to compare dose distributions in breast radiotherapy for Linac-MR systems in the transverse and longitudinal geometries within humanoid phantoms across a range of magnetic field strengths of 0.5 and 1.5 T. The dose increment due to scattering from the coils was investigated for both geometries as well. Computed tomography images of two patients were used for MC simulations. One patient had intact breast while the other was mastectomized. In the simulations, planning and methods of chest wall irradiation were similar to the actual clinical planning. Results: In a longitudinal geometry, the magnetic field is shown to restrict the lateral spread of secondary electrons to the lung, heart, and contralateral organs, which reduced the mean dose of the ipsilateral lung and heart by means of 17.2% and 6% at 1.5 T, respectively. The transverse configuration exhibits a significant increase in tissue interface effects, which increased dose buildup in the entrance regions of the lateral and medial tangent beams to the planning target volume (PTV) and improved dose homogeneity within the PTV. The improved relative average homogeneity index for two patients to the PTV at magnetic field strength of 1.5 T with respect to no magnetic field case evaluated was 11.79% and 34.45% in the LRBP and TRBP geometries, respectively. In both geometries, the simulations show significant mean dose reductions in the contralateral breast and chest wall skin, respectively, by a mean of 16.6% and 24.9% at 0.5 T and 17.2% and 28.1% at 1.5 T in the transverse geometry, and 10.56% and 14.6% at 0.5 T and 11.3% and 16.3% at 1.5 T in the longitudinal geometry. Considering the scattered photons which reflected from the coils, the average relative dose of each voxel is slightly increased by 0.53% and 0.32% in the LRBP and TRBP geometries, respectively. Conclusions: Orienting the B0 magnetic field parallel to the photon beam axis, LRBP geometry, tends to restrict the radial spread of secondary electrons which resulted in dose reduction to the lung. Dosimetry issues observed in both Linac-MR geometries, such as changes to the lateral dose distribution, significantly exhibited dose reduction in the contralateral organs on a representative breast plan. Further, the results show sharper edge dose volume histogram curves at 1.5 T for both geometries, especially in the LRBP configuration.

60 APPLIED LIFE SCIENCES↗

SU-E-J-198: Out-Of-Field Dose and Surface Dose Measurements of MRI-Guided Cobalt-60 Radiotherapy

Purpose: To measure quantities of dosimetric interest in an MRI-guided cobalt radiotherapy machine that was recently introduced to clinical use. Methods: Out-of-field dose due to photon scatter and leakage was measured using an ion chamber and solid water slabs mimicking a human body. Surface dose was measured by irradiating stacks of radiochromic film and extrapolating to zero thickness. Electron out-of-field dose was characterized using solid water slabs and radiochromic film. Results: For some phantom geometries, up to 50% of Dmax was observed up to 10 cm laterally from the edge of the beam. The maximum penetration was between 1 and 2 mm in solid water, indicating an electron energy not greater than approximately 0.4 MeV. Out-of-field dose from photon scatter measured at 1 cm depth in solid water was found to fall to less than 10% of Dmax at a distance of 1.2 cm from the edge of a 10.5 × 10.5 cm field, and less that 1% of Dmax at a distance of 10 cm from field edge. Surface dose was measured to be 8% of Dmax. Conclusion: Surface dose and out-of-field dose from the MRIguided cobalt radiotherapy machine was measured and found to be within acceptable limits. Electron out-of-field dose, an effect unique to MRI-guided radiotherapy and presumed to arise from low-energy electrons trapped by the Lorentz force, was quantified. Dr. Low is a member of the scientific advisory board of ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators

Purpose: The purpose of this work was to adapt a lightweight, permanent magnet electron energy spectrometer for the measurement of energy spectra of therapeutic electron beams. Methods: An irradiation geometry and measurement technique were developed for an approximately 0.54-T, permanent dipole magnet spectrometer to produce suitable latent images on computed radiography (CR) phosphor strips. Dual-pinhole electron collimators created a 0.318-cm diameter, approximately parallel beam incident on the spectrometer and an appropriate dose rate at the image plane (CR strip location). X-ray background in the latent image, reduced by a 7.62-cm thick lead block between the pinhole collimators, was removed using a fitting technique. Theoretical energy-dependent detector response functions (DRFs) were used in an iterative technique to transform CR strip net mean dose profiles into energy spectra on central axis at the entrance to the spectrometer. These spectra were transformed to spectra at 95-cm source to collimator distance (SCD) by correcting for the energy dependence of electron scatter. The spectrometer was calibrated by comparing peak mean positions in the net mean dose profiles, initially to peak mean energies determined from the practical range of central-axis percent depth-dose (%DD) curves, and then to peak mean energies that accounted for how the collimation modified the energy spectra (recalibration). The utility of the spectrometer was demonstrated by measuring the energy spectra for the seven electron beams (7–20 MeV) of an Elekta Infinity radiotherapy accelerator. Results: Plots of DRF illustrated their dependence on energy and position in the imaging plane. Approximately 15 iterations solved for the energy spectra at the spectrometer entrance from the measured net mean dose profiles. Transforming those spectra into ones at 95-cm SCD increased the low energy tail of the spectra, while correspondingly decreasing the peaks and shifting them to slightly lower energies. Energy calibration plots of peak mean energy versus peak mean position of the net mean dose profiles for each of the seven electron beams followed the shape predicted by the Lorentz force law for a uniform z-component of the magnetic field, validating its being modeled as uniform (0.542 ± 0.027 T). Measured Elekta energy spectra and their peak mean energies correlated with the 0.5-cm (7–13 MeV) and the 1.0-cm (13–20 MeV) R{sub 90} spacings of the %DD curves. The full-width-half-maximum of the energy spectra decreased with decreasing peak mean energy with the exception of the 9-MeV beam, which was anomalously wide. Similarly, R{sub 80–20} decreased linearly with peak mean energy with the exception of the 9 MeV beam. Both were attributed to suboptimal tuning of the high power phase shifter for the recycled radiofrequency power reentering the traveling wave accelerator. Conclusions: The apparatus and analysis techniques of the authors demonstrated that an inexpensive, lightweight, permanent magnet electron energy spectrometer can be used for measuring the electron energy distributions of therapeutic electron beams (6–20 MeV). The primary goal of future work is to develop a real-time spectrometer by incorporating a real-time imager, which has potential applications such as beam matching, ongoing beam tune maintenance, and measuring spectra for input into Monte Carlo beam calculations.

60 APPLIED LIFE SCIENCES↗

Charged particle transport in magnetic fields in EGSnrc

Purpose: To accurately and efficiently implement charged particle transport in a magnetic field in EGSnrc and validate the code for the use in phantom and ion chamber simulations. Methods: The effect of the magnetic field on the particle motion and position is determined using one- and three-point numerical integrations of the Lorentz force on the charged particle and is added to the condensed history calculation performed by the EGSnrc PRESTA-II algorithm. The code is tested with a Fano test adapted for the presence of magnetic fields. The code is compatible with all EGSnrc based applications, including egs++. Ion chamber calculations are compared to experimental measurements and the effect of the code on the efficiency and timing is determined. Results: Agreement with the Fano test’s theoretical value is obtained at the 0.1% level for large step-sizes and in magnetic fields as strong as 5 T. The NE2571 dose calculations achieve agreement with the experiment within 0.5% up to 1 T beyond which deviations up to 1.2% are observed. Uniform air gaps of 0.5 and 1 mm and a misalignment of the incoming photon beam with the magnetic field are found to produce variations in the normalized dose on the order of 1%. These findings necessitate a clear definition of all experimental conditions to allow for accurate Monte Carlo simulations. It is found that ion chamber simulation times are increased by only 38%, and a 10 × 10 × 6 cm{sup 3} water phantom with (3 mm){sup 3} voxels experiences a 48% increase in simulation time as compared to the default EGSnrc with no magnetic field. Conclusions: The incorporation of the effect of the magnetic fields in EGSnrc provides the capability to calculate high accuracy ion chamber and phantom doses for the use in MRI-radiation systems. Further, the effect of apparently insignificant experimental details is found to be accentuated by the presence of the magnetic field.

60 APPLIED LIFE SCIENCES↗