Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Critical issues in the formation of quantum computer test structures by ion implantation

The formation of quantum computer test structures in silicon by ion implantation enables the characterization of spin readout mechanisms with ensembles of dopant atoms and the development of single atom devices. We briefly review recent results in the characterization of spin dependent transport and single ion doping and then discuss the diffusion and segregation behaviour of phosphorus, antimony and bismuth ions from low fluence, low energy implantations as characterized through depth profiling by secondary ion mass spectrometry (SIMS). Both phosphorus and bismuth are found to segregate to the SiO2/Si interface during activation anneals, while antimony diffusion is found to be minimal. An effect of the ion charge state on the range of antimony ions, 121Sb25+, in SiO2/Si is also discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ion gyroradius effects on particle trapping in kinetic Alfven waves along auroral field lines

In this study, a 2-D self-consistent hybrid gyrofluid-kinetic electron model is used to investigate Alfven wave propagation along dipolar magnetic field lines for a range of ion to electron temperature ratios. The focus of the investigation is on understanding the role of these effects on electron trapping in kinetic Alfven waves sourced in the plasma sheet and the role of this trapping in contributing to the overall electron energization at the ionosphere. This work also builds on our previous effort by considering a similar system in the limit of fixed initial parallel current, rather than fixed initial perpendicular electric field. It is found that the effects of particle trapping are strongest in the cold ion limit and the kinetic Alfven wave is able to carry trapped electrons a large distance along the field line yielding a relatively large net energization of the trapped electron population as the phase speed of the wave is increased. However, as the ion temperature is increased, the ability of the kinetic Alfven wave to carry and energize trapped electrons is reduced by more significant wave energy dispersion perpendicular to the ambient magnetic field which reduces the amplitude of the wave. This reduction of wave amplitude in turn reduces both the parallel current and the extent of the high-energy tails evident in the energized electron populations at the ionospheric boundary (which may serve to explain the limited extent of the broadband electron energization seen in observations). Here, even in the cold ion limit, trapping effects in kinetic Alfven waves lead to only modest electron energization for the parameters considered (on the order of tens of eV) and the primary energization of electrons to keV levels coincides with the arrival of the wave at the ionospheric boundary.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A fitting algorithm for optimizing ion implantation energies and fluences

In this work we describe a method to automatically generate an ion implantation recipe, a set of energies and fluences, to produce a desired defect density profile in a solid using the fewest required energies. We simulate defect density profiles for a range of ion energies, fit them with an appropriate function, and interpolate to yield defect density profiles at arbitrary ion energies. Given Ν energies, we then optimize a set of Ν energy-fluence pairs to match a given target defect density profile. Finally, we find the minimum Ν such that the error between the target defect density profile and the defect density profile generated by the Ν energy-fluence pairs is less than a given threshold. Inspired by quantum sensing applications with nitrogen-vacancy centers in diamond, we apply our technique to calculate optimal ion implantation recipes to create uniform-density 1 μm surface layers of 15 N or vacancies (using 4 He).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal annealing behavior of hydrogen and surface topography of H 2 + ion implanted tungsten

Tungsten (W) has been proposed as a plasma-facing material (PFM) in fusion reactors due to its outstanding properties. Degradation of the material properties is expected to occur as a result of hydrogen (H) isotope permeation and trapping in W. In this study, two polycrystalline W plates were implanted with 80 keV H 2 + ions to a fluence of 2E21 H+/m2 at room temperature (RT). Time-of-flight secondary ion mass spectrometry (ToF-SIMS), focused ion beam (FIB) and scanning electron microscopy (SEM) were used for sample characterization. The SIMS data shows that H atoms are distributed well beyond the ion projected range. Isochronal annealing appears to suggest two H release stages that might be associated with the reported activation energies. H release at RT was observed between days 10 and 70 following ion implantation, and the level was maintained over the next 60 days. In addition, FIB/SEM results exhibit H2 blister formation near the surface of the as-implanted W. The blister distribution remains unchanged after thermal annealing up to 600 °C.

H diffusion and release↗

Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30–250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm{sup 2} were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm{sup 2} area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam direction. A strong distortion in Bragg peak measurement was observed, confirming manufacturer recommendation on avoiding such configuration. Very good results were obtained for SOBP measurements, with a difference below 1% between measured and TPS-calculated doses. The stability of detector sensitivity in the observation period was within the experimental uncertainty. Conclusions: Dosimetric characterization of a PTW microDiamond detector in high-energy scanned carbon ion beams was performed. The results of the present study showed that this detector is suitable for dosimetry of clinical carbon ion beams, with a negligible LET and dose-rate dependence.

07 ISOTOPE AND RADIATION SOURCES↗

The ionosphere of Uranus - A myriad of possibilities

A one-dimensional model has been used to study the effects of exospheric temperature, methane and water influx, ionospheric outflow, and electron precipitation on the composition and structure of the ionosphere of Uranus. Peak ion concentrations range from 1000 to 1 million per cu cm with a wide variation in peak altitude, which depends strongly on the exospheric temperature. In all the cases considered, H(+) is the major ion in the topside ionosphere. At altitudes near or below the peak, H3(+) and CH5(+) can dominate, depending on the magnitude of CH4 and H2O influx. Atomic hydrogen column depths above the methane absorbing layer exceed 10 to the 17th per sq cm and can produce large (400 R) emissions of resonantly scattered Lyman-alpha. In the sunlit polar cap, electron precipitation with energy fluxes of 0.6 to 1.0 erg/sq cm s results in direct production of Lyman-alpha emissions that exceed 1 kR.

Chandler, M. O.↗

Quantifying the mechanical effects of He, W and He + W ion irradiation on tungsten with spherical nanoindentation

Here, recent advances in spherical nanoindentation protocols have proven very useful for capturing the grain-scale mechanical response of different metals. This is achieved by converting the load–displacement response into an effective indentation stress–strain response which reveals latent information such as the elastic–plastic transition or indentation yield strength and work-hardening behavior and subsequently correlating the response with the material structure (e.g., crystal orientation) at the indentation site. Using these protocols, we systematically study and quantify the microscale mechanical effects of He, W, and He + W ion irradiation on commercially pure, polycrystalline tungsten. The indentation stress–strain response is correlated with the crystal orientation from electron backscatter diffraction, the defect structure from transmission electron microscopy micrographs, and the stopping range of ions in matter calculations of displacement damage and He concentration. He-implanted grains show a much higher indentation yield strength and saturation stress compared to W-ion-irradiated grains for the same displacement damage. There is also good agreement between the dispersed barrier hardening model with a barrier strength of 0.5–0.8 and void models (Bacon–Kochs–Scattergood and Osetsky–Bacon models) with the experimentally observed changes in indentation strength due to the presence of He bubbles. This finding indicates that a high density (~ 9 × 10 23 m –3 ) and concentration (~ 1.5 at.%) of small (~ 1 nm diameter) He bubbles can be moderate to strong barriers to dislocation slip in tungsten.

36 MATERIALS SCIENCE↗

Rarefactive and compressive soliton waves in unmagnetized dusty plasma with non-thermal electron and ion distribution

Sagdeev's pseudo potential method is employed to study dust acoustic solitary waves in an unmagnetized plasma containing negatively charged dusts with non-thermal electron and ion. The range of parameters for the existence of solitary waves using the analytical expression of the Sagdeev potential has been found. It is observed that, depending on the values of the plasma parameters like ion to electron temperature ratio σ, non-thermal parameters β and γ, electron to ion density ratio μ, and the value of the Mach number M, both rarefactive and compressive solitary waves may exist.

36 MATERIALS SCIENCE↗

Fast ion generation and bulk plasma heating with three-ion ICRF scenarios

Launching electromagnetic waves in the ion cyclotron range of frequencies (ICRF) is an efficient method of plasma heating, actively employed in most of fusion machines. ICRF has a number of important supplementary applications, including the generation of high-energy ions. In this paper, we discuss a new set of three-ion ICRF scenarios and the prospect of their use as a dedicated tool for fast ion generation in tokamaks and stellarators. A distinct feature of these scenarios is a strong absorption efficiency possible at very low concentrations of resonant minority ions (∼ 1% or even below). Such concentration levels are typical for impurities contaminating fusion plasmas. An alternative ICRF scenario for maximizing the efficiency of bulk D-T ion heating is suggested for JET and ITER tokamaks, which is based on three-ion ICRF heating of intrinsic Beryllium impurities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-46: Development of a Compton Camera Prototype for Online Range Verification of Laser-Accelerated Proton Beams

Purpose: Development of a photon detection system designed for online range verification of laser-accelerated proton beams via prompt-gamma imaging of nuclear reactions. Methods: We develop a Compton camera for the position-sensitive detection of prompt photons emitted from nuclear reactions between the proton beam and biological samples. The detector is designed to be capable to reconstruct the photon source origin not only from the Compton scattering kinematics of the primary photon, but also to allow for tracking of the Compton-scattered electrons. Results: Simulation studies resulted in the design of the Compton camera based on a LaBr{sub 3}(Ce) scintillation crystal acting as absorber, preceded by a stacked array of 6 double-sided silicon strip detectors as scatterers. From the design simulations, an angular resolution of ≤ 2° and an image reconstruction efficiency of 10{sup −3} −10{sup −5} (at 2–6 MeV) can be expected. The LaBr{sub 3} crystal has been characterized with calibration sources, resulting in a time resolution of 273 ps (FWHM) and an energy resolution of about 3.8% (FWHM). Using a collimated (1 mm diameter) {sup 137}Cs calibration source, the light distribution was measured for each of 64 pixels (6×6 mm{sup 2}). Data were also taken with 0.5 mm collimation and 0.5 mm step size to generate a reference library of light distributions that allows for reconstructing the interaction position of the initial photon using a k-nearest neighbor (k-NN) algorithm developed by the Delft group. Conclusion: The Compton-camera approach for prompt-gamma detection offers promising perspectives for ion beam range verification. A Compton camera prototype is presently being developed and characterized in Garching. Furthermore, an arrangement of, e.g., 4 camera modules could even be used in a ‘gamma-PET’ mode to detect delayed annihilation radiation from positron emitters in the irradiation interrupts (with improved performance in the presence of an additional third (prompt) photon (as in 10C and 14O). This work was supported by the DFG Cluster of Excellence MAP (Munich-Centre for Advanced Photonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new center for heavy ion research

Progress in cancer therapy with ions heavier than protons, i.e., helium, carbon, oxygen and neon, requires research and development capability. Ion research activity, however, is limited from the absence of U.S. accelerator facilities offering ion beams for therapy – placing the U.S. significantly behind Europe and Asia. With dramatic advances in beam delivery and compact accelerators, the potential exists to create a facility that can play a leadership role in particle therapy and ion-based research. This paper announces summary details of a new center for ion therapy research under construction in Waco, TX, in collaboration with recognized accelerator entities both academic and industrial. The advanced accelerator technologies will produce beams for both clinical and research applications, offering a complete range of ions, intensities and energies required by the medical community, including the capability to perform ultra-high dose irradiation (FLASH) research. FLASH, a recent research initiative, which has the potential of reducing cancer treatment toxicities, is an important if not critical capability for a competitive research center – requiring beam intensities well beyond those provided by current medical accelerators. Building a state-of-the-art cancer research center within a comprehensive facility will provide the resources to promote ion therapy in the U.S, including, preclinical/clinical trials and protocols between modalities, and also support broad ion R&D.

43 PARTICLE ACCELERATORS↗

Some aspects of simulation and realization of an optical reference cavity

The interrogation of an ultranarrow clock transition of a single trapped ion for optical frequency metrology requires a laser stabilized to a couple of Hz per second with a linewidth of the same order of magnitude. Today, lasers in the visible have reached the Hz-range in frequency stability, if locked onto a high-finesse, ultrastable reference cavity. Vertical mounting of the reference cavity can reduce its sensitivity to vibrations as described in [M. Notcutt, L. Ma, J. Ye, and J. Hall, Opt. Lett. 30, 1815 (2005)]. We have designed a comparable vertical cavity with an overall length of 150 mm resulting in a free spectral range of 1 GHz. Optimization of the cavity design has been carried out with a finite elements method, leading to expected relative length variations below 10{sup -14} under the influence of gravity acceleration (1g). The variation in different geometric parameters has been studied. The analysis of the different noise sources shows that, for a regime superior to a tenth of a hertz, the fast linewidth of the laser will not be limited by the cavity characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theory for charge states of energetic oxygen ions in the earth's radiation belts

Fluxes of geomagnetically trapped energetic oxygen ions have been studied in detail. Ion distributions in radial locations below the geostationary orbit, energy spectra between 1 keV and 100 MeV, and the distribution over charge states have been computed for equatorially mirroring ions. Both ionospheric and solar wind oxygen ion sources have been considered, and it is found that the charge state distributions in the interior of the radiation belts are largely independent of the charge state characteristics of the sources. In the MeV range, oxygen ions prove to be a more sensitive probe for radiation belt dynamics than helium ions and protons.

Spjeldvik, W. N.↗

Effect of Ti-Al cathode composition on plasma generation and plasma transport in direct current vacuum arc

DC arc plasma from Ti, Al, and Ti{sub 1-x}Al{sub x} (x = 0.16, 0.25, 0.50, and 0.70) compound cathodes was characterized with respect to plasma chemistry and charge-state-resolved ion energy. Scanning electron microscopy, X-ray diffraction, and Energy-dispersive X-ray spectroscopy of the deposited films and the cathode surfaces were used for exploring the correlation between cathode-, plasma-, and film composition. Experimental work was performed at a base pressure of 10{sup −6} Torr, to exclude plasma-gas interaction. The plasma ion composition showed a reduction of Al of approximately 5 at. % compared to the cathode composition, while deposited films were in accordance with the cathode stoichiometry. This may be explained by presence of neutrals in the plasma/vapour phase. The average ion charge states (Ti = 2.2, Al = 1.65) were consistent with reference data for elemental cathodes, and approximately independent on the cathode composition. On the contrary, the width of the ion energy distributions (IEDs) were drastically reduced when comparing the elemental Ti and Al cathodes with Ti{sub 0.5}Al{sub 0.5}, going from ∼150 and ∼175 eV to ∼100 and ∼75 eV for Ti and Al ions, respectively. This may be explained by a reduction in electron temperature, commonly associated with the high energy tail of the IED. The average Ti and Al ion energies ranged between ∼50 and ∼61 eV, and ∼30 and ∼50 eV, respectively, for different cathode compositions. The attained energy trends were explained by the velocity rule for compound cathodes, which states that the most likely velocities of ions of different mass are equal. Hence, compared to elemental cathodes, the faster Al ions will be decelerated, and the slower Ti ions will be accelerated when originating from compound cathodes. The intensity of the macroparticle generation and thickness of the deposited films were also found to be dependent on the cathode composition. The presented results may be of importance for choice of cathodes for thin film depositions involving compound cathodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Zr Ion Implantation on Surface Mechanical Properties and Corrosion Resistance of Pure Magnesium

Zirconium (Zr) was implanted into pure Mg by metal vapor vacuum arc (MEVVA) at the dose of 2 × 10{sup 16} ions/cm{sup 2} at room temperature. The surface characteristics of Zr-implanted Mg were analyzed by the Stopping and Range of Ions in Matter software (SRIM) and x-ray photoelectron spectroscopy (XPS), the surface nanohardness and tribological behavior were measured through nanoindentation and a friction-abrasion testing machine, and the corrosion resistance of Zr-implanted Mg was evaluated by electrochemical measurement and immersion test in simulated body fluid (SBF). The results demonstrated that a gradient modified layer composed of MgO, Mg(OH){sub 2}, ZrO{sub 2} and Zr was formed on the near surface of pure Mg and the nanohardness of pure Mg was improved by 48%. Furthermore, the Zr-implanted Mg exhibited a more positive corrosion potential of − 1.43 V (versus SCE) and a lower corrosion current density of 19.9 μA/cm{sup 2}, and localized corrosion was effectively retarded during 24 h immersion in SBF, suggesting that the corrosion resistance of pure Mg was remarkably improved after Zr ion implantation. The mechanisms of surface strengthening and improved corrosion resistance were also discussed in this paper.

36 MATERIALS SCIENCE↗

Effect of fast positive ions incident on caesiated plasma grid of negative ion source

This paper describes the effect on negative ion formation on a caesiated surface of the backscattering of positive ions approaching it with energy of a few tens of eV. For a positive ion energy of 45 eV, the surface produced negative ion current density due to these fast positive ions is 12 times larger than that due to thermal atoms, thus dominating the negative ion surface production instead of the thermal atoms, as considered until now.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energetic Neutral Atom Imaging at Low Altitudes from the Swedish Microsatellite Astrid: Images and Spectral Analysis

Observations of energetic neutral atoms (ENA) in the energy range 26- 52 keV are reported from four occasions during geomagnetically disturbed periods. The data were acquired by the ENA imager flown on the Swedish microsatellite Astrid in a 1000 km circular orbit with 83 deg inclination. The ENA imager separates charged particles from neutrals through an electrostatic deflection system in the energy range between 0.1 and 114 keV. ENA images obtained from vantage points in the polar cap and in the afternoon magnetic local time (MLT) hours looking into the antisunward hemisphere show intense ENA fluxes (approx. 10(exp 4)/sq cm sr s over 26-37 keV) coming from the dusk region and low altitudes (approx. 300 km). The morphology shows no relation to local magnetic field excluding the possibility of charged particle detection. It is concluded that the source of these ENAs are precipitating/mirroring ions from the ring current/trapped radiation interacting with the exobase on auroral L-shells and in the dusk region. The observed ENA fluxes show a relation with Kp and Dst geomagnetic indices. The observed ENA spectrum from a geomagnetic storm on February 8, 1995, is investigated in more detail and compared to the parent ion spectrum obtained by the Defense Meteorological Satellite Project (DMSP) satellite, Fl2, during the same period on L = 6 +/- 2 around dusk. The observed ENA spectral slope is used to derive the parent ion spectral temperature. The derived ion temperatures range is 3.0 - 6.0 keV for H and 4.5 - 8.5 keV for O. The higher of these ion temperatures comes closest in agreement to the extrapolated DMSP spectrum leading us to favor O over H as the species of the detected ENAS. It is shown that the detected ENAs must have been produced at L greater than or equal to 6 to reach the detector without atmospheric attenuation and that the main energy dependence of the ENA spectrum, apart from the parent ion spectrum, is governed by the energy dependence of the charge exchange cross section between ions and exospheric oxygen.

Brandt, Pontus C:son↗

Radiation behavior of high-entropy alloys for advanced reactors. Final report

In the first task, we have demonstrated the radiation damage and the recrystallization behaviors in multicomponent alloys through molecular-dynamics simulations. It is found that by alloying with atoms of different sizes, the atomic-level strain increases, and the propensity of the radiation-induced crystalline to amorphous transition increases as the defects cluster in the cascade body. Recrystallization of the radiation induced supercooled or glass regions show that by tuning the composition and the equilibrium temperature, the multicomponent alloys can be healed. The crystalline-amorphous-crystalline transitions predict the potential high radiation resistance in multicomponent alloys. In the second task, three types of high-entropy alloys (HEAs) were fabricated from AlCoCrFeNi and AlCuCrFeNi quinary alloys. Hardness and reduced contact modulus were measured using nanoindentation tests. Heavy ion irradiation were performed using 10 MeV gold and 5 MeV nickel to study radiation effects. Al 0.5 CrCuFeNi 2 shows phase separation upon the presence of copper. Both hardness and contact modulus exhibit the same trend as increasing the applied load, and it indicates that excessive free volume may alter the growth rate of the plastic zone. The as-cast Al 0.1 CoCrFeNi specimen undergone the hot isostatic pressing (HIP) process and steady cooling rate which mitigate the quenching effect. The swelling behavior was characterized by the atomic force microscopy (AFM), and the swelling rate is approximately 0.02% dpa. Selected area diffraction (SAD) patters show irradiation-induced amorphization throughout the ion projected range. Within the peak damage region, an amorpous ring is observed, and a mixture of amorphous/ crystalline structure at deeper depth is found. The Al 0.3 CoCrFeNi HEAs shows good radiation resistance up to 60 peak dpa. No voids or dislocations are observed. The crystal structures remain face-centered-cubic (FCC) before and after 5 MeV Ni irradiation. Higher dpa might be required to study defects formation mechanisms. In the third task, all the constituent binary and ternary systems of the Al-Co-Cr-Fe-Ni system were thermodynamically modeled within the whole composition range. Comparisons between the calculated phase diagrams and literature data are in good agreement. The multi-component thermodynamic database of the Al-Co-Cr-Fe-Ni system was then obtained via extrapolation. The current Al-Co-Cr-Fe-Ni thermodynamic database enables us to carry out the calculations of phase diagrams, which can be used as useful guidelines to identify the Al-Co-Cr-Fe-Ni HEAs with desirable microstructures. In the fourth task, we discuss how as-cast and homogenized phases can be identified, what phases are usually found in the as-cast and homogenized conditions, and what the thermodynamics and kinetics of phase transformations are in the AlCoCrFeNi HEA. The microstructure and phase composition were studied in as-cast and homogenized conditions. It showed the dendritrical structure in the as-cast condition consisting primarily of a nano-lamellar mixture of A2 [disorder body-centered-cubic (BCC)] and B2 (ordered BCC) phases, in addition to a very small amount of A1 [disorder face-centered-cubic (FCC)] phases. The homogenization heat treatment resulted in an increase in the volume fraction of the A1 phase and formation of a Sigma phase. Tensile properties in as-cast and homogenized conditions are reported at 700 °C. Thermodynamic modeling of non-equilibrium and equilibrium phase diagrams for the AlCoCrFeNi HEA gave good agreement with the experimental observations of the phase contents. The reasons for the improvement of ductility after the heat treatment are discussed.

36 MATERIALS SCIENCE↗