Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOCATION CLOSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization NPIC presentation

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hybrid method for quasi-three-dimensional slope stability analysis in a municipal solid waste landfill

Highlights: > A quasi-three-dimensional slope stability analysis method was proposed. > The proposed method is a good engineering tool for 3D slope stability analysis. > Factor of safety from 3D analysis is higher than from 2D analysis. > 3D analysis results are more sensitive to cohesion than 2D analysis. - Abstract: Limited space for accommodating the ever increasing mounds of municipal solid waste (MSW) demands the capacity of MSW landfill be maximized by building landfills to greater heights with steeper slopes. This situation has raised concerns regarding the stability of high MSW landfills. A hybrid method for quasi-three-dimensional slope stability analysis based on the finite element stress analysis was applied in a case study at a MSW landfill in north-east Spain. Potential slides can be assumed to be located within the waste mass due to the lack of weak foundation soils and geosynthetic membranes at the landfill base. The only triggering factor of deep-seated slope failure is the higher leachate level and the relatively high and steep slope in the front. The valley-shaped geometry and layered construction procedure at the site make three-dimensional slope stability analyses necessary for this landfill. In the finite element stress analysis, variations of leachate level during construction and continuous settlement of the landfill were taken into account. The 'equivalent' three-dimensional factor of safety (FoS) was computed from the individual result of the two-dimensional analysis for a series of evenly spaced cross sections within the potential sliding body. Results indicate that the hybrid method for quasi-three-dimensional slope stability analysis adopted in this paper is capable of locating roughly the spatial position of the potential sliding mass. This easy to manipulate method can serve as an engineering tool in the preliminary estimate of the FoS as well as the approximate position and extent of the potential sliding mass. The result that FoS obtained from three-dimensional analysis increases as much as 50% compared to that from two-dimensional analysis implies the significance of the three-dimensional effect for this study-case. Influences of shear parameters, time elapse after landfill closure, leachate level as well as unit weight of waste on FoS were also investigated in this paper. These sensitivity analyses serve as the guidelines of construction practices and operating procedures for the MSW landfill under study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring the Presence and Location of Metallic Components Inside a Fuel Element

A non-destructive method of monitoring the presence and location of metallic components in a fuel element is proposed. It is shown that a nickel plug can be identified by modernizing the measurement procedure. A method of performing measurements is described and the results of experimental studies are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Lidar Altimeter Measurements of Canopy Structure: Methods and Validation for Closed Canopy, Broadleaf Forests

Lidar altimeter observations of vegetated landscapes provide a time-resolved measure of laser pulse backscatter energy from canopy surfaces and the underlying ground. Airborne lidar altimeter data was acquired using the Scanning Lidar Imager of Canopies by Echo Recovery (SLICER) for a successional sequence of four, closed-canopy, deciduous forest stands in eastern Maryland. The four stands were selected so as to include a range of canopy structures of importance to forest ecosystem function, including variation in the height and roughness of the outer-most canopy surface and the vertical organization of canopy stories and gaps. The character of the SLICER backscatter signal is described and a method is developed that accounts for occlusion of the laser energy by canopy surfaces, transforming the backscatter signal to a canopy height profile (CHP) that quantitatively represents the relative vertical distribution of canopy surface area. The transformation applies an increased weighting to the backscatter amplitude as a function of closure through the canopy and assumes a horizontally random distribution of the canopy components. SLICER CHPs, averaged over areas of overlap where lidar ground tracks intersect, are shown to be highly reproducible. CHP transects across the four stands reveal spatial variations in vegetation, at the scale of the individual 10 m diameter laser footprints, within and between stands. Averaged SLICER CHPs are compared to analogous height profile results derived from ground-based sightings to plant intercepts measured on plots within the four stands. Tbe plots were located on the segments of the lidar ground tracks from which averaged SLICER CHPs were derived, and the ground observations were acquired within two weeks of the SLICER data acquisition to minimize temporal change. The differences in canopy structure between the four stands is similarly described by the SLICER and ground-based CHP results, however a Chi-square test of similarity documents differences that are statistically significant. The differences are discussed in terms of measurement properties that define the smoothness of the resulting CHPs and Lidar Altimeter Measurements of Canopy Structure - Harding et al. canopy properties that may vertically bias the CHP representations of canopy structure. The statistical differences are most likely due to the more noisy character of the ground-based CHPs, especially high in the canopy where ground-based sightings are rare resulting in an underestimate of canopy surface area and height, and to departures from the assumption of horizontal randomness which bias the CHPs toward the observer (upward for SLICER and downward for ground-based CHPs). The results demonstrate that the SLICER observations reliably provide a measure of canopy structure that reveals ecologically interesting structural variations such as those characterizing a successional sequence of closed-canopy, broadleaf forest stands.

Harding, D. J.↗

Using ASCEM Modeling and Visualization to Inform Stakeholders of Contaminant Plume Evolution and Remediation Efficacy at F-Basin Savannah River, SC – 15156

Communication with stakeholders, regulatory agencies, and the public is an essential part of implementing different remediation and monitoring activities, and developing site closure strategies at contaminated sites. Modeling of contaminant plume evolution plays a critical role in estimating the benefit, cost, and risk of particular options. At the same time, effective visualization of monitoring data and modeling results are particularly important for conveying the significance of the results and observations. In this paper, we present the results of the Advanced Simulation Capability for Environmental Management (ASCEM) project, including the discussion of the capabilities of newly developed ASCEM software package, along with its application to the F-Area Seepage Basins located in the U.S. Department of Energy Savannah River Site (SRS). ASCEM software includes state-of-the-art numerical methods for simulating complex flow and reactive transport, as well as various toolsets such as a graphical user interface (GUI), visualization, data management, uncertainty quantification, and parameter estimation. Using this software, we have developed an advanced visualization of tritium plume migration coupled with a data management system, and simulated a three-dimensional model of flow and plume evolution on a high-performance computing platform. We evaluated the effect of engineered flow barriers on a nonreactive tritium plume, through advanced plume visualization and modeling of tritium plume migration. In addition, we developed a geochemical reaction network to describe complex geochemical processes at the site, and evaluated the impact of coupled hydrological and geochemical heterogeneity. These results are expected to support SRS’s monitoring activities and operational decisions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using ASCEM modeling and visualization to inform stakeholders of contaminant plume evolution and remediation efficacy at F-Basin Savannah river, SC - 15156

Communication with stakeholders, regulatory agencies, and the public is an essential part of implementing different remediation and monitoring activities, and developing site closure strategies at contaminated sites. Modeling of contaminant plume evolution plays a critical role in estimating the benefit, cost, and risk of particular options. At the same time, effective visualization of monitoring data and modeling results are particularly important for conveying the significance of the results and observations. In this paper, we present the results of the Advanced Simulation Capability for Environmental Management (ASCEM) project, including the discussion of the capabilities of newly developed ASCEM software package, along the its application to the F-Area Seepage Basins located in the U.S. Department of Energy Savannah River Site (SRS). ASCEM software includes state-of-the-art numerical methods for simulating complex flow and reactive transport, as well as various tool-sets such as a graphical user interface (GUI), visualization, data management, uncertainty quantification, and parameter estimation. Using this software, we have developed an advanced visualization of tritium plume migration coupled with a data management system, and simulated a three-dimensional model of flow and plume evolution on a high-performance computing platform. We evaluated the effect of engineered flow barriers on a nonreactive tritium plume, through advanced plume visualization and modeling of tritium plume migration. In addition, we developed a geochemical reaction network to describe complex geochemical processes at the site, and evaluated the impact of coupled hydrological and geochemical heterogeneity. These results are expected to support SRS's monitoring activities and operational decisions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Statistical Analysis Of Tank 5 Floor Sample Results (U)

Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Post-Closure Inspection and Monitoring Report for Corrective Action Unit 417: Central Nevada Test Area Surface, Hot Creek Valley, Nevada

This report presents results of data collected during the annual post-closure site inspection conducted at the Central Nevada Test Area, surface Corrective Action Unit (CAU) 417 in June 2009. The annual post-closure site inspection included inspections of the UC-1, UC-3, and UC-4 sites in accordance with the Post-Closure Monitoring Plan provided in the CAU 417 Closure Report (NNSA/NV 2001). The annual inspection conducted at the UC-1 Central Mud Pit (CMP) indicated that the site and soil cover were in good condition. Three new fractures were identified in the soil cover and were filled with bentonite chips during the inspection. The vegetation on the soil cover was adequate but showed signs of the area's ongoing drought. No issues were identified with the CMP fence, gate, or subsidence monuments. No issues were identified with the warning signs and monuments at the other two UC-1 locations

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Decision Document/Closure Report for Corrective Action Unit 371: Johnnie Boy Crater and Pin Stripe Nevada Test Site, Nevada, Revision 0 with ROTC 1

This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit 371, Johnnie Boy Crater and Pin Stripe, located within Areas 11 and 18 at the Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit (CAU) 371 comprises two corrective action sites (CASs): • 11-23-05, Pin Stripe Contamination Area • 18-45-01, U-18j-2 Crater (Johnnie Boy) The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 371 based on the implementation of corrective actions. The corrective action of closure in place with administrative controls was implemented at both CASs. Corrective action investigation (CAI) activities were performed from January 8, 2009, through February 16, 2010, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 371: Johnnie Boy Crater and Pin Stripe. The approach for the CAI was divided into two facets: investigation of the primary release of radionuclides and investigation of other releases (migration in washes and chemical releases). The purpose of the CAI was to fulfill data needs as defined during the data quality objective (DQO) process. The CAU 371 dataset of investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the dataset is acceptable for use in fulfilling the DQO data needs. Analytes detected during the CAI were evaluated against final action levels (FALs) established in this document. Radiological doses exceeding the FAL of 25 millirem per year were not found to be present in the surface soil. However, it was assumed that radionuclides are present in subsurface media within the Johnnie Boy crater and the fissure at Pin Stripe. Due to the assumption of radiological dose exceeding the FAL, corrective actions were undertaken that consist of implementing a use restriction and posting warning signs at each site. These use restrictions were recorded in the FFACO database; the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Facility Information Management System; and the NNSA/NSO CAU/CAS files. Therefore, NNSA/NSO provides the following recommendations: • No further corrective actions are necessary for CAU 371. • A Notice of Completion to NNSA/NSO is requested from the Nevada Division of Environmental Protection for closure of CAU 371. • Corrective Action Unit 371 should be moved from Appendix III to Appendix IV of the FFACO.

54 ENVIRONMENTAL SCIENCES↗

Airborne Radar Observations of Hurricane Georges during Landfall over the Dominican Republic

On 22 September 1998 hurricane Georges made landfall on the Dominican Republic (DR). Georges cost the DR at least 500 lives, made more than 155,000 people homeless and caused extensive damage to the country's main industries, tourism and agriculture. There was considerable wind damage, with wind gusts up to 58 m/s in Santa Domingo on the south coast, but most of the damage and deaths resulted from mudslides and the flooding of rivers. While this may have been the worst natural disaster to strike the DR, the sustained rapid storm movement saved the island from worse damage. Georges had previously affected several islands in the Lesser Antilles and Puerto Rico, but it had retained much of its circulation strength. Forty raingauge stations across the DR measured rainfall totals from Georges between 0.7 and 41 cm, the latter at the capital Santo Domingo, located on the south coast. At Herrera the maximum 1 h rainfall rate was 72 mm/h. It is suspected that much higher rain rates occurred in DR's mountainous interior. Before landfall the eye was clearly evident in satellite imagery. When the eye moved over southeastern DR, it filled rapidly, and the cloud top height decreased in all storm sectors except in the southern inflow sector, where a long-lived MCS, with a diameter larger than that of the eyewall, slowly became enwrapped in the hurricane circulation. The eye closure was most rapid between 16-18 UTC, when the eyewall circulation felt the mountainous terrain of the Cordillera Central, which rises up to 3,093 m. The estimated central pressure increased from 962 hPa at 15 UTC to 986 hPa at 03Z on 23 Sept, and the maximum sustained surface wind speed decreased from 54 to 36 in s-1 during the same period. The island of Hispaniola has a cross-track width of about 250 km, much wider than the diameter of the eyewall anvil (about 100 km before landfall). So the event can truly be considered to be a landfalling case, even though Georges recovered after crossing Hispaniola, albeit never to the same strength. This talk will summarize satellite and ground observations of Georges, as it passed the DR, and it will focus on EDOP data. In particular, we will try to estimate the rainfall rate over the mountainous terrain of the DR. And we will use detailed sounding data to explain the presence and characteristics of the massive MCS to the south, as well as the upper-level updrafts apparent over this MCS and over the mountains of the DR.

Geerts, B.↗

SRS Strategy for Tank 3 Salt Dissolution - Performance and Lessons Learned - 20441

The Savannah River Site (SRS) Tank Farms have 51 underground waste tanks used to store and process liquid nuclear waste materials. There are 4 different tank types, ranging in capacity from 2,840,000 to 4,920,000 L (750,000 to 1,300,000 Gal). Twenty-four of the tanks are older style and do not meet full secondary containment standards. The older style tanks are the initial focus of waste removal efforts for tank closure at SRS. Eight of these twenty-four tanks have completed waste removal and are filled with grout. Prior to salt dissolution, Tank 3 was a dry salt tank that contained 5.06 m (199.3 in) of salt and sludge waste. Additional salt waste was present on cooling coils above the salt layer up to approximately 5.59 m (220 in). Three mixing eductors were installed in Tank 3 to aid in dissolving salt waste in three tank riser access ports. A transfer pump was installed, and the transfer pump suction was located 25.4 cm (10 in) from the tank bottom. Well water was added to the tank through a downcomer until the dry bulk salt was covered with liquid. During the initial fill of Tank 3, approximately 242,000 L (64,000 Gal) of rain water were added from periodic F-Tank Farm (FTF) Catch Tank additions and approximately 17,000 L (4,500 Gal) of well water were added. Following liquid additions to cover the dry bulk salt, well water was added through the three mixing eductors in batches during each stage. Additionally, during the salt dissolution campaigns, the FTF Catch Tank was utilized to add rain water through a downcomer in the center tank riser access port as needed for volume relief in the FTF Catch Tank. Following liquid additions, the water was recirculated (internal to the tank) using the transfer pump, and a sample was pulled to confirm the target specific gravity (SpG) of the dissolved salt solution was achieved. The dissolved salt solution was then transferred to the receipt tank (Tank 7), and the mixing eductors were lowered as close to the new bulk salt layer as possible, to support subsequent dissolution campaigns. While the mixing jets were able to dissolve salt successfully in Tank 3, they did not do so in a completely uniform manner. Throughout dissolution, mounds were discovered under Riser 1, Riser 2, and the Center Riser. The mixing jets dissolved the salt around the edges of the tank well but were not as effective toward the center of the tank. FTF Catch Tank additions through the center tank riser access port downcomer were required to impact the mound under the center tank riser. FTF Catch Tank additions were sporadic as they were dependent on rainfall in the area. Additionally, all mixing jets were rarely able to be lowered to the same elevation, indicating some mounding in the bulk salt layer. Indexing of the mixing jets was also utilized to impact the salt mounds. Overall, Tank 3 salt dissolution was successful as approximately 1,476,000 L (390,000 Gal) of dissolved salt solution was transferred to Tank 7 over six stages. Slightly less than 852,000 L (225,000 Gal) of water were added to Tank 3. The original material balance prediction estimated that the bulk salt level in Tank 3 would be 3.88 m (152.8 in) after six salt dissolution stages. After six stages the actual bulk salt level was 3.38 m (133 in). This paper will discuss the salt removal strategy, each salt dissolution stage, and lessons learned for future salt dissolution. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenge Problem 1: Preliminary Results of the Direct Numerical Simulation of Transient Flows

This report presents the first direct numerical simulations (DNS) of transient mixed convection in an idealized downcomer-like channel (Challenge Problem 1, Phase II). Using the GPU-accelerated NekRS solver, we modeled a sudden decay in driving pressure, mimicking loss-of-flow events, and tracked the resulting evolution of Reynolds number, boundary-layer structure, turbulence statistics, and heat-transfer metrics. Key findings include the systematic thickening and eventual asymmetry of velocity and thermal boundary layers under buoyant deceleration; minimal “memory” lag in Reynolds shear stress and TKE profiles when sampled at matching Re, yet clear shifts of peak locations toward the cooled wall; overshoots in transient eddy-viscosity and eddy-diffusivity (and corresponding sub-unity turbulent Prandtl numbers) on the cooled side; and a pronounced transient Nusselt-number enhancement driven by wall-temperature inertia and residual eddy mixing. These effects combined to offer a temporary cooling margin above steady-state predictions during reactor LOF transients. Future work will extend this work to a more complex “Case II” geometry (90° turn + lower plenum) and generate multi-Re/Pr datasets for data-driven turbulence closures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Assessment for Closure of the Calcined Solids Storage Facility at the INL Site - 19289

The Calcined Solids Storage Facility is composed of six discrete stainless steel 'bin sets' at the Idaho Nuclear Technology and Engineering Center at the INL Site. Approximately 4,440 m{sup 3} of the dry, granular calcine waste is stored in the facility. Closure of the facility will entail removal of the calcine waste followed by grouting. A 5-cm thick residual amount of calcine was assumed to remain at the bottom of the bins. Important radionuclides in the residual layer for the groundwater pathway were identified as the fission and activation products Tc-99, Se-79, I-129, Cs-135, H-3, and actinides Pu-239, and Pu-240. The stainless-steel bins prevent near-term release of grouted residual calcine waste to the environment. Future releases were conservatively based on the corrosion rate of the weld seams on the stainless-steel bins, which site-specific studies measured mean tunnel corrosion rates of 0.0132 mm/yr with a coefficient of variation of 0.333. Based on tunnel corrosion rates, mean bin hydrologic containment times were estimated to be between 238 years and 1,191 years, depending on the thickness of the bin. Any breach in the weld seam was assumed to result in water flow and radionuclide leaching through the bin. The structural integrity of the bin was assumed to be controlled by the general stainless-steel corrosion rate, which was much slower (3.5 x 10{sup -5} mm/yr), resulting in structural integrity times between 24,000 years to over 100,000 years. A mixing-cell model was used to compute water flow and transport through the hydrologically failed bins and the vadose zone. Credit was taken for the geochemical properties of the grout used to fill the bins at closure, which significantly slows the releases from the bins for key radionuclides like Tc-99. A semi-analytical model for three-dimensional dissolved-phase transport in an aquifer of constant unidirectional flow, infinite length and width, and finite thickness was used to compute concentrations in the aquifer across the model domain for a time varying source. Cumulative impacts from all bin sets were calculated by summation across the bin set sources that were superimposed on a uniform Cartesian grid. Effective doses were calculated for direct groundwater ingestion from wells located 100-m downgradient from each of the bin sets and ingestion of meat, milk, and vegetables irrigated with water derived from the well. Intruder doses were based on a well drilled through the grouted waste and cuttings spread around a home site after a 500-year institutional control period. Peak doses during the 1,000-year compliance period were less than 5% of the 250 μSv/yr (25 mrem/yr) performance objective and intruder doses were generally less 5% of the of the 5000 μSv/yr (500 mrem) and 1000 μSv/yr (100 mrem) performance objective for acute and chronic intruder exposure, respectively. Groundwater concentrations were all less than the maximum contaminant limits. In all cases, doses were highest for the oldest bin set because, compared to the other bin sets, it had the highest radionuclide concentrations in the calcine waste. The performance assessment results indicate that performance objectives can be met leaving considerably more than 5-cm of residual calcine waste in the bin sets. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Blue Ribbon Commission, Yucca Mountain Closure, Court Actions - Future of Decommissioned Reactors, Operating Reactors and Nuclear Power - 13249

Issues related to back-end of the nuclear fuel cycle continue to be difficult for the commercial nuclear power industry and for the decision makers at the national and international level. In the US, the 1982 NWPA required DOE to develop geological repositories for SNF and HLW but in spite of extensive site characterization efforts and over ten billion dollars spent, a repository opening is nowhere in sight. There has been constant litigation against the DOE by the nuclear utilities for breach of the 'standard contract' they signed with the DOE under the NWPA. The SNF inventory continues to rise both in the US and globally and the nuclear industry has turned to dry storage facilities at reactor locations. In US, the Blue Ribbon Commission on America's Nuclear Future issued its report in January 2012 and among other items, it recommends a new, consent-based approach to siting of facilities, prompt efforts to develop one or more geologic disposal facilities, and prompt efforts to develop one or more consolidated storage facilities. In addition, the March 2011 Fukushima Daiichi accident had a severe impact on the future growth of nuclear power. The nuclear industry is focusing on mitigation strategies for beyond design basis events and in the US, the industry is in the process of implementing the recommendations from NRC's Near Term Task Force. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conceptual Design for a Short-Lived Low- and Intermediate-Level Waste Repository at the Al Tuwaitha Nuclear Center, Baghdad, Iraq - 17189

The European Commission under their Instrument for Nuclear Safety Cooperation (INSC) has initiated a project supporting Iraq's efforts for the safe disposal of short lived low- and intermediate-level radioactive waste (SL-LILW) arising from the decommissioning of Iraqi nuclear installations. The INSC project includes both the development of an initial conceptual level basic design and preliminary safety assessment (PSAR) report and the subsequent detailed engineering design and supporting intermediate safety assessment report (ISAR). The project is being executed by a Consortium led by NUKEM Technologies Engineering Services GmbH and joined by DBE Technology GmbH of Germany; JAVYS a.s. of Slovakia and MCM Environmental Services Ltd of the United Kingdom. The current paper focuses on the development of the conceptual level basic design. In previous decades Iraq had a significant nuclear program which encompassed ten nuclear sites spread out across the country. The largest site was located at the Al-Tuwaitha site near Baghdad where 18 nuclear facilities were located. The facilities suffered significant damage from bombing and subsequent looting during the first Gulf War in 1991. Currently, the Ministry of Science and Technology (MoST) is the radioactive waste management operator in Iraq and also the license holder for the ten Iraqi nuclear sites, all of them heavily damaged. Because of the ongoing security concerns in Iraq MoST has selected the Al Tuwaitha Nuclear Center as the preferred and best suited location for development of an SL-LILW repository. As an initial step in development of the conceptual design various repository design options for the site were examined and assessed. The assessment considered similar facilities that have been implemented internationally. At the conclusion of the assessment and in conjunction with the Iraqi Beneficiaries from MoST, a near-surface vault design was selected for the facility. The design of the facility relies on experience gained from existing low-level waste repositories at Centre de l'Aube in France and the El Cabril solid radioactive waste disposal facility in Spain as well as on more recent experience gained in the design of the Bulgaria National Disposal Facility (NDF) under construction near the Kozloduy Nuclear Power Plant. Similar to these reference designs, the concept for the Al Tuwaitha Disposal Facility (ATDF) will rely on a series of reinforced concrete vaults into which containerised waste will be placed. Each vault will consist of two chambers designed specifically to hold the waste. Central drainage points in each waste chamber will lead to an infiltration water collection system designed to detect any failures in the waste containment. Each disposal vault will be sealed after filling by installation of a reinforced concrete closure slab. Once all of the waste has been disposed of the site will be decommissioned and a multilayer protective cover will be installed over the sealed disposal vaults. The multilayer cover will act to further isolate the waste from the environment by limiting the access of water to the waste. Due in part to the presence of shallow groundwater at the site and to avoid potential damage to the facility by flooding from the nearby Tigris River the concept for the Al Tuwaitha Disposal Facility requires construction of the disposal vaults on a raised platform several meters above ground level. Construction of this platform will be integrated into the conceptual safety design and materials will be selected which further enhance the isolation function of the disposal system by hindering or delaying the release of radionuclides to the environment. The infiltration water collection system, which will be constructed in a specifically designed accessible gallery embedded and fully integrated into the platform, will provide access to inspection points located beneath each disposal chamber. The ATDF when completed will be a further demonstration of the adaptability of the disposal vault concept for use in isolating SL-LILW from the environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CO2 response screen in grass Brachypodium reveals the key role of a MAP kinase in CO2-triggered stomatal closure

Abstract Plants respond to increased CO2 concentrations through stomatal closure, which can contribute to increased water use efficiency. Grasses display faster stomatal responses than eudicots due to dumbbell-shaped guard cells flanked by subsidiary cells working in opposition. However, forward genetic screening for stomatal CO2 signal transduction mutants in grasses has yet to be reported. The grass model Brachypodium distachyon is closely related to agronomically important cereal crops, sharing largely collinear genomes. To gain insights into CO2 control mechanisms of stomatal movements in grasses, we developed an unbiased forward genetic screen with an EMS-mutagenized B. distachyon M5 generation population using infrared imaging to identify plants with altered leaf temperatures at elevated CO2. Among isolated mutants, a “chill1” mutant exhibited cooler leaf temperatures than wild-type Bd21-3 parent control plants after exposure to increased CO2. chill1 plants showed strongly impaired high CO2-induced stomatal closure despite retaining a robust abscisic acid-induced stomatal closing response. Through bulked segregant whole-genome sequencing analyses followed by analyses of further backcrossed F4 generation plants and generation and characterization of sodium azide and CRISPR-cas9 mutants, chill1 was mapped to a protein kinase, Mitogen-Activated Protein Kinase 5 (BdMPK5). The chill1 mutation impaired BdMPK5 protein-mediated CO2/HCO3− sensing together with the High Temperature 1 (HT1) Raf-like kinase in vitro. Furthermore, AlphaFold2-directed structural modeling predicted that the identified BdMPK5-D90N chill1 mutant residue is located at the interface of BdMPK5 with the BdHT1 Raf-like kinase. BdMPK5 is a key signaling component that mediates CO2-induced stomatal movements and is proposed to function as a component of the primary CO2 sensor in grasses.

Lopez, Bryn N. K. (ORCID:0009000937288216)↗

Atmospheric Drivers of Wind Turbine Blade Leading Edge Erosion: Review and Recommendations for Future Research

Leading edge erosion (LEE) of wind turbine blades causes decreased aerodynamic performance leading to lower power production and revenue and increased operations and maintenance costs. LEE is caused primarily by materials stresses when hydrometeors (rain and hail) impact on rotating blades. The kinetic energy transferred by these impacts is a function of the precipitation intensity, droplet size distributions (DSD), hydrometeor phase and the wind turbine rotational speed which in turn depends on the wind speed at hub-height. Hence, there is a need to better understand the hydrometeor properties and the joint probability distributions of precipitation and wind speeds at prospective and operating wind farms in order to quantify the potential for LEE and the financial efficacy of LEE mitigation measures. However, there are relatively few observational datasets of hydrometeor DSD available for such locations. Here, we analyze six observational datasets from spatially dispersed locations and compare them with existing literature and assumed DSD used in laboratory experiments of material fatigue. We show that the so-called Best DSD being recommended for use in whirling arm experiments does not represent the observational data. Neither does the Marshall Palmer approximation. We also use these data to derive and compare joint probability distributions of drivers of LEE; precipitation intensity (and phase) and wind speed. We further review and summarize observational metrologies for hydrometeor DSD, provide information regarding measurement uncertainty in the parameters of critical importance to kinetic energy transfer and closure of data sets from different instruments. A series of recommendations are made about research needed to evolve towards the required fidelity for a priori estimates of LEE potential.

17 WIND ENERGY↗