Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation Set Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

OCI Geolocation Evaluation and Refinement Using Landsat Control Points

The Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission is NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer, Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. The geolocation processing is performed for OCI using spacecraft navigation data and an instrument geometry model. To evaluate the geolocation accuracy for OCI and develop refinements to the processing methods, control point matching using Landsat data has been implemented as a step in the operational processing of OCI data at the Science Data Segment. This processing provides between 200 and 300 high-quality matchups per day with good global and geometric distribution, allowing rapid evaluation of the OCI geolocation accuracy. The results provided an early indication of the overall quality of the geolocation processing and of specific aspects needing improvement. A standard set of granules was identified to support rapid implementation and testing of geolocation refinements, and this approach has been highly successful in improving the geolocation processing accuracy to meet the science requirements. The evaluation will continue throughout the mission to ensure the ongoing accuracy of geolocation. This paper describes the control point matching methodology, the approach to development of the geolocation processing refinements, and the recent results.

PACE↗

Beam optics and the pp2pp experiment at RHIC

The newly installed forward detector system at the STAR experiment at RHIC measures small angle elastic and inelastic scattering of polarized protons on polarized protons. The detector system makes use of a pair of Roman Pot (RP) detectors, instrumented with silicon detectors, and located on either side of the STAR intersection region downstream of the DX and D0 dipoles and quadrupole triplets. The parallel to point optics is designed so that scattering angles are determined from position measurements at the RP's with small error. The RP setup allows measurement of position and angle for a subset of the scattered protons. With this position/angle correlations at the RP's can be compared with optics model predictions to get a measure of the accuracy of the quadrupole triplet current settings. The current in each quadrupole in the triplets is comprised of sums and differences of up to six power supplies and an overall 1% error in the triplet field strengths results in a 4% error in four-momentum transfer squared. This technique is also useful to check the polarity of the skew elements located in each quadrupole triplet. Results of the analysis will be presented.

43 PARTICLE ACCELERATORS↗

Experimental search for solar hidden photons in the eV energy range using kinetic mixing with photons

We have searched for solar hidden photons in the eV energy range using a dedicated hidden photon detector. The detector consisted of a parabolic mirror with a diameter of 500 mm and a focal length of 1007 mm installed in a vacuum chamber, and a photomultiplier tube at its focal point. The detector was attached to the Tokyo axion helioscope, Sumico which has a mechanism to track the sun. From the result of the measurement, we found no evidence for the existence of hidden photons and set a limit on the photon-hidden photon mixing parameter χ depending on the hidden photon mass m{sub γ'}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Synthescope: A Vision for Combining Synthesis with Atomic Fabrication

Here, the scanning transmission electron microscope, a workhorse instrument in materials characterization, is being transformed into an atomic-scale material-manipulation platform. With an eye on the trajectory of recent developments and the obstacles toward progress in this field, a vision for a path toward an expanded set of capabilities and applications is provided. The microscope is reconceptualized as an instrument for fabrication and synthesis with the capability to image and characterize atomic-scale structural formation as it occurs. Further development and refinement of this approach may have substantial impact on research in microelectronics, quantum information science, and catalysis, where precise control over atomic-scale structure and chemistry of a few “active sites” can have a dramatic impact on larger-scale functionality and where developing a better understanding of atomic-scale processes can help point the way to larger-scale synthesis approaches.

36 MATERIALS SCIENCE↗

Design of machine learning models with domain experts for automated sensor selection for energy fault detection

Data-driven techniques that extract insights from sensor data reduce the cost of improving system energy performance through fault detection and system health monitoring. To lower cost barriers to widespread deployment, a methodology is proposed that takes advantage of existing sensor data, encodes expert knowledge about the application system to create ‘virtual sensors’ and applies statistical and mathematical methods to reduce the time required for manual configurations. The approach combines sensor data points with encoded expert knowledge that is generic to the application system but independent of a particular deployment, thereby reducing the need to tailor to individual deployments. Additionally, this paper not only presents a method that detects faults from measured energy data, but also (1) describes an engagement method with experts in the energy system domain to identify data, (2) integrates domain knowledge with the data, (3) automatically selects from among the large pool of potential input data, and (4) uses machine learning to automatically build a data-driven fault detection model. Demonstration on a commercial building chiller plant shows that only a small number of virtual sensors is necessary for fault detection with high accuracy rates. This corresponds to the use of only five out of 52 original sensor data points features. With as few as four features, classification F1 scores exceed 90% on the training set and 80% on the testing set. The results are implementable and realizable using off-the-shelf tools. The goal is to design with domain experts an energy monitoring system that can be configured once and then widely deployed with little additional cost or effort.

47 OTHER INSTRUMENTATION↗

Position resolution simulations for the inverted-coaxial germanium detector, SIGMA

The SIGMA Germanium detector has the potential to revolutionise γ-ray spectroscopy, providing superior energy and position resolving capabilities compared with current large volume state-of-the-art Germanium detectors. The theoretical position resolution of the detector as a function of γ-ray interaction position has been studied using simulated detector signals. A study of the effects of RMS noise at various energies has been presented with the position resolution ranging from 0.33 mm FWHM at Eγ = 1, to 0.41 mm at Eγ = 150 keV. Here, an additional investigation into the effects pulse alignment have on pulse shape analysis and in turn, position resolution has been performed. The theoretical performance of SIGMA operating in an experimental setting is presented for use as a standalone detector and as part of an ancillary system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of Sediment Bed Behavior for Critical Velocity in Horizontal Piping

This paper compares results from a predictive tool for modeling transport of a multiphase mixture (solids in a liquid) in a pipeline, (up to and including plugging) with experiments performed to support the Hanford site’s Waste Treatment and Immobilization Plant (WTP). The treatment of high-level waste at the DOE Office of River Protection’s WTP will involve the transfer of high solid content suspensions through pipelines. Pipeline plugging was identified as a significant potential issue by a panel of external experts. In response to their concerns an experimental effort was initiated at PNNL to determine the critical velocities for a variety of operating conditions. A computational method has been developed to predict the dynamic behavior of a sediment bed in response to the surrounding suspension flow. The flow field is modeled using a lattice kinetics method, similar to the lattice Boltzmann method, which scales very well on highly parallel computers. Turbulent quantities are calculated using a k-epsilon RANS model. This work is part of a larger effort to develop a process simulation capability for a wide range of applications. Solids are represented using two different continuum fields. The suspended solids are treated as passive scalars in the flow field, including terms for hindered settling and Brownian diffusion. Normal stresses created by the irreversible collisions of particles during shearing are added to the pressure tensor. The sediment bed interface is represented using a continuum phase field with a diffuse interface. The bed may change with time due to settling, erosion and deposition through convection. The erosion rates are calculated using the local shear stress obtained from the turbulence model. The method is compared with data from the PNNL pipeline experiments conducted at PNNL (Poloski et al. 2008). The experimental flow loop consists of 3-inch schedule 40 piping with instrumentation for determining flow rate and pressure gradient. The simulant test particles ranged in density from 2.5 to 8 g/cc while the nominal particle size ranged from 10 to 100 μm. At the beginning of each test, the slurry flow velocity was nominally set to 8 ft/sec. The flow was incrementally ramped down, and a steady-state pressure gradient was obtained at each flow condition. A rise in pressure gradient as the flow rate drops indicates that the pipe cross-sectional area is beginning to fill with sediment. This point is referred to as the “critical velocity”. Visualization information is provided using Electrical Resistance Tomography (ERT). The paper will show favorable comparison of results with data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Induced Environment Contamination Monitor for the Space Shuttle

The Induced Environment Contamination Monitor (IECM), a set of ten instruments integrated into a self-contained unit and scheduled to fly on shuttle Orbital Flight Tests 1 through 6 and on Spacelabs 1 and 2, is described. The IECM is designed to measure the actual environment to determine whether the strict controls placed on the shuttle system have solved the contamination problem. Measurements are taken during prelaunch, ascent, on-orbit, descent, and postlanding. The on-orbit measurements are molecular return flux, background spectral intensity, molecular deposition, and optical surface effects. During the other mission phases dew point, humidity, aerosol content, and trace gas are measured as well as optical surface effects and molecular deposition. The IECM systems and thermal design are discussed. Preflight and ground operations are presented together with associated ground support equipment. Flight operations and data reduction plans are given.

Miller, E. R.↗

Building a QC Database of Meteorological Data From NASA KSC and the United States Air Force's Eastern Range

The National Aeronautics and Space Administration's (NASA) Marshall Space Flight Center (MSFC) Natural Environments Branch (EV44) has provided atmospheric databases and analysis in support of space vehicle design and day-of-launch operations for NASA and commercial launch vehicle programs launching from the NASA Kennedy Space Center (KSC), co-located on the United States Air Force's Eastern Range (ER) at the Cape Canaveral Air Force Station. The ER is one of the most heavily instrumented sites in the United States measuring various atmospheric parameters on a continuous basis. An inherent challenge with the large databases that EV44 receives from the ER consists of ensuring erroneous data are removed from the databases, and thus excluded from launch vehicle design analyses. EV44 has put forth great effort in developing quality control (QC) procedures for individual meteorological instruments; however, no standard QC procedures for all databases currently exist resulting in QC databases that have inconsistencies in variables, methodologies, and periods of record. The goal of this activity is to use the previous efforts by EV44 to develop a standardized set of QC procedures from which to build flags within the meteorological databases from KSC and the ER, while maintaining open communication with end users from the launch community to develop ways to improve, adapt and grow the QC database. Details of the QC checks are described. The flagged data points will be plotted in a graphical user interface (GUI) as part of a manual confirmation that the flagged data do indeed need to be removed from the archive. As the rate of launches increases with additional launch vehicle programs, more emphasis is being placed to continually update and check weather databases for data quality before use in launch vehicle design and certification analyses.

Brenton, James C.↗

Phase Retrieval Implementation for the WFIRST Coronagraph Development Testbed

The Wide-Field Infrared Survey Telescope (WFIRST) is a 2.4m diameter space telescope NASA program. The payload will include two instruments, including a coronagraph instrument (CGI). The CGI will be the first active, high-contrast stellar coronagraph in space intended for imaging, discovery, and spectral characterization of exoplanets and debris discs. The CGI designs under development use deformable mirrors (DM) to create a point spread function (PSF) with a dark region around the obscured star object. Each DM consists of an array of actuators, and each actuator causes a local displacement to a thin, mirror-coated, glass face sheet. The actuator displacements are designed to create the PSF. Typically, phase retrieval is used to set the DM actuator displacements to their designed pattern, and then the actuators are further modified by an iterative control loop to correct for system non-idealities. To observe an exoplanet near the star object, the contrast in the annular region must be better than 10^8 (10^9 after post processing) relative to the unobstructed image of the star [1,2]. The coronagraph testbed at Jet Propulsion Laboratory is used to test coronagraph design and control algorithms. The optical system (Fig. 1) is maintained in a vacuum tank so that the PSF is stable for long integration times. Phase retrieval is an important tool for the testbed and serves several purposes, in addition to setting initial DM actuator displacements. Other uses include evaluation of systematic wavefront error introduced by system components, and alignment of the DMs and pupil masks. For example, the location of specific DM actuators relative to the Lyot mask can be determined by displacing the actuator, then measuring the location of the phase disturbance in the pupil plane with phase retrieval. In the next section we further describe the optical train of the testbed and the collection of source and pupil images available as inputs for phase retrieval, as well as one phase retrieval algorithm employed. Section 3 shows example phase retrieval results.

Marx, David↗

The International Space Station: A Unique Platform for Remote Sensing of Natural Disasters

Assembly of the International Space Station (ISS) was completed in 2012, and the station is now fully operational as a platform for remote sensing instruments tasked with collecting scientific data about the Earth system. Remote sensing systems are mounted inside the ISS, primarily in the U.S. Destiny Module's Window Observational Research Facility (WORF), or are located on the outside of the ISS on any of several attachment points. While NASA and other space agencies have had remote sensing systems orbiting Earth and collecting publicly available data since the early 1970s, these sensors are carried onboard free-flying, unmanned satellites. These satellites are traditionally placed into Sun-synchronous polar orbits that allow imaging of the entire surface of the Earth to be repeated with approximately the same Sun illumination (typically local solar noon) over specific areas, with set revisit times that allow uniform data to be taken over long time periods and enable straightforward analysis of change over time. In contrast, the ISS has an inclined, Sun-asynchronous orbit (the solar illumination for data collections over any location changes as the orbit precesses) that carries it over locations on the Earth between approximately 52degnorth and 52deg south latitudes (figure 1). The ISS is also unique among NASA orbital platforms in that it has a human crew. The presence of a crew provides options not available to robotic sensors and platforms, such as the ability to collect unscheduled data of an unfolding event using handheld digital cameras as part of the Crew Earth Observations (CEO) facility and on-the-fly assessment of environmental conditions, such as cloud cover, to determine whether conditions are favorable for data collection. The crew can also swap out internal sensor systems installed in the WORF as needed. The ISS orbit covers more than 90 percent of the inhabited surface of the Earth, allowing the ISS to pass over the same ground locations at different times of the day and night. This is important for two reasons: 1) certain surface processes (i.e., development of coastal fog banks) occur at times other than local solar noon, making it difficult to collect relevant data from traditional satellite platforms, and 2) it provides opportunities for the ISS to collect data for short-duration events, such as natural disasters, that polar-orbiting satellites may miss due to their orbital dynamics - in essence, the ISS can be "in the right place at the right time" to collect data. An immediate application of ISS remote sensing data collection is that the data can be used to provide information for humanitarian aid after a natural disaster. This activity contributes directly to the station's Benefits to Humanity mission. The International Charter, Space and Major Disasters (also known as the International Disaster Charter, or IDC) is an agreement between agencies of several countries to provide - on a best-effort basis - remotely sensed data related to natural disasters to requesting countries in support of disaster response. In the United States, the lead agency for interaction with the IDC is the United States Geological Survey (USGS); when an IDC request, or activation, is received, the USGS notifies the science teams for NASA instruments with targeting information for data collection. In the case of the ISS, Earth scientists in the JSC ARES Directorate, in association with the ISS Program Science Office, coordinate targeting and data collection with the USGS. If data is collected, it is passed back to the USGS for posting on its Hazards Data Distribution System and made available for download. The ISS was added to the USGS's list of NASA remote sensing assets that could respond to IDC activations in May 2012. Initially, the NASA ISS sensor systems available to respond to IDC activations included the ISS Agricultural Camera (ISSAC), an internal multispectral visible-near infrared wavelength system mounted in the WORF; CEO, a project that collects imagery through the ISS windows using off-the-shelf handheld digital visible-wavelength cameras; and the Hyperspectral Imager for the Coastal Oceans (HICO), a visible to near-infrared system mounted externally on the Japanese Experiment Module - Exposed Facility. Since May 2012, there have been 37 IDC activations; ISS sensor systems have collected data for 10 of these events.

Stefanov, William L.↗

Chemical/Optical Properties of Oliktok Aerosols Field Campaign Report

The arctic environment is changing at an alarming rate. During this time of escalation, it is important to understand the impacts of aerosols, both natural and anthropogenic. To support this effort, an aerosol sampling campaign was conducted at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility third Mobile Facility (AMF3) at Oliktok Point on the North Slope of Alaska (NSA). The specific objectives of the campaign were to collect aerosol particles as a function of aerodynamic particle size in order to better understand the varying chemical and optical properties of the aerosols in the different particle size modes. A DRUM-style cascading impactor (Davis Rotating-Unit for Monitoring) was deployed at the beginning of March 2017 through the end of May 2017, collecting samples in eight size bins for each 12-hour period, thereby obtaining a diurnal signature. On March 6, a fire burned down the power generation shed at the sampling site. No samples were collected again until March 10. Due to DRUM sampler rotation issues, samples were collected intermittently until March 13. From March 14 through the end of the study, samples were collected with little interference. The size bins of the instrument range from approximately 10 to 0.09 μm; however, deployment at the Oliktok Point facility required an inlet configuration that effectively filtered out the coarsest size bin. Therefore, the reported size bins are 5.0 to 2.5, 2.5 to 1.15, 1.15 to 0.75, 0.75 to 0.56, 0.56 to 0.34, 0.34 to 0.26, and 0.26 to 0.09 μm. It is also possible that ultrafine particles were removed by electrostatic charging of the high-density polyethylene inlet tubing; however, confirmation of this would require further testing. The collected samples were returned to the University of California (UC), Davis for offline analysis. Particle mass concentrations were measured by soft-beta ray attenuation while optical attenuation was determined by broadband transmission spectrometry (10 wavelengths from 349 to 849 nm in 50 nm increments, minus 649 nm). The samples were then taken to the Advanced Light Source facility at Lawrence Berkeley National Laboratory for synchrotron-induced X-ray fluorescence spectrometry (SXRF). Thirty elements were detected, from sodium to molybdenum plus lead. The polarized nature of the synchrotron beam eliminates 97.5% of the primary Compton background, providing approximately a factor of 10 greater sensitivity than unpolarized X-ray instruments (Barberie et al. 2013). The data were reduced using custom software packages and analyzed for any sources of contamination, sample damage, or other potential causes of data invalidation. The interpretation of the final data set is ongoing and only early results will be described in this report. In spite of power and instrumental issues at the start, the field campaign was largely successful. Excluding the first stage that did not receive sample and power/rotational issues, the remaining stages were 99.7% complete (number of valid measurements/total number of measurements made). The percent of measurements below detection were < 30% for all species with the exception of sodium, magnesium, arsenic, and scandium. Sodium and magnesium were expected to be difficult to measure using SXRF due to low sensitivity at that energy range. Scandium is very rare in ambient samples unless near a very strong source. Arsenic is fairly common in urban settings but is not expected in the arctic environment.

54 ENVIRONMENTAL SCIENCES↗

Long-term monitoring experiences at the HADES underground lab and its relevance for radwaste repository monitoring

In the frame of its radwaste disposal research programme, SCK-CEN started the construction of the HADES underground research facility in 1980. Including several extensions and a comprehensive experimental programme, it has provided a lot of experience on monitoring. Monitoring is performed for many reasons: construction follow-up, field characterisation, investigation of phenomena, and model validations - in which the underground lab offers the opportunity for up-scaling conventional laboratory set-ups. Construction monitoring has allowed to develop and optimise the underground construction techniques in a previously poorly known environment, resulting in a well-mastered application of mechanised methods for gallery construction with minimal damage to the host formation. Access to this formation also allows its characterisation, both geotechnical, geological and geochemical, and the detailed investigation of phenomena such as fracturing and oxidation. Finally, instrumented set-ups allow to test various numerical models by comparing the observations with the predicted behaviour. The specific conditions of the underground laboratory put particular requirements to the sensors. These conditions include the long-term nature of many set-ups - typically several years to decades, the inaccessibility of many sensors after installation, high mechanical and water pressures, and corrosion. Combined with the fact that many sensors are custom made, obtaining and maintaining a fully functional instrumented set-up can be challenging. A lot of experience has therefore been gained which is very valuable when designing the monitoring of radwaste repositories - and it has allowed us to determine the critical success factors for monitoring. Engineers tend to look at this first from a technical viewpoint - and there are many technical aspects indeed that determine the reliability of monitoring. A first one is the combination of different observations ('redundancy') which can be implemented by the use of several sensors, different sensor principles, different (coupled) parameters, and the combination of point measurements with geophysical techniques. Cabling is also a critical issue as it is often considered as the primary enemy of barrier integrity. Minimal cabling techniques, such as distributed fibre optic monitoring and wireless signal transmission, therefore get increasing attention. Also the interpretation of the monitoring data - in particular those that are perceived as 'wrong' or 'unexpected', needs sufficient attention. The long-term experience has however also shown that the design of a monitoring programme must look beyond the technical part. In particular for long-term applications, issues such as data management and record keeping are vital to guarantee success in this. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lightning measurements from the Pioneer Venus Orbiter

The plasma wave instrument on the Pioneer Venus Orbiter frequently detects strong and impulsive low-frequency signals when the spacecraft traverses the nightside ionosphere near periapsis. These particular noise bursts appear only when the local magnetic field is strong and steady and when the field is oriented to point down to the ionosphere thus; the signals have all characteristics of lightning whistlers. We have tried to identify lightning sources between the cloud layers and the planet itself by tracing rays along the B-field from the Orbiter down toward the surface. An extensive data set, consisting of measurements through Orbit 1185, strongly indicates a clustering of lightning sources near the Beta and Phoebe Regios, with an additional significant cluster near the Atla Regio at the eastern edge of Aphrodite Terra. These results suggest that there are localized lightning sources at or near the planetary surface.

Scarf, F. L.↗

Measurement of tropospheric carbon monoxide using gas filter radiometers

The measurement of tropospheric carbon monoxide with gas filter radiometers is examined on the basis of the MAPS experiment. The performance characteristics of an instrument that uses the MAPS detectors, broadband filters, and gas cells in a system similar to the GASCOFIL system described by Morrow and Nicholls (1985) is determined. The signal function for two carbon monoxide channels of the MAPS instrument as it was flown in 1981 is shown. The measurements of the lower pressure channel are weighted to a higher altitude. The signal function, when integrated over altitude and multiplied by the normalization constant, yields the value of the signal. Both signal functions approach zero at the top because the gas concentration approaches zero. The present data reduction technique assumes that there are no clouds in the field of view. If clouds are present, the inferred carbon monoxide mixing ratio is too high, and those points must be rejected from the data set.

Reichle, Henry G., Jr.↗

Analysis of Solar Spectral Irradiance Measurements from the SBUV/2-Series and the SSBUV Instruments

The NOAA-9 SBEV/2 instrument has made the first regular measurements ot solar UV activity over a complete solar cycle, beginning in March 1985 and continuing as of this writing. The NOAA-9 solar irradiance data set includes the minimum between Cycles 21-22 and the current minimum at the end of Cycle 22. Although overall solar activity is low during these periods, 27-day rotational modulation is frequently present. The episode of 13-day periodicity observed during September 1994 - March 1995 shows that phenomena previously associated with high levels of solar activity can occur at any point in the solar cycle. The 205 nm irradiance and Mg II index measured by NOAA-9 showed very similar behavior during the Cycle 21-22 minimum in 1985-1986, when 27-day periodicity dominated short-term solar variations, but behaved differently in 1994-1995 during the episode of 13-day periodicity. We plan further investigations into the physical causes of this result, since it affects the extent to which the Mg II index is an accurate proxy for 205 nm irradiance variations during such episodes. The NOAA-9 Mg II data are available.

Cebula, Richard P.↗

Energy Efficiency in Small Server Rooms: Field Surveys and Findings

Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of pseudo-random binary arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown Point-Spread Function (PSF) of the instruments [1] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in a spatial frequency domain as a Power Spectral Density (PSD) distribution [2]. For example, the measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [3], [4]. The distortion of the surface PSD distribution due to the PSF can be modeled with the Modulation Transfer Function (MTF), which is defined over the spatial frequency bandwidth of the instrument [1], [2]. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the System Under Test (SUT). Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. In previous work [5], [6] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on Binary Pseudo-Random (BPR) gratings. Here, we present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription [7] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples. [8] Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

36 MATERIALS SCIENCE↗