High-Precision Zinc Isotopic Measurement of Certified Reference Materials Relevant to the Environmental, Earth, Planetary and Biomedical Sciences

The zinc (Zn) stable isotope system has emerged as a powerful tool for investigating natural and anthropogenic processes of interest to disciplines extending from the Earth and planetary sciences to biomedical research. In nature, Zn isotopes typically fractionate ( 66 Zn/ 64 Zn) within the range of –1 and +1 permil (‰), and however, analytical limitations restrict the application of the Zn isotope system. Specifically, there is a lack of well-characterised matrix-matched reference materials covering most Zn isotope applications that are essential for validating laboratory performance, particularly given the contamination prone nature of Zn. Furthermore, the increasing demand for analysis of size-limited materials and sample types displaying small, sub-permil level Zn isotope variations requires improvements in measurement procedures. To address these limitations, the δ 66 Zn values of two pure Zn solutions and eighteen reference materials including the previously uncharacterised RGM-2, BCR-279, DOLT-4, DOLT-5, NASS-7, SBC-1, SGR-1b, MESS-3 and HISS-1, and the understudied QLO-1, SDC-1, BCR-414, NASS-6 and COQ-1 materials are reported. Furthermore, a 70 Zn- 67 Zn double-spike design has been implemented that routinely achieves intermediate measurement precision better than ± 0.02‰. This represents at least a two-fold improvement when compared with other double-spike designs, providing a robust platform of δ 66 Zn values required for quality control procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon isotope evidence for the global physiology of Proterozoic cyanobacteria

Ancestral cyanobacteria are assumed to be prominent primary producers after the Great Oxidation Event [≈2.4 to 2.0 billion years (Ga) ago], but carbon isotope fractionation by extant marine cyanobacteria (α-cyanobacteria) is inconsistent with isotopic records of carbon fixation by primary producers in the mid-Proterozoic eon (1.8 to 1.0 Ga ago). To resolve this disagreement, we quantified carbon isotope fractionation by a wild-type planktic β-cyanobacterium (Synechococcus sp. PCC 7002), an engineered Proterozoic analog lacking a CO 2 -concentrating mechanism, and cyanobacterial mats. At mid-Proterozoic pH and pCO 2 values, carbon isotope fractionation by the wild-type β-cyanobacterium is fully consistent with the Proterozoic carbon isotope record, suggesting that cyanobacteria with CO 2 -concentrating mechanisms were apparently the major primary producers in the pelagic Proterozoic ocean, despite atmospheric CO 2 levels up to 100 times modern. The selectively permeable microcompartments central to cyanobacterial CO 2 -concentrating mechanisms (“carboxysomes”) likely emerged to shield rubisco from O 2 during the Great Oxidation Event.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement Error and Resolution in Quantitative Stable Isotope Probing: Implications for Experimental Design

Quantitative stable isotope probing (qSIP) estimates isotope tracer incorporation into DNA of individual microbes and can link microbial biodiversity and biogeochemistry in complex communities. As with any quantitative estimation technique, qSIP involves measurement error, and a fuller understanding of error, precision, and statistical power benefits qSIP experimental design and data interpretation. We used several qSIP data sets—from soil and seawater microbiomes—to evaluate how variance in isotope incorporation estimates depends on organism abundance and resolution of the density fractionation scheme. We assessed statistical power for replicated qSIP studies, plus sensitivity and specificity for unreplicated designs. As a taxon’s abundance increases, the variance of its weighted mean density declines. Nine fractions appear to be a reasonable trade-off between cost and precision for most qSIP applications. Increasing the number of density fractions beyond that reduces variance, although the magnitude of this benefit declines with additional fractions. Our analysis suggests that, if a taxon has an isotope enrichment of 10 atom% excess, there is a 60% chance that this will be detected as significantly different from zero (with alpha 0.1). With five replicates, isotope enrichment of 5 atom% could be detected with power (0.6) and alpha (0.1). Finally, we illustrate the importance of internal standards, which can help to calibrate per sample conversions of %GC to mean weighted density. These results should benefit researchers designing future SIP experiments and provide a useful reference for metagenomic SIP applications where both financial and computational limitations constrain experimental scope.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical Kinetics of Stable Isotopes (Final Report)

Stable isotopes are sensitive indicators to the mass transport and chemical reactions that occur during potentiostat-controlled electroplating of metals from aqueous (and some non-aqueous) metal-salt solutions. The goal of this research program is to measure the stable isotope fractionation during electrochemical processes, how the isotope-dependent rates are sensitive to chemistry, temperature, and electrochemical kinetics, and to use these measurements to develop a theoretical framework for a kinetic isotope effect that is able to predict kinetic isotope fractionation factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fitting $\overline{ν}$ for Minor Pu Isotopes

After successful fitting of prompt ν for 235 U, 238 U, and 239 Pu(n,f) using CGMF, we have moved on to the minor plutonium isotopes. Minor isotopes pose a greater challenge both because there is less data available and we do not, by default, have parametrizations in CGMF already. Initially, we had planned to mitigate these challenges—and provide consistency within CGMF—by taking a stepped approach to the optimization. Continuing from the 239 Pu work, we would then fit 241Pu(n,f) $\overline{ν}$, where there is also a number of experimental measurements, keeping consistency between the parameters that are included in the calculation for 239 Pu and 241 Pu. With these parametrizations settled, we could consistently optimize 240 Pu(n,f) $\overline{ν}$. Following that step, we would move on to 242 Pu(n,f) (and increasing neutron number) and 238 Pu(n,f) (and decreasing neutron number). By including the fissioning systems in this manner, we should be able to minimize the unknown parameters in CGMF. We were also able to develop systematics for the CGMF input parameters along the Pu isotopic chain. However, after studies in the beginning of FY23, where we found reasonable agreement between CGMF and experimental prompt neutron multiplicities for 238−242 Pu, using a compound mass dependent parametrization from, and from discussions with I. Stetcu and P. Talou, we instead performed the evaluation of all five isotopes simultaneously. For all parameters in CGMF, they are either the same for each compound nucleus, or have a dependence on the compound mass. The details of these updates are given in. This report builds upon those details. In this short report, we first give an example of how we have updated CGMF to include 240 Pu(n,f) and 242 Pu(n,f), keeping consistency with the current 239 Pu and 241 Pu calculations, but without rigorous optimization (Sec. 2). Then, we will show in Section 3 what experimental data exist for the various isotopes to provide some insight into why 241 Pu and 239 Pu are used as anchor points. The evaluation is detailed in Section 4, and the comparison between CGMF calculations using the evaluated parameters and other prompt observables besides average neutron multiplicity are discussed in Section 2.2. Finally, we present conclusions and future work in Section 5.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams

Online monitoring is a key challenge for the continued development of molten salt reactor (MSR) technology. Laser-induced breakdown spectroscopy (LIBS) has previously been demonstrated to be a viable tool for monitoring aerosolized species and noble gases in real time, but the ability to discern varying isotopes in these streams has not yet been investigated for MSR applications. Tritium will form in MSRs from ternary fission and from (n,α)-reactions occurring in lithium-containing salts. This study compares three spectrometers of varying resolutions and types for measuring hydrogen isotope shifts in LIBS spectra of wetted filter paper. For each spectrometer, multivariate models were built (i.e., principal component regression, partial least squares regression, and multivariate curve resolution) to quantify the isotope ratio. The top models were then modified and corrected to apply the models to aerosol samples with varying isotope ratios. This novel calibration strategy offers an 82% reduction in volume of the calibration samples needed and is a more viable pathway for calibrating deployable LIBS systems. Lastly, this calibration model was compared with an all-aerosol trained model for monitoring hydrogen isotopes during a real-time test where the protium/deuterium ratio, along with representative salt species (i.e., lithium, sodium, and potassium) were adjusted dynamically. Results of this test validated the predictive capabilities of the transferred model and highlighted the capabilities of LIBS for real-time monitoring of MSR effluent streams.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

CAPE-K_ISO: Water vapor isotopic measurements from Western Tasmania

This dataset provides processed 1-minute water vapor isotope observations from the Water Vapor Isotopic Measurements During CAPE-K project at the Kennaook/Cape Grim Baseline Air Pollution Station in northwestern Tasmania. Measurements were made with a Picarro L-2130 cavity ring-down spectroscopy analyzer during the CAPE-K deployment. The dataset includes water vapor mixing ratio, d18O, dD, deuterium excess, and propagated 1-sigma uncertainties. Isotope ratios are calibrated to the VSMOW/SLAP scale. Calibration intervals, transition periods, and obvious isotope outliers have been removed. The processed record spans 11 June 2024 to 15 October 2025 and is intended for studies of Southern Ocean marine boundary-layer moisture, isotope variability, air-sea exchange, and cloud and precipitation processes.

Water Vapor Isotopic Composition↗

Experimental investigation of elemental and isotopic evaporation processes by laser heating in an aerodynamic levitation furnace

In this report we carried out evaporation experiments on a B-type calcium–aluminium-rich inclusion (CAI) melt in a gas-mixing aerodynamic levitation laser furnace, at 1873 K and an oxygen partial pressure of 10 -9.1 atm, for durations ranging from 60 to 600 s. Evaporation of SiO 2 and MgO follow the same trend as those observed in vacuum furnace experiments at the same temperature and starting composition, showing that their evaporation relative to one another from the melt is independent of pressure, oxygen fugacity, and hydrodynamical regime specific to the furnace. Isotopic ratios of Mg and Si in evaporation residues are used to derive fractionation factors of α 26/24 Mg vap-liq = 0.9906± 0.0004 and α 30/28 Si vap-lip = 0.9943±0.0003, which are both significantly closer to unity than those found for evaporation in a vacuum, which translates to less isotope fractionation. The residues are also less isotopically fractionated than expected for cases in which transport of the gas species away from the melt is diffusion-controlled at 1-atm. By analysing the flow regimes in our furnace, we find that advection by the levitating gas is the primary mode of mass transport away from the melt surface, as opposed to diffusion-limited transport in a vacuum or 1-atm tube furnace. A modified Hertz–Knudsen–Langmuir formulation accounts for this process, and shows that isotopic fractionation of both Si and Mg reflect a saturation factor (ratio of the pressure of the evaporating species to vapour saturation pressure) equal to 0.75. This is in perfect accord with recent measurements of Cu isotopic fractionation using a similar furnace. The fact that three elements (Mg, Si, Cu) with varying equilibrium vapour pressures, activity coefficients in the liquid, and diffusion coefficients in the gas have the same scaling behaviour to saturation pressure is a strong indication that the mechanism controlling evaporation is driven by the hydrodynamical regime imposed in the furnace. Therefore, this class of experiments can be used to constrain processes in which advection dominates over diffusion, such as (but not limited to) planetary ejecta, tektites, giant impacts, nebular condensation in a turbulent flow, or nuclear fallout material. Finally, the possibility to reach high temperatures (in excess of 3500 K) in this furnace allows it to be used to evaluate the activity coefficients of melt components in extreme conditions relevant to molten planetary interiors (i.e., magma oceans), with a specific focus on refractory elements.

58 GEOSCIENCES↗

Iron isotope evidence of an impact origin for main-group pallasites

Despite decades of work, the origin of pallasite meteorites has remained enigmatic. Long thought to be samples of the core-mantle boundary of differentiated asteroids, more recent studies have suggested a range of mechanisms for pallasite formation. These include olivine-metal mixing during a planetesimal collision and the intrusion of over-pressured core liquids into a planetesimal mantle. Establishing if the olivine and metal that comprise pallasites were once equilibrated at high temperature remains key to discriminating between these hypotheses. We determined the iron isotope compositions of olivine and metal in eleven main-group pallasites and found, in all cases, that olivine is isotopically lighter than metal. To interpret these data, we constrained the olivine-metal equilibrium Fe isotope fractionation with ab initio calculations and high temperature experiments. These independent approaches show that olivine preferentially incorporates the heavy isotopes of iron relative to metal. Our results demonstrate that pallasitic olivine and metal never achieved isotopic equilibrium with respect to iron. This precludes extended cooling at high temperature and is best reconciled with an impact origin for the main-group pallasites.

58 GEOSCIENCES↗

Isotope effects associated with the anaerobic oxidation of sulfite and thiosulfate by the photosynthetic bacterium, Chromatium vinosum

The purple photosynthetic bacterium Chromatium vinosum, strain D, catalyzes several oxidations of reduced sulfur compounds under anaerobic conditions in the light: e.g., sulfide --> sulfur --> sulfate, sulfite --> sulfate, and thiosulfate --> sulfur + sulfate. Here it is shown that no sulfur isotope effect is associated with the last of these processes; isotopic compositions of the sulfur and sulfate produced can differ, however, if the sulfane and sulfonate positions within the thiosulfate have different isotopic compositions. In the second process, an observed change from an inverse to a normal isotope effect during oxidation of sulfite may indicate the operation of 2 enzymatic pathways. In contrast to heterotrophic anaerobic reduction of oxidized sulfur compounds, anaerobic oxidations of inorganic sulfur compounds by photosynthetic bacteria are characterized by relatively small isotope effects.

Non-NASA Center↗

Natural abundances of carbon isotopes in acetate from a coastal marine sediment

Measurements of the natural abundances of carbon isotopes were made in acetate samples isolated from the anoxic marine sediment of Cape Lookout Bight, North Carolina. The typical value of the total acetate carbon isotope ratio (delta 13C) was -16.1 +/- 0.2 per mil. The methyl and carboxyl groups were determined to be -26.4 +/- 0.3 and -6.0 +/- 0.3 per mil, respectively, for one sample. The isotopic composition of the acetate is thought to have resulted from isotopic discriminations that occurred during the cycling of that molecule. Measurements of this type, which have not been made previously in the natural environment, may provide information about the dominant microbial pathways in anoxic sediments as well as the processes that influence the carbon isotopic composition of biogenic methane from many sources.

NASA Discipline Exobiology↗

Carbon isotope effects associated with aceticlastic methanogenesis

The carbon isotope effects associated with synthesis of methane from acetate have been determined for Methanosarcina barkeri 227 and for methanogenic archaea in sediments of Wintergreen Lake, Michigan. At 37 degrees C, the 13C isotope effect for the reaction acetate (methyl carbon) --> methane, as measured in replicate experiments with M. barkeri, was - 21.3% +/- 0.3%. The isotope effect at the carboxyl portion of acetate was essentially equal, indicating participation of both positions in the rate-determining step, as expected for reactions catalyzed by carbon monoxide dehydrogenase. A similar isotope effect, - 19.2% +/- 0.3% was found for this reaction in the natural community (temperature = 20 degrees C). Given these observations, it has been possible to model the flow of carbon to methane within lake sediment communities and to account for carbon isotope compositions of evolving methane. Extension of the model allows interpretation of seasonal fluctuations in 13C contents of methane in other systems.

NASA Discipline Exobiology↗

Origin of magnetite in oxidized CV chondrites: in situ measurement of oxygen isotope compositions of Allende magnetite and olivine

Magnetite in the oxidized CV chondrite Allende mainly occurs as spherical nodules in porphyritic-olivine (PO) chondrules, where it is associated with Ni-rich metal and/or sulfides. To help constrain the origin of the magnetite, we measured oxygen isotopic compositions of magnetite and coexisting olivine grains in PO chondrules of Allende by an in situ ion microprobe technique. Five magnetite nodules form a relatively tight cluster in oxygen isotopic composition with delta 18O values from -4.8 to -7.1% and delta 17O values from -2.9 to -6.3%. Seven coexisting olivine grains have oxygen isotopic compositions from -0.9 to -6.3% in delta 18O and from -4.6 to -7.9% in delta 17O. The delta 17O values of the magnetite and coexisting olivine do not overlap; they range from -0.4 to -2.6%, and from -4.0 to -5.7%, respectively. Thus, the magnetite is not in isotopic equilibrium with the olivine in PO chondrules, implying that it formed after the chondrule formation. The delta 17O of the magnetite is somewhat more negative than estimates for the ambient solar nebula gas. We infer that the magnetite formed on the parent asteroid by oxidation of metal by H2O which had previously experienced minor O isotope exchange with fine-grained silicates.

Iron/analysis/chemistry↗

Martian stable isotopes: volatile evolution, climate change and exobiological implications

Measurements of the ratios of stable isotopes in the martian atmosphere and crust provide fundamental information about the evolution of the martian volatile and climate system. Current best estimates of the isotope ratios indicate that there has been substantial loss of gases to space and exchange of gases between the atmosphere and the crust throughout geologic time; exchange may have occurred through circulation of water in hydrothermal systems. Processes of volatile evolution and exchange will fractionate the isotopes in a manner that complicates the possible interpretation of isotopic data in terms of any fractionation that may have been caused by martian biota, and must be understood first. Key measurements are suggested that will enhance our understanding of the non-biological fractionation of the isotopes and of the evolution of the martian volatile system.

Review, Tutorial↗

Alteration of the Carbon and Nitrogen Isotopic Composition in the Martian Surface Rocks Due to Cosmic Ray Exposure

C-13/C-12 and N-15/N-14 isotopic ratios are pivotal for our understanding of the Martian carbon cycle, history of the Martian atmospheric escape, and origin of the organic compounds on Mars. Here we demonstrate that the carbon and nitrogen isotopic composition of the surface rocks on Mars can be significantly altered by the continuous exposure of Martian surface to cosmic rays. Cosmic rays can effectively produce C-13 and N-15 isotopes via spallation nuclear reactions on oxygen atoms in various Martian rocks. We calculate that in the top meter of the Martian rocks, the rates of production of both C-13 and N-15 due to galactic cosmic rays (GCRs) exposure can vary within 1.5-6 atoms/cm3/s depending on rocks' depth and chemical composition. We also find that the average solar cosmic rays can produce carbon and nitrogen isotopes at a rate comparable to GCRs in the top 5-10 cm of the Martian rocks. We demonstrate that if the total carbon content in a surface Martian rock is <10 ppm, then the "light," potentially "biological" C-13/C-12 ratio would be effectively erased by cosmic rays over 3.5 billion years of exposure. We found that for the rocks with relatively short exposure ages (e.g., 100 million years), cosmogenic changes in N-15/N-14 ratio are still very significant. We also show that a short exposure to cosmic rays of Allan Hills 84001 while on Mars can explain its high-temperature heavy nitrogen isotopic composition (N-15/N-14). Applications to Martian meteorites and the current Mars Science Laboratory mission are discussed.

cosmic ray exposure↗

Ag isotopic and chalcophile element evolution of the terrestrial and martian mantles during accretion: new constraints from Bi, Pd, and Ag metal-silicate partitioning.

The Earth’s timing of accretion and acquisition of moderately volatile compounds is uncertain. Hafnium-W and Mn-Cr isotopic data can bracket the timing of early planetary differentiation and core formation. The Ag-Pd system has also been utilized but its application has been limited by a lack of high pressure and temperature metal-silicate partitioning for Pd and Ag. Be-cause Ag (and Bi) are volatile chalcophile siderophile elements, understanding their early distribution can constrain the origin of volatile elements in differentiated bodies and planets. Unfortunately, neither Ag or Bi have been studied across the wide range of pressure and temperature conditions that are relevant to accretion and core-mantle differentiation. Here, new high-pressure and temperature multi-anvil metal-silicate equilibrium experiments for Bi and Ag have been carried out at conditions relevant to planetary accretion and metal silicate differentiation that allow a more refined and complete understanding of element partitioning during core formation. The new metal-silicate partitioning data utilized to predict the distributions of Bi, Pd, and Ag at conditions of accretion for Earth and Mars and show that the Pd/Ag ratio is significantly fractionated during accretion, allowing for the production of detectable 107Ag anomalies produced while 107Pd (half life = 6.5 M.y.) was still extant. Application of the new partitioning results to Earth shows that D(Bi) and D(Ag) (D = metal/silicate concentration ratio) are lowered due to the effect of pressure and Si alloyed in the metallic liquid, resulting in higher predicted mantle Bi and Ag abundances than in the bulk silicate Earth (BSE), as well as high and variable Pd/Ag. The unradiogenic Ag isotopic composition of the BSE could have been generated by early accretion of volatile-poor (high Pd/Ag) precursors, followed by later accretion of volatile–rich (low Pd/Ag) material, in agreement with earlier studies of Pd-Ag and Mn-Cr (Schönbächler et al., 2010). However, these main accretion phases would have to be followed by segregation of a sulfide liquid (at least 1.5% of magma ocean) at high pressures (>30 GPa), to explain the PUM Bi, Pd, and Ag, as well as Au, Pt, Cu and Ni concentrations as proposed previously. If the early accreted bulk Earth was volatile depleted with high Pd/Ag ratios, portions of the mantle may contain ancient domains that developed positive 107Ag isotopic anomalies (as also argued by noble gases, Nd, W, and Os isotopes). In comparison, Bi, Pd, and Ag concentrations in the martian mantle could have been set by simple metal-silicate equilibrium. Mars accreted and differentiated relatively rapidly, while also developing a deep magma ocean with a high Pd/Ag ratio that could have evolved positive 107Ag anomalies, in contrast to Earth. Measurements on shergottites may reveal these predicted Ag isotopic anomalies.

accretion↗

Cerium Stable Isotope Analysis of Synthetic and Terrestrial Rock Reference Materials by MC-ICPMS

Cerium is the most abundant rare earth element (REE) in the solar photosphere, CI chondrites, and the Earth. It has four main stable isotopes (masses: 136,138,140, and 142), with 138Ce being the most studied species, used in geochronology and petrogenesis. In addition, more abundant 140Ce and 142Ce are suggested to be potentially applicable in geochemical investigations. In this work, we developed a modified four-step ion chromatography procedure for Ce chemical separation. Using a MC-ICPMS, we designed a cup configuration to measure 142Ce/140Ce ratio of the samples with an optimized Nd correction equation. A 0.03‰ (2SD) reproducibility was obtained for Ce Ames metal standard. We analyzed ten different igneous and one sedimentary geochemical reference materials. Mean δ142Ce range from −0.07 to 0.32‰. Most of the samples show a heavier Ce isotopic composition than the Ce Ames standard. The majority of rocks have a homogenous δ142Ce. The δ142Ce does not show any correlation with rock chemical composition including their Ce content or rock types. A carbonatite (SARM 40) has a mean δ142Ce of −0.07 ± 0.13‰ (2SD), lower than the other rocks, suggesting the possibility of a pronounced isotopic fractionation. Our work demonstrates the applicability of the developed methodology and the potential of Ce stable isotopes for future geochemical studies. Production of a larger database of δ142Ce values is required to obtain a clearer view on the similarities and differences between different geological material and explaining Ce stable isotope dynamics.