Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

Magellan: The unveiling of Venus

In the late 1970s and early 1980s, the United States and the Soviet Union sent the Pioneer Venus and Venera spacecraft, respectively, to study Venus more closely and to image its surface with radar. These missions have answered many questions about Venus, but many more questions remain unanswered about the extent to which Venus' surface was shaped by volcanoes, plate tectonics, impact craters, and water and wind erosion. To help answer these remaining questions a new radar imaging spacecraft Magellan will be launched from the Space Shuttle. Magellan will spend eight months mapping most of the planet at a resolution nearly ten times better than any previous views of the surface. The mission of Magellan, the radar equipment, orbiting of Venus, planetary imaging, and surface exploration are discussed.

Source record↗

Jet ejecta mass upon oblique impact

Theoretical models in the jetting regime for symmetric and asymmetric impact of thin plates predict the mass and velocity of jetted material upon oblique impact. However, experimental constraints on the amount of material which form jets upon oblique impact are not known. A series of preliminary experiments were conducted in which tungsten (W) flyer plates at speeds of 1.5 to 2.0 km/s were obliquely impacted into carbon targets at 30 deg in the regime of jetting, yielding radiation temperatures in the about 3200 K range. Both framing-camera and flash X-ray imaging were conducted. Broad cm-sized craters induced by jet ejecta on 2024 Al witness plates were used to infer jet mass. We infer, from measured witness plate crater volumes, that jet masses in the range of 0.01 to 0.06 g are produced by a 32 mm diameter, 6 mm thick W impactor. This is about one to two orders of magnitude less than those calculated from present theoretical models. In contrast, in refractory material experiments, the mass of gabbro ejecta trapped in styrofoam is 0.52 g, which is similar to that calculated.

Yang, W.↗

Surface photometry of comet P/Encke

A scheme to clean cometary digital images from offending background-star trails, and this technique has been applied to a pair of deep Kitt Peak 4-m plates of comet P/Encke, taken in October 1980. Simultaneous and subsequent digital spectra have been obtained at Lick Observatory. The non-polluted coma images show a strong asymmetric sunward-oriented fan/jet, and an extended and rounder (mostly gaseous) main coma, out to approximately 100,000 km radius. The stellar-trail point-spread function has a narrow width (sigma approximately 0.6 arcsec), so that spatial resolution better than approximately 300 km is achieved at the comet. The photometric gradient near the nucleus is very steep, strongly suggesting an icy-grain component which evaporates quickly (at radii equal to or less than 500 km) in the sunlight. Further from the nucleus, the profile becomes shallower, bluer, and more gas dominated. The effect of solar radiation pressure on C2, CN, and other molecules is probably responsible for the rounding of the outer, fainter isophotes. The source of the molecules is likely to be larger than the nucleus itself, and a substantial fraction may originate in the jet. The technique described here may also be applicable in surface photometry of galaxies, in cases where the heavy image pollution by foreground stars is present.

Djorgovski, S.↗

Cometary spectroscopy

The spectroscopic and morphological characteristics of comets over a wide range of heliocentric distances are investigated as they may suggest or constrain models of cometary formation environments and evolution. This program also contributes to the understanding of the general comet population with which spacecraft data will be compared. Long slit spectra and direct images of all observable comets (M2<18) are obtained on a monthly basis with either a UV sensitive microchannel plate or a red sensitive CCD spectrograph/camera. Scale lengths of the principal emission of OH, NH, CN, C3, C2, NH2 and OI different comets can be compared. The direct images are used for studies of dust anisotropy which can provide data on the spin vector and gross surface morphology.

Larson, S.↗

Melt Pool Imaging using a Configurable Architecture Additive Testbed System

This paper describes the inline (coaxial to laser) near infrared (NIR) camera sensor on the Configurable Architecture Additive Testbed (CAAT). The CAAT is an instrument that provides the capability to investigate laser based additive manufacturing (AM) processes and is configured for the metal powder bed fusion process. A low cost NIR camera is radiometrically calibrated to obtain coaxial, inline, imagery of laser generated melt pools. The camera capabilities, system optical path, and the uncertainty in the temperature measurement from NIR surface area scans on a bare titanium alloy plate are presented and discussed. The surface radiance measurements are compared to optical microscopy images of the melt pool width and depth. A metallic additive manufacturing process thermal model is developed in order to predict thermal distributions during laser scanning. The predicted thermal distributions by the model for different configurations are compared to the coaxial NIR measurements and discussed.

Additive manufacturing↗

X-ray telescope module for the LAMAR Space Shuttle experiment

The first of eight X-ray telescopes is under construction for the LAMAR experiment. Each consists of two orthogonal sets of nested confocal one-dimensional parabolic plates of gold-coated float glass, selected for flatness from commercial stock. Each is initially bent to a cylinder by bonding a thin, highly curved titanium sheet to its inactive surface. The final parabolic figure is produced by an automated system which includes seven diode arrays that detect a visible-light line image. Eight precise motorized linear translators operating under the control of a computer, tune the plate to the optimum figure. The plate is then fixed in position by epoxy bonds. The precision of the system is several arcsec, but the intrinsic flatness of the glass is expected to limit the half-power diameter (HPD) of the telescope to about 25 arcsec.

Gorenstein, P.↗

A Classification of Ice Crystal Habits Using Combined Lidar and Scanning Polarimeter Observations during the SEAC4RS Campaign

Using collocated NASA Cloud Physics Lidar (CPL) and Research Scanning Polarimeter (RSP) data from the Studies of Emissions and Atmospheric Composition, Clouds and Climate Coupling by Regional Surveys (SEAC4RS) campaign, a new observational-based method was developed which uses a K-means clustering technique to classify ice crystal habit types into seven categories: column, plates, rosettes, spheroids, and three different type of irregulars. Intercompared with the collocated SPEC, Inc., Cloud Particle Imager (CPI) data, the frequency of the detected ice crystal habits from the proposed method presented in the study agrees within 5% with the CPI-reported values for columns, irregulars, rosettes, and spheroids, with more disagreement for plates. This study suggests that a detailed ice crystal habit retrieval could be applied to combined space-based lidar and polarimeter observations such as CALIPSO and POLDER in addition to future missions such as the Aerosols, Clouds, Convection, and Precipitation (A-CCP).

Natalie Midzak↗

Investigations in the tape-to-tape contact resistance and contact composition in superconducting CORC ® wires

Conductor on Round Core (CORC®) wires and cables, constructed from multiple layers of helically wound REBa 2 Cu 3 O 7–δ tapes, are a promising cable technology for high field magnet applications. An important feature of high-temperature superconductor cables is the ability to share current between conductors, allowing current to bypass drops in I c and minimizing the risk of hot spot formation, which could lead to potential burnout in the superconductor. In contrast to stacked-tape cables, which have continuous contact between tapes, in CORC® the transfer points occur at discrete tape crossovers. The tape-to-tape contact resistance, R c , plays a critical role in the current sharing capabilities and current distribution in cables. For the work reported here, special CORC® wires were manufactured using different winding parameters to investigate variations in R c . Variations comprised inclusion of a lubricant, different lubricant conductivity, inclusion of pre-tinning, and heating briefly to melt the solder. Cables were first tested as straight lengths, followed by bending to a 10 cm diameter. In straight cables R c values ranged from 1 to over 1000 μΩ cm 2 , depending on cabling parameters, with the highest values being found for cables made by the present 'standard' process. Bending the cables to a 10 cm diameter decreased R c by a factor 2–5. Tinning with PbSn decreased R c by three orders of magnitude compared to standard CORC® wires, and heat treating wires with tinned conductor resulted in only a small further decrease in R c . Based on the measured R c at an electric field of 1 μV cm –1 the resulting current transfer length between layers can range from a few millimeters to a tens of centimeters. Examination of contacts with a laser confocal microscope showed plastic deformation of the copper at the edges of the contact overlap area, apparently caused by thicker plating at tape edges digging into the copper of neighboring layers. These images reveal that only a fraction of the total contact surface may actually be touching when there is nothing to compensate for height differential. Images of the PbSn coated tapes indicated that application of solder produces a much more uniform contact surface and higher contact area. Furthermore, imaging of CORC® cross-sections confirmed that in the non-tinned cables there are many regions where tapes are not in contact, while in contrast the PbSn cable shows significantly more contact between the tapes. These different imaging techniques reveal that tape surface morphology is a significant parameter in determining R c .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A position sensitive detector for EUV remote sensing

The authors describe a photon-counting extreme ultraviolet (EUV) detector system used in a rocket-borne spectroscopic instrument for remote sensing of upper atmospheric composition and temperature. The detector uses a KBr coated microchannel plate (MCP) Z stack in combination with a wedge-and-strip image readout system. Three separate detector fields of view are used to sense the Earth dayglow spectrum (980 A to 1040 A, and 1300 A to 1360 A) and the solar EUV spectrum (250 A to 1400 A). The authors demonstrate high gain (2 x 107), tight pulse-height distribution (35 percent FWHM), and a spatial resolution of about 35 microns FWHM (full width at half maximum), which is the highest resolution for a wedge-and-strip anode MCP detector flown to date. The background, image linearity, and flat-field performance are discussed. Raw spectra from the rocket flight are also presented.

Siegmund, O. H. W.↗

Abell 548: An X-ray and optical analysis of substructure

X-ray observations of Abell 548 reveal that the hot gas in this cluster is at least as complex as the galaxy distribution. Our ROSAT Position Sensitive Proportional Counter (PSPC) image is used in conjunction with optical data from the Minnesota plate-scanning project and redshift data in the literature to investigate the degree of substructure in the intracluster medium and the galaxy distribution. A548 has several X-ray components: hot gas associated with clumps of galaxies, individual sources, and a newly discovered diffuse component. This diffuse component may be promordial gas falling into the cluster for the first time. The optical data suggest that this cluster consists of four major components, not three (as indicated when velocity data are ignored). Simple models of the orbital dynamics suggest that the cluster may not yet have reached its turnaround radius.

Davis, David S.↗

Positions and proper motions of dwarf carbon stars

Recent-epochs positions and proper motions of nine dwarf carbon star candidates are presented along with finding charts for each object. Measurements are obtained from digitized Palomar Observatory Sky Survey (POSS) and Quik V plate archives at the Space Telescope Science Institute, and from recent CCD images.

Deutsch, Eric W.↗

Electrical Capacitance Volume Tomography for the Packed Bed Reactor ISS Flight Experiment

Fixed packed bed reactors are compact, require minimum power and maintenance to operate, and are highly reliable. These features make this technology a highly desirable unit operation for long duration life support systems in space. NASA is developing an ISS experiment to address this technology with particular focus on water reclamation and air revitalization. Earlier research and development efforts funded by NASA have resulted in two hydrodynamic models which require validation with appropriate instrumentation in an extended microgravity environment. To validate these models, the instantaneous distribution of the gas and liquid phases must be measured.Electrical Capacitance Volume Tomography (ECVT) is a non-invasive imaging technology recently developed for multi-phase flow applications. It is based on distributing flexible capacitance plates on the peripheral of a flow column and collecting real-time measurements of inter-electrode capacitances. Capacitance measurements here are directly related to dielectric constant distribution, a physical property that is also related to material distribution in the imaging domain. Reconstruction algorithms are employed to map volume images of dielectric distribution in the imaging domain, which is in turn related to phase distribution. ECVT is suitable for imaging interacting materials of different dielectric constants, typical in multi-phase flow systems. ECVT is being used extensively for measuring flow variables in various gas-liquid and gas-solid flow systems. Recent application of ECVT include flows in risers and exit regions of circulating fluidized beds, gas-liquid and gas-solid bubble columns, trickle beds, and slurry bubble columns. ECVT is also used to validate flow models and CFD simulations. The technology is uniquely qualified for imaging phase concentrations in packed bed reactors for the ISS flight experiments as it exhibits favorable features of compact size, low profile sensors, high imaging speed, and flexibility to fit around columns of various shapes and sizes. ECVT is also safer than other commonly used imaging modalities as it operates in the range of low frequencies (1 MHz) and does not radiate radioactive energy. In this effort, ECVT is being used to image flow parameters in a packed bed reactor for an ISS flight experiment.

Tomography↗

Multifrequency eddy-current detection of fast transient thermal signatures for in situ monitoring applications

Eddy-current (EC) nondestructive evaluation has a long history of use in a variety of ex situ defect monitoring applications because of its exquisite sensitivity to local material variations. Due to the relationship between a material's conductivity and its temperature, EC methods have also been used to investigate quasistatic, long-range temperature variations in casting applications. However, these techniques remain underutilized for the measurement of rapidly varying, spatially nonuniform temperature distributions. In this work, we construct a model system capable of generating repeatable temperature transients in steel plates and measure real-time eddy-current signals with millisecond time resolution and spatial resolution of the order of 1 mm. Using a combination of Multiphysics simulations, fast thermal imaging, and time-resolved holographic interferometry, we tease apart contributions to the eddy-current signals arising from temperature variations and transient plate deformation. Finally, we perform a systematic study in which we vary the plate thickness and the eddy-current excitation frequency to demonstrate that eddy-current techniques can provide information about a three-dimensional, time-varying, subsurface thermal distribution, which is inaccessible to the traditional thermal imaging techniques.

Rosenberg, Ethan R. [Lawrence Livermore National L↗

Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-ω) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-ω spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

Pressure Sensitive Paint↗

High-resolution imaging with a two-dimensional resistive anode photon counter

A method to achieve high spatial resolution readout of individual photoelectron events using microchannel plates and a resistive anode is presented. A clamped pair of microchannel plates is used, followed by a gap and a clamped triplet of microchannel plates in cascade to achieve a high stable electron gain of 3 x 10 to the 7th. The gain allows the position determination of each photoelectron event with a very high signal-to-noise ratio. A model consisting of a windowless vacuum-ultraviolet image sensor is presented to demonstrate 500 x 500 pixel images of 50 micron FWHM over a 25-mm circular field of view. The detector offers sufficient speed, sensitivity and resolution for a variety of applications, and the mount design is compatible with planar, remotely-processed, proximity-focused photocathodes.

Firmani, C.↗

Using SPHINX Accelerator to Measure Heat Transfer in Metal Foils [Slides]

Experiments on the SPHINX accelerator at Sandia National Laboratories (SNL) looked at electron beam heating of metal foils used in Bremsstrahlung flash x-ray production. Titanium and tantalum foils were exposed to electron beam energies of up to 2MeV to determine surface heating. As part of the experiment, the x-ray dose profiles were characterized using a scintillating panel (EJ-230) placed both perpendicular and parallel to the photon beam. This was followed by direct electron beam imaging using a fast-gated ICCD camera and a fused silica Cherenkov witness plate. Once characterized, the foil was directly measured using a mid-wave (3-5 micron) infrared camera (MWIR) to determine the peak surface temperatures and spatially-resolved thermal profiles. Additionally, an IR pyrometer was used in a single wavelength mode (2.3 µm) to determine localized surface temperatures as well. Results are compared with calculations of surface temperatures obtained from e-beam energy depositions combined with the specific heats of the foils. This is the first attempt to directly measure the surface temperature profile on a short-pulse (10 nanoseconds) flash x-ray source using MWIR imaging. These data are directly relevant for Monte Carlo/Integrated Tiger Series electron/photon transport code results being used in the design of future Bremsstrahlung sources such as CREST.

43 PARTICLE ACCELERATORS↗

An imaging vector magnetograph for the next solar maximum

Researchers describe the conceptual design of a new imaging vector magnetograph currently being constructed at the University of Hawaii. The instrument combines a modest solar telescope with a rotating quarter-wave plate, an acousto-optical tunable prefilter as a blocker for a servo-controlled Fabry-Perot etalon, CCD cameras, and on-line digital image processing. Its high spatial resolution (1/2 arcsec pixel size) over a large field of view (5 by 5 arcmin) will be sufficient to significantly measure, for the first time, the magnetic energy dissipated in major solar flares. Its millisecond tunability and wide spectral range (5000 to 7000 A) enable nearly simultaneous vector magnetic field measurements in the gas-pressure-dominated photosphere and magnetically-dominated chromosphere, as well as effective co-alignment with Solar-A's X ray images. Researchers expect to have the instrument in operation at Mees Solar Observatory (Haleakala) in early 1991. They have chosen to use tunable filters as wavelength-selection elements in order to emphasize the spatial relationships between magnetic field elements, and to permit construction of a compact, efficient instrument. This means that spectral information must be obtained from sequences of images, which can cause line profile distortions due to effects of atmospheric seeing.

Mickey, D. L.↗