Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Bridging length scales in hard materials with ultra-small angle X-ray scattering – a critical review

Owing to their exceptional properties, hard materials such as advanced ceramics, metals and composites have enormous economic and societal value, with applications across numerous industries. Understanding their microstructural characteristics is crucial for enhancing their performance, materials development and unleashing their potential for future innovative applications. However, their microstructures are unambiguously hierarchical and typically span several length scales, from sub-ångstrom to micrometres, posing demanding challenges for their characterization, especially for in situ characterization which is critical to understanding the kinetic processes controlling microstructure formation. This review provides a comprehensive description of the rapidly developing technique of ultra-small angle X-ray scattering (USAXS), a nondestructive method for probing the nano-to-micrometre scale features of hard materials. USAXS and its complementary techniques, when developed for and applied to hard materials, offer valuable insights into their porosity, grain size, phase composition and inhomogeneities. We discuss the fundamental principles, instrumentation, advantages, challenges and global status of USAXS for hard materials. Using selected examples, we demonstrate the potential of this technique for unveiling the microstructural characteristics of hard materials and its relevance to advanced materials development and manufacturing process optimization. We also provide our perspective on the opportunities and challenges for the continued development of USAXS, including multimodal characterization, coherent scattering, time-resolved studies, machine learning and autonomous experiments. Our goal is to stimulate further implementation and exploration of USAXS techniques and inspire their broader adoption across various domains of hard materials science, thereby driving the field toward discoveries and further developments.

36 MATERIALS SCIENCE↗

Agilent AgileBioFoundry CRADA

NTESS, LBNL, PNNL, and Agilent are collaborating to expand a prototype system that processes hundreds of samples per day by UHPLC-QTOF mass spectrometric-based target methods for both metabolomic and proteomic application sin support the needs of strain optimization. Extending this technology to targeted triple quadrupole and drift tube ion mobility spectrometry mass spectrometric analyses offers direct advantages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Mission Profiles for Humidity Models in the Reliability Testing of PV Inverters: Preprint

To understand the impacts of humidity on PV inverters, mission profiles were developed to accurately describe the different processes and rates based on the environmental factors of temperature, relative humidity, and irradiance. The operating environment of the device introduces stress factors dependent on component temperature, relative humidity, and component voltage. The development of profiles started from looking at historical climate conditions at Cocoa, Florida, a hot and humid location. The profile developed from field location was compared with existing humidity test profiles in industrial and military standards to determine acceleration factors. Prior to the evaluation of the mission profiles, critical components in the PV inverter were identified based on vendor discussions along with failure modes of interest. The profiles considered in this study was demonstrated using a 4-kVA string inverter. The measurements from the devices were substituted in device manufacturer specified equation to determine the severity of each test. The severity of each test was compared against the severity of the 24-hour result to determine the acceleration factor of each test. The acceleration factors were determined to be over a range of 1.2-6 for the existing humidity tests from standards, when compared against the mission profile developed from field data. This optimal humidity/thermal profile will be passed to the IEC standards development for inverter qualification testing.

humidity models↗

Effective sensor location for detection of change in structural dynamic response

This paper investigates the sensitivity of structural system response to the sensor location by investigating consequences of small changes in the location to the structural system response. The paper discusses how maximum observability (based on mode shape and the participation of that mode in the input provided) drives optimal location. The structural responses were investigated in terms of the g-rms response for various low-frequency inputs (pure sinusoids and real-life inputs such as an earthquake and trains). Results were then analyzed in the context of Modal Contributions Factors (MCF) and changes to the Force-to-response Transfer Functions (TRFs). A modal-matching process is first presented using a Matlab TM -based Finite Element Method (FEM) model of a cantilever beam and instrumentation to determine the location of a small mass based on three different criteria. Subsequently, the structural response is investigated using experiments and the FEM model. The accelerometer of small mass (at 1/3 height) was moved up or down to obtain changes in the structural response (TRF) to various realistic low-frequency inputs. Modal Contribution Factor (MCF) and derivative (slope) of the associated mode-shapes were correlated to the observed changes in TRFs. Results show how optimal sensor locations for detecting change in structural response can be based on the MCFs and the associated mode-shapes.

Woodall, J.↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

BCARS Simulated Phantom Dataset for Evaluation of Processing Pipelines

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a powerful label-free biological imaging technique, but the raw signal requires careful processing. The vibrationally resonant (Raman) fingerprint signal is usually small compared with instrumental noise sources and the nonresonant background (NRB) inherent in the BCARS signal. Fortunately, the NRB exhibits a systematic phase relationship with the coherent Raman response, acting as a heterodyne amplifier for the weak fingerprint signal. Due to this heterodyne effect, the Raman response can be recovered quantitatively and invariantly across different instruments, provided the NRB shape is known. Even with heterodyne amplification, the amplitudes of fingerprint signal components are often comparable to system noise. Singular value decomposition (SVD), which utilizes spatial information, is often employed for additional noise filtering. Consequently, finding optimal processing parameters to properly distinguish the NRB and Raman responses and suppress noise in the complex BCARS signal requires a reference system that realistically represents the spectral and spatial properties of BCARS signals obtained from biological samples. We present a digital tissue phantom that meets these criteria as a tool for testing candidate signal processing pipelines. The digital phantom is generated with simulated hyperspectral Raman images having system-specific noise and background characteristics. Here, we analyze phantom datasets with differing background and signal-to-noise conditions to evaluate their impact on the performance of multiple signal processing pipelines. Specifically, we investigate the application of a Butterworth filter-based routine to directly estimate the NRB from the BCARS signal. Additionally, we evaluate a Lorentzian wavelet transform as an alternative to the Hilbert transform for extracting the Raman spectrum from the BCARS signal. While we demonstrate this phantom for BCARS, it can be used for any spectroscopic Raman imaging approach.

Dixon, Jessica Z. [Georgia Institute of Technology↗

HLS4ML Integration with QICK

The QICK (Quantum Instrumentation Control Kit) integration aims to enhance the readout of superconducting qubits by leveraging machine learning (ML) techniques. These techniques offer high accuracy, increased speed, and better state preservation for qubit readouts. The integration process employs neural network algorithms to optimize system performance and achieve high accuracy rates. The QICK board uses an FPGA, allowing for efficient real-time processing and high-performance execution of machine learning algorithms.

Ali, Mohamud↗

The impact of detection rate changes and correlations on random-coincidence background measurements

Coincidence detection of multiple particles emitted during an experiment can yield a new depth of understanding of the underlying process under study. However, the probability of detecting particles that are generated from the same physical event within a given coincidence time window is generally much lower than that of detecting particles that appear in the same coincidence time window, but were not created from the same physical event, and are therefore detected randomly in coincidence with each other. Thus, accurate and precise methods of measuring this random-coincidence background are essential for a wide variety of fields of science. A method to determine this background directly using the data themselves without any additional experimental run time or fake signals introduced in the data was recently established (O’Donnell, 2016). This method yields a statistical uncertainty on the random-coincidence background that is orders of magnitude smaller than that of the true coincidence data, though the potential for systematic errors of backgrounds from this method was never explored. In this work, we discuss common varieties of correlated and uncorrelated changes in the detection rates of each particle detected in an experiment. Here we demonstrate here that a correlation between particle detection rates from, for example, an incident particle beam that initiates a physical process of interest, creates systematic errors in the random-coincidence background measurement. We also discuss the impact of a variety of other realistic scenarios for rate changes in experiments. Lastly, a method is introduced to correct for errors in the random-coincidence background from any source, yielding an optimization between statistical precision and eliminating potential lingering systematic errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Scribing for Electrode Patterning of Perovskite Spectrometer-Grade CsPbBr 3 Gamma-ray Detectors

Making semiconductor radiation detectors that work at room temperature relies heavily on the deposition and pixelation of electrodes. Electrode patterning of perovskite solar cells widely implements laser scribing techniques, which is a convenient, scalable, and inexpensive technique. However, this method has not found its application in radiation detector patterning yet, and the question whether laser scribing can achieve high-quality patterns with minimum damage to a detector crystal and low interpixel cross-talk remains largely unanswered. To prove that laser scribing is a practical method for electrode patterning on perovskite CsPbBr 3 detectors, we use the material to create a variety of patterns. A very low lateral leakage current (60 nA at 10 V) and high mobility-lifetime product (9.7(3) x 10 -4 cm 2 /V) were observed between the pixel and the guard ring in tests of single-pixel devices with a separation of 200 or 100 μm between the central electrode and the guard ring. The 122 and 136 keV photopeaks in 57 Co gamma-ray spectra were very well resolved with an energy resolution of up to 6.1% at 122 keV. Finally, a further reduction in gap size to 50 mu m is conceivable, but more process optimization is needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic inspection of program state in an uncooperative environment

Abstract The program state is formed by the values that the program manipulates. These values are stored in the stack, in the heap, or in static memory. The ability to inspect the program state is useful as a debugging or as a verification aid. Yet, there exists no general technique to insert inspection points in type‐unsafe languages such as C or C++. The difficulty comes from the need to traverse the memory graph in a so‐called uncooperative environment. In this article, we propose an automatic technique to deal with this problem. We introduce a static code transformation approach that inserts in a program the instrumentation necessary to report its internal state. Our technique has been implemented in LLVM. It is possible to adjust the granularity of inspection points trading precision for performance. In this article, we demonstrate how to use inspection points to debug compiler optimizations; to augment benchmarks with verification code; and to visualize data structures.

Magalhães, José Wesley de Souza↗

What Makes Au Nanospheres Superior to Octahedral and Cubic Counterparts for the Deposition of a Pt Monolayer Shell?

This study demonstrates that Au nanospheres are advantageous over their octahedral and cubic counterparts as seeds in the synthesis of Au@Pt core−shell nanocrystals with a monolayer shell. In combination with experimental characterization, we show through training a machine-learned interatomic potential that the Au nanospheres exhibit a large fraction of lowcoordination atoms which are uniformly distributed over the surface. The corresponding high-index facets, including {211}, {311}, {331}, {210}, and {310}, on a spherical seed promote nucleation while greatly shortening the diffusion distance for adatoms. In addition, the high-index facets are instrumental in retaining the deposited Pt atoms on the outermost surface by retarding their inter-diffusional exchange with the underlying Au atoms. By switching from a monolayer made of pure Pt to those made of Pt−Au alloys, we can optimize both the activity and selectivity of the nanocrystals toward the two-electron oxygen reduction reaction for the electrochemical synthesis of H 2 O 2 . This method should be extendible to the fabrication of other core−shell nanocatalysts with desired monolayer shells for various catalytic reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Colorado State University Extension Industrial Assessment Center

Since its inception in 1984, the Colorado State University Industrial Assessment Center has performed industrial assessments at more than 720 manufacturing facilities in Colorado, Montana, Nebraska, Nevada, New Mexico, North Dakota, South Dakota, Utah, and Wyoming. From 2017 to 2019 there was a funding gap and the IAC shutdown. In 2020 through DOE extension funding the University relaunched the IAC as an extension center in order to provide assessments to underserved areas. Under this award, the CSU Industrial Assessment Center (IAC) was rebuilt with the help of student employees and the director. The CSU team experienced difficulty as the program was in the process of being restarted right as the 2020 pandemic hit. Nonetheless, the CSU IAC was instrumental in providing energy assessments to manufacturers in Colorado and Wyoming during the period of performance of 09/2019 – 12/2022. The Department of Energy's Industrial Assessment Centers (IACs) provide a valuable service to small and medium-sized manufacturers seeking to optimize their operations. These university-based centers offer no-cost, on-site assessments conducted by engineering faculty and students, analyzing energy consumption, production processes, and waste streams. They utilize advanced data acquisition systems to record operational data, and then use the data to create assessment recommendations. These recommendations form the foundation of the comprehensive energy report. The comprehensive report delivers actionable recommendations for enhancing energy efficiency, reducing waste, and reducing greenhouse gas emissions and improving productivity, often identifying significant cost savings. Furthermore, IACs facilitate access to implementation grants, enabling the businesses to readily adopt these improvements. This program not only strengthens individual businesses but also contributes to national goals of training the next generation of energy experts, as well as increasing industrial competitiveness and reduced environmental impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Optimization of the Proposed NB2 Guide System in the HFIR Cold Guide Hall

The NB2 Guide Design is used to provide a defined neutron beam flux to at least one monochromator and an end station. The known monochromator configuration will support a sample alignment station and the end station will be able to accommodate either a neutron polarization development instrument or a spin echo neutron spectrometer, as well as the potential for additional monochromators along the guide path. The design proposed will meet the needs specified for those instruments defined by science requirements documents, and will also provide insight into potential opportunities for future instrument developments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Resolution Image Products Acquired from Mid-Sized Uncrewed Aerial Systems for Land–Atmosphere Studies

We assess the viability of deploying commercially available multispectral and thermal imagers designed for integration on small uncrewed aerial systems (sUASs, <25 kg) on a mid-size Group-3-classification UAS (weight: 25–600 kg, maximum altitude: 5486 m MSL, maximum speed: 128 m/s) for the purpose of collecting a higher spatial resolution dataset that can be used for evaluating the surface energy budget and effects of surface heterogeneity on atmospheric processes than those datasets traditionally collected by instrumentation deployed on satellites and eddy covariance towers. A MicaSense Altum multispectral imager was deployed on two very similar mid-sized UASs operated by the Atmospheric Radiation Measurement (ARM) Aviation Facility. This paper evaluates the effects of flight on imaging systems mounted on UASs flying at higher altitudes and faster speeds for extended durations. We assess optimal calibration methods, acquisition rates, and flight plans for maximizing land surface area measurements. We developed, in-house, an automated workflow to correct the raw image frames and produce final data products, which we assess against known spectral ground targets and independent sources. We intend this manuscript to be used as a reference for collecting similar datasets in the future and for the datasets described within this manuscript to be used as launching points for future research.

47 OTHER INSTRUMENTATION↗

Enhanced deep neural networks with transfer learning for distribution LMP considering load and PV uncertainties

As the flexibility of generation and demand increases in distribution systems, the residential loads are emerging as a promising means to participate in demand response and the transactive energy market. Market pricing is an instrumental mechanism for the distribution system operator to exploit the full potential of the flexible resources. The distribution locational marginal price (DLMP) can be used to guide the residential load consumption. This type of market signal helps the distribution system operator to optimize the scheduling of all resources while satisfying related network constraints through a day-ahead market. However, solving the optimization problem for large-scale systems can be computationally expensive. To address the scalability and practicability limitations of the DLMP framework, a learning-based approach is proposed in this paper to complement the day-ahead distribution market framework. Here, the proposed approach combines long short-term memory and transfer learning to develop deep neural network that can capture the spatial–temporal correlation of the input data. The model can determine the optimal DLMP for each node in a distribution system without the system parameters required to formulate the optimization problem. Testing results on IEEE 33-bus and 123-bus systems show that the proposed approach can generate a comparable DLMP against the optimization solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compound pulse characteristics of a heterogeneous composite scintillator in a gamma-ray field

An important aspect of radiation detection in scintillators is the time dependence of emitted fluorescence, which results in characteristic measured pulse shape. In some materials, a relatively strong dependence of the scintillation pulse shape on stopping power exists, which can provide reliable identification of the incident particle. An alternative method to realize particle identification is by combining materials with different fluorescence lifetimes into heterogeneous structures. Such composite scintillators derive their properties from both the constituent material characteristics and the geometry of the composite structure. In composite scintillators with a high degree of heterogeneous loading, a superposition of fluorescence contributions originating in multiple materials, which is observed as single waveform with an intermediate pulse shape, may affect its ability to reject rays. We measure the time dependence of light output from a scintillator composed of 6 Li-containing glass shards and scintillating polyvinyl toluene and identify events that exhibit such compound behavior when exposed to rays and fast neutrons. We develop a modeling and simulation framework that reproduces the pulse shapes in heterogeneous scintillators and use it study the effect that the weight percentage of 6 Li glass has on rejection. The modeling framework is applied to the experimentally studied scintillator, finding a good agreement. Here, the developed modeling and simulation approach will help optimize the design of heterogeneous scintillators to meet the desired trade-o between neutron capture efficiency and -ray rejection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗