Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEVEL WIDTHS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Progress on precision measurements of inner shell transitions in highly charged ions at an ECR ion source

Inner shell transitions of highly charged ions produced in the plasma of an Electron Cyclotron Resonance Ion Source (ECRIS) were observed the first time by a Double Crystal Spectrometer (DCS). The DCS is a well-used tool in precision x-ray spectroscopy due to its ability of precision wavelength measurement traced back to a relative angle measurement. Because of its requirement for a bright x-ray source the DCS has not been used before in direct measurements of highly charged ions (HCI). Our new precision measurement of inner shell transitions in HCI is not just going to provide new x-ray standards for quantum metrology but can also give information about the plasma in which the ions reside. Ionic temperatures and with that the electron density can be determined by thorough examination of line widths measured with great accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shadow poles in the alternative parametrization of R-matrix theory

In this work, we discover new, hitherto unknown, shadow poles in Brune’s alternative parametrization of R-matrix theory [C. R. Brune, Phys. Rev. C 66, 044611 (2002)]. Where these poles are, and how many, depends on how one continues R-matrix operators to complex wavenumbers (specially the shift S and penetration P functions). This has little consequence for the exact R-matrix formalism (past the last energy threshold), as we show one can still always fully reconstruct the scattering matrix with only the previously known alternative parameters (poles and corresponding resonance widths), for which there were as many poles as the number of levels Nλ. However, we generalize the alternative parametrization to the Reich-Moore formalism, and show that the choice of continuation is now critical as it changes the alternative parameters values (poles and residue widths are now complex). In order to establish nuclear libraries with alternative parameters, the nuclear community will thus have to decide what convention to adopt. We argue in favor of analytical continuation (against the legacy Lane and Thomas approach) in a follow-up article [P. Ducru, Phys. Rev. C, submitted (2020)]. We observe the first evidence of shadow poles in the alternative parametrization of R-matrix theory in isotope xenon 134 Xe spin-parity group J π = 1=2 (–) , and show how they indeed depend on the choice of continuation to complex wavenumbers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of slot width on transition and noise attenuation of a flat sound shield in a Mach 6 wind tunnel

An experimental and theoretical study of a sound shield concept to attenuate the noise radiated into the test section from the turbulent boundary layer on the walls of wind tunnels was conducted. The model investigated was planar with a sharp flat plate leading edge faired into an array of rods aligned nearly parallel to the local flow. For a ratio of gap diameter to rod diameter of 0.16, the flow was laminar over the entire model at a maximum local length Reynolds number of 14 million. A 45% reduction in the tunnel free stream root mean square pressure level was measured within the shielded region for this gap width when the boundary layers on the rods were laminar. Smaller ratios of gap diameter to rod diameter resulted in substantial reductions in the transition Reynolds number, and in a 40% pressure reduction.

Stainback, P. C.↗

The EPED pedestal model and edge localized mode-suppressed regimes: Studies of quiescent H-mode and development of a model for edge localized mode suppression via resonant magnetic perturbations

The EPED model predicts the H-mode pedestal height and width based upon two fundamental and calculable constraints: (1) onset of non-local peeling-ballooning modes at low to intermediate mode number, (2) onset of nearly local kinetic ballooning modes at high mode number. We present detailed tests of the EPED model in discharges with edge localized modes (ELMs), employing new high resolution measurements, and finding good quantitative agreement across a range of parameters. The EPED model is then applied for the first time to quiescent H-mode (QH), finding a similar level of agreement between predicted and observed pedestal height and width, and suggesting that the model can be used to predict the critical density for QH-mode operation. Finally, the model is applied toward understanding the suppression of ELMs with 3D resonant magnetic perturbations (RMP). Combining EPED with plasma response physics, a new working model for RMP ELM suppression is developed. We propose that ELMs are suppressed when a 'wall' associated with the RMP blocks the inward penetration of the edge transport barrier. A calculation of the required location of this 'wall' with EPED is consistent with observed profile changes during RMP ELM suppression and offers an explanation for the observed dependence on safety factor (q{sub 95}).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analogue saturation limit of single and double 10 mm microchannel plate photomultiplier tubes

Photek are a well-established supplier of microchannel plate (MCP) photomultiplier tubes (PMTs) to the inertial confinement fusion community. The analogue signals produced at the major inertial confinement fusion facilities cover many orders of magnitude, therefore understanding the upper saturation limit of MCP-PMTs to large low rate signals takes on a high importance. Here we present a study of a single and a double MCP-PMT with 10 mm diameter active area. The saturation was studied for a range of optical pulse widths from 4 ns to 100 ns and at a range of electron gain values: 10{sup 3} to 10{sup 4} for the single and 10{sup 4} to 10{sup 6} for the double. We have shown that the saturation level of ∼1.2 nC depends only on the integrated charge of the pulse and is independent of pulse width and gain over this range, but that the level of charge available in deep saturation is proportional to the operating gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CFD-DEM solution verification: Fixed-bed studies

Fixed (frozen) particle configurations are used to study CFD-DEM convergence behavior in the limit of infinite grid resolution. A filtering scheme based on solving a diffusion equation, i.e., a Gaussian kernel, is used to interpolate particle information to the continuum grid, free of cell size limitations. A regression method is used for Richardson extrapolation of the discrete solutions to the grid-free solution. The regression method is shown to predict accurate extrapolation curves in the presence of the observed oscillatory convergence behavior. The extrapolation curve is used to complete the solution verification process by quantifying the numerical uncertainty present in the calculations. Several numerical and model parameters are studied including the spatial discretization method, the kernel width and the mean drag law. Here, a manageable level of discretization error is found with relative discretization errors generally <4%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-power pulsed thulium fiber oscillator modulated by stimulated Brillouin scattering

A pulsed ∼2-μm thulium-doped fiber laser passively modulated by distributed stimulated Brillouin scattering achieves 10.2 W average power and >100 kHz repetition rate with a very simple all-fiber configuration. The maximum pulse energy and peak power surpass 100 μJ and 6 kW, respectively. Another distinct property is that the pulse width is clamped around 17 ns at all power levels. All the average-power, pulse energy, and peak power show the highest values from passively modulated fiber lasers in all wavelength regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modulation instability of narrow-band nanosecond pulses propagating in anomalous-dispersion fibre

We demonstrate that, in the presence of noise, propagation of narrow-band 100-ns pulses through a 6-km long optical fibre sharply reduces their amplitude when a threshold power ({approx}0.2 W) is exceeded. The effect is due to the development of modulation instability and is sensitive to the noise level in the spectral region {approx}100 GHz in width around the central frequency. (fiber and integrated optics)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of SF{sub 6} and NF{sub 3} additives on UV and IR lasing in nitrogen

The lasing regimes of nitrogen laser on the C{sup 3{Pi}}{sub u} - B{sup 3{Pi}}{sub g} transition with a high-energy long laser pulse under pumping by a transverse discharge in N{sub 2} - SF{sub 6} (NF{sub 3}) mixtures from generators with a semiconductor opening switch is studied. Laser pulses with two peaks and controlled delay between these peaks are obtained. It is shown that the time interval between the peaks may exceed 50 ns for N{sub 2} - NF{sub 3} mixtures. The conditions for obtaining effective UV lasing with a laser pulse width of more than 50 ns at the base level are determined. A possibility of depopulating the lower level of the C{sup 3{Pi}}{sub u} - B{sup 3{Pi}}{sub g} transition by induced transitions in the first positive B{sup 3{Pi}}{sub g} - A{sup 3{Sigma}}{sub u}{sup +} system is shown; this process makes it possible to expand the pulse to 100 ns at {lambda} = 337.1 nm. The highest lasing energy and power in the IR and UV spectral ranges are obtained for nitrogen lasers with spark preionisation. (lasers)

74 ATOMIC AND MOLECULAR PHYSICS↗

MEASURING PROTOPLANETARY DISK ACCRETION WITH H I PFUND {beta}

In this work, we introduce the use of H I Pfund {beta} (Pf{beta}; 4.6538 {mu}m) as a tracer of mass accretion from protoplanetary disks onto young stars. Pf{beta} was serendipitously observed in NIRSPEC and CRIRES surveys of CO fundamental emission, amounting to a sample size of 120 young stars with detected Pf{beta} emission. Using a subsample of disks with previously measured accretion luminosities, we show that Pf{beta} line luminosity is well correlated with accretion luminosity over a range of at least three orders of magnitude. We use this correlation to derive accretion luminosities for all 120 targets, 65 of which are previously unreported in the literature. The conversion from accretion luminosity to accretion rate is limited by the availability of stellar mass and radius measurements; nevertheless, we also report accretion rates for 67 targets, 16 previously unmeasured. Our large sample size and our ability to probe high extinction values allow for relatively unbiased comparisons between different types of disks. We find that the transitional disks in our sample have lower than average Pf{beta} line luminosities, and thus accretion luminosities, at a marginally significant level. We also show that high Pf{beta} equivalent width is a signature of transitional disks with high inner disk gas/dust ratios. In contrast, we find that disks with signatures of slow disk winds have Pf{beta} luminosities comparable to those of other disks in our sample. Finally, we investigate accretion rates for stage I disks, including significantly embedded targets. We find that stage I and stage II disks have statistically indistinguishable Pf{beta} line luminosities, implying similar accretion rates, and that the accretion rates of stage I disks are too low to be consistent with quiescent accretion. Our results are instead consistent with both observational and theoretical evidence that stage I objects experience episodic, rather than quiescent, accretion.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINTS ON THE NEUTRON STAR AND INNER ACCRETION FLOW IN SERPENS X-1 USING NuSTAR

We report on an observation of the neutron star low-mass X-ray binary Serpens X-1, made with NuSTAR. The extraordinary sensitivity afforded by NuSTAR facilitated the detection of a clear, robust, relativistic Fe K emission line from the inner disk. A relativistic profile is required over a single Gaussian line from any charge state of Fe at the 5σ level of confidence, and any two Gaussians of equal width at the same confidence. The Compton back-scattering ''hump'' peaking in the 10-20 keV band is detected for the first time in a neutron star X-ray binary. Fits with relativistically blurred disk reflection models suggest that the disk likely extends close to the innermost stable circular orbit (ISCO) or stellar surface. The best-fit blurred reflection models constrain the gravitational redshift from the stellar surface to be z {sub NS} ≥ 0.16. The data are broadly compatible with the disk extending to the ISCO; in that case, z {sub NS} ≥ 0.22 and R {sub NS} ≤ 12.6 km (assuming M {sub NS} = 1.4 M {sub ☉} and a = 0, where a = cJ/GM {sup 2}). If the star is as large or larger than its ISCO, or if the effective reflecting disk leaks across the ISCO to the surface, the redshift constraints become measurements. We discuss our results in the context of efforts to measure fundamental properties of neutron stars, and models for accretion onto compact objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Unique signatures of the Rashba effect in the magneto-optical properties of two-dimensional semiconductors

Herein, the authors theoretically demonstrate two simple magneto-optical measurements which can be used to confirm the existence of Rashba terms in two dimensional semiconductors, even in samples of unoptimal quality, where the transition line widths are comparable to or larger than the Landau level splitting. The first is magnetic circular dichroism (MCD), where a giant MCD signal should be observed at the band edge in the presence of Rashba terms. The second is the comparison of the diamagnetic shift measured in absorption with that in photoluminescence which occurs from the dispersion minimum of the Rashba exciton.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

resbos2 and the CDF W mass measurement

The recent collider detector at fermilab (CDF) W mass measurement of 80 , 433 ± 9 MeV is the most precise direct measurement. However, this result deviates from the Standard Model predicted mass of 80 , 359.1 ± 5.2 MeV by 7 σ . The CDF experiment used an older version of the esos code that was only accurate at NNLL + NLO , while the esos2 code is able to make predictions at N 3 LL + NNLO accuracy. We determine that the data-driven techniques used by CDF capture most of the higher order corrections, and using higher order corrections would have an impact on the CDF result in total at the 10 MeV level. Additionally, we investigate the effects from handling the width of the W boson on the mass, PDF correlations, and scale uncertainties. We find that these contributions are consistent with those obtained by CDF. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Controlling the Phase-Space Volume of Injected Electrons in a Laser-Plasma Accelerator

To take full advantage of a laser-plasma accelerator, stability and control of the electron beam parameters have to be achieved. The external injection scheme with two colliding laser pulses is a way to stabilize the injection of electrons into the plasma wave, and to easily tune the energy of the output beam by changing the longitudinal position of the injection. In this Letter, it is shown that by tuning the optical injection parameters, one is able to control the phase-space volume of the injected particles, and thus the charge and the energy spread of the beam. With this method, the production of a laser accelerated electron beam of 10 pC at the 200 MeV level with a 1% relative energy spread at full width half maximum (3.1% rms) is demonstrated. This unique tunability extends the capability of laser-plasma accelerators and their applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-excitation technique for the measurement of absolute transition probabilities of weak atomic lines

A new technique is presented for the measurement of transition probabilities for weak allowed, intersystem, and forbidden lines. The method exploits the fact that oscillator strength is proportional to the number of stimulated absorptions and emissions produced by a narrow-band laser pulse of known energy which is in resonance with an atomic transition. The method is tested for a particular transition of Mg I with a known oscillator strength value and of appropriate magnitude. The number densities are measured using a Mach-Zehnder interferometer and the hook method for the lower level population and by measuring an absorption-equivalent width for the other. The apparatus consisted of a high-power tunable laser and a magnesium oven to produce excited Mg vapor, and a laser-plasma background continuum. The results are in good agreement with theoretical and other experimental data.

Kwong, H. S.↗

Low-Noise Supersonic Nozzle

Two-dimensional nozzle incorporates unusual design features of rapid expansion contour, boundary-layer bleed slots upstream of throat, and exit width-to-height ratio of 1.7 to provide noise levels in upstream regions of test rhombus substantially lower than in conventional nozzles.

Beckwith, I. E.↗

A Compact X-Ray System for Macromolecular Crystallography

We describe the design and performance of a high flux x-ray system for a macromolecular crystallography that combines a microfocus x-ray generator (40 micrometer full width at half maximum spot size at a power level of 46.5 W) and a collimating polycapillary optic. The Cu Ka lpha x-ray flux produced by this optimized system through a 500,um diam orifice is 7.0 times greater than the x-ray flux previously reported by Gubarev et al. [M. Gubarev et al., J. Appl. Crystallogr. 33, 882 (2000)]. The x-ray flux from the microfocus system is also 2.6 times higher than that produced by a rotating anode generator equipped with a graded multilayer monochromator (green optic, Osmic Inc. CMF24-48-Cu6) and 40% less than that produced by a rotating anode generator with the newest design of graded multilayer monochromator (blue optic, Osmic, Inc. CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 W, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42 540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym)=5.0% for data extending to 1.70 A, and 4.8% for the complete set of data to 1.85 A. The amplitudes of the observed reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

Gubarev, Mikhail↗

Nova V2362 Cygni (Nova Cygni 2006): Spitzer, Swift, and Ground-Based Spectral Evolution

Nova V2362 Cygni has undergone a number of very unusual changes. Ground-based spectroscopy initially revealed a normal sequence of events: the object faded and its near-infrared emission lines gradually shifted to higher excitation conditions until about day 100 when the optical fading reversed and the object slowly brightened. This was accompanied by a rise in the Swift X-ray telescope flux and a sudden shift in excitation of the visible and IR spectrum back to low levels. The new lower excitation spectrum revealed broad line widths and many P-Cygni profiles, all indicative of the ejection of a second shell. Eventually, dust formed, the X-ray brightness -- apparently unaffected by dust formation -- peaked and then declined, and the object faded at all wavelengths. The Spitzer dust spectra revealed a number of solid-state emission features that, at this time, are not identified.

Lynch, David K.↗