Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “June 2010”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Assessment of marine boundary layer cloud simulations in the CAM with CLUBB and updated microphysics scheme based on ARM observations from the Azores

To assess marine boundary layer (MBL) cloud simulations in three versions of the Community Atmosphere Model (CAM), three sets of short-term global hindcasts are performed and compared to Atmospheric Radiation Measurement Program (ARM) observations on Graciosa Island in the Azores from June 2009 to December 2010. Here, the three versions consist of CAM5.3 with default schemes (CAM5.3), CAM5.3 with Cloud Layers Unified By Binormals (CLUBB-MG1), and CAM5.3 with CLUBB and updated microphysics scheme (CLUBB-MG2). Our results show that relative to CAM5.3 default schemes, simulations with CLUBB better represent MBL cloud base height, the height of the major cloud layer, and the daily cloud cover variability. CLUBB also better simulates the relationship of cloud fraction to cloud liquid water path (LWP) most likely due to CLUBB's consistent treatment of these variables through a probability distribution function (PDF) approach. Subcloud evaporation of precipitation is substantially enhanced in simulations with CLUBB-MG2 and is more realistic based on the limited observational estimate. Despite these improvements, all model versions underestimate MBL cloud cover. CLUBB-MG2 reduces biases in in-cloud LWP (clouds are not too bright) but there are still too few of MBL clouds due to an underestimate in the frequency of overcast scenes. Thus, combining CLUBB with MG2 scheme better simulates MBL cloud processes, but because biases remain in MBL cloud cover CLUBB-MG2 does not improve the simulation of the surface shortwave cloud radiative effect (CRE SW ).

54 ENVIRONMENTAL SCIENCES↗

Thermoelectric energy harvesting from diurnal heat flow in the upper soil layer

We built and tested a subterranean thermoelectric power source that converts diurnal heat flow through the upper soil layer into electricity. This paper describes the operation, design, and performance of the device. Key features of the power source include the use of bismuth-telluride thermopiles optimized for small ΔT and aerogel insulation to minimize thermal losses. The device weighs 0.24 kg and was designed with a flat form factor measuring 12 × 12 × 1.7 cm to facilitate modularity, packing, and assembly into larger arrays. One full year of field testing was performed between June 2009 and May 2010 in Albuquerque, New Mexico where the device generated an average power output of 1.1 mW. The season with the highest performance was spring (March–May) while the season of lowest performance was winter (November–January). During May 2010, the device generated an average power of 1.5 mW and a peak power of 9.8 mW at 9.3 V. Ten years of continuous operation at 1.1 mW would yield an energy density and specific energy of 1384 W h/L and 1430 W h/kg respectively, which is competitive with chemical batteries and is orders of magnitude greater than published subterranean and ambient thermoelectric harvesters. Numerical simulations show that performance is sensitive to the thermal properties of the soil and environmental conditions. This class of energy harvester may provide an option for supplemental power, or possibly primary power, for low power remote sensing applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prospective Study of Epidermal Growth Factor Receptor Tyrosine Kinase Inhibitors Concurrent With Individualized Radiotherapy for Patients With Locally Advanced or Metastatic Non-Small-Cell Lung Cancer

Purpose: To establish the safety profile and efficacy of epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs) concurrent with individualized radiotherapy (RT) in patients with locally advanced or metastatic non-small-cell lung cancer (NSCLC). Patients and Methods: Between June 2007 and January 2010, 26 patients with Stage III/IV NSCLC were enrolled in this prospective study. These patients were treated with EGFR-TKIs (gefitinib 250 mg or erlotinib 150 mg, oral daily) concurrent with individualized RT with curative intent. The thoracic RT plans were individually designed on the basis of tumor size and normal tissue volume constraints. All patients were assessed for toxicity, and 25 patients were available for efficacy. The primary endpoints were acute toxicity, overall survival, and median survival time. The secondary endpoints included local control rate, time to tumor progression, and progression-free survival (PFS). Results: Median gross tumor volume, mean lung dose, and lung V20 were 56 cm{sup 3}, 8.6 Gy, and 14%, respectively. Median thoracic radiation dose was 70 Gy at a margin of gross tumor volume (range, 42-82 Gy), and median biological equivalent dose was 105 Gy (range, 60-119 Gy). Acute skin, hematologic, esophageal, and pulmonary toxicities were acceptable and manageable. Severe adverse events included neutropenia (Grade 4, 4%) and thrombocytopenia (Grade 4, 8%), esophagitis (Grade 3, 4%), and pneumonitis (Grade 3, 4%). With a median follow-up of 10.2 months, a local control rate of 96% was achieved for thoracic tumor. Median time to progression, median PFS, and median survival time were 6.3, 10.2, and 21.8 months, respectively. The 1- and 2-year PFS rates were both 42%, and 1-, 2-, and 3-year overall survival rates were 57%, 45%, and 30%, respectively. Conclusion: Concurrent EGFR-TKIs with individualized RT shows a favorable safety profile and promising outcome, therefore serving as a therapeutic option for patients with locally advanced or metastatic NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consolidative Involved-Node Proton Therapy for Stage IA-IIIB Mediastinal Hodgkin Lymphoma: Preliminary Dosimetric Outcomes From a Phase II Study

Purpose: To compare the dose reduction to organs at risk (OARs) with proton therapy (PT) versus three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in patients with mediastinal Hodgkin lymphoma (HL) enrolled on a Phase II study of involved-node radiotherapy (INRT). Methods and Materials: Between June 2009 and October 2010, 10 patients were enrolled on a University of Florida institutional review board-approved protocol for de novo 'classical' Stage IA-IIIB HL with mediastinal (bulky or nonbulky) involvement after chemotherapy. INRT was planned per European Organization for Research and Treatment of Cancer guidelines. Three separate optimized plans were developed for each patient: 3D-CRT, IMRT, and PT. The primary end point was a 50% reduction in the body V4 with PT compared with 3D-CRT or IMRT. Results: The median relative reduction with PT in the primary end point, body V4, was 51% compared with 3D-CRT (p = 0.0098) and 59% compared with IMRT (p = 0.0020), thus all patients were offered treatment with PT. PT provided the lowest mean dose to the heart, lungs, and breasts for all 10 patients compared with either 3D-CRT or IMRT. The median difference in the OAR mean dose reduction with PT compared with 3D-CRT were 10.4 Gy/CGE for heart; 5.5 Gy/CGE for lung; 0.9 Gy/CGE for breast; 8.3 Gy/CGE for esophagus; and 4.1 Gy/CGE for thyroid. The median differences for mean OAR dose reduction for PT compared with IMRT were 4.3 Gy/CGE for heart, 3.1 Gy/CGE for lung, 1.4 Gy/CGE for breast, 2.8 Gy/CGE for esophagus, and 2.7 Gy/CGE for thyroid. Conclusions: All 10 patients benefitted from dose reductions to OARs with PT compared with either 3D-CRT or IMRT. It is anticipated that these reductions in dose to OAR will translate into lower rates of late complications, but long-term follow-up on this Phase II INRT study is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Salvage Stereotactic Reirradiation With or Without Cetuximab for Locally Recurrent Head-and-Neck Cancer: A Feasibility Study

Purpose: Normal tissues tolerance limits the use of reirradiation for recurrent head-and-neck cancers (HNC). Stereotactic body radiotherapy (SBRT) could offer precise irradiation while sparing healthy tissues. Results of a feasibility study using SBRT with or without cetuximab are reported for reirradiation of recurrent primary HNC. Methods and Materials: Patients with inoperable recurrent, or new primary tumor, in a previously irradiated area were included. Reirradiation dose was 36 Gy in six fractions of 6 Gy to the 85% isodose line covering 95% of the planning target volume. Patients with squamous cell carcinoma received concomitant cetuximab. Results: Between June 2007 and January 2010, 40 patients were prospectively treated for 43 lesions. Median age was 60 and median tumor size was 29 mm. Fifteen patients received concomitant cetuximab and 1 received concomitant cisplatin. Median follow-up was 25.6 months with 34 patients evaluable for tumor response. Median overall survival was 13.6 months and response rate was 79.4% (15 complete and 12 partial responses). Grade 3 toxicity occurred in 4 patients. Conclusion: These results suggest that short SBRT with or without cetuximab is an effective salvage treatment with good response rate in this poor prognosis population with previously irradiated HNC. Treatment is feasible and, with appropriate care to limiting critical structure, acute toxicities are acceptable. A prospective multicenter Phase II trial of SRT and concomitant cetuximab in recurrent HNC squamous cell carcinoma is ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective Dose Reduction to Cardiac Structures Using Protons Compared With 3DCRT and IMRT in Mediastinal Hodgkin Lymphoma

Purpose: We investigated the dosimetric impact of proton therapy (PT) on various cardiac subunits in patients with Hodgkin lymphoma (HL). Methods and Materials: From June 2009 through December 2010, 13 patients were enrolled on an institutional review board-approved protocol for consolidative involved-node radiotherapy (INRT) for HL. Three separate treatment plans were developed prospectively by using three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and PT. Cardiac subunits were retrospectively contoured on the 11 patients with intravenous-contrast simulation scans, and the doses were calculated for all treatment plans. A Wilcoxon paired test was performed to evaluate the statistical significance (p < 0.05) of 3DCRT and IMRT compared with PT. Results: The mean heart doses were 21 Gy, 12 Gy, and 8 Gy (relative biologic effectiveness [RBE]) with 3DCRT, IMRT, and PT, respectively. Compared with 3DCRT and IMRT, PT reduced the mean doses to the left and right atria; the left and right ventricles; the aortic, mitral, and tricuspid valves; and the left anterior descending, left circumflex, and right circumflex coronary arteries. Conclusions: Compared with 3DCRT and IMRT, PT reduced the radiation doses to all major cardiac subunits. Limiting the doses to these structures should translate into lower rates of cardiac toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Recurrence After Uveal Melanoma Proton Beam Therapy: Recurrence Types and Prognostic Consequences

Purpose: To study the prognosis of the different types of uveal melanoma recurrences treated by proton beam therapy (PBT). Methods and Materials: This retrospective study analyzed 61 cases of uveal melanoma local recurrences on a total of 1102 patients treated by PBT between June 1991 and December 2010. Survival rates have been determined by using Kaplan-Meier curves. Prognostic factors have been evaluated by using log-rank test or Cox model. Results: Our local recurrence rate was 6.1% at 5 years. These recurrences were divided into 25 patients with marginal recurrences, 18 global recurrences, 12 distant recurrences, and 6 extrascleral extensions. Five factors have been identified as statistically significant risk factors of local recurrence in the univariate analysis: large tumoral diameter, small tumoral volume, low ratio of tumoral volume over eyeball volume, iris root involvement, and safety margin inferior to 1 mm. In the local recurrence-free population, the overall survival rate was 68.7% at 10 years and the specific survival rate was 83.6% at 10 years. In the local recurrence population, the overall survival rate was 43.1% at 10 years and the specific survival rate was 55% at 10 years. The multivariate analysis of death risk factors has shown a better prognosis for marginal recurrences. Conclusion: Survival rate of marginal recurrences is superior to that of the other recurrences. The type of recurrence is a clinical prognostic value to take into account. The influence of local recurrence retreatment by proton beam therapy should be evaluated by novel studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety of {sup 90}Y Radioembolization in Patients Who Have Undergone Previous External Beam Radiation Therapy

Purpose: Previous external beam radiation therapy (EBRT) is theoretically contraindicated for yttrium-90 ({sup 90}Y) radioembolization (RE) because the liver has a lifetime tolerance to radiation before becoming vulnerable to radiation-induced liver disease. We analyzed the safety of RE as salvage treatment in patients who had previously undergone EBRT. Methods and Materials: Between June 2004 and December 2010, a total of 31 patients who had previously undergone EBRT were treated with RE. Three-dimensional treatment planning with dose–volume histogram (DVH) analysis of the liver was used to calculate the EBRT liver dose. Liver-related toxicities including RE-induced liver disease (REILD) were reviewed and classified according to Common Terminology Criteria for Adverse Events version 4.02. Results: The mean EBRT and RE liver doses were 4.40 Gy (range, 0-23.13 Gy) and 57.9 Gy (range, 27.0-125.9 Gy), respectively. Patients who experienced hepatotoxicity (≥grade2; n=12) had higher EBRT mean liver doses (7.96 ± 8.55 Gy vs 1.62 ± 3.39 Gy; P=.037), the only independent predictor in multivariate analysis. DVH analysis showed that the fraction of liver exposed to ≥30 Gy (V30) was the strongest predictor of hepatotoxicity (10.14% ± 12.75% vs 0.84% ± 3.24%; P=.006). All patients with V30 >13% experienced hepatotoxicity. Fatal REILD (n=2) occurred at the 2 highest EBRT mean liver doses (20.9 Gy and 23.1 Gy) but also at the highest cumulative liver doses (91.8 Gy and 149 Gy). Conclusions: Prior exposure of the liver to EBRT may lead to increased liver toxicity after RE treatment, depending on fractional liver exposure and dose level. The V30 was the strongest predictor of toxicity. RE appears to be safe for the treatment of hepatic malignancies only in patients who have had limited hepatic exposure to prior EBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Image-Guided IMRT in Advanced Pancreatic Cancer With Simultaneous Integrated Boost to Infiltrated Vessels Concomitant With Capecitabine: A Phase I Study

Purpose: To determine the maximum tolerated radiation dose (MTD) of an integrated boost to the tumor subvolume infiltrating vessels, delivered simultaneously with radical dose to the whole tumor and concomitant capecitabine in patients with pretreated advanced pancreatic adenocarcinoma. Methods and Materials: Patients with stage III or IV pancreatic adenocarcinoma without progressive disease after induction chemotherapy were eligible. Patients underwent simulated contrast-enhanced four-dimensional computed tomography and fluorodeoxyglucose-labeled positron emission tomography. Gross tumor volume 1 (GTV1), the tumor, and GTV2, the tumor subvolume 1 cm around the infiltrated vessels, were contoured. GTVs were fused to generate Internal Target Volume (ITV)1 and ITV2. Biological tumor volume (BTV) was fused with ITV1 to create the BTV+Internal Target Volume (ITV) 1. A margin of 5/5/7 mm (7 mm in cranium-caudal) was added to BTV+ITV1 and to ITV2 to create Planning Target Volume (PTV) 1 and PTV2, respectively. Radiation therapy was delivered with tomotherapy. PTV1 received a fixed dose of 44.25 Gy in 15 fractions, and PTV2 received a dose escalation from 48 to 58 Gy as simultaneous integrated boost (SIB) in consecutive groups of at least 3 patients. Concomitant chemotherapy was capecitabine, 1250 mg/m{sup 2} daily. Dose-limiting toxicity (DLT) was defined as any treatment-related G3 nonhematological or G4 hematological toxicity occurring during the treatment or within 90 days from its completion. Results: From June 2005 to February 2010, 25 patients were enrolled. The dose escalation on the SIB was stopped at 58 Gy without reaching the MTD. One patient in the 2{sup nd} dose level (50 Gy) had a DLT: G3 acute gastric ulcer. Three patients had G3 late adverse effects associated with gastric and/or duodenal mucosal damage. All patients received the planned dose of radiation. Conclusions: A dose of 44.25 Gy in 15 fractions to the whole tumor with an SIB of 58 Gy to small tumor subvolumes concomitant with capecitabine is feasible in chemotherapy-pretreated patients with advanced pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Evaluation of Acute Toxicity and Quality of Life After IMRT and Concurrent Chemotherapy for Anal Canal and Perianal Cancer

Purpose: A prospective cohort study was conducted to evaluate toxicity, quality of life (QOL), and clinical outcomes in patients treated with intensity modulated radiation therapy (IMRT) and concurrent chemotherapy for anal and perianal cancer. Methods and Materials: From June 2008 to November 2010, patients with anal or perianal cancer treated with IMRT were eligible. Radiation dose was 27 Gy in 15 fractions to 36 Gy in 20 fractions for elective targets and 45 Gy in 25 fractions to 63 Gy in 35 fractions for gross targets using standardized, institutional guidelines, with no planned treatment breaks. The chemotherapy regimen was 5-fluorouracil and mitomycin C. Toxicity was graded with the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. QOL was assessed with the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 and CR29 questionnaires. Correlations between dosimetric parameters and both physician-graded toxicities and patient-reported outcomes were evaluated by polyserial correlation. Results: Fifty-eight patients were enrolled. The median follow-up time was 34 months; the median age was 56 years; 52% of patients were female; and 19% were human immunodeficiency virus—positive. Stage I, II, III, and IV disease was found in 9%, 57%, 26%, and 9% of patients, respectively. Twenty-six patients (45%) required a treatment break because of acute toxicity, mainly dermatitis (23/26). Acute grade 3 + toxicities included skin 46%, hematologic 38%, gastrointestinal 9%, and genitourinary 0. The 2-year overall survival (OS), disease-free survival (DFS), colostomy-free survival (CFS), and cumulative locoregional failure (LRF) rates were 90%, 77%, 84%, and 16%, respectively. The global QOL/health status, skin, defecation, and pain scores were significantly worse at the end of treatment than at baseline, but they returned to baseline 3 months after treatment. Social functioning and appetite scores were significantly better at 12 months than at baseline. Multiple dose-volume parameters correlated moderately with diarrhea, skin, and hematologic toxicity scores. Conclusion: IMRT reduces acute grade 3 + hematologic and gastrointestinal toxicities compared with reports from non-IMRT series, without compromising locoregional control. The reported QOL scores most relevant to acute toxicities returned to baseline by 3 months after treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE ALLEN TELESCOPE ARRAY SEARCH FOR ELECTROSTATIC DISCHARGES ON MARS

The Allen Telescope Array was used to monitor Mars between 2010 March 9 and June 2, over a total of approximately 30 hr, for radio emission indicative of electrostatic discharge. The search was motivated by the report from Ruf et al. of the detection of non-thermal microwave radiation from Mars characterized by peaks in the power spectrum of the kurtosis, or kurtstrum, at 10 Hz, coinciding with a large dust storm event on 2006 June 8. For these observations, we developed a wideband signal processor at the Center for Astronomy Signal Processing and Electronics Research. This 1024 channel spectrometer calculates the accumulated power and power-squared, from which the spectral kurtosis is calculated post-observation. Variations in the kurtosis are indicative of non-Gaussianity in the signal, which can be used to detect variable cosmic signals as well as radio frequency interference (RFI). During the three-month period of observations, dust activity occurred on Mars in the form of small-scale dust storms; however, no signals indicating lightning discharge were detected. Frequent signals in the kurtstrum that contain spectral peaks with an approximate 10 Hz fundamental were seen at both 3.2 and 8.0 GHz, but were the result of narrowband RFI with harmonics spread over a broad frequency range.

79 ASTRONOMY AND ASTROPHYSICS↗

On the benefit of GOSAT observations to the estimation of regional CO2 fluxes

We assessed the utility of global CO{sub 2} distributions brought by the Greenhouse gases Observing SATellite (GOSAT) in the estimation of regional CO{sub 2} fluxes. We did so by estimating monthly fluxes and their uncertainty over a one-year period between June 2009 and May 2010 from (1) observational data collected in existing networks of surface CO2 measurement sites (GLOBALVIEWCO2 2010; extrapolated to the year 2010) and (2) both the surface observations and column-averaged dry air mole fractions of CO{sub 2} (X{sub CO2}) retrieved from GOSAT soundings. Monthly means of the surface observations and GOSAT X{sub CO2} retrievals gridded to 5{sup o} x 5{sup o} cells were used here. The estimation was performed for 64 subcontinental-scale regions. We compared these two sets of results in terms of change in uncertainty associated with the flux estimates. The rate of reduction in the flux uncertainty, which represents the degree to which the GOSAT X{sub CO2} retrievals contribute to constraining the fluxes, was evaluated. We found that the GOSAT X{sub CO2} retrievals could lower the flux uncertainty by as much as 48% (annual mean). Pronounced uncertainty reduction was found in the fluxes estimated for regions in Africa, South America, and Asia, where the sparsity of the surface monitoring sites is most evident.

54 ENVIRONMENTAL SCIENCES↗

Enhanced Performance Assessment System (EPAS) for carbon sequestration.

Carbon capture and sequestration (CCS) is an option to mitigate impacts of atmospheric carbon emission. Numerous factors are important in determining the overall effectiveness of long-term geologic storage of carbon, including leakage rates, volume of storage available, and system costs. Recent efforts have been made to apply an existing probabilistic performance assessment (PA) methodology developed for deep nuclear waste geologic repositories to evaluate the effectiveness of subsurface carbon storage (Viswanathan et al., 2008; Stauffer et al., 2009). However, to address the most pressing management, regulatory, and scientific concerns with subsurface carbon storage (CS), the existing PA methodology and tools must be enhanced and upgraded. For example, in the evaluation of a nuclear waste repository, a PA model is essentially a forward model that samples input parameters and runs multiple realizations to estimate future consequences and determine important parameters driving the system performance. In the CS evaluation, however, a PA model must be able to run both forward and inverse calculations to support optimization of CO{sub 2} injection and real-time site monitoring as an integral part of the system design and operation. The monitoring data must be continually fused into the PA model through model inversion and parameter estimation. Model calculations will in turn guide the design of optimal monitoring and carbon-injection strategies (e.g., in terms of monitoring techniques, locations, and time intervals). Under the support of Laboratory-Directed Research & Development (LDRD), a late-start LDRD project was initiated in June of Fiscal Year 2010 to explore the concept of an enhanced performance assessment system (EPAS) for carbon sequestration and storage. In spite of the tight time constraints, significant progress has been made on the project: (1) Following the general PA methodology, a preliminary Feature, Event, and Process (FEP) analysis was performed for a hypothetical CS system. Through this FEP analysis, relevant scenarios for CO{sub 2} release were defined. (2) A prototype of EPAS was developed by wrapping an existing multi-phase, multi-component reservoir simulator (TOUGH2) with an uncertainty quantification and optimization code (DAKOTA). (3) For demonstration, a probabilistic PA analysis was successfully performed for a hypothetical CS system based on an existing project in a brine-bearing sandstone. The work lays the foundation for the development of a new generation of PA tools for effective management of CS activities. At a top-level, the work supports energy security and climate change/adaptation by furthering the capability to effectively manage proposed carbon capture and sequestration activities (both research and development as well as operational), and it greatly enhances the technical capability to address this national problem. The next phase of the work will include (1) full capability demonstration of the EPAS, especially for data fusion, carbon storage system optimization, and process optimization of CO{sub 2} injection, and (2) application of the EPAS to actual carbon storage systems.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE S1 Bog Vegetation Allometric and Biomass Data: 2010-2011

This data set reports the results of measurements on sampled aboveground tissues of trees (Picea mariana and Larix laricina), shrubs (Ledum, Chamaedaphne, and Vaccinium), and ground layer vegetation (all species) of the S1 Bog located in areas adjacent to planned experimental study plots. Ground layer vegetation was sampled from both hummocks and hollows, within a 0.25 m2 plot, to evaluate total standing biomass of bog vegetation at or near the peak of annual production. Vegetation was harvested, processed, and measured in July of 2010 and again in June of 2011.

54 ENVIRONMENTAL SCIENCES↗

Split Active Asteroid P/2016 J1 (PANSTARRS)

We present a photometric and astrometric study of the split active asteroid P/2016 J1 (PANSTARRS). The two components (hereafter J1-A and J1-B) separated either ∼1500 days (2012 May to June) or 2300 days (2010 April) prior to the current epoch, with a separation speed V {sub sep} = 0.70 ± 0.02 m s{sup −1} for the former scenario and 0.83 ± 0.06 m s{sup −1} for the latter. Keck photometry reveals that the two fragments have similar, Sun-like colors that are comparable to the colors of primitive C- and G-type asteroids. With a nominal comet-like albedo, p{sub R} = 0.04, the effective, dust-contaminated cross sections are estimated to be 2.4 km{sup 2} for J1-A and 0.5 km{sup 2} for J1-B. We estimate that the nucleus radii lie in the range 140 ≲ R {sub N} ≲ 900 m for J1-A and 40 ≲ R {sub N} ≲ 400 m for J1-B. A syndyne–synchrone simulation shows that both components have been active for 3–6 months, by ejecting dust grains at speeds ∼0.5 m s{sup −1} with rates ∼1 kg s{sup −1} for J1-A and 0.1 kg s{sup −1} for J1-B. In its present orbit, the rotational spin-up and devolatilization times of 2016 J1 are very small compared to the age of the solar system, raising the question of why this object still exists. We suggest that ice that was formerly buried within this asteroid became exposed at the surface, perhaps via a small impact, and that sublimation torques then rapidly drove it to breakup. Further disintegration events are anticipated owing to the rotational instability.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Full Ice-cream Cone Model for Halo Coronal Mass Ejections

It is essential to determine three-dimensional parameters (e.g., radial speed, angular width, and source location) of coronal mass ejections (CMEs) for the space weather forecast. In this study, we investigate which cone type represents a halo CME morphology using 29 CMEs (12 Solar and Heliospheric Observatory (SOHO) /Large Angle and Spectrometric Coronagraph (LASCO) halo CMEs and 17 Solar Terrestrial Relations Observatory ( STEREO )/Sun–Earth Connection Coronal and Heliospheric Investigation COR2 halo CMEs) from 2010 December to 2011 June. These CMEs are identified as halo CMEs by one spacecraft ( SOHO or one of STEREO A and B ) and limb ones by the other spacecraft (One of STEREO A and B or SOHO ). From cone shape parameters of these CMEs, such as their front curvature, we find that the CME observational structures are much closer to a full ice-cream cone type than a shallow ice-cream cone type. Thus, we develop a full ice-cream cone model based on a new methodology that the full ice-cream cone consists of many flat cones with different heights and angular widths to estimate the three-dimensional parameters of the halo CMEs. This model is constructed by carrying out the following steps: (1) construct a cone for a given height and angular width, (2) project the cone onto the sky plane, (3) select points comprising the outer boundary, and (4) minimize the difference between the estimated projection speeds with the observed ones. By applying this model to 12 SOHO /LASCO halo CMEs, we find that 3D parameters from our method are similar to those from other stereoscopic methods (i.e., a triangulation method and a Graduated Cylindrical Shell model).

79 ASTRONOMY AND ASTROPHYSICS↗

Dependence of the Peak Fluxes of Solar Energetic Particles on CME 3D Parameters from STEREO and SOHO

We investigate the relationships between the peak fluxes of 18 solar energetic particle (SEP) events and associated coronal mass ejection (CME) 3D parameters (speed, angular width, and separation angle) obtained from SOHO , and STEREO-A / B for the period from 2010 August to 2013 June. We apply the STEREO CME Analysis Tool (StereoCAT) to the SEP-associated CMEs to obtain 3D speeds and 3D angular widths. The separation angles are determined as the longitudinal angles between flaring regions and magnetic footpoints of the spacecraft, which are calculated by the assumption of a Parker spiral field. The main results are as follows. (1) We find that the dependence of the SEP peak fluxes on CME 3D speed from multiple spacecraft is similar to that on CME 2D speed. (2) There is a positive correlation between SEP peak flux and 3D angular width from multiple spacecraft, which is much more evident than the relationship between SEP peak flux and 2D angular width. (3) There is a noticeable anti-correlation ( r = −0.62) between SEP peak flux and separation angle. (4) The multiple-regression method between SEP peak fluxes and CME 3D parameters shows that the longitudinal separation angle is the most important parameter, and the CME 3D speed is secondary on SEP peak flux.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetar Observations in the Swift-Fermi/GBM Era

NASA's Fermi Observatory was launched June 11, 2008; the Fermi Gamma Ray Burst Monitor (GBM) began normal operations on July 14, about a month after launch, when the trigger algorithms were enabled. Since then, and against all odds, GBM recorded over 600 bursts from 4 SGRs. Of these four sources, only one was an old magnetar: SGR J1806+20. SGR J0501+4516, was discovered with Swift and extensively monitored with GBM. A source originally classified as AXP 1E1547.0-5408 exhibited SGR-like bursting behavior and we reclassified it as SGR J1550-5418. Finally, GBM discovered SGR J0418+5729 on 2009 June. Finally, on March 2010, a third new magnetar was discovered with Swift, SGR J1833-0832. I report below on the current status of the field and on several results combining multi-satellite and ground-based data

Kouveliotou, Chryssa↗