Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

HDice, Highly-Polarized Low-Background Frozen-Spin HD Targets for CLAS experiments at Jefferson Lab

Large, portable frozen-spin HD (Deuterium-Hydride) targets have been developed for studying nucleon spin properties with low backgrounds. Protons and Deuterons in HD are polarized at low temperatures (~10mK) inside a vertical dilution refrigerator (Oxford Kelvinox-1000) containing a high magnetic field (up to 17T). The targets reach a frozen-spin state within a few months, after which they can be cold transferred to an In-Beam Cryostat (IBC). The IBC, a thin-walled dilution refrigerator operating either horizontally or vertically, is use with quasi-4{pi} detector systems in open geometries with minimal energy loss for exiting reaction products in nucleon structure experiments. The first application of this advanced target system has been used for Spin Sum Rule experiments at the LEGS facility in Brookhaven National Laboratory. An improved target production and handling system has been developed at Jefferson Lab for experiments with the CEBAF Large Acceptance Spectrometer, CLAS.

43 PARTICLE ACCELERATORS↗

EM Calorimeters for SoLID at Jefferson Lab

Several approved experiments at Jefferson Lab for the 12 GeV era will use the proposed Solenoid Large Intensity Device (SoLID) spectrometer. Two EM calorimeters with a total area of 15 square meters are required for electron identification and electron-pion separation. The challenge is to build calorimeters that can withstand high radiation doses in high magnetic field region and bring photon signals to low field region for readout. Several types of calorimeters were considered and we are favoring Shashlyk type as a result of balancing performance and cost. Our preliminary design and simulation of SoLID EM calorimeters are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and performance of the electromagnetic calorimeters in Hall C at Jefferson Lab

The design and performance of the electromagnetic calorimeters in the magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers, construction information and comparisons of simulated and experimental results are presented. The design and simulated performance for a new calorimeter to be used in the new SHMS spectrometer is also presented. We have developed and constructed electromagnetic calorimeters from TF-1 type lead-glass blocks for the HMS and SOS magnetic spectrometers at JLab Hall C. The HMS/SOS calorimeters are of identical design and construction except for their total size. Blocks of dimension 10 cm × 10 cm × 70 cm are arranged in four planes and stacked 13 and 11 blocks high in the HMS and SOS respectively. The energy resolution of these calorimeters is better than 6%/√E, and pion/electron (π/e) separation of about 100:1 has been achieved in energy range 1–5 GeV. Good agreement has been observed between the experimental and GEANT4 simulated energy resolutions. The HMS/SOS calorimeters have been used nearly in all Hall C experiments, providing good energy resolution and a high pion suppression factor. No significant deterioration in their performance has been observed in the course of use since 1994. For the SHMS spectrometer, presently under construction, details on the calorimeter design and accompanying GEANT4 simulation efforts are given. A Preshower+Shower design was selected as the most cost-effective among several design choices. The preshower will consist of a layer of 28 modules with TF-1 type lead glass radiators, stacked in two columns. The shower part will consist of 224 modules with F-101 type lead glass radiators, stacked in a “fly's eye” configuration of 14 columns and 16 rows. The active area of 120 × 130 cm(2) will encompass the beam envelope at the calorimeter. The anticipated performance of the new calorimeter is simulated over the full momentum range of the SHMS, predicting resolution and yields similar to the HMS calorimeter. Good electron/hadron separation can be achieved by using energy deposition in the Preshower along with total energy deposition in the calorimeter. In this case the PID capability is similar to or better than that attainable with HMS calorimeter, with a pion suppression factor of a few hundreds predicted for 99% electron detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of a FIR Oscillator with Large Slippage parameter at Jefferson Lab for FIR/UV pump-probe experiments

We previously proposed a dual FEL configuration on the UV Demo FEL at Jefferson Lab that would allow simultaneous lasing at FIR and UV wavelengths. The FIR source would be an FEL oscillator with a short wiggler providing diffraction-limited pulses with pulse energy exceeding 50 microJoules, using the exhaust beam from a UVFEL as the input electron beam. Since the UV FEL requires very short pulses, the input to the FIR FEL is extremely short compared to a slippage length and the usual Slowly Varying Envelope Approximation (SVEA) does not apply. We use a non-SVEA code to simulate this system both with a small energy spread (UV laser off) and with large energy spread (UV laser on).

43 PARTICLE ACCELERATORS↗

Potential for a Tensor Asymmetry Azz Measurement in the x > 1 Region at Jefferson Lab

The tensor asymmetry A(zz) in the quasi-elastic region through the tensor polarized D(e, e')X channel is sensitive to the nucleon-nucleon potential. Previous measurements of A(zz) have been used to extract b(1) in the DIS region and T(20) in the elastic region. In the quasielastic region, A(zz) can be used to compare light cone calculations with variation nucleon- nucleon calculations, and is an important quantity to determine for understanding tensor effects, such as the dominance of pn correlations in nuclei. In the quasi-elastic region, A(zz) was first calculated in 1988 by Frankfurt and Strikman using the Hamada-Johnstone and Reid soft-core wave functions [1]. Recent calculations by M. Sargsian revisit A(zz) in the x > 1 range using virtual-nucleon and light-cone methods, which differ by up to a factor of two [2]. Discussed in these proceedings, a study has been completed that determines the feasibility of measuring A(zz) in the quasi-elastic x > 1 region at Jefferson Lab's Hall C.

Long, Elena↗

Fluorescence time profile measurement of LAB based liquid scintillator in response to medium relativistic ion particles

Liquid scintillator is widely used in particle physics experiments due to its high light yield, good timing resolution, scalability and low cost. Certain liquid scintillators exhibit pulse shape discrimination capabilities because of difference in fluorescence timing properties induced by different particles. Its fluoresence timing properties have been measured mostly for radioactive decay sources at MeV energies. Here, we present a novel measurement of fluorescence time properties of Linear Alkyl Benzene (LAB) based liquid scintillator in response to high-energy ions of hydrogen (Z = 1), helium (Z = 2) and krypton at around 200–300 MeV/u for the first time. We compared the results to those from radioactive sources and observed a distinct dE / dX dependence, regardless of the particle type. These findings are essential for physics searches such as the diffuse supernova neutrino background in large liquid scintillator detectors like JUNO, and are also critical towards understanding the underlying scintillation timing mechanism.

Ion identification systems↗

Cold compressor performance and energy consumption improvements at Jefferson Lab’s Central Helium Liquefiers

Abstract Jefferson Lab operates two central helium liquefiers (CHLs) which both utilize full cold compression from the saturation pressure at operating temperature (approximately 2.1 K) to just over atmospheric pressure. The original plant, CHL1, was recently outfitted with a replacement subatmospheric cold box (SC1R) containing state-of-the-art cold compressor technology, while the newer plant, CHL2, uses an older cold compressor system. In both cases, the heat of compression is absorbed at low temperature at the expense of electrical power consumed by the warm compressors. Due to the superior efficiency and turndown capabilities of SC1R, a new operating mode has been identified for CHL1 in which the required number of operating warm compressors is reduced by one. A cost-based method for optimizing cold compressor stability and efficiency has been developed and applied to CHL2, improving its turndown and lowering the warm compressor discharge pressure. As a result of these efforts, power consumption of the combined CHLs during normal operations has been reduced by nearly 10%, or a total of 650 kW. The observed performance of CHL1 with SC1R, as well as the cold compressor optimization method, leading to this improved energy consumption rate will be discussed in detail.

Mastracci, B [Thomas Jefferson National Accelerato↗

Measurement of the Ar ( e , e ' p ) and Ti ( e , e ' p ) cross sections in Jefferson Lab Hall A

The E12-14-012 experiment, performed in Jefferson Lab Hall A, has collected exclusive electron-scattering data ( e , e ' p ) in parallel kinematics using natural argon and natural titanium targets. In this study we report the first results of the analysis of the data set corresponding to beam energy 2222 GeV, electron scattering angle 21 . 5 ° , and proton emission angle – 50 ° . The differential cross sections, measured with ≈ 4 % uncertainty, have been studied as a function of missing energy and missing momentum, and compared to the results of Monte Carlo simulations, obtained from a model based on the distorted-wave impulse approximation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of deeply virtual Compton scattering off 4 He with the CEBAF Large Acceptance Spectrometer at Jefferson Lab

We report on the measurement of the beam spin asymmetry in the deeply virtual Compton scattering off $^4$He using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab using a 6 GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target. We detail the method used to ensure the exclusivity of the measured reactions, in particular the upgrade of CLAS with a radial time projection chamber to detect the low-energy recoiling $^4$He nuclei and an inner calorimeter to extend the photon detection acceptance at forward angles. Our results confirm the theoretically predicted enhancement of the coherent ($e^4$He$~\to~e'$$^4$He$'\gamma'$) beam spin asymmetries compared to those observed on the free proton, while the incoherent ($e^4$He$~\to~e'$p$'\gamma'$X$'$) asymmetries exhibit a 30$\%$ suppression. From the coherent data, we were able to extract, in a model-independent way, the real and imaginary parts of the only $^4$He Compton form factor, $\cal H_A$, leading the way toward 3D imaging of the partonic structure of nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elastic scattering in the 12 N + 197 Au system at 𝐸 lab = 70 MeV

Halo structure is an interesting exotic configuration developed in some light weakly bound nuclei, where a valence particle orbits a nuclear core. Signatures of halo structure can be observed in the angular distributions of the elastic scattering induced by these nuclei at energies around the Coulomb barrier. There are some well-studied reactions with neutron-rich halo nuclei, such as 6 He and 11 Li . However, the information is scarce on the proton-rich side. Recent works confirm the halo structure in the 8B nuclei but still lack more experimental studies for other proton-halo candidates, such as 12 N and 17 F. In this work, we report experimental data for the elastic scattering of 12 N on 197 Au target at 𝐸 lab = 70 MeV. The 12 N is a proton-rich nucleus with proton separation energy 𝑆 𝑝 = 600 keV, which is higher than the 8 B (𝑆 𝑝 = 137 keV) and almost the same as the 17 F (𝑆 𝑝 = 601 keV). Data were obtained at the Cyclotron Institute of Texas A&M University where the 12 N radioactive beam was produced by the momentum achromatic recoil spectrometer. The calculation of the optical model was used to fit the measured angular distribution for the elastic scattering and to obtain the reaction cross section 𝜎 𝑅 . We also performed continuum discretized coupled-channel calculations to compare with the experimental data. The angular distribution of the elastic cross sections exhibits a suppression of the Fresnel peak. From the fitting of the optical model, we obtain the total reaction cross section, 𝜎 𝑅 = 1269 ± 41 mb. The agreement between the CDCC calculation and the experimental elastic scattering data is limited and the breakdown does not exhaust the measured 𝜎 𝑅 . The resulting reduced reaction cross section 𝜎 Red for 12 N + 197 Au is large and comparable to the one obtained for the 8 B + 208 Pb system. This suggests a strong decoupling of the valence proton from the core because of the low binding energy and a dynamic polarization effect. Here, more research is required to estimate the contribution of core excitation.

Elastic scattering reactions↗

E00-110 experiment at Jefferson Lab Hall A: Deeply virtual Compton scattering off the proton at 6 GeV

We present final results on the photon electroproduction ($\vec{e}p\rightarrow ep\gamma$) cross section in the deeply virtual Compton scattering (DVCS) regime and the valence quark region from Jefferson Lab experiment E00-110. Results from an analysis of a subset of these data were published before, but the analysis has been improved which is described here at length, together with details on the experimental setup. Furthermore, additional data have been analyzed resulting in photon electroproduction cross sections at new kinematic settings, for a total of 588 experimental bins. Results of the $Q^2$- and $x_B$-dependences of both the helicity-dependent and helicity-independent cross sections are discussed. The $Q^2$-dependence illustrates the dominance of the twist-2 handbag amplitude in the kinematics of the experiment, as previously noted. Thanks to the excellent accuracy of this high luminosity experiment, it becomes clear that the unpolarized cross section shows a significant deviation from the Bethe-Heitler process in our kinematics, compatible with a large contribution from the leading twist-2 DVCS$^2$ term to the photon electroproduction cross section. The necessity to include higher-twist corrections in order to fully reproduce the shape of the data is also discussed. The DVCS cross sections in this study represent the final set of experimental results from E00-110, superseding the previous publication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First measurement of the Ti ( e , e ' ) X cross section at Jefferson Lab

To probe CP violation in the leptonic sector using GeV energy neutrino beams in current and future experiments using argon detectors, precise models of the complex underlying neutrino and antineutrino interactions are needed. The E12-14-012 experiment at Jefferson Lab Hall A was designed to perform a combined analysis of inclusive and exclusive electron scatterings on both argon (N = 22) and titanium (Z = 22) nuclei using GeV-energy electron beams. The measurement on titanium nucleus provides essential information to understand the neutrino scattering on argon, large contribution to which comes from scattering off neutrons. Here we report the first experimental study of electron-titanium scattering as double-differential cross section at beam energy E = 2.222 GeV and electron-scattering angle θ = 15.541°, measured over a broad range of energy transfer, spanning the kinematical regions in which quasielastic scattering and delta production are the dominant reaction mechanisms. In conclusion, the data provide valuable new information needed to develop accurate theoretical models of the electromagnetic and weak cross sections of these complex nuclei in the kinematic regime of interest to neutrino experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution hypernuclear spectroscopy at Jefferson Lab, Hall A

The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0 p -shell region of nuclei such as the hypernuclei produced in electroproduction on 9 Be, 12 C and 16 O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were added to the Hall A standard equipment. The high-quality beam, the good spectrometers and the new experimental devices allowed us to obtain very good results. Here, measurable strength with sub-MeV energy resolution was recorded for the core-excited states of $^{12}_{Λ}$B. A high-quality$^{16}_{Λ}N hypernuclear spectrum was likewise obtained. A first measurement of the Λ binding energy for Lambda 16N, calibrated against the elementary reaction on hydrogen, was obtained with high precision, 13.76 ± 0.16 MeV. Similarly, the first$^{9}_{Λ}Li hypernuclear spectrum shows general agreement with theory (distorted-wave impulse approximation with the SLA and BS3 electroproduction models and shell-model wave functions). Some disagreement exists with respect to the relative strength of the states making up the first multiplet. A Λ separation energy of 8.36 MeV was obtained, in agreement with previous results. It has been observed that the electroproduction of hypernuclei can provide information complementary to that obtained with hadronic probes and the γ-ray spectroscopy technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scaling behavior in exclusive meson photoproduction from Jefferson Lab at large momentum transfers

With the availability of new high-statistics and wide-angle measurements for several exclusive non-πN meson photoproduction channels from Jefferson Lab, we examine the fundamental scaling law of 90° scattering in QCD that was originally derived in the high-energy perturbative limit. The data show scaling to be prominently visible even in the medium-energy domain of 2.5 GeV ≲√s≲2.84 GeV, where √s is the center-of-mass energy. While constituent quark exchange suffices for pseudoscalar mesons, additional gluon exchanges from higher Fock states of the hadronic wave functions appear be needed for vector-meson production. Finally, the case of the Φ(1020), where two-gluon exchanges are known to dominate, is especially illuminating.

Dey, Biplab↗

Quantum Gravity in the Lab. I. Teleportation by Size and Traversable Wormholes

With the long-term goal of studying models of quantum gravity in the lab, we propose holographic teleportation protocols that can be readily executed in table-top experiments. These protocols exhibit similar behavior to that seen in the recent traversable-wormhole constructions of Gao et al. [J. High Energy Phys., 2017, 151 (2017)] and Maldacena et al. [Fortschr. Phys., 65, 1700034 (2017)]: information that is scrambled into one half of an entangled system will, following a weak coupling between the two halves, unscramble into the other half. We introduce the concept of teleportation by size to capture how the physics of operator-size growth naturally leads to information transmission. The transmission of a signal through a semiclassical holographic wormhole corresponds to a rather special property of the operator-size distribution that we call size winding. For more general systems (which may not have a clean emergent geometry), we argue that imperfect size winding is a generalization of the traversablewormhole phenomenon. In addition, a form of signaling continues to function at high temperature and at large times for generic chaotic systems, even though it does not correspond to a signal going through a geometrical wormhole but, rather, to an interference effect involving macroscopically different emergent geometries. Finally, we outline implementations that are feasible with current technology in two experimental platforms: Rydberg-atom arrays and trapped ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Generic Communication Protocol for Remote Laboratories: an Implementation on e-lab

The remote laboratories at IST (Instituto Superior Tecnico), e-lab, serve as a valuable tool for education and training based on remote control technologies. Due to the high number and increase of remotely operated experiments a generic protocol was developed to perform the communication between the software driver and the respective experimental setup in an easier and more unified way. The training in these fields of students and personnel can take advantage of such infrastructure with the purpose of deploying new experiments in a faster way. More than 10 experiments using the generic protocol are available on-line in a 24 x 7 way. (authors)

99 GENERAL AND MISCELLANEOUS↗

Projecting Solar Photovoltaic Efficiencies from Lab to Market

The future is uncertain and forecasting it is difficult. Yet to implement energy policies aimed at sustainable development, it is imperative to determine future energy scenarios. This requires forecasting the development of all relevant generation technologies, including the conversion efficiency of solar photovoltaics. Using historical data, a proven development formula and data on the lag between lab and market, efficiency projections up to 2050 are made for c-Si, CdTe, CIGS, 3- and 4 junction, perovskite, and quantum dot solar cells. The projected efficiencies of the first three, older technologies do not change significantly. The last four, newer technologies could make great leaps in efficiency and increase their market potential, if R&D efforts continue.

14 SOLAR ENERGY↗

Liquid nitrogen tests of a Torus coil for the Jefferson Lab 12GeV accelerator upgrade

A magnet system consisting of six superconducting trapezoidal racetrack-type coils is being built for the Jefferson Lab 12-GeV accelerator upgrade project. The magnet coils are wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. Each superconducting toroidal coil is force cooled by liquid helium, which circulates in a tube that is in good thermal contact with the inside of the coil. Thin copper sheets are soldered to the helium cooling tube and enclose the superconducting coil, providing cooling to the rest of the coil pack. As part of a rigorous risk mitigation exercise, each of the six coils is cooled with liquid nitrogen (LN2) to 80 K to validate predicted thermal stresses, verify the robustness and integrity of electrical insulation, and evaluate the efficacy of the employed conduction cooling method. This paper describes the test setup, the tests performed, and the findings.

Torus, SSC-NbTi, LN2 cold test, FEA, epoxy potting↗