Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ITALY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22

'Edge illumination' in X-ray Phase Contrast Imaging

In the late '90s, the concept of 'edge illumination' was developed at ELETTRA in Italy as an alternative method to increase the phase sensitivity of an imaging system. The main idea was to be able to reproduce the fine angular selection of 'analyzer' crystals without actually using a crystal, as this would allow employing the method with divergent and polychromatic (i.e. conventional) x-ray sources. It was observed that this could be achieved by illuminating only the edges of the detector pixels, and that the method's sensitivity could be progressively increased by illuminating smaller pixel fractions closer to its physical edge. A few years later the idea was adapted for use with a conventional source by means of two sets of x-ray masks ('coded aperture' masks), which enabled obtaining the same effect for each row (or column) of pixels of an area detector illuminated by a cone beam. This article reviews the method and presents recent examples of application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy distribution measurement of narrow-band ultrashort x-ray beams via K-edge filters subtraction

The characterization of novel x-ray sources includes the measurement of the photon flux and the energy distribution of the produced beam. The aim of BEATS2 experiment at the SPARC-LAB facility of the INFN National Laboratories of Frascati (Rome, Italy) is to investigate possible medical applications of an x-ray source based on Thomson relativistic back-scattering. This source is expected to produce a pulsed quasi-monochromatic x-ray beam with an instantaneous flux of 10{sup 20} ph/s in pulses 10 ps long and with an average energy of about 20 keV. A direct measurement of energy distribution of this beam is very difficult with traditional detectors because of the extremely high photon flux. In this paper, we present a method for the evaluation of the energy distribution of quasi-monochromatic x-ray beams based on beam filtration with K-edge absorbing foils in the energy range of interest (16-22 keV). The technique was tested measuring the energy distribution of an x-ray beam having a spectrum similar to the expected one (SPARC-LAB Thomson source) by using a tungsten anode x-ray tube properly filtered and powered. The energy distribution obtained has been compared with the one measured with a HPGe detector showing very good agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response function of the magnetic spectrometer PRISMA for the multinucleon transfer reaction {sup 40}Ar+{sup 208}Pb

Multinucleon transfer reaction {sup 40}Ar+{sup 208}Pb has been investigated with the PRISMA-CLARA experimental setup in LNL, INFN, Italy. The experimental differential cross sections have been obtained for different transfer channels by measuring more than {Delta}{theta}{sub lab} = 20 Degree-Sign covered by three angular settings of PRISMA. Results have been compared with the semiclassical calculation GRAZING. Since the understanding of the reaction mechanism depends strongly on the determination of absolute cross section, effect of transport of ions through PRISMA has been studied via a Monte Carlo simulation code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monolithic pixel detectors in silicon on insulator technology

Silicon On Insulator (SOI) is becoming an attractive technology to fabricate monolithic pixel detectors. The possibility of using the depleted resistive substrate as a drift collection volume and to connect it by means of vias through the buried oxide to the pixel electronic makes this kind of approach interesting both for particle and photon detection. In this paper I report the results obtained in the development of monolithic pixel detectors in an SOI technology by a collaboration between groups from the University and INFN of Padova (Italy) and the LBNL and the SCIPP at UCSC (USA).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion beams 12, Legnaro 6-8 June 2012, the 50 years (1961-2011) of the Legnaro Laboratory

A short review of the history of the Legnaro Laboratory is presented since its foundation 50 years ago by Prof. A. Rostagni of the University of Padova. The evolution of the Laboratory as a national reference center for fundamental and applied nuclear physics researches is outlined, pointing out its transformation into the INFN National Laboratories in 1968. After the first CN VdG Accelerator of 5.5 MV operating in 1961 and the AN2000 devoted to interdisciplinary researches (1971), i.e. 40 years ago, ten years later the advent of the first heavy ion facility in Italy, the XTU Tandem accelerator, and later on of the ALPI superconducting linear accelerator, was crucial for any future developments, not only in the field of nuclear physics but also for the evolution of interdisciplinary programmes with ion beams.

43 PARTICLE ACCELERATORS↗

The SIRAD irradiation facility at LNL

SIRAD is the irradiation facility at the Tandem XTU accelerator of the INFN National Laboratory of Legnaro (Padova, Italy) dedicated to study radiation effects, both comulative and Single Event, on silicon detectors and microelectronic devices and systems. SIRAD is routinely used by various research groups involved in the development of semiconductor detectors and electronics to be used in radiation hostile environments as experiments at high-energy/high luminosity accelerators or in space, or interested to study the basic radiation damage mechanisms. Single Events Effects (SEE) studies with micrometric resolution can be performed at SIRAD thanks to an Ion Electron Emission Microscope (IEEM) inserted at the end of the beam line. Here we describe the SIRAD facility including the available and future beam characteristics, and the IEEM performances as well as the scientific and technological solutions which have been implemented for its construction.

43 PARTICLE ACCELERATORS↗

Dosimetric property of mineral extracted from calamari and exposed to gamma rays

Dosimetric property of polymineral fraction, quartz mainly, obtained from calamari was investigated. The commercial calamari samples from China and Sud Africa were collected in the markets of Italy. All polymineral debris were extracted and isolated from the whole body of calamari. The surface of the polymineral samples was analyzed by using the Scanning Electron Microscopy (SEM) and their chemical composition was determined using Energy Dispersive Spectroscopy (EDS). The polymineral was exposed to gamma rays ({sup 60}Co) at different doses (0.5-80 Gy) to determine dosimetric property. Thermoluminescent (TL) glow curves showed two peaks centered at around 98-100 Degree-Sign C and 128-138 Degree-Sign C temperature range. The glow curves have been analyzed by using a deconvolution program. A linear dose response between 0.5 to 20 Gy was observed. The TL response of the samples as a function of the time storage, fading, presented a reduction of about 36-40 % at the end of 24 h. The reproducibility of the TL response after ten cycles of irradiation-readout showed an acceptable standard deviation in dosimetry. The polimineral fraction obtained from calamari shows an interesting dosimetric property and it may be useful for dosimetry in gamma radiation field.

36 MATERIALS SCIENCE↗

Purification of lanthanides for double beta decay experiments

There are several potentially double beta active isotopes among the lanthanide elements. However, even high purity grade lanthanide compounds contain {sup 238}U, {sup 226}Ra and {sup 232,228}Th typically on the level of ∼ (0.1 - 1) Bq/kg. The liquid-liquid extraction technique was used to remove traces of U, Ra and Th from CeO{sub 2}, Nd{sub 2}O{sub 3} and Gd{sub 2}O{sub 3}. The radioactive contamination of the samples before and after the purification was tested by using ultra-low-background HPGe γ spectrometry at the underground Gran Sasso National Laboratories of the INFN (Italy). After the purification the radioactive contamination of gadolinium oxide by Ra and Th was decreased at least one order of magnitude. The efficiency of the approach to purify cerium oxide from Ra was on same level, while the radioactive contamination of neodymium sample before and after the purification is below the sensitivity of analytical methods. The purification method is much less efficient for chemically very similar radioactive elements like lanthanum, lutetium and actinium. R and D of the methods to remove the pollutions with improved efficiency is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of the triple-point temperatures of {sup 20}Ne, {sup 22}Ne and normal Ne

At the National Metrology Institute of Japan (NMIJ), the triple points of {sup 20}Ne and {sup 22}Ne were realized using modular sealed cells, Ec3Ne20 and Ec8Ne22, made by the Istituto Nazionale di Ricerca Metrologica (INRiM) in Italy. The difference of the triple-point temperatures of {sup 20}Ne and {sup 22}Ne was estimated by using the sub-range of standard platinum resistance thermometers (SPRTs) calibrated by NMIJ on the International Temperature Scale of 1990 (ITS-90). The melting curves obtained with the Ec3Ne20 and Ec8Ne22 cells show narrow widths (0.1 mK) over a wide range of the inverse of the melted fraction (1/F) from 1/F=1 to 1/F=10. The liquidus point T{sub tp} estimated by the melting curves from F∼0.5 to F∼0.85 using the Ec8Ne22 is 0.146 29 (4) K higher than that using the Ec3Ne20 cell, which is in good agreement with that observed by INRiM using the same cells. After correction of the effect of impurities and other isotopes for Ec3Ne20 and Ec8Ne22 cells, the difference of T{sub tp} between pure {sup 20}Ne and pure {sup 22}Ne is estimated to be 0.146 61 (4) K, which is consistent with the recent results reported elsewhere. The sub-ranges of SPRTs computed by using the triple point of {sup 20}Ne or {sup 22}Ne realized by the Ec3Ne20 cell or the Ec8Ne22 cell in place of the triple point of Ne for the defining fixed point of the ITS-90 are in good agreement with those realized on the basis of the ITS-90 at NMIJ within 0.03 mK, which is much smaller than the non-uniqueness and the sub-range inconsistency of SPRTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photo-ionization of aluminum in a hot cavity for the selective production of exotic species project

SPES (Selective Production of Exotic Species) is an Isotope Separation On-Line (ISOL) based accelerator facility that will be built in the Legnaro-Istituto Nazionale di Fisica Nucleare (INFN) Laboratory (Italy), intended to provide intense neutron-rich radioactive ion beams obtained by proton-induced fission of a uranium carbide (UCx) target. Besides this main target material, silicon carbide (SiC) will be the first to be used to deliver p-rich beams. This target will also validate the functionality of the SPES facility with aluminum beam as result of impinging SiC target with proton beam. In the past, off line studies on laser photoionization of aluminum have been performed in Pavia Spectroscopy Laboratory and in Laboratori Nazionali di Legnaro; a XeCl excimer laser was installed in order to test the laser ionization in the SPES hot cavity. With the new Wien filter installed a better characterization of the ionization process in terms of efficiency was performed and results are discussed.

43 PARTICLE ACCELERATORS↗

{sup 12}C+{sup 12}C reactions at astrophysical energies: Tests of targets behaviour under beam bombardment

{sup 12}C({sup 12}C,α){sup 20}Ne and {sup 12}C({sup 12}C,p){sup 23}Na are the most important reactions during the carbon burning phase in stars. Direct measurements at the relevant astrophysical energy (E=1.5±0.3MeV) are very challenging because of the extremely small cross sections involved and of the high beam-induced background originating from impurities in the targets. In addition, persistent resonant structures at low energies are not well understood and make the extrapolation of the cross section from high energy data very uncertain. As a preliminary step towards the measurements of the {sup 12}C({sup 12}C,α){sup 20}Ne and {sup 12}C({sup 12}C,p){sup 23}Na reactions we intend to investigate the behaviour of targets under beam bombardment, specifically the quantitative measurement of hydrogen and deuterium content of highly pure stable carbon targets in relation to target temperature. Experiments are taking place at the CIRCE accelerator in Caserta, Italy and preliminary results are presented here.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shell structure in neutron rich nuclei by means of binary reactions

Nuclear structure studies far from stability rely mainly on the availability of radioactive nuclear beams but can complementary be addressed by means of high intensity beams of stable ions. In such contest, deep-inelastic and multinucleon transfer reactions are a powerful tool to populate yrast and non yrast states in neutron-rich nuclei. Particularly successful is here the combination of large acceptance spectrometers with highly segmented gamma-detector arrays. Such devices can provide the necessary channel selectivity to identify very rare signals. The AGATA gamma-ray detector array coupled to the PRISMA spectrometer at the Legnaro National Laboratories (LNL) in Italy is one example. Large data sets have been collected at LNL for nuclei close to the N=20, 28, 40, 50 and 82 shell closures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spectrometer for X-ray emission experiments at FERMI free-electron-laser

A portable and compact photon spectrometer to be used for photon in-photon out experiments, in particular x-ray emission spectroscopy, is presented. The instrument operates in the 25–800 eV energy range to cover the full emissions of the FEL1 and FEL2 stages of FERMI. The optical design consists of two interchangeable spherical varied-lined-spaced gratings and a CCD detector. Different input sections can be accommodated, with/without an entrance slit and with/without an additional relay mirror, that allow to mount the spectrometer in different end-stations and at variable distances from the target area both at synchrotron and at free-electron-laser beamlines. The characterization on the Gas Phase beamline at ELETTRA Synchrotron (Italy) is presented.

43 PARTICLE ACCELERATORS↗

ICP MS selection of radiopure materials for the GERDA experiment

The GERDA (GERmanium Detector Array) experiment, located in the Gran Sasso Underground Laboratory (LNGS, Italy) aims to search for neutrinoless double beta (0νββ) decay of the {sup 76}Ge isotope. Both an ultra-low radioactivity background environment and active techniques to abate the residual background are required to reach the background index (of 10{sup −3} counts/keV kg y) at the Q{sub ββ}. In order to veto and suppress those events that partially deposit energy in Ge detectors, the readout of liquid argon (LAr) scintillation light (SL) has been implemented for the second GERDA experimental Phase. A double veto system has been designed and constructed using highly radiopure materials (scintillating fibers, wavelength shifters, polymeric foils, reflective foils). This work describes the study of lead, thorium and uranium ultra-trace content, performed at the LNGS Chemistry Laboratory by High Resolution Mass Spectrometry (HR ICP MS), for the selection of all materials involved in the construction of the veto system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The LUNA experiment at Gran Sasso Laboratory: Studying stars by going underground

Accurate knowledge of thermonuclear reaction rates is a key issue in nuclear astrophysics: it is important for understanding the energy generation, neutrino production and the synthesis of the elements in stars and during primordial nucleosynthesis. Cross-section measurements are mainly hampered by the very low counting rate and cosmic background. An underground location is extremely advantageous for such studies, as demonstrated by the LUNA experiment in the Gran Sasso Laboratory (Italy). This paper reports on the results recently obtained by this experiment and on the future perspectives in the field.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of the effects of couplings to breakup channels in reactions induced by {sup 6}Li and {sup 6}He on the same {sup 64}Zn target

The experimental elastic scattering angular distributions for the weakly bound nuclei {sup 6,7}Li and for the halo nucleus {sup 6}He on the same {sup 64}Zn target at several energies around the Coulomb barrier were measured at the Laboratori Nazionali del Sud (LNS, Italy) and at the Cyclotron Research Center, Louvain La Neuve (Belgium), respectively. The measured elastic scattering angular distributions of these three systems at the same center of mass energy have been compared. The experimental data of the {sup 6,7}Li+ {sup 64}Zn systems have been analyzed within the CDCC method, while the {sup 6}He+{sup 64}Zn data have been compared with both both CDCC and CRC calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reaction dynamics induced by the radioactive ion beam {sup 7}Be on medium-mass and heavy targets

We studied the reaction dynamics induced at Coulomb barrier energies by the weakly-bound Radioactive Ion Beam {sup 7}Be (S{sub α} = 1.586 MeV) on medium-mass ({sup 58}Ni) and heavy ({sup 208}Pb) targets. The experiments were performed at INFN-LNL (Italy), where a 2-3×10{sup 5} pps {sup 7}Be secondary beam was produced with the RIB in-flight facility EXOTIC. Charged reaction products were detected by means of high-granularity silicon detectors in rather wide angular ranges. The contribution presents an up-to-date status of the data analysis and theoretical interpretation for both systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-temperature apparatus for chaotic mixing of natural silicate melts

A unique high-temperature apparatus was developed to trigger chaotic mixing at high-temperature (up to 1800 °C). This new apparatus, which we term Chaotic Magma Mixing Apparatus (COMMA), is designed to carry out experiments with high-temperature and high-viscosity (up to 10{sup 6} Pa s) natural silicate melts. This instrument allows us to follow in time and space the evolution of the mixing process and the associated modulation of chemical composition. This is essential to understand the dynamics of magma mixing and related chemical exchanges. The COMMA device is tested by mixing natural melts from Aeolian Islands (Italy). The experiment was performed at 1180 °C using shoshonite and rhyolite melts, resulting in a viscosity ratio of more than three orders of magnitude. This viscosity ratio is close to the maximum possible ratio of viscosity between high-temperature natural silicate melts. Results indicate that the generated mixing structures are topologically identical to those observed in natural volcanic rocks highlighting the enormous potential of the COMMA to replicate, as a first approximation, the same mixing patterns observed in the natural environment. COMMA can be used to investigate in detail the space and time development of magma mixing providing information about this fundamental petrological and volcanological process that would be impossible to investigate by direct observations. Among the potentials of this new experimental device is the construction of empirical relationships relating the mixing time, obtained through experimental time series, and chemical exchanges between the melts to constrain the mixing-to-eruption time of volcanic systems, a fundamental topic in volcanic hazard assessment.

36 MATERIALS SCIENCE↗